• Title/Summary/Keyword: selective scan

Search Result 72, Processing Time 0.026 seconds

A Study on Generation of Laser Scanning Path and Scanning Control (레이저 주사 경로 생성 및 주사 제어에 관한 연구)

  • 최경현;최재원;김대현;도양회;이석희;김성종;김동수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1295-1298
    • /
    • 2004
  • Selective Laser Sintering(SLS) method is one of Rapid Prototyping(RP) technologies. It is used to fabricate desirable part to sinter powder and stack the fabricated layer. To develop this SLS machine, it needs effective scanning path and the development of scanning device. This paper shows how to make fast scanning path with respect to scan spacing, laser beam size and scanning direction from 2-dimensional sliced file generated in commercial CAD/CAM software. Also, we develop the scanning device and its control algorithm to precisely follow the generated scanning path. Scanning path affects precision and total machining time of the final fabricated part. Sintering occurs using infrared laser which has high thermal energy. As a result, shrinkage and curling of the fabricated part occurs according to thermal distribution. Therefore, fast scanning path generation is needed to eliminate the factors of quality deterioration. It highly affects machining efficiency and prevents shrinkage and curling by relatively lessening the thermal distribution of the surface of sintering layer. To generate this fast scanning path, adaptive path generation is needed with respect to the shape of each layer, and not simply x, y scanning, but the scanning of arbitrary direction must be enabled. This paper addresses path generation method to focus on fast scanning, and development of scanning system and control algorithm to precisely follow generated path.

  • PDF

Predictive Markers for Screening Renal Damage in Children with Urinary Tract infections and Vesicoureteral Reflux

  • Lee, Hyeonju;Choi, Jae Hong;Kang, Dong-Hyeok;Kim, Seunghyo;Kang, Ki-Soo;Han, Kyoung Hee
    • Childhood Kidney Diseases
    • /
    • v.24 no.1
    • /
    • pp.27-35
    • /
    • 2020
  • Purpose: Urinary tract infections (UTIs) are the most common and serious bacterial infections in children. Therefore, early diagnosis of vesicoureteral reflux (VUR) for treatment planning and the identification of noninvasive markers that can predict renal injury are important in patients with UTIs. We analyzed the clinical features of pediatric UTIs commonly encountered by general practitioners and reinterpreted the blood tests and imaging findings to identify the important clinical predictive markers of VUR in order to selectively perform VCUG. Methods: This retrospective study was performed among 183 children diagnosed with a UTI or acute pyelonephritis. Results: The most significant predictor of high grade and bilateral VUR identified using area under the curve analyses was hydronephrosis on kidney ultrasound images with renal cortical defects on dimercaptosuccinic acid (DMSA) kidney scan simultaneously, followed by hydronephrosis only on kidney ultrasound. Conclusion: The presence of hydronephrosis on kidney ultrasound images or cortical defects or asymmetric kidneys on the DMSA kidney scans can be predictive markers of VUR, reducing the need for VCUG. Our study can thus help minimize the exposure to radiation among patients through selective VCUG.

A Case of Giant Papillary Thyroid Carcinoma Resection with Massive Intraoperative Bleeding (술 중 대량 출혈을 동반한 거대 갑상선유두상암종 절제술 1례)

  • Kim, Seok Hyun;Jung, Jae Hwan;Sung, Eui Suk;Lee, Jin Choon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.33 no.1
    • /
    • pp.85-89
    • /
    • 2017
  • A 62-year-old female patient had goiter for twenty years. She visited out-patient clinic with a hoarse voice and intermittent breathing difficulties. About protruding 15cm sized mass located the anterior neck and right vocal cord paralysis was observed. Preoperative CT scan was strongly suspected of thyroid gland cancer and cervical lymph node metastasis. Therefore, fine needle aspiration test was performed and surgical treatment was planned with the histopathologic results (papillary thyroid carcinoma). Surgery was performed with total thyroidectomy, bilateral cervical lymph node dissection, and right selective nodal lymph node dissection (level II-V). During operation right thyroid seemed to be adherent to surrounding tissue and the blood vessels were extremely engorged. There was hypotensive crisis because of intraoperative excessive bleeding. However it was managed by repetitive transfusion. The operation was completed without abnormalities. She underwent 4 times of bleeding control operation due to postoperative bleeding. After complications were improved, we are currently undergoing out-patient follow up without morbidity.

Lung Metastasis of Thyroid Papillary Carcinoma which was Temporarily Treated for Milliary Tuberculosis (파종성 폐결핵으로 오인된 갑상선 유두상암종의 폐전이)

  • Na, Hong-Shik;Lee, Je-Hyuck;Paeng, Jae-Pil;Jung, Kwang-Yoon;Choi, Jong-Ouck
    • Korean Journal of Bronchoesophagology
    • /
    • v.6 no.1
    • /
    • pp.16-20
    • /
    • 2000
  • The patient a 24-year-old male, was shown to have milliary shadows on chest radiographs from the age of 20. He was temporarily treated for pulmonary tuberculosis without success. He had left thyroid mass and lymph node metastases in neck CT scan which was taken after admission but fine needle aspiration result in scanty cellularity. He underwent total thyroidectomy with left modified radical neck dissection and right selective neck dissection under the impression of differentiated thyroid cancer with bilateral neck metastases. Then he underwent 131I ablation treatment and postoperative whole body 131I scintigraphy revealed diffuse intensive uptake in the bilateral lung fields, demonstrating that the pulmonary lesions were metastases of the thyroid cancer.

