• 제목/요약/키워드: seismic-resistant structures

검색결과 155건 처리시간 0.031초

고층건물 내진설계기법의 개선 (IMPROVED EARTHQUAKE RESISTANT DESIGN OF MULTISTORY BUILDING FRAMES)

  • Lee, Dong-Guen-;Lee, Seok-Youn-
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1991년도 봄 학술발표회 논문집
    • /
    • pp.72-78
    • /
    • 1991
  • An improved procedure for earthquake resistant design of multistory building structures is proposed in this study. The effect of gravity load on seismic response of structures is evaluated through nonlinear dynamic analyses of a single story example structure. The presence of gravity load tends to initiate plastic hinge formation in earlier stage of a strong earthquake. However, the effect of gravity load seems to disapper as ground motion is getting stronger. And one of shortcomings in current earthquake resistant codes is overestimation of gravity load effects when earthquake load is applied at the same time so that it may leads to less inelastic deformation or structural damage in upper stories, and inelastic deformation is increased in lower stories. Based on these observation, an improved procedure for earthquake resistant design is derived by reducing the factor for gravity load and inceasing that for seismic load. Structures designed by the proposed design procedure turned out to have increased safety and stability against strong earthquakes.

  • PDF

지진을 고려한 비탈면 설계 방안 (Earthquake Resistant Design Methods on the Slopes)

  • 김주형;이용수;조삼덕
    • 한국방재학회 논문집
    • /
    • 제5권1호
    • /
    • pp.23-32
    • /
    • 2005
  • 1995년 일본 고베 대지진 발생 이후 한국정부는 국내 시설물에 대한 내진설계분야 및 지진피해 최소화 방안에 대한 연구를 지속적으로 진행해왔으며, 현재까지 괄목할 만한 많은 성과를 내고 있다. 그렇지만, 국내비탈면과 같은 구조물들은 여전히 내진설계가 적용되지 않고 있으며, 일부 기관에서만 설계자의 판단에 의해 비탈면 내진설계가 적용되고 있는 실정이다. 본 연구에서는 국내외 비탈면 내진설계에 대한 연구 결과를 소개하고 국내비탈면에 적용할 수 있는 내진설계 방안을 제시하였다. 비탈면 내진설계 적용범위는 경제성, 비탈면의 중요도 및 복구의 용이성 등을 고려하여 공학자가 내진설계 여부를 판단하도록 하는 것이 바람직하며, 우리나라 비탈면의 내진설계 적용 범위 및 관련 기준도 지진관련 자료를 축적하여 향후 단계적으로 정립하는 것이 바람직 할 것으로 판단된다.

Seismic performance evaluation of RC bearing wall structures

  • Rashedi, Seyed Hadi;Rahai, Alireza;Tehrani, Payam
    • Computers and Concrete
    • /
    • 제30권2호
    • /
    • pp.113-126
    • /
    • 2022
  • Reinforced concrete bearing walls (RCBWs) are one of the most applicable structural systems. Therefore, vulnerability analysis and rehabilitation of the RCBW system are of great importance. In the present study, in order to the more precise investigation of the performance of this structural resistant system, pushover and nonlinear time history analyses based on several assumptions drawing upon experimental research were performed on several models with different stories. To validate the nonlinear analysis method, the analytical and experimental results are compared. Vulnerability evaluation was carried out on two seismic hazard levels and three performance levels. Eventually, the need for seismic rehabilitation with the basic safety objective (BSO) was investigated. The obtained results showed that the studied structures satisfied the BSO of the seismic rehabilitation guidelines. Consequently, according to the results of analyses and the desired performance, this structural system, despite its high structural weight and rigid connections and low flexibility, has integrated performance, and it can be a good option for earthquake-resistant constructions.

