• Title/Summary/Keyword: self-field loss

Search Result 61, Processing Time 0.031 seconds

Measurement & Analysis of Transport Current AC loss in Coated Conductor Bifilar Structure (Coated Conductor의 Bifilar 구조에서의 통전 교류 손실 측정 및 해석)

  • Bang, J.S.;Park, D.K.;Sim, K.D.;Jang, K.S.;Yang, S.E.;Ahn, M.C.;Kang, H.K.;Seok, B.Y.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.22-26
    • /
    • 2007
  • Superconductor is weak in AC condition. Bifilar geometry provides a solution to reduce AC loss. Bifialr geometry is piled up or wound with more than two layers. When a layer of superconductor abuts on other layers, AC loss is affected by not only self-field, but also magnetic field induced by adjacent layers. In this study, two superconductors are piled up as a series connection so that current flows in different directions. By this method, magnetic field is cancelled. If magnetic field is cancelled, AC loss is reduced. To compare AC loss with respect to piling method, we measured the AC loss difference between the case facing each other with substrate side and the case facing with YBCO side. Measured AC loss is compared with one-way current flow single layer AC loss. In addition, we analyzed how much AC loss was increased, or reduced. All results were compared with those calculated with Norris equation. By this experiment, we concluded that distance between two wires is the important cause of AC loss. The distance between two wires affects magnetic field reduction in YBCO and induced current flow on substrate side.

A Comparative Study Between Diffusive-thermal and Buoyancy-driven Self-excitations in Laminar Free Jet Flames with Applied DC Electric Fields (직류전기장이 인가된 층류제트화염에서 물질 -열 확산과 부력에 의한 진동비교에 관한 연구)

  • Han, Jong-Kyu;Yoon, Sung-Hwan;Park, Jeong;Kwon, Oh-Boong;Kim, Tae-Hyung;Park, Jong-Ho
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.1
    • /
    • pp.37-47
    • /
    • 2012
  • Experimental study on comparison of diffusive-thermal self-excitation with buoyancy-driven one due to accumulation of partially premixed, preheated mixture in front of edge flame was conducted in horizontally and vertically injected laminar free-jet flames with an applied DC electric field of -10 kV. The application of horizontal injection method with the DC electric field to jet flames was experimentally designed to suppress heat-loss-induced self-excitation and thereby to highlight the definite difference between both diffusive-thermal and buoyancy-driven self-excitations with the same order of O(1.0 Hz), in that diffusive-thermal self-excitation has not been so far found experimentally in laminar jet flames. Flame stability maps in vertically and horizontally injected jet flames are presented. The distinct modes of individual self-excitation are shown to be well described by their own phase diagrams. The results show that buoyancy-driven self-excitation due to the accumulation of partially premixed, preheated mixtures in front of edge flame is branched from the buoyancy-induced self-excitation with O(10 Hz) due to a flame flicker. Once the buoyancy-driven self-excitation appears, it suppresses buoyancy-induced as well as diffusive-thermal self-excitation. The key characteristics for individual self-excitation are discussed and their functional dependencies of Strouhal number upon related physical parameters are also presented.

A Study of Characteristic of Electrical-magnetic and Neutron Diffraction of Long-wire High-superconductor for Reducing Energy Losses

  • Jang, Mi-Hye
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.6
    • /
    • pp.265-272
    • /
    • 2008
  • In this paper, AC losses of long wire Bi-2223 tapes with different twist pitch of superconducting core were fabricated, measured and analyzed. These samples produced by a powder-in-tube method are multi-filamentary tape with Ag matrix. Also, it's produced by non-twist. The critical current measurement was carried out under the environment in Liquid nitrogen and in zero field by 4-prob method. And the Magnetic measurement was carried out under the environment of applied time-varying transport current by transport method. From experiment, the susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation. Neutron-diffraction measurements have been carried out investigate the crystal structure, magnetic structures, and magnetic phase transitions in Bi-2223([Bi, Pb]:Sr:Ca:Cu:O).

AC Loss Characteristics of Technical High-$T_{c}$ Superconducting Tapes (실용 고온 초전도테이프의 교류손실 특성)

  • 김현준;허대행;조영호;류경우;최병주
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.11-14
    • /
    • 2003
  • The magnetization and self-field losses of the four technical high-T$_{c}$ superconducting tapes have been investigated experimentally. The results show that the magnetization losses for parallel or perpendicular fields can be well predicted from the slab model or the strip model for a filamentary region. However the magnetization losses for longitudinal fields can be rather predicted by the slab model for a decoupled filament. The self-field losses are well explained by the Norris ellipse model.l.

