• 제목/요약/키워드: seismic-resistant column

검색결과 51건 처리시간 0.017초

L형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 골조 구조물의 휨 거동 분석 (Analysis on the Flexural Behavior of Existing Reinforced Concrete Frame Structures Infilled with L-Type Precast Wall Panel)

  • 유승룡;주호성;손국원
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.52-62
    • /
    • 2015
  • This study aims at developing a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. Top shear connection of the PC panel was required to show the composite strength of RC column and PC wall panel. However, the strength of the connection did not influence directly on the ultimate loading capacities of the specimens in the positive loading because the loaded RC column push the side of PC wall panel and it moved horizontally before the shear connector receive the concentrated shear force in the positive loading process. Under the positive loading sequence(push loading), the reinforced concrete column and PC panel showed flexural strength which is larger than 97% of the composite section because of the rigid binding at the top of precast panel. Similar load-deformation relationship and ultimated horizontal load capacities were shown in the test of PR1-LA and PR1-LP specimens because they have same section dimension and detail at the flexural critical section. An average of 4.7 times increase in the positive maximum loading(average 967kN) and 2.7 times increase in the negative maximum loading(average 592.5kN) had resulted from the test of seismic resistant specimens with anchored and welded steel plate connections than that of unreinforced beam-column specimen. The maximum drift ratios were also shown between 1.0% and 1.4%.

Seismic behavior of steel column-base-connection equipped by NiTi shape memory alloy

  • Jamalpour, Reza;Nekooei, Masoud;Moghadam, Abdolreza Sarvghad
    • Structural Engineering and Mechanics
    • /
    • 제64권1호
    • /
    • pp.109-120
    • /
    • 2017
  • The behavior of moment resistant steel structures depends on both the beam-column connections and columns foundations connections. Obviously, if the connections can meet the adequate ductility and resistance against lateral loads, the seismic capacity of these structures will be linked practically to the performance of these connections. The shape memory alloys (SMAs) have been most recently used as a means of energy dissipation in buildings. The main approach adopted by researchers in the use of such alloys is firstly bracing, and secondly connecting the beams to columns. Additionally, the behavior of these alloys is modeled in software applications rarely involving equivalent torsional springs and column-foundation connections. This paper attempts to introduce the shape memory alloys and their applications in steel structural connections, proposing a new steel column-foundation connection, not merely a theoretical model but practically a realistic and applicable model in structures. Moreover, it entails the same functionality as macro modeling software based on real behavior, which can use different materials to establish a connection between the columns and foundations. In this paper, the suggested steel column-foundation connection was introduced. Moreover, exploring the seismic dynamic behavior under cyclic loading protocols and the famous earthquake records with different materials such as steel and interconnection equipment by superelastic shape memory alloys have been investigated. Then, the results were compared to demonstrate that such connections are ideal against the seismic behavior and energy dissipation.

Sensitivity analysis to determine seismic retrofitting column location in reinforced concrete buildings

  • Seo, Hyunsu;Park, Kyoungsub;Kwon, Minho;Kim, Jinsup
    • Structural Engineering and Mechanics
    • /
    • 제78권1호
    • /
    • pp.77-86
    • /
    • 2021
  • Local school buildings are critical facilities that can provide shelter in disasters such as earthquakes, so they must be more resistant to seismic forces than other structures. In this study, a sensitivity analysis was conducted to determine which columns-as the most critical members in a reinforced concrete building-most urgently require seismic retrofitting. The sensitivity analysis was conducted using an optimization technique with the location of each column as a parameter. A numerical model was developed to simulate a realistic collapse mode through a three-dimensional dynamic analysis. Based on numerical analysis results, it was found that the columns positioned in the lower floors, such as the first floor and in the outer part of a building, urgently require retrofitting. For reinforcement of the RC columns, which has been proven for its performance in previous research, was applied. Through this study, the importance of appropriate retrofitting is demonstrated. Further, a method for determining the appropriate location for retrofitting-when retrofitting is not possible on the entire structure-is presented.