Modified complex mode superposition design response spectrum method and parameters optimization for linear seismic base-isolation structures

  • Huang, Dong-Mei;Ren, Wei-Xin;Mao, Yun
    • Earthquakes and Structures
    • /
    • 제4권4호
    • /
    • pp.341-363
    • /
    • 2013
  • Earthquake response calculation, parametric analysis and seismic parameter optimization of base-isolated structures are some critical issues for seismic design of base-isolated structures. To calculate the earthquake responses for such non-symmetric and non-classical damping linear systems and to implement the earthquake resistant design codes, a modified complex mode superposition design response spectrum method is put forward. Furthermore, to do parameter optimization for base-isolation structures, a graphical approach is proposed by analyzing the relationship between the base shear ratio of a seismic base-isolation floor to non-seismic base-isolation one and frequency ratio-damping ratio, as well as the relationship between the seismic base-isolation floor displacement and frequency ratio-damping ratio. In addition, the influences of mode number and site classification on the seismic base-isolation structure and corresponding optimum parameters are investigated. It is demonstrated that the modified complex mode superposition design response spectrum method is more precise and more convenient to engineering applications for utilizing the damping reduction factors and the design response spectrum, and the proposed graphical approach for parameter optimization of seismic base-isolation structures is compendious and feasible.

Structural redundancy of 3D RC frames under seismic excitations

  • Massumi, Ali;Mohammadi, Ramin
    • Structural Engineering and Mechanics
    • /
    • 제59권1호
    • /
    • pp.15-36
    • /
    • 2016
  • The components of the seismic behavior factor of RC frames are expected to change as structural redundancy increases. Most researches indicate that increasing redundancy is desirable in response to stochastic events such as earthquake loading. The present paper investigated the effect of redundancy on a fixed plan for seismic behavior factor components and the nonlinear behavior of RC frames. The 3D RC moment resistant frames with equal lateral resistance were designed to examine the role of redundancy in earthquake-resistant design and to distinguish it from total overstrength capacity. The seismic behavior factor and dynamic behavior of structures under natural strong ground motions were numerically evaluated as the judging criteria for structural seismic behavior. The results indicate that increasing redundancy alone in a fixed plan cannot be defined as a criterion for improving the structural seismic behavior.

준정적실험에 의한 섬유보강된 철근콘크리트 교각의 내진성능 평가 (Quasi-Static Test for Seismic Performance of R/C Bridge Piers Retrofitted with Glassfibers)

  • 이대형;이재형;정영수;박진영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.871-876
    • /
    • 2001
  • Recent earthquakes in California and Japan caused extensive damage to highway bridge structures. It is also thought that during probable earthquakes bridge structures in Korea could be failed due to the structural deficiencies, which were nonseismically designed and constructed before 1992. In these regards, innovative strengthening methods have been developed to repair reinforced concrete bridge columns, especially by glassfiber sheet bonding methods which are widely used today. The primary objective of this research is to investigate the seismic behavior of RC bridge columns retrofitted with composite straps and to propose pertinent guidelines of repair and rehabilitation method for earthquake resistant design procedure of RC bridges which are located in low or moderate seismicity regions. Six scaled-down concrete test specimens were made with test variables such as lap splice ratio, axial force ratio, confinement ratio, composite straps in the plastic hinge region. Pertinent design guidelines could be developed for the earthquake resistant design of RC bridge piers retrofitted with glassfibers in low or moderate seismic region.

  • PDF

Response modification factor of dual moment-resistant frame with buckling restrained brace (BRB)

  • Abdollahzadeh, Gholamreza;Banihashemi, Mohammadreza
    • Steel and Composite Structures
    • /
    • 제14권6호
    • /
    • pp.621-636
    • /
    • 2013
  • Response modification factor is one of the seismic design parameters to consider nonlinear performance of building structures during strong earthquake, in conformity with the point that many seismic design codes led to reduce the loads. In the present paper it's tried to evaluate the response modification factors of dual moment resistant frame with buckling restrained braced (BRB). Since, the response modification factor depends on ductility and overstrength; the nonlinear static analysis, nonlinear dynamic analysis and linear dynamic analysis have been done on building models including multi-floors and different brace configurations (chevron V, invert V, diagonal and X bracing). The response modification factor for each of the BRBF dual systems has been determined separately, and the tentative value of 10.47 has been suggested for allowable stress design method. It is also included that the ductility, overstrength and response modification factors for all of the models were decreased when the height of the building was increased.

