• 제목/요약/키워드: sensible

검색결과 663건 처리시간 0.024초

하이브리드 제습냉방시스템의 성능평가 연구 (A Study on the Performance Evaluation of a Hybrid Desiccant Cooling System)

  • 황원백;김용찬;이대영
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.121-128
    • /
    • 2012
  • Improvement in the energy efficiency has been studied of the desiccant cooling system by applying a vapor compression type heat pump to modify the system into a hybrid system. The cycle simulation was performed and the results were compared between a reference desiccant cooling system composed of a desiccant rotor, a sensible rotor and a regenerative evaporative cooler, and a hybrid desiccant cooling system with the sensible rotor being replaced by a heat pump. Though the electric consumption increases as much as the compressor power consumption, the total cooling capacity increases and the thermal energy input decreases by the addition of the heat pump. Therefore, the total energy efficiency can be improved if the increase in the electric consumption can be compensated with the increase in the cooling capacity and the decrease in the thermal energy input. The results showed that the total energy efficiency is optimized at a certain heat pump capacity. When the heat from the CHP plant is used for the thermal energy input, the energy consumption of the hybrid system is reduced by 20~30% compared with the reference system when the heat pump shares 30~40% of the total cooling capacity.

중국 조선족 아동의 한글 자소-음소 대응능력의 발달과 글자읽기와의 관계에 관한 연구 (The Development of Grapheme-Phoneme Correspondence Rules and Kulja Reading in Korean-Chinese Children)

  • 윤혜경;박혜원
    • 아동학회지
    • /
    • 제26권4호
    • /
    • pp.145-155
    • /
    • 2005
  • This study was carried out to reveal Hangul acquisition processes in Korean-Chinese children who grow in a horizontal bilingual environment. In this experiment Grapheme substitution/deletion tasks and sensible/non-sensible Kulja reading tasks were administered to 3-, 4-, 5- and 6-year-old Korean-Chinese children growing up in a bilingual environment. Results were that Korean-Chinese children showed similar patterns of Hangul acquisition processes to Korean children but acquired grapheme-phoneme(G-P) correspondence earlier than Korean children. Hangul acquisition rates were 41.7%, 45.7%, 53% and 92.7% at age 3, 4, 5 and 6, respectively. Both Korean-Chinese and Korean children showed higher sensitivity for the final consonant than for the initial and middle consonants. Correlation between phoneme perception and reading was only significant among 6-year-olds in non-sensible Kulja reading tasks. Training in transforming ideographic Chinese to a phonetic system could effect early acquisition of G-P correspondence in Korean-Chinese children.

  • PDF

Airborne Remote Sensing of Evapotranspiration over Rice Paddy

  • Chen, Y.Y.;Liou, Yuei-An
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.351-353
    • /
    • 2003
  • We present a retrieval scheme for the remote sensing of evapotranspiration (ET) over rice paddy. To perform the retrieval, high-resolution airborne imagery of multi-spectral visible and thermal infrared data, and ground-based meteorological measurements are utilized. Our ET retrieval scheme is based on the basic principal of surface energy budget, which is a result of balance in longwave and shortwave radiation, latent heat, sensible heat, and energy flux into the ground. To partition the latent and sensible heat fluxes of interest from the energy balance equation, three basic parameters are of most concern, including albedo, surface temperature, and normalized difference vegetation index (NDVI). The NDVI and albedo can be easily derived from the visible and near infrared spectral data, while the surface tem-perature can be determined through the analysis of the infrared data with the Stefan Boltzmann law. From the airborne imagery taken on 28 April 2003, we observe very good dry and wet pixels that can be easily corre-sponded to the radiation and evaporation controlled crite-ria, respectively, and, hence, for the further use in defin-ing the evaporative fraction needed to partition sensible and latent heat fluxes from the net energy flux. The de-rived ET is compared with the in situ measurements.

  • PDF

Performance Analysis of Sensible and Latent Energy Recovery System for Thermally Controlled Facility

  • Park, Byung-Kyu;Kim, Moo-Geun;Kim, Geun-Oh
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권4호
    • /
    • pp.17-26
    • /
    • 2001
  • Simulation was conducted using TRNSYS to evaluate the thermal performance of a facility. This facility has a condensing-type heat exchanger which is able to recover the latent energy for the purpose of reducing the heating energy in winter. The boiler and chiller are selected based on the annual peak loads and controlled to maintain the facility at the set temperature of 14~$17^\circ{C}$. Supplied energy by the boiler and recovered energy by the heat exchanger were calculated as a function of number of pass through heat exchanger, kind of fuel and hot water velocity. Simulation results show that about 20% of the total heating load can be recovered by the heat exchanger and the amount of latent heat is increasing with the number of pass. This means that the efficiency of the waste energy recovery system can be increased by using a condensing-type heat exchanger rather than a traditional sensible heat exchanger.

