• Title/Summary/Keyword: self-imaging

Search Result 209, Processing Time 0.029 seconds

The Influence of Anxiety Sensitivity on Task Performance and Stress Response: The Moderating Effect of Depression (불안민감도가 과제 수행과 스트레스 반응에 미치는 영향: 우울감의 조절효과)

  • Kim, Sori;Lee, Jung Hyun
    • Stress
    • /
    • v.27 no.2
    • /
    • pp.199-204
    • /
    • 2019
  • Backgoround: This study aimed to examine the influence of anxiety sensitivity on task performance and physiological stress response, and to assess the effect of depression in this process for the youth population. Methods: We presented participants with an uncontrollable stress situation where they were required to perform mental arithmetic, based on the Montreal Imaging Stress Task (MIST). A total of 29 participants volunteered for this study. They completed the Anxiety Sensitivity Index-Revised and Patient Health Questionnaire-9 to measure their levels of anxiety sensitivity and depression. Two saliva samples, one before and one after the experiment, were collected to assess the change in cortisol levels as an index of physiological stress response. Results: Participants with high anxiety sensitivity showed lower performance on the mental arithmetic tasks and a significant increase in a salivary cortisol level, compared to those with low anxiety sensitivity. Furthermore, cortisol levels showed a remarkable increase where high anxiety sensitivity was coupled with depressed mood. In other hands, the levels of cortisol remained unchanged despite high anxiety sensitivity with low depressed mood. Conclusions: Our results confirm that the interaction between anxiety sensitivity and depression affects participants' task performance and stress response, as measured through behavioral tasks and physiological data with self-report indices. Also, through the physiological data, we examined that those who have a high level of anxiety sensitivity showed maladaptive responses under high stressful situation.

Homosexuality and Utopia: A Reading of Whitman's Calamus (동성애와 유토피아 -휘트먼의 『창포』를 중심으로)

  • Son, Hyesook
    • Journal of English Language & Literature
    • /
    • v.58 no.1
    • /
    • pp.43-67
    • /
    • 2012
  • My essay aims at illustrating Whitman's homosexual vision of utopia with a close reading of his representative homosexual text, Calamus. His expansive self is based upon his intimate contact with the world and is almost always drawn to a wider vision of community in which different individuals share the locus of commonness and reach beyond their empirical boundaries. While foregrounding the contingent and the singular, Whitman forges bonds with other people through a series of ecstatic moments that carry us into the public sphere and common interests. Contrary to the current Whitman studies, his homosexual text doesn't repress contingency in order to celebrate the universal, but fully develops the commensurability among diverse historical agents. Whitman knows well the social taboos and inhibitions at the time of national crisis and expansion, but keeps imagining the world where homosexuality plays a central and significant role in founding a democratic solidarity and achieving a desirable social structure. His ideal of America is not a deferred wish for the future, but a concrete vision that can be achieved here and now, realized by the spontaneous bonding and instant attraction among free men. Instead of interpreting history or suggesting practical alternatives, he keeps questioning the dominant ideologies and the given orders of social control, and suggests a free and open relationship among men where no exterior power or mediating other intervenes. His utopian vision is radical as well as ideal, in that it rejects the interventions of the power structure and its institutions and courageously inscribes his homosexuality in the process of writing about and reading his contemporary America. As a predecessor of a homosexual utopian vision of America, Whitman has inspired many later poets, showing a possibility of infusing a homosexual identity into a radical imaging of the nation and its future.

