• 제목/요약/키워드: sem

검색결과 18,789건 처리시간 0.048초

Pb(Ni1/3Nb2/3)O3-PZT 세라믹스 고용체에서 과잉 NiO첨가에 따른 압전특성 변화 (The Effect of NiO Addition to the PNN-PZT Piezoelectric Ceramics on Piezoelectric Properties)

  • 최용길;손영진;권준철;조경원;윤만순;김일호;김영민;어순철
    • 한국재료학회지
    • /
    • 제15권6호
    • /
    • pp.413-418
    • /
    • 2005
  • Perovskite $Pb(Ni_{1/3}Nb_{2/3})O_3-Pb(Zr,Ti)O_3[PNN-PZT]$ ceramics were synthesized by conventional ceramic processing technique. In order to modify piezoelectric properties for sensor application in this system, NiO addition was considered to provide $Ni^{+2}$ as an acceptor, which was known to occupy with B site in the structure. The effect of NiO addition up to $8\;mol\%$ on the following piezoelectric properties as well as sintering properties was investigated. When NiO added more than $1\;mol\%$, average grain size was decreased and second phase was found to form. Moreover, the second phase caused decrease in relative dielectric constant $(\varepsilon_{33}T/\varepsilon0)$, electro-mechanical coupling factor $(k_p)$, and piezoelectric charge constant $(d_{33})$, while increasing mechanical quality factor $(Q_m)$. When $1\;mol\%$ NiO was added, density, dielectric properties and piezoelectric properties were abruptly increased.

타액에 오염된 상아질에 대한 콤포머의 접합양상 (THE ADHESIVE PATTERNS OF COMPOMER TO SALIVA-CONTAMINATED DENTIN)

  • 조영곤;김병태;이석종
    • Restorative Dentistry and Endodontics
    • /
    • 제25권4호
    • /
    • pp.575-586
    • /
    • 2000
  • In this study, adaptation of compomer to saliva contaminated dentin was evaluated with scanning electron microscope(SEM) and confocal laser scanning microscope(CLSM). For the SEM study, the occulusal surfaces of thirty two molar teeth were grounded to exposure dentin surfaces. The specimen were randomly assigned to control and three experimental groups with four samples in each group. In control group, Dyract and F-2000 compomer were bonded on the specimens according to the manufactures direction. Experimental groups were subdivided into three groups. They were contaminated with saliva on dentin surfaces ; Experimental group 1 : Saliva was dried with compressed air. Experimental group 2 : Saliva was rinsed with air-water spray and dried. Experimental group 3 : After polymerization of an adhesive, they were contaminated with saliva, and then saliva was rinsed with air-water spray and dried. Dyract and F-2000 compomer were bonded on saliva-treated dentin surfaces. The interfaces between dentin and compomer were observed with SEM. For the CLSM study, Class V cavities were prepared in buccal and ligual surfacess of thirty two molars. The specimens were divided into control and experimental groups. Class V cavities in experimental group were contaminated with saliva and those surfaces in each experimental groups received the same treatments as for the SEM study. Cavities were applied Prime & Bond 2.1 and F-2000 compomer primer/adhesive that were mixed with fluorescein, and then were filled with Dyract and F-2000 compomer. Specimens were embedded in transparent acrylic resin and sectioned buccolingual1y with diamond wheel saw, and then mounted on cover slide for CLSM study. The interface between cavity and compomer was observed by fluoresence imaging with a CLSM. The results were as follows : 1. In SEM exammination of Dyract group, control group, experimental group 2, 3 showed close adaptation to dentin and hybrid layer of $3{\sim}4{\mu}m$ diameter. Interfacial gap between compomer and dentin in experimental group 1 was wider than in control group. 2. In SEM examination of F-2000 group, adaptation to dentin of control group was closer than Dytact control group, but hybrid-like layer was not observed. Interfacial gap between compomer and dentin in experimental group 1 was wider than in Dyract experimental group 1. 3. In dissolution specimens of Dyract and F-2000 group, resin tags penetrated through dentinal tubules in control group and experimental group 1 and 3, but the penetration of resin tag was irregular and partial in experimental group 1. 4. In CLSM exammination of Dyract and F-2000 group, adhesive patterns of control and experimental groups showed same as in SEM. This result suggests the treatment methods, rinsing & drying, repeating all adhesive procedures, will produce good effect on adaptation of compomer to dentin if the dentin surface or polymerized adhesive is contaminated by saliva.