Seismic-resistant slim-floor beam-to-column joints: experimental and numerical investigations

  • Don, Rafaela;Ciutina, Adrian;Vulcu, Cristian;Stratan, Aurel
    • Steel and Composite Structures
    • /
    • 제37권3호
    • /
    • pp.307-321
    • /
    • 2020
  • The slim-floor solution provides an efficient alternative to the classic slab-over-beam configuration due to architectural and structural benefits. Two deficiencies can be identified in the current state-of-art: (i) the technique is limited to nonseismic applications and (ii) the lack of information on moment-resisting slim-floor beam-to-column joints. In the seismic design of framed structures, continuous beam-to-column joints are required for plastic hinges to form at the ends of the beams. The present paper proposes a slim-floor technical solution capable of expanding the current application of slim-floor joints to seismic-resistant composite construction. The proposed solution relies on a moment-resisting connection with a thick end-plate and large-diameter bolts, which are used to fulfill the required strength and stiffness characteristics of continuous connections, while maintaining a reduced height of the configuration. Considering the proposed novel solution and the variety of parameters that could affect the behavior of the joint, experimental and numerical validations are compulsory. Consequently, the current paper presents the experimental and numerical investigation of two slim-floor beam-to-column joint assemblies. The results are discussed in terms of moment-rotation curves, available rotational capacity and failure modes. The study focuses on developing reliable slim-floor beam joints that are applicable to steel building frame structures located in seismic regions.

소성힌지부 강섬유 혼입 모르타르 적용 철근콘크리트 기둥의 내진성능평가 (Seismic Performance Evaluation of Reinforced Concrete Columns by Applying Steel Fiber-Reinforced Mortar at Plastic Hinge Region)

  • 조창근;한성진;권민호;임청권
    • 콘크리트학회논문집
    • /
    • 제24권3호
    • /
    • pp.241-248
    • /
    • 2012
  • 이 연구에서는, 철근콘크리트 기둥 실험체를 대상으로 기둥의 휨 위험 단면부에 국부적으로 강섬유 시멘트모르타르를 적용함으로서 기존 철근콘크리트 기둥에 비해 내진성능이 우수한 강섬유 모르타르 적용 철근콘크리트 복합기둥공법에 관해 제시하였다. 제시된 적용공법의 성능검증을 위하여 기존 철근콘크리트 기둥 1개 및 소성힌지구간에 국부적으로 강섬유 모르타르를 적용한 복합기둥 실험체 2개를 제작하여 일정 축하중 하에서 횡방향 반복하중을 받는 재하시험을 수행하였다. 콘크리트 및 강섬유 모르타르는 모두 현장타설되었다. 재하시험 결과 기존 철근콘크리트 기둥 실험체와 비교하여 강섬유 모르타르 적용 철근콘크리트 복합기둥 실험체의 경우 휨 및 전단 균열의 제어에 우수할 뿐만 아니라 기둥의 횡하중 내력 및 횡방향 변형 능력 향상에서도 우수한 것으로 평가되었다.

내부 보-기둥 접합부의 전단파괴 (Joint Shear Failure of Reinforced Concrete Interior Beam-Column Joint)

  • 이민섭;홍성걸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.303-308
    • /
    • 2000
  • The design of column joint is an important part of earthquake resistant design of reinforced concrete moment resisting frames. Beam column joints must provide sufficient stiffness and strength to resist and sustain the loads induced by adjacent beams and columns. This paper investigates the difference of the current design codes which provide a different approach for the design of beam column joint in seismic zone. The model provided by Hitoshi Shiohara(1998) is reviewed in this paper, which provides a good relationship between moment and shear action of interior beam column joint and a role shear reinforcement according to their position.

  • PDF

CFT와 합성보로 이루어진 CJS합성구조시스템의 내진성능 실험 연구 (Experimental Study of the Seismic Performance of CJS Hybrid Structural Systems Connected to the CFT Column)

  • 임창규;신지욱;문아해;김용남;이기학
    • 한국지진공학회논문집
    • /
    • 제26권2호
    • /
    • pp.83-93
    • /
    • 2022
  • In this study, to verify the structural performance of the Composite Joint System (CJS) hybrid structural model, a cyclic load test was performed and evaluated and verified through the test. To verify the structural performance of the CJS hybrid structural systems' joint and evaluate the seismic performance, four three-dimensional real-size specimens were developed with three internal beam-column specimens and one external beam-column specimen. The three interior column specimens were classified by different methods of joining the upper column and lower column, and the same bonding method as the primary specimen was used for the exterior column. The structural performances in terms of drift, strength, and energy dissipation capacity were analyzed and compared based on the experimental results. From the displacement-based loading experiment, all specimens showed a lateral drift of 4.0% without any significant strength drop and stable energy dissipation capacity.