Effects of Core Exercise on Body Composition, Abdominal Muscle Thickness, Trunk Muscular Endurance, and Psychological Factors in Normal-weight Obese Women (코어운동이 마른 비만 여성의 신체조성과 복부 근육두께, 몸통 근지구력, 심리적 요인에 미치는 영향)

  • Sang Ho Kim;Tae Hwa Seo;Nam Gi Lee
    • Journal of Korean Physical Therapy Science
    • /
    • v.30 no.3
    • /
    • pp.72-83
    • /
    • 2023
  • Background: Normal-weight obese women have a normal weight with relatively low muscle mass resulting from high body fat. We aimed to investigate the effects of core exercise on body composition, abdominal muscle thickness, trunk muscular endurance, and psychological factors in normal-weight obese women. Design: One group pre-, mid-, and post-test design. Methods: A total of 20 normal-weight obese women were recruited voluntarily. Core exercises were performed for 30 minutes, three times a week for 4 weeks. InBody measurements, ultrasound imaging, and clinical tests were used to assess body composition, abdominal muscle thickness, trunk and core muscular endurance, and psychological condition(satisfaction with appearance and self-esteem). The dependent variables were measured three times: before the intervention (pre-test), 2 weeks after the intervention (mid-test), and 4 weeks after intervention (post-test). One-way repeated measures ANOVA and Friedman test were used for statistical analysis. Results: Although there was no change in the body composition (p>0.05), thickness of the transversus abdominis and internal and external oblique muscles, endurance of the trunk flexors and extensors and core muscles, and psychological condition showed significant differences after the intervention (p<0.05). Conclusion: Our findings will help develop exercise programs for normal-weight obese individuals that utilize the beneficial effect of core exercises.

The role of internal architecture in producing high-strength 3D printed cobalt-chromium objects

  • Abdullah Jasim Mohammed;Ahmed Asim Al-Ali
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.2
    • /
    • pp.91-104
    • /
    • 2024
  • PURPOSE. The objectives of the current study were to estimate the influence of self-reinforced hollow structures with a graded density on the dimensional accuracy, weight, and mechanical properties of Co-Cr objects printed with the direct metal laser sintering (DMLS) technique. MATERIALS AND METHODS. Sixty-five dog-bone samples were manufactured to evaluate the dimensional accuracy of printing, weight, and tensile properties of DMLS printed Co-Cr. They were divided into Group 1 (control) (n = 5), Group 2, 3, and 4 with incorporated hollow structures based on (spherical, elliptical, and diamond) shapes; they were subdivided into subgroups (n = 5) according to the volumetric reduction (10%, 15%, 20% and 25%). Radiographic imaging and microscopic analysis of the fractographs were conducted to validate the created geometries; the dimensional accuracy, weight, yield tensile strength, and modulus of elasticity were calculated. The data were estimated by one-way ANOVA and Duncan's tests at P < .05. RESULTS. The accuracy test showed an insignificant difference in the x, y, z directions in all printed groups. The weight was significantly reduced proportionally to the reduced volume fraction. The yield strength and elastic modulus of the control group and Group 2 at 10% volume reduction were comparable and significantly higher than the other subgroups. CONCLUSION. The printing accuracy was not affected by the presence or type of the hollow geometry. The weight of Group 2 at 10% reduction was significantly lower than that of the control group. The yield strength and elastic modulus of the Group 2 at a 10% reduction showed means equivalent to the compact objects and were significantly higher than other subgroups.

Kikuchi Disease Manifesting as Multifocal Lymphadenopathy and Splenomegaly: Ultrasonography, CT, and 18F-FDG PET/CT Findings Mimicking Lymphoma (다발성 림프절염과 비장종대로 발현하여 림프종으로 오인된 기쿠치병의 초음파, CT, 18F-FDG PET/CT 소견)

  • Moin Ha;Bo-Kyung Je;Eung-Seok Lee;Seong Wook Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1486-1491
    • /
    • 2020
  • Kikuchi disease is a type of benign, self-limiting necrotizing lymphadenitis that occurs most commonly in young women and usually manifests as palpable cervical lymph nodes and fever. Patients with an unusual location of lymph node involvement can be misdiagnosed with malignant disease. Here, we report a case of Kikuchi disease in a 15-year-old girl presenting with persistent fever for 2 weeks. Imaging studies, including ultrasonography, CT, and 18F-fluorodeoxyglucose PET/CT, revealed splenomegaly and enlarged lymph nodes in the neck, axilla, abdomen, retroperitoneum, and inguinal region. Laparoscopic excision of the celiac lymph nodes confirmed histiocytic necrotizing lymphadenitis, also known as Kikuchi disease. Conservative treatment with corticosteroids improved the patient's condition.