  • PDF

Cd, Ni, Zn로 오염된 퇴적물에 노출된 Neanthes arenaceodentata의 금속 생물축적, 사망 및 성장저해에 대한 Acid Volatile Sulfide(AVS) 영향 (The Influence of Acid Volatile Sulfide (AVS) on the Bioavailabiltiy and Toxicity of Cd, Ni, and Zn in Sediments to Marine Polychaete Neanthes Arenaceodentata)

  • 이종현;고철환
    • 한국해양학회지:바다
    • /
    • 제7권4호
    • /
    • pp.226-234
    • /
    • 2002
  • 퇴적물 내 황화물(acid volatile sulfide, AVS)이 저서 생물의 금속 생물 축적 및 독성 반응에 어떠한 영향을 미치는 지를 이해하기 위해서 해양 다모류인 Neanthes arenaceodentata를 이용한 퇴적물 노출실험을 수행하였다. 이를 위해서 세 개의 다른 AVS 농도군에 대조구를 포함한 다섯 개의 농도 구배로 Cd, Ni, Zn를 오염시킨 퇴적물에서 N. arenaceodentata를 20일간 배양한 후 실험생물의 체내 금속 축적량과 그에 따른 사망률 및 성장률을 조사하였다. N. arenaceodentata에 의한 금속의 생물축적은 Cd과 Zn의 경우 AVS 농도의 영향을 받아서 해수(overlying water, OW)내 용존 금속 농도에 비례해서 증가했다. Ni은 AVS농도에 영향을 받지 않고 퇴적물 내 금속(simultaneously extracted metals. SEM)농도에 비례해서 증가했다. N. arenaceodentata의 사망과 성장률 저해현상은 SEM과 AVS 간의 몰농도차가 영보다 큰 조건([SEM-AVS]>0)에서만 관찰되었는데 용존 Zn에 의한 결과로 추정되었다. OW-Zn의 20-d LC50값은 9.3(8.0$\pm$11.0) $\mu$M이었다. 사망률에 대한 체내 Zn 농도의 최소영향농도(LOEC)는 7.8 $\mu$mol/g이었고, 최대무영향농도(NOEC)는 6.2$\mu$mol/g이었다. 성장률 저해에 대한 체내 Zn 농도의 LOEC는 5.9$\mu$mol/g이었고, NOEC은5.1 $\mu$mol/g토이었다. 본 실험에서는 실험실 조건에서 인위적으로 오염시킨 퇴적물 내 Zn의 입자상 Zn 농도와 용존 Zn농도의 비 (K$_{d}$ )가 현장 퇴적물에 비해서 10배 정도 감소함으로써 결국 용존 Zn에 의한 독성이 과대평가된 것으로 보인다.

비팽윤성 운모의 표면코팅 및 특성평가 (Surface coating and characterizations of non-swelling property mica)

  • 박라영;석정원;박선민;김판채
    • 한국결정성장학회지
    • /
    • 제18권3호
    • /
    • pp.131-135
    • /
    • 2008
  • 본 연구에서는 합성운모에 대한 코팅기술을 확립한 뒤, 비수성을 나타내는 합성운모를 제조하였다. 합성운모의 표면코팅은 고속교반기를 사용하여 행하였으며, 스테아린산으로 코팅된 합성운모의 특성은 침적실험, XRD 및 SEM을 이용하여 분석하였다. 본 연구 결과, 교반기의 내부온도는 $70^{\circ}C$를 유지하고, 10분 동안 1600 rpm/min을 행함으로써 운모 표면에 스테아린산의 코팅이 가능하였다. 또한 SEM 관찰결과로부터, 스테아린산과 운모의 혼합비율, 교반기 내부온도, 회전속도에 의해 특성이 변화하는 반면 코팅처리시간과는 무관함을 알 수 있었다.

한국형 고속철도 승차감의 감성 모형 개발 (Development of a Ride-comfort Model for Korea Train eXpress (KTX) Passengers)

  • 이주환;이철;김인기;윤명환
    • 대한인간공학회지
    • /
    • 제26권1호
    • /
    • pp.87-92
    • /
    • 2007
  • KTX (Korea Train eXpress) is launched as the $5^{th}$ develop a ride-comfort model for high-speed rail pasengers using structural equation model (SEM). Both qualitative and quantitative factors affecting ride-comfort were investigated, and employed to construct a comprehensive ride-comfort model. The SEM model was built with twenty measurement variables and seven latent variables for the evaluation of ride-comfort of high-speed train passenger. A total of six hundreds thirty two subjects participated in the evaluation using face-to-face survey method. As a result, the proposed SEM model model fitnes (GFI=0.93). According to the results, overall ride-comfort was significantly affected by the seat-, fatigue-, interior-related, and customer satisfaction variables such as fare. Among the engineering design variables of high-speed train, seat-related variables were identified as critical factors of the ride-comfort. It is expected that the result of this study could be useful for the enhancement of ride comfort in next generation KTX.

