• Title/Summary/Keyword: seismic-performance

Search Result 2,996, Processing Time 0.023 seconds

A Study in Seismic Signal Analysis for the First Arrival Picking (초동발췌를 위한 탄성파 신호분석연구)

  • Lee, Doo-Sung
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.2
    • /
    • pp.131-137
    • /
    • 2007
  • With consideration of the first arrival picking methodology and inherent errors in picking process, I propose, from the computerization point of view, a practical algorithm for picking and error computation. The proposed picking procedure consists of 2-step; 1) picking the first coherent peak or trough events, 2) derive a line which approximates the record in the interval prior to the pick, and set the intercept time of the line as the first break. The length of fitting interval used in experiment, is few samples less than 1/4 width of the arriving wavelet. A quantitative measure of the error involved in first arrival picking is defined as the time length that needed to determine if an event is the first arrival or not. The time length is expressed as a function of frequency bandwidth of the signal and the S/N ratio. For 3 sets of cross-well seismic data, first breaks are picked twice, by manually, and by the proposed method. And at the same time, the error bound for each trace is computed. Experiment results show that good performance of the proposed picking method, and the usefulness of the quantitative error measure in pick-quality evaluation.

Analytical Simulation of the Seismic Response of a High-Rise RC Building Model (고층 철근콘크리트 건축구조모델의 지진응답에 대한 해석적 모사)

  • Lee, Han-Seon;Lee, Jeong-Jae;Jung, Dong-Wook
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.5
    • /
    • pp.1-10
    • /
    • 2008
  • A series of shaking table tests were conducted on a 1:12 scale model using scaled Taft N21E earthquake records to investigate the seismic performance of a 17-story high-rise reinforced concrete building structure with a high degree of torsional eccentricity and soft-story irregularities in the bottom two stories. The main characteristics of the behaviors were: (1) a sudden change of the predominant vibration mode from the mode of translation and torsion to the torsional mode after the flexible side underwent a substantial inelastic deformation; (2) an abrupt increase in the torsional stiffness during this change of modes; (3) a warping behavior of the wall in the torsional mode; and (4) a unilateral overturning moment in the transverse direction to the table excitations. In this study, efforts were made to simulate the above characteristics using a nonlinear analysis program, Perform3D. The advantages and limitations are presented with the nonlinear models available in this software, as they are related to the correlation between analysis and test results.

Robustness Estimation for Power and Water Supply Network : in the Context of Failure Propagation (피해파급에 대한 고찰을 통한 전력 및 상수도 네트워크의 강건성 예측)

  • Lee, Seulbi;Park, Moonseo;Lee, Hyun-Soo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.3
    • /
    • pp.33-42
    • /
    • 2018
  • In the aftermath of an earthquake, seismic-damaged infrastructure systems loss estimation is the first step for the disaster response. However, lifeline systems' ability to supply service can be volatile by external factors such as disturbances of nearby facilities, and not by own physical issue. Thus, this research develops the bayesian model for probabilistic inference on common-cause and cascading failure of seismic-damaged lifeline systems. In addition, the authors present network robustness estimation metrics in the context of failure propagation. In order to quantify the functional loss and observe the effect of the mitigation plan, power and water supply system in Daegu-Gyeongbuk in South Korea is selected as case network. The simulation results show that reduction of cascading failure probability allows withstanding the external disruptions from a perspective of the robustness improvement. This research enhances the comprehensive understanding of how a single failure propagates to whole lifeline system performance and affected region after an earthquake.

Development of a Kit for Realtime transmission of data acquired by Earthquake accelerometers (지진가속도 계측기의 실시간 자료 전송 Kit 개발)

  • Heo, Jeongpil;Kim, Kiseog;Lim, Inseub;Jin, Jocheol
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.2
    • /
    • pp.254-262
    • /
    • 2014
  • KISStool is developed and established by KIGAM, in order to link and share the earthquake data easily with institutes related, this study includes the development of a KISStool program format and protocol supporting Kit. The Kit has functions such as transforming and sending a seismic data. The functions of the kit are implemented in modules, which are running on the realtime basis. The firmware is embedded into the Kit, which transforms the seismic data into the formats, miniSEED and QSCD20. These data are sent to KISStool program. We have confirmed the results of the data transforming, transmissions and storage functions are conducted normally, the speed of transmission shows same level when comparing with a standard system. We expect that the firmware developed in this study will have high usability not only for linking with KISStool program through being embedded into incompatible digitizers, but also for improving performance of older ones.

Nonlinear Analysis of RC Bridge Columns for Ductility Evaluation (철근콘크리트 교각의 연성도 평가를 위한 비선형해석)

  • 손혁수;이재훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.39-49
    • /
    • 2003
  • This research is a part of a research program to develope a new design method for reinforced concrete bridge columns under axial load and cyclic lateral load. A nonlinear analytical method is proposed to obtain moment-curvature relationship and lateral load-displacement relationship. Various analytical models that contribute seismic behavior of reinforced concrete bridge columns are adopted and modified by comparing quasi-static test results of reinforced concrete columns with spirals of circular hoops. The analysis adopts confined concrete model, longitudinal reinforcement test result of reinforced concrete columns with spirals or circular hoops. The analysis adopts confined concrete model, etc. The results obtained using the propose analytical method agree well with test results and give conservative estimations particularly for deformation capacity and ductility.