Analysis of Image Distortion on Magnetic Resonance Diffusion Weighted Imaging

  • Cho, Ah Rang;Lee, Hae Kag;Yoo, Heung Joon;Park, Cheol-Soo
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.381-386
    • /
    • 2015
  • The purpose of this study is to improve diagnostic efficiency of clinical study by setting up guidelines for more precise examination with a comparative analysis of signal intensity and image distortion depending on the location of X axial of object when performing magnetic resonance diffusion weighted imaging (MR DWI) examination. We arranged the self-produced phantom with a 45 mm of interval from the core of 44 regent bottles that have a 16 mm of external diameter and 55 mm of height, and were placed in 4 rows and 11 columns in an acrylic box. We also filled up water and margarine to portrait the fat. We used 3T Skyra and 18 Channel Body array coil. We also obtained the coronal image with the direction of RL (right to left) by using scan slice thinkness 3 mm, slice gap: 0mm, field of view (FOV): $450{\times}450mm^2$, repetition time (TR): 5000 ms, echo time (TE): 73/118 ms, Matrix: $126{\times}126$, slice number: 15, scan time: 9 min 45sec, number of excitations (NEX): 3, phase encoding as a diffusion-weighted imaging parameter. In order to scan, we set b-value to $0s/mm^2$, $400s/mm^2$, and $1,400s/mm^2$, and obtained T2 fat saturation image. Then we did a comparative analysis on the differences between image distortion and signal intensity depending on the location of X axial based on iso-center of patient's table. We used "Image J" as a comparative analysis programme, and used SPSS v18.0 as a statistic programme. There was not much difference between image distortion and signal intensity on fat and water from T2 fat saturation image. But, the average value depends on the location of X axial was statistically significant (p < 0.05). From DWI image, when b-value was 0 and 400, there was no significant difference up to $2^{nd}$ columns right to left from the core of patient's table, however, there was a decline in signal intensity and image distortion from the $3^{rd}$ columns and they started to decrease rapidly at the $4^{th}$ columns. When b-value was 1,400, there was not much difference between the $1^{st}$ row right to left from the core of patient's table, however, image distortion started to appear from the $2^{nd}$ columns with no change in signal intensity, the signal was getting decreased from the $3^{rd}$ columns, and both signal intensity and image distortion started to get decreased rapidly. At this moment, the reagent bottles from outside out of 11 reagent bottles were not verified from the image, and only 9 reagent bottles were verified. However, it was not possible to verify anything from the $5^{th}$ columns. But, the average value depends on the location of X axial was statistically significant. On T2 FS image, there was a significant decline in image distortion and signal intensity over 180mm from the core of patient's table. On diffusion-weighted image, there was a significant decline in image distortion and signal intensity over 90 mm, and they became unverifiable over 180 mm. Therefore, we should make an image that has a diagnostic value from examinations that are hard to locate patient's position.

Efficacy of Self-manipulation Technique in the Treatment of Patients with Anterior Disc Displacement without Reduction (비정복성 관절원판 전방변위 환자의 치료에 있어서 자가 수조작술의 효과에 대한 연구)