Pseudo-dynamic and cyclic loading tests on a steel-concrete vertical hybrid structure

  • Wang, Bo;Wu, Tao;Dai, Huijuan;Bai, Guoliang;Wu, Jian
    • Earthquakes and Structures
    • /
    • 제17권4호
    • /
    • pp.399-409
    • /
    • 2019
  • This paper presents the experimental investigations on the seismic performance of a peculiar steel-concrete vertical hybrid structural system referred to as steel truss-RC tubular column hybrid structure. It is typically applied as the supporting structural system to house air-cooled condensers in thermal power plants (TPPs). Firstly, pseudo-dynamic tests (PDTs) are performed on a scaled substructure to investigate the seismic performance of this hybrid structure under different hazard levels. The deformation performance, deterioration behavior and energy dissipation characteristics are analyzed. Then, a cyclic loading test is conducted after the final loading case of PDTs to verify the ultimate seismic resistant capacity of this hybrid structure. Finally, the failure mechanism is discussed through mechanical analysis based on the test results. The research results indicate that the steel truss-RC tubular column hybrid structure is an anti-seismic structural system with single-fortification line. RC tubular columns are the main energy dissipated components. The truss-to-column connections are the structural weak parts. In general, it has good ductile performance to satisfy the seismic design requirements in high-intensity earthquake regions.

축력과 반복수평력을 받는 콘크리트 충전 내진 각형강관 기둥의 휨거동 특성 (Flexural Behavior of Concrete Filled Seismic Resistant Steel Tubular Columns Subjected to Axial and Cyclic Lateral Load)

  • 김병호;심현주;최병정;이은택
    • 한국강구조학회 논문집
    • /
    • 제23권3호
    • /
    • pp.317-326
    • /
    • 2011
  • 최근 CFT(Concrete Filled Steel Tube) 부재는 뛰어난 구조성능으로 인하여 그 사용범위가 확대되고 있다. 본 연구에서는 축력과 반복수평력을 받는 콘크리트 충전 내진 각형강관 기둥의 연성을 평가하는 실험을 수행하였다. 내진 각형강관은 SN400B 후판재를 냉간 프레스 성형하여 2개의 ㄷ자로 절곡한 후 기둥 폭의 중앙에서 2-seam 용접하는 방식으로 제작하였다. 강관의 폭두께비, 축력비, 가력방법을 변수로 총 8개의 실험체를 제작하여 실험을 수행하였고, 축하중과 반복수평력을 가력하기 위하여 2대의 액츄에이터가 사용되었다. 실험결과를 통해 기둥의 휨내력, 변형능력 및 에너지소산능력을 평가하였으며, 반복수평력에 대한 기둥의 연성거동 또한 평가되었다.

고강도 철근콘크리트 보-기둥 접합부의 내진성능 개선에 관한 실험적 연구 (Improvement of Earthquake-Resistant Performance of R/C Beam-Column Joint Constructed with High-Strength Concrete Subjected to Cyclic Loading)

  • 하기주;김진근;정란
    • 콘크리트학회지
    • /
    • 제4권1호
    • /
    • pp.135-145
    • /
    • 1992
  • 최근 철근콘크리트 건축물의 초고층화 추세에 따라 건축물의 설계시에 고강도의 건설재료, 부재단면의 축소, 직경이 큰 철근의 사용이 요구되고 있다. 이에 따라 구조물의 다른 부위에 비하여 접합부 영역의 응력 집중현상이 커지고, 철근콘크리트 구조물에 고강도 콘크리트를 적용하므로써 고정하중의 감소, 부재단면의 축소, 부재내력의 증대, 장 스팬 구조물의 축소 가능, 경제성의 향상을 가져올 수 있는 장점으로 인하여, 철근콘크리트 구조물에 고강도 콘크리트의 이용은 더욱 증대할 것으로 예상된다. 그러나 고강도콘크리트는 보통 콘크리트와 다른 특성, 특히 최대내력이후의 강도저하가 현저하고 파괴성상이 취성적인 성질을 지니고 있으므로 실제 구조물에 적용하기 앞서 구조물의 안전성 측면에서 부재 실험을 통하여 정확한 역학적 특성을 규명할 필요가 있다. 따라서 본 연구에서는 반복 주기하중을 받는 고강도 철근콘크리트 보-기둥 접합부의 거동을 파악하고, 접합부의 내진성능 개선을 위한 새로운 설계방법을 실제 초고층 철근콘크리트 건축물의 설계를 위한 기초 자료로 제시하였다.