• Title/Summary/Keyword: seismic-performance

Search Result 2,996, Processing Time 0.026 seconds

Experimental Study on the Active Control of a Three-story Building using $\textrm{H}_2$method ($\textrm{H}_2$제어 기법을 적용한 3층 건물의 능동제어 실험)

  • Joo, Soek-Jun;Min, Kyung-Won;Lee, Sung-Kyung;Kim, Sung-Chon;Hong, Sung-Mok
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.10a
    • /
    • pp.225-232
    • /
    • 1999
  • For the study of the seismic-response control, it is necessary to use an experimental system with an earthquake simulator and control devices employing a hydraulic actuator system. However, such system is too expensive to prepare at the university laboratory. In this research, an economical experimental system is developed which has a small-sized earthquake simulator and an AMD using AC servo motors. An accurate mathematical model of the three-degree-of-freedom tests structure with an AMD is developed from the measurement of the input/output relationships of the structure. This paper demonstrates experimentally the efficacy of the frequency domain optimal control algorithm H$_2$in reducing the response of seismically excited building to verify the performance of the experimental system.

  • PDF

Quasi-Static Tests for seismic performance of RC bridge piers (철근콘크리트 교각의 내진성능에 관한 준정적 실험)

  • 이강균;한기훈;정영수;이대형;황의승
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.615-620
    • /
    • 1998
  • The objective of this experimental study is to investigate the hysteretic behavior of reinforced concrete piers subjected to quasi-static cyclic loads, which have been used in large numbers for railway and urban transportation facilities. Important test parameters are hoop ratio, axial load, loading type, and the behaviors f members have been evaluated through limit states of crack occurrence, yielding and ultimate state of member, ductility and load-deflection loop can be secured by considering the influence of hoop reinforcement ratio and axial load, and that plastic hinge length and ductility ar determined by the combination of the quantities of hoop reinforcement and axial load.

  • PDF

Analytical Study on Splice Performances with the Vertical Noncontact Lapped of Reinforcing Bars (수직으로 비접촉 겹침이음된 철근의 이음성능에 관한 해석적 연구)

  • Lee Ho-Jin;Kim Seung-Hun;Ha Sang-Su;Moon Jeong-Ho;Lee Li-Hyung;Lee Yong-Taeg
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.171-174
    • /
    • 2005
  • In this study, new moment-resisting precast concrete beam-column joint is proposed for moderate seismic regions. It has the connection reinforcing bars, penetrated the joint and lap-spliced with the bottom bars of precast U-beam. To evaluate the performance for noncontact lapped splice, analytical works were conducted. Major variables for FEM analysis are the length of lap, the diameter of connection reinforcing bars, and the distance between lapped bars. The results of this study show thar the these variables has much influence on strength and deformation of lapped joint.

  • PDF

Preliminary Structural Design of Wall-Frame Systems for Optimum Torsional Response

  • Georgoussis, George K.
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.1
    • /
    • pp.45-58
    • /
    • 2017
  • Recent investigations have pointed out that current code provisions specifying that the stiffness of reinforced concrete elements is strength independent, and therefore can be estimated prior to any strength assignment, is incorrect. A strength allocation strategy, suitable for preliminary structural design of medium height wall-frame dual systems, is presented for allocating strength in such buildings and estimating the dependable rigidities. The design process may be implemented by either the approximate continuous approach or the stiffness matrix method. It is based on the concept of the inelastic equivalent single-degree-of-freedom system which, the last few years, has been used to implement the performance based seismic design. The aforesaid strategy may also be used to determine structural configurations of minimum rotation distortion. It is shown that when the location of the modal centre of rigidity, as described in author's recent papers, is within a close distance from the mass axis the torsional response is mitigated. The methodology is illustrated in ten story building configurations, whose torsional response is examined under the ground motion of Kobe 1995, component KJM000.

Calculation of Optimum Damping Ratio of Viscous Dampers Using Capacity Spectrum Method (능력스펙트럼법을 이용한 점성 감쇠기의 적정 감쇠비 산정)

  • 김진구;최현훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • 에너지 소산장치가 설치된 건무의 비선형 시간이력해석은 복잡하고 많은 시간이 소모된다. 본 연구에서는 비선형 정적해석법인 능력 스펙트럼을 이용하여 구조물의 주어긴 거동 한계를 만족할 수 있는 감쇠기의 양을 산정하는 방법에 관하여 연구하였다. 먼저 능력스펙트럼법을 이용하여 건물의 비선형 정적응답을 구하고 건물의 응답과 목표변위의 차이를 이용하여 유효감쇠비를 구하고 이러한 유효 감쇠비를 이용하여 필용한 점성 감쇠기의 양을 구하였다. 본 연구에서는 단자 유도계에서 건물의 주기, 요구되는 탄성강도에 대한 항복강도의 비, 항복 후 강성비 등을 변수로 하여 연구를 수행하였다. 제안된 방법에 따라 설계된 점성 감쇠기를 설치한 예제 구조물의 시간이력 해석에 의한 최대 응답은 설계의 초기단계에서 사용한 목표변위와 잘 일치하였다.