  • Kim, Ju-Sik;Lee, Chae-Hoon;Kim, Young-Ku
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.4
    • /
    • pp.441-447
    • /
    • 2007
  • Internal derangement of the temporomandibular joint(TMJ) is defined as an abnormal relationship of the articular disc to the condyle. Mandibular manipulation is one of the conservative treatments to be considered first to manage the patients with anterior disc displacement without reduction. Mandibular manipulation is used to increase articular mobility and to restore the displaced disc into an anatomically normal position. While Farrar's technique has been popularly used, Minagi et al., Mongini and Suarez introduced the manipulation technique conducted by the patients themselves. But there is no study on the efficacy of self-manipulation technique, comparing with conventional one. The aim of this study was to investigate the efficacy of the conventional and self-manipulation technique, which was modified to complement the previously described technique by Minagi et al., in the treatment of patients with anterior disc displacement without reduction. TMD patients, who visited Department of Oral Medicine of Seoul National University Dental Hospital from December, 2002 to November, 2004 and were diagnosed as anterior disc displacement without reduction by TMJ magnetic resonance imaging (MRI) were enrolled. Conservative treatments including physical therapy, exercise, behavioral therapy, stabilization splint therapy, and manipulation therapy were done to every single patient until the symptomsimproved enough to discharge the patient. The charts were reviewed retrospectively according to the type of manipulation. In the results, patients whose maximum mouth opening was more than 40 mm was higher in the self-manipulation group(69.9%) than in the conventional manipulation group(42.9%). But difference between two groups was not significant. According to the fact that we decided to discharge the patients whentheir mouth opening increased to more than 40 mm and subjective symptoms such as pain and discomfort were improved as well, treatment period of discharged patients was significantly shorter in the self-manipulation group($29.2{\pm}12.3$ weeks) than in the conventional manipulation group ($61.0{\pm}38.0$ weeks) (p<0.01). In conclusion, in the treatment of TMD patients with anterior disc displacement without reduction, the self-manipulation technique which is performed by patients themselves is an effective treatment modality for increasing the range of mouth opening and shortening the total treatment period.

Preliminary Study on the MR Temperature Mapping using Center Array-Sequencing Phase Unwrapping Algorithm (Center Array-Sequencing 위상펼침 기법의 MR 온도영상 적용에 관한 기초연구)

  • Tan, Kee Chin;Kim, Tae-Hyung;Chun, Song-I;Han, Yong-Hee;Choi, Ki-Seung;Lee, Kwang-Sig;Jun, Jae-Ryang;Eun, Choong-Ki;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.131-141
    • /
    • 2008
  • Purpose : To investigate the feasibility and accuracy of Proton Resonance Frequency (PRF) shift based magnetic resonance (MR) temperature mapping utilizing the self-developed center array-sequencing phase unwrapping (PU) method for non-invasive temperature monitoring. Materials and Methods : The computer simulation was done on the PU algorithm for performance evaluation before further application to MR thermometry. The MR experiments were conducted in two approaches namely PU experiment, and temperature mapping experiment based on the PU technique with all the image postprocessing implemented in MATLAB. A 1.5T MR scanner employing a knee coil with $T2^*$ GRE (Gradient Recalled Echo) pulse sequence were used throughout the experiments. Various subjects such as water phantom, orange, and agarose gel phantom were used for the assessment of the self-developed PU algorithm. The MR temperature mapping experiment was initially attempted on the agarose gel phantom only with the application of a custom-made thermoregulating water pump as the heating source. Heat was generated to the phantom via hot water circulation whilst temperature variation was observed with T-type thermocouple. The PU program was implemented on the reconstructed wrapped phase images prior to map the temperature distribution of subjects. As the temperature change is directly proportional to the phase difference map, the absolute temperature could be estimated from the summation of the computed temperature difference with the measured ambient temperature of subjects. Results : The PU technique successfully recovered and removed the phase wrapping artifacts on MR phase images with various subjects by producing a smooth and continuous phase map thus producing a more reliable temperature map. Conclusion : This work presented a rapid, and robust self-developed center array-sequencing PU algorithm feasible for the application of MR temperature mapping according to the PRF phase shift property.

  • PDF

Assessment of the usefulness of the Machine Performance Check system that is an evaluation tools for the determination of daily beam output (일간 빔 출력 확인을 위한 평가도구인 Machine Performance Check의 유용성 평가)

