• Title/Summary/Keyword: self-Inspection

Search Result 275, Processing Time 0.024 seconds

A Survey on the Sanitary Condition of Kitchens of School Lunch Program

  • Kim, Jong-Gyu
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.174-176
    • /
    • 2003
  • A survey was conducted to investigate the sanitary condition of school kitchens in one region of Korea. A self-administered questionnaire recommended by the Korea Ministry of Education & Human Resources Development (MOEHRD) was offered to a random sample of dieticians of twenty-five elementary schools for food, sanitation and safety inspection of their kitchens. Air temperature, relative humidity, and airborne microbes in the kitchens were monitored during food preparation, processing and service. The inspection results showed their sanitary condition met the level B of the recommendation of the Korea MOEHRD. The range of air temperature of the kitchens was 21.4∼22.4$^{\circ}C$, and the range of relative humidity was 62.4∼69.6%. The microbiological evaluation of kitchen samples indicated aerobic plate count levels from 22.5 to 26.5 CFU/15 min. These results indicate that the levels of sanitary condition of kitchens in the schools were not satisfactory for safe foodservice although the inspection showed good results. This study suggests that the school kitchens should be monitored and strict inspection is necessary.

  • PDF

A Survey on the Sanitary Condition of Kitchens in School Food-service Programs (일부 학교급식소 조리실의 위생관리에 관한 조사연구)

  • 김종규
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.2
    • /
    • pp.87-93
    • /
    • 2003
  • A survey including an inspection was conducted to assess the sanitary condition of kitchens in the school food-service programs and to prepare background data for improving the safety of school meals. The survey was carried out over a two-month period (September-October, 2001). A self-administered questionnaire recommended by the Korea Ministry of Education & Human Resources Development (MOEHRD) was offered to a random sample of dieticians of twenty-five elementary schools in one region of Korea about food, sanitation, and safety inspection of their kitchens. Air temperature, relative humidity, and airborne microbes in the kitchens were monitored during preparation, cooking, and service. The inspection results showed their sanitary rendition met the level B of the recommendation of the Korea MOEHRD. The range of air temperature of the kitchens was 21.4~22.4$^{\circ}C$. and the range of relative humidity was 62.4~69.6%. The microbiological evaluation of kitchen samples indicated aerobic plate count levels from 22..5 to 26.5 CFU/15 minutes. Although the results of inspection show that the levels of sanitary condition of kitchens in the schools were good, they are not satisfactory for safe food-servile because the temperature and humidity levels are high. This study indicates that the school kitchens should be monitored and strict inspection is necessary. The legal standards for school food-service should include standards for kitchen air temperature, relative humidity, and airborne microbes.

A Case Study of Quality Assurance and Control for the Soil Environmental Assessment in Abandoned Mine (광산지역 토양정밀조사 정도관리(QA/QC) 사례 연구)

  • Ji, Won Hyun;Kim, Jong Keun
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.134-141
    • /
    • 2014
  • A testing inspection is one of the important in the industry, owing to determine the reliability and directivity of testing inspection results. Therefore, the quality assurance and quality control (QA/QC) work which performed by personnel not directly in the inventory compilation development, in testing inspection must be thoroughly considered. Some agencies for environmental test inspection, they sometimes misunderstood that the QA/QC was ended with proficiency testing performance and on-site assessment by a director. Thus, results were often calculated without QA/QC work by self manual when conducting test. The objective of this study was to improve reliability of testing and inspection agency through the QA/QC case study which basically performed to raising reliability of testing and inspection agency. In this study, it increased reliability of result by verifying calibration curve (IC, ICV, CCV), blank, accuracy (LCS, MS) and precision as QA/QC performance, while performing investigation of soil contamination in mining areas. This study suggests that reliability establishing method of test result and management method of analysis process, through the QA/QC instance of testing agency.

A Study on Crack Healing Properties of Cement Composites Mixed with Self-healing Microcapsules (자기치유 마이크로 캡슐을 혼합한 시멘트 복합재료의 품질 및 균열 치유 특성에 관한 실험적 연구)

  • Choi, Yun-Wang;Oh, Sung-Rok;Kim, Cheol-Gyu;Nam, Eun-Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.113-121
    • /
    • 2019
  • In this study, self - healing microcapsules which can be mixed directly with cement composites were prepared, and the quality and crack healing performance of cement composites with self - healing microcapsules were evaluated. In the past, it has been focused on evaluating self-healing capsules and crack healing properties. Therefore, self - healing microcapsules have been studied for their effect on the quality of cement composites when mixed with cement composites. The table flow and the air flow rate of the cement composite material mixed with self-healing microcapsules were found to have no significant influence on table flow and air volume regardless of mixing ratio. Compressive strength and splitting tensile strength tended to decrease with increasing capsule mixing ratio. As a result of evaluation of crack healing properties according to water flow, initial water permeability decreased, and reaction products were generated over time and cracks were healed.

A Study on the Self-Diagnosis Criteria of Electrical Installations (자가용 전기설비의 자가진단 기준에 대한 연구)

  • Kim, Jong-Min;Lee, Hyeon-Woo;Kim, Hong-Ki;Yoo, Sang-Bong;Jang, Kyung-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.5
    • /
    • pp.863-869
    • /
    • 2017
  • This paper is to enable electrical safety manager to have more objective evaluation on the safety by indicating quantitative values such as life-time and status quotient of daily visual inspection on private electrical equipments. Self-diagnosis table is recommended to apply such a evaluation efficiently according to the characteristics of each electrical equipments, and the managers's determination of the precise inspection, replacement etc. will be also possible through the standard selected by various domestic and foreign data with expert's advise for numerical evaluation. This circumstance will be able to establish the foundation to secure the soundness of electrical equipments.