  • PDF

A study about sculpture characteristic of SKD61 tool steel fabricated by selective laser melting(SLM) process (SLM 공정으로 제작된 SKD61 공구강의 조형 특성에 관한 연구)

  • Yun, Jaecheol;Choe, Jungho;Kim, Ki-Bong;Yang, Sangsun;Yang, Dong-Yeol;Kim, Yong-Jin;Lee, Chang-Woo;Yu, Ji-Hun
    • Journal of Powder Materials
    • /
    • v.25 no.2
    • /
    • pp.137-143
    • /
    • 2018
  • In this study, two types of SKD61 tool-steel samples are built by a selective laser melting (SLM) process using the different laser scan speeds. The characteristics of two kinds of SKD61 tool-steel powders used in the SLM process are evaluated. Commercial SKD61 tool-steel power has a flowability of 16.68 sec/50 g and its Hausner ratio is calculated to be 1.25 by apparent and tapped density. Also, the fabricated SKD61 tool steel powder fabricated by a gas atomization process has a flowability of 21.3 sec/50 g and its Hausner ratio is calculated to be 1.18. Therefore, we confirmed that the two powders used in this study have excellent flowability. Samples are fabricated to measure mechanical properties. The highest densities of the SKD61 tool-steel samples, fabricated under the same conditions, are $7.734g/cm^3$ (using commercial SKD61 powder) and $7.652g/cm^3$ (using fabricated SKD61 powder), measured with Archimedes method. Hardness is measured by Rockwell hardness testing equipment 5 times and the highest hardnesses of the samples are 54.56 HRC (commercial powder) and 52.62 HRC (fabricated powder). Also, the measured tensile strengths are approximately 1,721 MPa (commercial SKD61 powder) and 1,552 MPa (fabricated SKD61 powder), respectively.

Mechanical Property Improvement of the H13 Tool Steel Sculptures Built by Metal 3D Printing Process via Optimum Conditions (금속 3D 프린팅 공정 최적화를 통한 H13 공구강 조형체의 기계적 특성 향상)

  • Yun, Jaecheol;Choe, Jungho;Lee, Haengna;Kim, Ki-Bong;Yang, Sangsun;Yang, Dong-Yeol;Kim, Yong-Jin;Lee, Chang-Woo;Yu, Ji-Hun
    • Journal of Powder Materials
    • /
    • v.24 no.3
    • /
    • pp.195-201
    • /
    • 2017
  • In this study, H13 tool steel sculptures are built by a metal 3D printing process at various laser scan speeds. The properties of commercial H13 tool steel powders are confirmed for the metal 3D printing process used: powder bed fusion (PBF), which is a selective laser melting (SLM) process. Commercial H13 powder has an excellent flowability of 16.68 s/50 g with a Hausner ratio of 1.25 and a density of $7.68g/cm^3$. The sculptures are built with dimensions of $10{\times}10{\times}10mm^3$ in size using commercial H13 tool steel powder. The density measured by the Archimedes method is $7.64g/cm^3$, similar to the powder density of $7.68g/cm^3$. The hardness is measured by Rockwell hardness equipment 5 times to obtain a mean value of 54.28 HRC. The optimum process conditions in order to build the sculptures are a laser power of 90 W, a layer thickness of $25{\mu}m$, an overlap of 30%, and a laser scan speed of 200 mm/s.

Constructing Database for Drugs and its Application to Biological Sample by HPTLC and GC/MS (HPTLC와 GC/MS를 이용한 의약품의 데이타베이스화 및 생체시료에의 응용)

  • Yoo, Young-Chan;Park, Sung-Woo;Lim, Mie-Ae;Baeck, Seung-Kyung;Park, Seh-Youn;Lee, Ju-Seon;Lho, Dong-Seok
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.136-150
    • /
    • 2000
  • For the identification of unknown drugs in biological samples, we attempted rapid high performance thin layer chromatographic method which is sensitive and selective chromatographic analysis of high performance thin layer chromatography (HPTLC) with automated TLC sampler and ultra-violet (UV) scanner. We constructed HPTLC database (DB) on two hundred five drugs by using the data of Rf values and UV spectra (scan 200-360 nm) as well as gas chromatography/mass spectrometry (GC/MS) DB on ninety six drugs by using the data of relative retention time (RRT) on lidocain and mass spectra. After extracting drugs in biological sample by solid phase extraction (Clean Screen ZSDAU020), we applied them to HPTLC and GC/MS DB. Drugs, especially extracted from biological samples, showed good matching ratio to HPTLC DB and these drugs were confirmed by GC/MS. In conclusion, this DB system is thought to be very useful method for the screening of unknown drugs in biological samples.