고층건물의 내진설계에 미치는 중력하중의 영향 (Implications of the effects of gravity load for earthquake resistant design of multistory building structurtes)

  • 이동근;이석용
    • 전산구조공학
    • /
    • 제6권3호
    • /
    • pp.67-80
    • /
    • 1993
  • 본 연구에서는 지진에 대한 고층건물의 응답특성, 그리고 지진응답에 미치는 중력하중의 영향과 중력하중의 영향이 내진설계에 미치는 중요성을 산정하였다. 이를 위해서 예제 구조물에 대한 정적해석 및 지진하중에 대한 동적해석을 하였다. 지진에 대한 고층건물의 지진응답 특성을 파악하기 위하여 비탄성 변형의 건물 높이에 따른 분포를 알아보았다. 지진이 발생하면 휨모멘트 요구도가 건물의 상부층보다 하부층에서 상대적으로 더 많이 증가해서 설계모멘트와의 차이가 건물의 하부층으로 갈수록 더 커진다. 그 결과 현재 쓰이는 내진설계방법에 따라 설계된 예제 건물들은 지진에 대하여 비탄성 응답이 건물의 각 층마다 서로 다르게 발생하는데 주로 건물의 하부층에서 큰 비탄성 응답이 발생한다. 또한 설계시에 고려된 중력하중 때문에 구조적 손상이 건물의 꼭대기 층에서 아래로 갈수록 크게 증가한다. 구조물의 지진응답에 관하여 중력하중은 보의 항복시간을 앞당기며, 보의 양단의 소성힌지에 각기 다른 비탄성 거동을 유발시킨다. 그러나 중력하중에 의한 초기 휨모멘트의 영향은 보가 비탄성 거동을 계속함에 따라 재분배되어 보의 양단에서 그 영향이 감소되며 비탄성 변형이 계속되면 크게 감소한다. 중력하중에 의한 초기 휨모멘트의 영향이 감소는 고층건물의 내진설계에 있어서 중력하중의 영향이 주는 의미는 기둥과 보의 휨강도를 결정할 때 현재의 방법보다 중력하중의 영향을 줄이고 지진하중의 영향을 증가시켜야 한다는 것이다.

  • PDF

Performance-Based Seismic Design of Reinforced Concrete Building Structures Using Inelastic Displacements Criteria

  • Kabeyaswa, Toshimi
    • 한국지진공학회논문집
    • /
    • 제2권3호
    • /
    • pp.61-71
    • /
    • 1998
  • A performance-based seismic design method for reinforced concrete building structures being developed in Japan is outlined. Technical and scientific background of the performance-based design philosophy as well as recently developed seismic design guidelines are is presented, in which maximum displacement response to design earthquake motion is used as the limit-state design criteria. A method of estimating dynamic response displacement of the structures based on static nonlinear analysis is described. A theoretical estimation of nonlinear dynamic response considering the characteristics of energy input to the system is described in detail, which may be used as the standard method in the new performance-based code. A desing philosophy not only satisfying the criteria but also evaluating seismic capacity of the structures is also introduced.

  • PDF

탄소판가새를 이용한 농촌 저층건물의 내진보강 (Seismic Reinforcement of Rural Low-rise Building using Carbon Fiver Plate)

  • 정동조;최성대
    • 한국농촌건축학회논문집
    • /
    • 제16권2호
    • /
    • pp.1-8
    • /
    • 2014
  • In the past, Korea was classified as a region not affected by earthquakes. However, recent increase of earthquakes has forced to strengthen standards of earthquake resistant designs of structures to minimize seismic damage. In addition, it was thought that masonry infill walls in buildings are only acting as partitions, so these walls are not considered in analyzing building structures. But it was found that when seismic loads are applied to a structure with masonry infill walls, the walls affect the structure. Accordingly, this study conducted nonlinear static analyses for a structure constructed before applying earthquake resistant designs in two cases: when considering masonry walls and when not. The result showed that the seismic performance of the structure is insufficient. Thus, the structural resistance of the structure was also studied in two cases: when reinforcing with steel plate braces and when using carbon fiber braces. In the two cases reinforcing two different stiffeners, it was appeared that the behaviors of the structure were similar, though the cross-section area of a carbon fiber brace used to reinforcing the structure is only 12.6% of a steel plate brace, and its weight is only 2.8%. Thus, the reinforcing effect of the thin, light-weighted carbon fiber brace is much larger than that of the steel plate brace, when considering usability and constructability of both materials.