Reproducibility of the Isokinetic Joint Torque as a Rotator Cuff Weakness Test Protocol in Patients With Rotator Cuff Tendinitis

  • Kim, Soo-yong;Oh, Jae-seop
    • 한국전문물리치료학회지
    • /
    • 제24권3호
    • /
    • pp.21-29
    • /
    • 2017
  • Background: The measurement of the strength of the shoulder muscles is an important element of the overall assessment of patients with various shoulder disorders. However, the clinical utilization of this measurement is dependent on its reproducibility. Objects: To explore the reproducibility of the measurements derived from testing of the isokinetic strength of shoulder muscles in patients with tendinitis of the rotator cuff. Methods: A total of 20 patients with tendinitis of the rotator cuff participated in this study and were assessed twice in 1 week. Isokinetic testing was performed concentrically for shoulder flexors, abductors, and external rotators and eccentrically for the shoulder extensors, adductors, and internal rotators. The relative and absolute reproducibility of the peak torque (PT) and ratios were assessed using intra-class correlation coefficients (ICC), standard error of measurement (SEM), and minimal clinically important difference (MCID), respectively. Results: Overall, high to excellent ICC, clinically acceptable SEM and MCID values were obtained for the PT (ICC: .83-.95, SEM: 1.2%-9%, MCID: 3.4%-25%) and ratios (ICC: .85-.93, SEM: 5.1%-10%, MCID: 14.2%-27.6%). Conclusion: These findings suggest that isokinetic tests may be effectively utilized for the determination of shoulder strength profiles and appropriate position are recommended to perform test without pain in patients with tendinitis of the rotator cuff.

Clay를 함유한 Polysulfone 나노섬유 복합막의 제조 및 물리적 특성 연구 (Mechanical Property of Clay-polymer Nanofiber Composite Membrane)

  • 박예지;윤재한;변홍식
    • 멤브레인
    • /
    • 제27권3호
    • /
    • pp.284-289
    • /
    • 2017
  • 본 연구에서는 복합막의 물성향상을 위해 clay를 도입한 polysulfone 나노섬유 복합막을 제조하였다. Polysulfone/clay 복합막은 clay가 들어간 N,N-dimethyl acetamide와 acetone 혼합용매에 polysulfone을 첨가한 후 전기방사법을 이용하여 제조하였으며, 제조된 나노섬유 복합막은 적층수를 변화해 기공크기를 조절한 후 사용하였다. 전반적인 분리막의 특성은 SEM, contact angle, 기공특성, tensile strength, water flux 분석을 사용하여 고찰하였다. 특히 SEM image로 clay의 도입을 확인하였으며 contact angle 측정을 통해 표면이 개질된 결과를 확인할 수 있었다. 그리고 clay의 도입량에 따른 복합막의 기계적 물성을 확인하였다. 따라서 본 연구에서 제조된 분리막은 수처리용 분리막으로 충분히 활용 가능할 것으로 판단된다.

TIN-M(M=Co, NI) 복합 분리막의 제조 및 수소투과 특성평가 (Fabrications and Evaluations of Hydrogen Permeation on TIN-M(Co, NI) Composite Membrane)

  • 김경일;유성웅;홍태환
    • 한국수소및신에너지학회논문집
    • /
    • 제21권4호
    • /
    • pp.264-270
    • /
    • 2010
  • Recently, the most promising methods for high purity hydrogen production are membranes separation such as polymer, metal, ceramic and composites. It is well known that Pd and Pd-alloys membranes have excellent properties for hydrogen separation. However, it has hydrogen embrittlement and high cost for practical applications. Therefore, most scientists have studied new materials instead of Pd and Pd-alloys. On the other hand, TiN powders are great in resistance to acids and chemically stable under high operating temperature. In order to get specimens for hydrogen permeation, the TiN powders synthesized were consolidated together with Co, Ni powders by hot press sintering (HPS). During the consolidation of powders at HPS, heating rate was 10 K/min and the pressure was 10 MPa. It was characterized by XRD, SEM. Also, we estimated the hydrogen permeability by Sievert's type hydrogen permeation membrane equipment.

SEM 측정법에 의한 초정밀 표면가공 특성연구 (A Study on the Surfaces Machining Characteristics of Ultra-precision through SEM Measurement)

  • 강순준;오상록;이갑조;김종관
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.34-41
    • /
    • 2004
  • The purpose of this paper is to look at the characteristics of surface finishing which is one of the form accuracies and to obtain the fundamental technical data from the process of machining with diamond tool through experiment and theoretical analysis. The experiments were conducted with domestic made ultra-precision machine and MCD.PCD tool, with aluminum alloyed material and brass being used for the work pieces. The goal of the size accuracy was set to 100nm. The most suitable tool nose radius and machining conditions were selected, and the variations of the surface roughness were observed using SEM method while machining the distance of up to 500km. These data were evaluated and they examined the variation of the machined surfaces while cutting up to 500km of machining distance. At the same time, the state for the wear of diamond tool nose was analyzed and carefully examined through the newest measuring device. Additionally, the characteristics of ultra-precision machining technology were studied through visual analysis.

  • PDF