  • PDF

The Design and Manufature by Analysis of AC Loss of high temperature supercondutor wire of Ag-sheath Bi-2223 (Ag-sheath Bi-2223 고온 초전도 선재 AC 손실 해석에 따른 설계 및 제작)

  • Jang, Mi-Hae;Chu, Yong;Lee, Joon-Young;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.349-352
    • /
    • 1998
  • In future superconducting electrical machines and device. AC loss in the superconducting windings are one of the most impotent design paramenters. This paper descriptions a series of Characteristic of a high-Tc superconducting Bi-Pb-Sr-Ca-Cu-O Ag-sheathed filament. In the case simulation and design to reduce ac loss is considered the filament number, twitch pith number and diameter of filament. A filament sample with Tc of 78K is made by $835^{\circ}C$ sintering for 50h and $0.33^{\circ}C$/min heating rate in an atmosphere. The experiment observations are compared with self-field loss and AC losses of Bi-Pb-Sr-Ca-Cu-O filament at 77K in following environments ; (i)AC external parallel magnetic field in different frequencies. And an analytical expression of the loss the derivation of transposition from an optimum condition was derived for the external AC magnetic field, theoretical predictions were found to coincide with the experimental observations.

  • PDF

10kVA high $T_c$ Superconducting Power Transformer with Double Pancake Windings (더블팬케이크 권선형 10kVA 고온초전도 변압기)

  • Lee, Hui-Jun;Cha, Gwi-Su;Lee, Ji-Gwang;Han, Song-Yeop;Ryu, Gyeong-U;Choe, Gyeong-Dang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.2
    • /
    • pp.65-72
    • /
    • 2001
  • This paper presents the design and test results of a 10kVA single phase HTS transformer which is operating at 77K. Double pancake windings with BSCCO -2223 HTS tape and GFRP cryostat with room temperature bore are used in the transformer. Four double pan cake windings were used in pancake windings are connected in parallel to conduct the secondary current of 45.4A. the rated voltages of each winding are 440/220V. Numerical calculation using Finite Element Method was used to evaluated the performance of each arrangement. Considering the magnetizing reactance, leakage reactance, electrical insulation and the circulating current in low voltage winding which had two windings in parallel, HLLH arrangement was finally chosen. Estimation of the AC loss, magnetizing loss and self field loss, in the design stage, where effects of perpendicular field and parallel field are considered. Room temperature bore type cryostat has been constructed and its heat loss was measured.

  • PDF

Fabrication, AC Loss Measurement and Analysis of Bi-2223 Conductors with Respect to Various Twist Pitch (트위스트 피치를 고려한 Bi-2223 선재 제작과 AC 손실 측정 및 분석)

  • Jang, Mi-Hye;Chu, Yong;Lim, Jun-Hyung;Joo, Jin-Ho;Ko, Tae-Kuk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.11
    • /
    • pp.589-595
    • /
    • 2000
  • In this papre, AC losses of Bi-2223 tapes with different twist pitch of superconducting core were fabricated, measured and analyzed. These samples produced by a powder-in-tube method are multi-filamentary tape with Ag matrix. Also, it's produced by non-twist and different twist pitch(8, 10, 13, 30, 50, 70 mn). The critical current measurement was carried out under the environment in Liquid nitrogen and in zero field by 4-probe method. And the AC loss measurement was carried out under the environment of applied time-varying transport current by transport method. From experiment, the critical current is larger non-twist than twisted filament. And, the AC loss by Norris equation is higher non-twisted tape than 13mm twisted tape. Also, it is confirmed that of AC loss of tape having non-twist pitch larger than those having differnet twist pitch.

  • PDF

A Study on the Development of Lightweight Wall for Sound Transmission Loss and Field Test Results of the Dry-Wall System (차음성능이 향상된 경량벽체 개발 및 성능평가 연구)

  • 이병권;배상환;홍천화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.699-704
    • /
    • 2004
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings, it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But, the required performances of a light-weight wall are not evaluated systematically. As a field survey result, partition walls of house-to-house were not showed their respected performances, so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially, occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings. As a result, a new drywall system was presented and the performance was verified with field test.

  • PDF

Transport current Losses of the HTS Stacked Tapes at Various Gap between Tapes (고온초전도 적층선재에서의 층간 거리에 따른 전송전류 손실)

  • 임형우;이승욱;이희준;차귀수;이지광
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.254-256
    • /
    • 2003
  • AC loss is one of the important superconducting power machine that we have to consider deeply using the stack wires with the HTS. AC magnetic field is occurred around the wires when the electric current is conducted to the stack wires. It also brings electric field to the wires and occurs self field loss, whose quantity is appeared differently by distance of the stack wires. In this paper, transport current losses of a stack short sample of HTS were compared with Norris equation and measured value.

  • PDF

Concentric-Circle-Grating Surface Emitting (CCGSE)-DFB Laser with second order grating (Second order grating CCGSE-DFB 레이저 해석)

  • 박해령;김효창;이연호
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.313-316
    • /
    • 2000
  • Concentric-Circle-Grating (CCG) cavity is analyzed by coupled mode theory. In this case concentric grating is acting as both feedback element and output coupler. In our calculations radiation loss terms are included in guided coupled mode equations. The surface-emitted field distribution is obtained in self-consistent manner.

  • PDF