  • PDF

Mitigation of motions of tall buildings with specific examples of recent applications

  • Kareem, Ahsan;Kijewski, Tracy;Tamura, Yukio
    • Wind and Structures
    • /
    • v.2 no.3
    • /
    • pp.201-251
    • /
    • 1999
  • Flexible structures may experience excessive levels of vibration under the action of wind, adversely affecting serviceability and occupant comfort. To ensure the functional performance of a structure, various design modifications are possible, ranging from alternative structural systems to the utilization of passive and active control devices. This paper presents an overview of state-of-the-art measures that reduce the structural response of buildings, including a summary of recent work in aerodynamic tailoring and a discussion of auxiliary damping devices for mitigating the wind-induced motion of structures. In addition, some discussion of the application of such devices to improve structural resistance to seismic events is also presented, concluding with detailed examples of the application of auxiliary damping devices in Australia, Canada, China, Japan, and the United States.

Shaking table experiment on a steel storage tank with multiple friction pendulum bearings

  • Zhang, Ruifu;Weng, Dagen;Ge, Qingzi
    • Structural Engineering and Mechanics
    • /
    • v.52 no.5
    • /
    • pp.875-887
    • /
    • 2014
  • The aim of the shaking table experiment is to verify the isolation effect of a storage liquid tank with multiple friction pendulum bearings. A 1:20 scale model of a real storage liquid tank that is widely used in the petroleum industry was examined by the shaking table test to compare its anchored base and isolated base. The seismic response of the tank was assessed by employing the time history input. The base acceleration, wave height and tank wall stress were used to evaluate the isolation effect. Finally, the influences of the bearing performance that characterizes the isolated tank, such as the friction force and residual displacement, were discussed.

Response of self-centering braced frame to near-field pulse-like ground motions

  • Rahgozar, Navid;Moghadam, Abdolreza S.;Aziminejad, Armin
    • Structural Engineering and Mechanics
    • /
    • v.62 no.4
    • /
    • pp.497-506
    • /
    • 2017
  • A low damage self-centering braced frame equipped with post-tensioning strands is capable of directing damage to replaceable butterfly-shaped fuses. This paper investigates the seismic performance of rocking braced frame under near-field pulse-like ground motions compared to far-field records. A non-linear time history analysis is performed for twelve self-centering archetypes. A sensitivity analysis is carried out to examine the influences of ground motion types and modeling parameters. Findings represent the proper efficiency of the self-centering system under both far-field and near-field pulse-like ground motions.

Shear Strength Equation for Slender Diagonally Reinforced Coupling Beam (세장한 대각보강 연결보의 전단강도 예측식)

  • Han, Sang Whan;Kang, Jin Wook;Han, Chan Hee
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.361-368
    • /
    • 2016
  • Coupling beams serve as primary source of energy dissipation in coupled shear wall systems during large earthquakes. However, the overestimation of the shear strength of diagonally reinforced coupling beams may be adverse effect on the seismic performance of coupled shear wall systems. In order to force coupling beams to properly work during earthquakes, coupling beams should be designed with accurate shear strength equations. The objective of this study is to propose the accurate shear strength equation for slender diagonally reinforced coupling beams. For this purpose, experimental tests were conducted using three diagonally reinforced coupling specimens with different amount of transverse reinforcement under reversed cyclic loads to evaluate the hysteretic behavior of the specimens. The test results show that transverse reinforcement of slender diagonally reinforced coupling beam affects the maximum strength and drift ratio.

Control Strategy for Seismic Responses of Cable-Stayed Bridges Using MR Fluid Dampers (MR 유체 감쇠기률 이용한 사장교의 지진응답 제어 기법)

  • Jung, Hyung_-Jo;Moon, Yeong-Jong;Ko, Man-Gi;Lee, In-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.04a
    • /
    • pp.149-156
    • /
    • 2002
  • This paper examines the ASCE first generation benchmark problem for a seismically excited cable-stayed bridge, and proposes a new semi-active control strategy focusing on inclusion of effects of control- structure interaction. In this study, magnetorheological (MR) fluid dampers, which belong to the class of controllable fluid dampers, are proposed as the supplemental damping devices, and a clipped-optimal control algorithm, shown to perform well in previous studies involving MR fluid dampers, is employed. The dynamic model for MR fluid dampers is considered as a modified Bouc-Wen model, which is obtained from data based on experimental results for large-scale dampers. Numerical results show that the performance of the proposed semi-active control strategy using MR fluid dampers is quite effective.

  • PDF