  • PDF

재생증발식 수냉각기의 냉각성능 해석 (Investigation on the Cooling Characteristics of a Regenerative Evaporation Water Cooler)

  • 최봉수;홍희기;이대영
    • 설비공학논문집
    • /
    • 제18권5호
    • /
    • pp.393-401
    • /
    • 2006
  • The regenerative evaporation water cooler is devised and analysed in this study. The regenerative evaporation water cooler is composed of a sensible heat exchanger to cool the incoming air, followed by a latent heat exchanger to cool the water evaporatively with the cooled air flowing out of the sensible heat exchanger. By linearizing psychrometric characteristics, the heat and mass transfer in the regenerative evaporation water cooler is analyzed theoretically. The results show that the water can be cooled down even lower than the wet-bulb temperature of the inlet air. When the inlet air is $32^{\circ}C$ and 20% in relative humidity, and the inlet temperature of the water is $20^{\circ}C$, the regenerative evaporation water cooler provides a larger cooling capacity than the conventional evaporation water cooler if the effectiveness of the latent heat exchanger is higher than 0.6 and that of the sensible heat exchanger is higher than 0.5.

제품디자인을 위한 조형 이미지의 평가와 선호에 관한 연구 (A Study on Consumer's Evaluations on and Preferences for Formative images of Products)

  • 김관배
    • 디자인학연구
    • /
    • 제13권1호
    • /
    • pp.167-178
    • /
    • 2000
  • 오늘날의 세계는 후기산업사회에서 정보화사회로 급속하게 변화되고 있으며, 시대적 가치기준은 하드웨어 중심의 물에서 소프트웨어 중심의 지와 감으로 전환되고 있다. 이를 바탕으로 소비시장에서는 제품 본래의 물적 가치보다도 인간 중심의 지적, 정서적 가치가 더 중요시되고 있다. 이러한 흐름 속에서 최근의 제품디자인의 환경 또한 급속하게 변화되고 있다. 사용자 및 소비자는 제품의 이미지를 바탕으로 자신의 연출을 통한 감성적 만족을 추구하고 있다. 사용자 및 소비자가 제품을 사용하는 환경을 중시함에 따라 기업들은 소비자의 감성적 요구, 즉 쾌적성, 흥미성, 사용성에 대응하기 위하여 사용자 및 소비자 중심의 제품개발 체젤 전환하고 있다. 즉, 기업활동의 중심이 사용자 및 소비자로 변화되면서 기업들은 제품개발에 있어서 Human Technology 우주로 기술혁신을 전개하는 한편, 디자인 기능을 강화하고 이를 전략적으로 활용하여 디자인 중시형 제품을 개발함으로써 자사 제품에 대한 사용자 및 소비자의 감성적 만족을 도모하고 있다. 이러한 디자인 환경의 변화속에서 제품디자인 부문의 과제는 감성적 디자인의 개발이다. 바꾸어 말하면, 사용자의 생활문화를 중심으로 감성에 대한 체계적인 연구를 바탕으로 감성적 디자인 접근방법을 통하여 사용자 및 소비자가 감성적으로 만족할 수 있는 디자인을 개발함으로써 제품 경쟁력을 제고시키고 기업 이미지를 향상시키는 것이 과제이다. 이러한 배경에서 본 연구는 '소비자의 감성적 요구의 정량화'에 중점을 두고 소비자의 조형 이미지에 대한 실제적인 조사 및 분석 방법의 하나로 잠재적 소비자를 대상으로 소비와 관련하여 감성유형에 따른 제품의 조형 이미지 평가와 선호에 대하여 살펴보고자 하였다. 이를 위하여 문헌 연구를 통하여 감성과 디자인, G감성과 제품디자인에 관하여 살펴보았으며, 설문조사를 통하여 데이터를 수집하고 통계 프로그램을 통하여 분석한후 그 결과를 종합적으로 해석함으로써 더 유효성이 높은 접근 가능성을 모색하고자 하였다.

  • PDF

위성 영상을 활용한 두 가지 현열 플럭스 추정 방법 간의 비교 (Comparison of Two Methodsto Estimate Urban Sensible Heat Flux by Using Satellite Images)

  • 김상혁;이동근
    • 환경영향평가
    • /
    • 제31권1호
    • /
    • pp.63-74
    • /
    • 2022
  • 도시 지역의 열 환경을 파악하기 위해 열 플럭스를 추정하고자 하는 연구들이 많이 진행되어 왔다. 현재 다양한 방법을 통해 현열 플럭스가 추정되고 있으나 각 방법 간의 차이를 비교하는 연구는 매우 미흡한 실정이다. 따라서 본 연구는 대표적인 두 가지 현열 플럭스 추정 방법을 통해 동일한 대상지의 현열 플럭스를 추정하고 그 결과를 비교하여 방법 간의 의의와 한계를 확인하고자 하였다. 연구 결과 열수지 방정식 방법을 통해 현열 플럭스를 추정할 경우 해상도면에서 큰 장점을 가지나 도시 지역의 특징 중 하나인 인공열을 반영하지 못해 현열이 과소추정될 수 있음을 확인할 수 있었다. 물리식을 기반으로 추정할 경우 상대적으로 오차가 작고 인공열의 반영이 가능하나, 시간 및 공간 해상도에 있어 한계가 있음을 확인하였다. 두 방법은 인공열이 많이 발생하는 공업지역에서 가장 큰 차이를 나타냈으며 그 차이는 평균 약 135 W/m2, 최대 400 W/m2로 나타났다. 반면 녹지 및 수변공간은 약 20 W/m2로 두 방법 간의 차이가 매우 작은 것을 확인할 수 있었다. 두 방법 간의 결과가 도시 지역에서 유의미한 차이를 보이는 만큼 향후 연구 목적에 맞는 방법을 선택할 필요가 있다.