  • PDF

Differential Pulse Voltammetric Determination of Co(II) Ion with a Chemically Modified Carbon Paste Electrode Containing ${\iota}$ -Sparteine (${\iota}$ -Sparteine으로 변성된 Carbon Paste 전극을 사용한 Co(II) 이온의 펄스 차이 전압-전류법 정량)

  • Eu-Duck Jeong;Mi-Sook Won;Deog-Su Park;Yoon-Bo Shim;Sung-Nak Choi
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.10
    • /
    • pp.881-887
    • /
    • 1993
  • A cobalt(II) ion-selective carbon-paste electrode (CPE) was constructed with ${\iota}$-sparteine. Cobalt(II) ion in aqueous solution was chemically deposited through the complexation with ${\iota}$-sparteine onto the CPE. The surface of CPEs were characterized by cyclic voltammetry and differential pulse voltammetry in an acetate buffer solution, separately. Exposure of the CPEs to an acid solution could regenerate surface to reuse it for the deposition. In more than 5 deposition / measurement / regeneration cycles, the response was reproducible and linear up to $5.0{\times}10^{-6}$M with linear sweep voltammetry. The peaks at 0.17V / 0.27V were correspond to the redox of Co(II)-SP complex deposited on CPE. The anodic peak of which appeared after scan over the cathodic peak of 0.17 V to more negative scan. In case of using the differencial pulse voltammetry (DPV), we have obtained the linear response $2.0{\times}10^{-7}$M with relative standard deviation ${\pm}5.6%$. The detection limit was $1.0{times}10^{-7}$M for 20 minutes of the deposition. We have also investigated the interference effect of various metal ions, which are expected to form the complex with the ligand on the electrode.

  • PDF

A Study to Recover Si from End-of-Life Solar Cells using Ultrasonic Cleaning Method (초음파 세척법을 이용한 사용 후 태양광 셀로부터 Si 회수 연구)

  • Lee, Dong-Hun;Go, Min-Seok;Wang, Jei-Pil
    • Resources Recycling
    • /
    • v.30 no.5
    • /
    • pp.38-48
    • /
    • 2021
  • In this study, we determine the optimal process conditions for selectively recovering Si from a solar cell surface by removal of impurities (Al, Zn, Ag, etc.). To selectively recover Si from solar cells, leaching is performed using HCl solution and an ultrasonic cleaner. After leaching, the solar cells are washed using distilled water and dried in an oven. Decompression filtration is performed on the HCl solution, and ICP-OES (Inductively Coupled Plasma Optical Emission spectroscopy) full scan analysis is performed on the filtered solution. Furthermore, XRD (X-ray powder diffraction), XRF (X-ray fluorescence), and ICP-OES are performed on the dried solar cells after crushing, and the purity and recovery rate of Si are obtained. In this experiment, the concentration of acid solution, reaction temperature, reaction time, and ultrasonic intensity are considered as variables. The results show that the optimal process conditions for the selective recovery of Si from the solar cells are as follows: the concentration of acid solution = 3 M HCl, reaction temperature = 60℃, reaction time = 120 min, and ultrasonic intensity = 150 W. Further, the Si purity and recovery rate are 99.85 and 99.24%, respectively.

Image Evaluation Analysis of CT Examination for Pedicle Screw Insertion (척추경 나사못 삽입술 CT검사의 영상평가 분석)

  • Hwang, Hyung-Suk;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.131-139
    • /
    • 2022
  • The purpose of this study was to insert a pedicle screw into a pig thoracic vertebrae, a general CT scan(Non MAR), and a thoracic axial image obtained with the Metallic Artifact Reduction for Orthopedic Implants (O-MAR) to reduce artifacts. The image obtained by reconstructing the algorithm (Standard, Soft, Bone, Detail) was used using the image J program. Signal to noise ratio(SNR) and contrast to noise ratio(CNR) were compared and analyzed by obtaining measured values based on the given equation. And this study was to investigate tube voltage and algorithm suitable for CT scan for thoracic pedicle screw insertion. As a result, when non-MAR was used, the soft algorithm showed the highest SNR and CNR at 80, 100, 120, and 140 kVp, On the other hand, when MAR was used, the standard algorithm showed the highest at 80 kVp, and the standard and soft algorithms showed similar values at 100 kVp. At 120 kVp, the Soft and Standard algorithms showed similar values, and at 140 kVp, the Soft algorithm showed the highest SNR and CNR. Therefore, when comparing Non-MAR and MAR, even if MAR was used, SNR and CNR did not increase in all algorithms according to the change in tube voltage. In conclusion, it is judged that it is advantageous to use the Soft algorithm at 80, 100, 120, and 140 kVp in Non MAR, the Standard algorithm at 80 and 100 kVp in MAR, and the Soft algorithm at 120 and 140 kVp. This study is expected to serve as an opportunity to further improve the quality of images by using selective tube voltage and algorithms as basic data to help evaluate images of pedicle screw CT scans in the future.