  • Lee, Sang Hyeon;Ahn, Woo Sang;Lee, Woo Seok;Choi, Jin Hyeok;Kim, Seon Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.65-73
    • /
    • 2017
  • Purpose: Machine Performance Check (MPC) is a self-checking software based on the Electronic Portal Imaging Device (EPID) to measure daily beam outputs without external installation. The purpose of this study is to verify the usefulness of MPC by comparing and correlating daily beam output of QA Beamchecker PLUS. Materials and Methods: Linear accelerator (Truebeam 2.5) was used to measure 10 energies which are composed of photon beams(6, 10, 15 MV and 6, 10 MV-FFF) and electron beams(6, 9, 12, 16 and 20 MeV). A total of 80 cycles of data was obtained by measuring beam output measurement before treatment over five months period. The Pearson correlation coefficient was used to evaluate the consistency of the beam output between the MPC and the QA Beamchecker PLUS. In this study, if the Pearson correlation coefficient is; (1) 0.8 or higher, the correlation is very strong (2) between 0.6 and 0.79, the correlation is strong (3) between 0.4 and 0.59, the correlation is moderate (4) between 0.2 and 0.39, the correlation is weak (5) lower than 0.2, the correlation is very weak. Results: Output variations observed between MPC and QA Beamchecker PLUS were within 2 % for photons and electrons. The beam outputs variations of MPC were $0.29{\pm}0.26%$ and $0.30{\pm}0.26%$ for photon and electron beams, respectively. QA Beamchecker PLUS beam outputs were $0.31{\pm}0.24%$ and $0.33{\pm}0.24%$ for photon and electron beams, respectively. The Pearson correlation coefficient between MPC and QA Beamchecker PLUS indicated that photon beams were very strong at 15 MV, and strong at 6 MV, 10 MV, 6 MV-FFF and 10 MV-FFF. For electron beams, the Pearson correlation coefficient were strong at 16 MeV and 20 MeV, moderate at 9 MeV and 12 MeV, and very weak at 6 MeV. Conclusion: MPC showed significantly strong correlation with QA Beamchecker PLUS when testing with photon beams and high-energy electron beams in the evaluation of daily beam output, but the correlation when testing with low-energy electron beams (6 MeV) appeared to be low. However, MPC and QA Beamchecker PLUS are considered to be suitable for checking daily beam output, as they performed within 2 % of beam output consistency during the observation. MPC which can perform faster than the conventional daily beam output measurement tool, is considered to be an effective method for users.

  • PDF

Time Resolution Improvement of MRI Temperature Monitoring Using Keyhole Method (Keyhole 방법을 이용한 MR 온도감시영상의 시간해상도 향상기법)

  • Han, Yong-Hee;Kim, Tae-Hyung;Chun, Song-I;Kim, Dong-Hyeuk;Lee, Kwang-Sig;Eun, Choong-Ki;Jun, Jae-Ryang;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.31-39
    • /
    • 2009
  • Purpose : This study proposes the keyhole method in order to improve the time resolution of the proton resonance frequency(PRF) MR temperature monitoring technique. The values of Root Mean Square (RMS) error of measured temperature value and Signal-to-Noise Ratio(SNR) obtained from the keyhole and full phase encoded temperature images were compared. Materials and Methods : The PRF method combined with GRE sequence was used to get MR temperature images using a clinical 1.5T MR scanner. It was conducted on the tissue-mimic 2% agarose gel phantom and swine's hock tissue. A MR compatible coaxial slot antenna driven by microwave power generator at 2.45GHz was used to heat the object in the magnetic bore for 5 minutes followed by a sequential acquisition of MR raw data during 10 minutes of cooling period. The acquired raw data were transferred to PC after then the keyhole images were reconstructed by taking the central part of K-space data with 128, 64, 32 and 16 phase encoding lines while the remaining peripheral parts were taken from the 1st reference raw data. The RMS errors were compared with the 256 full encoded self-reference temperature image while the SNR values were compared with the zero filling images. Results : As phase encoding number at the center part on the keyhole temperature images decreased to 128, 64, 32 and 16, the RMS errors of the measured temperature increased to 0.538, 0.712, 0.768 and 0.845$^{\circ}C$, meanwhile SNR values were maintained as the phase encoding number of keyhole part is reduced. Conclusion : This study shows that the keyhole technique is successfully applied to temperature monitoring procedure to increases the temporal resolution by standardizing the matrix size, thus maintained the SNR values. In future, it is expected to implement the MR real time thermal imaging using keyhole method which is able to reduce the scan time with minimal thermal variations.

  • PDF