Instructional Design of Self-directed Information Communication Ethics Education based on the UCC Dramatization Learning (UCC 활용 극화학습 기반 자기주도적 정보통신윤리교육 수업 설계)

  • Kim, Hyun-Bae;Mun, Jeong-Hee
    • Journal of The Korean Association of Information Education
    • /
    • v.14 no.4
    • /
    • pp.561-570
    • /
    • 2010
  • In recent years, we can see attempts to take advantage of UCC in a way of the education. But in the precedent studies there are not many guidance plans to help teachers apply UCC in the classroom. The purpose of this paper is to suggest a guidance plan to help teachers apply UCC in the classroom and to analyze the effect of educational using UCC Dramatization learning model on the expanding of students' self-directed learning ability in the information communication ethics education. For this, first, a teacher executes preliminary inspection about self-directed learning ability second, students study about "how to prevent them from cyber crime" using UCC Dramatization learning model. Third a teacher executes post inspection about self-directed learning ability and measures the degree of improvement on self-directed learning ability. The final step is to extract the implications from the analysis of the experiments.

  • PDF

Evaluation of Crack Self-healing Performance in Centrifugal Molding Concrete by Permeability Test (원심성형 콘크리트의 투수시험을 통한 균열 자기치유 성능평가)

  • Hwang, Chul Sung;Woo, Hae Sik;Choi, Young Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.3
    • /
    • pp.84-89
    • /
    • 2018
  • Recently, study on self-healing materials have been performed to increase the life by repairing the damage of structures themselves, which are difficult to repair or require high maintenance costs. A water permeability test has been widely used for the evaluation of self-healing performance. However, in the self-healing performance test method, the initial crack width of the concrete greatly affects on the self-healing performance but it does not have a consistent standard. Therefore, in this study, the correlation between crack and permeability and that between time and permeability were analyzed based on crack width and permeability. In addition, since the initial crack width measured by optical microscope is not reliable, the value is derived from the Poiseuille flow and the tendency of time-permeability and time-crack width are analyzed.

An Experimental Study on the Self-Healing Performance of Solid Capsules According to the Composition Ratio of Crystal Growth Type Inorganic Materials (결정성장형 무기재료 조성비에 따른 고상 캡슐의 자기치유 성능에 관한 실험적 연구)

  • Nam, Eun-Joon;Oh, Sung-Rok;Kim, Cheol-Gyu;Choi, Yun-Wang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.2
    • /
    • pp.16-22
    • /
    • 2021
  • In this paper, a solid capsule was prepared using a crystal growth type inorganic material capable of hydration reaction. The solid capsules were mixed at 3, 5, and 10% according to the composition ratio of 8:2, 7:3, 6:4 based on the cement mass, and the self-healing mortar was mixed, Durable healing properties were evaluated through the water permeability test. As a result of the water level permeability test, the effect of optimally improving the natural healing performance was shown by mixing the solid capsules prepared in a composition ratio of 7:3 of the solid capsules. In the case of a crack width of 0.3mm or less, it is estimated that more than 90% of the self-healing performance can be secured. As a result, it was judged that the self-healing performance of the solid capsule had an effect on the durable healing properties through the water permeability test, It is judged that there is a tendency to improve self-healing performance according to the mixing of solid capsules.

An Experimental Study to Evaluate the Flexural Performance of Steel Fiber-Reinforced Self-Compacting Concrete (강섬유를 보강한 자기충전 콘크리트의 휨 성능 평가를 위한 실험 연구)

  • Park, Yon-Dong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.6 s.58
    • /
    • pp.166-175
    • /
    • 2009
  • An experimental study was carried out to estimate the flexural performance of steel fiberreinforced self-compacting concrete. Seven slabs with three different steel fiber-reinforced concretes were prepared to make beam specimens. After proper curing period, each slab was cut to five beams with a diamond saw. The beam specimen was tested with displacement control method to obtain load-deflection curve. As the results, the self-compacting concrete beam showed higher flexural strength, ductility and toughness index compared to the normal concrete beam. This means that steel fiber-reinforced self-compacting concrete can be used more widely in the field of architecture and civil engineering because of its self-compactability and good mechanical properties.

Pipeline Defects Detection Using MFL Signals and Self Quotient Image (자기 누설 신호와 SQI를 이용한 배관 결함 검출)

  • Kim, Min-Ho;Rho, Yong-Woo;Choi, Doo-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.311-316
    • /
    • 2010
  • Defects positioning of underground gas pipelines using MFL(magnetic flux leakage) inspection which is one of non-destructive evaluation techniques is proposed in this paper. MFL signals acquired from MFL PIG(pipeline inspection gauge) have nonlinearity and distortion caused by various external disturbances. SQI(self quotient image), a compensation technique for nonlinearity and distortion of MFL signal, is used to correct positioning of pipeline defects. Through the experiments using artificial defects carved in the KOGAS pipeline simulation facility, it is found that the performance of proposed defect detection is greatly improved compared to that of the conventional DCT(discrete cosine transform) coefficients based detection.