Estimation of the load-deformation responses of flanged reinforced concrete shear walls

  • Wang, Bin;Shi, Qing-Xuan;Cai, Wen-Zhe;Peng, YI-Gong
    • Structural Engineering and Mechanics
    • /
    • v.73 no.5
    • /
    • pp.529-542
    • /
    • 2020
  • As limited well-documented experimental data are available for assessing the attributes of different deformation components of flanged walls, few appropriate models have been established for predicting the inelastic responses of flanged walls, especially those of asymmetrical flanged walls. This study presents the experimental results for three large-scale T-shaped reinforced concrete walls and examines the variations in the flexural, shear, and sliding components of deformation with the total deformation over the entire loading process. Based on the observed deformation behavior, a simple model based on moment-curvature analysis is established to estimate flexural deformations, in which the changes in plastic hinge length are considered and the deformations due to strain penetration are modeled individually. Based on the similar gross shapes of the curvature and shear strain distributions over the wall height, a proportional relationship is established between shear displacement and flexural rotation. By integrating the deformations due to flexure, shear, and strain penetration, a new load-deformation analytical model is proposed for flexure-dominant flanged walls. The proposed model provides engineers with a simple, accurate modeling tool appropriate for routine design work that can be applied to flexural walls with arbitrary sections and is capable of determining displacements at any position over the wall height. By further simplifying the analytical model, a simple procedure for estimating the ultimate displacement capacity of flanged walls is proposed, which will be valuable for performance-based seismic designs and seismic capacity evaluations.

Seismic control response of structures using an ATMD with fuzzy logic controller and PSO method

  • Shariatmadar, Hashem;Razavi, Hessamoddin Meshkat
    • Structural Engineering and Mechanics
    • /
    • v.51 no.4
    • /
    • pp.547-564
    • /
    • 2014
  • This study focuses on the application of an active tuned mass damper (ATMD) for controlling the seismic response of an 11-story building. The control action is achieved by combination of a fuzzy logic controller (FLC) and Particle Swarm Optimization (PSO) method. FLC is used to handle the uncertain and nonlinear phenomena while PSO is used for optimization of FLC parameters. The FLC system optimized by PSO is called PSFLC. The optimization process of the FLC system has been performed for an 11-story building under the earthquake excitations recommended by International Association of Structural Control (IASC) committee. Minimization of the top floor displacement has been used as the optimization criteria. The results obtained by the PSFLC method are compared with those obtained from ATMD with GFLC system which is proposed by Pourzeynali et al. and non-optimum FLC system. Based on the parameters obtained from PSFLC system, a global controller as PSFLCG is introduced. Performance of the designed PSFLCG has been checked for different disturbances of far-field and near-field ground motions. It is found that the ATMD system, driven by FLC with the help of PSO significantly reduces the peak displacement of the example building. The results show that the PSFLCG decreases the peak displacement of the top floor by about 10%-30% more than that of the FLC system. To show the efficiency and superiority of the adopted optimization method (PSO), a comparison is also made between PSO and GA algorithms in terms of success rate and computational processing time. GA is used by Pourzeynali et al for optimization of the similar system.

Nonlinear Analytical Model of Unreinforced Masonry Wall using Fiber and Shear Spring Elements (파이버 및 전단 스프링요소를 이용한 비보강 조적벽체의 비선형 해석모델)

  • Hong, Jeong-Mo;Shin, Dong-Hyeon;Kim, Hyung-Joon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.6
    • /
    • pp.283-291
    • /
    • 2018
  • This study intends to develop an analytical model of unreinforced masonry(URM) walls for the nonlinear static analysis which has been generally used to evaluate the seismic performance of a building employing URM walls as seismic force-resisting members. The developed model consists of fiber elements used to capture the flexural behavior of an URM wall and a shear spring element implemented to predict its shear response. This paper first explains the configuration of the proposed model and describes how to determine the modeling parameters of fiber and shear spring elements based on the stress-strain curves obtained from existing experimental results of masonry prisms. The proposed model is then verified throughout the comparison of its nonlinear static analysis results with the experimental results of URM walls carried out by other researchers. The proposed model well captures the maximum strength, the initial stiffness, and their resulting load - displacement curves of the URM walls with reasonable resolution. Also, it is demonstrated that the analysis model is capable of predicting the failure modes of the URM walls.

Seismic Response Control Performance Evaluation of Retractable-Roof Spatial Structure With Variation of TMD Mass (TMD의 질량 변화에 따른 개폐식 대공간 구조물의 지진응답 제어성능 분석)

  • Lee, Young-Rak;Ro, Ho-Sung;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.1
    • /
    • pp.75-82
    • /
    • 2019
  • In the precedent study, the retractable-roof spatial structure was selected as the analytical model and a tuned mass damper (TMD) was installed to control the dynamic response for the earthquake loads. Also, it is analyzed that the installation location of TMD in the analytical model and the optimal number of installations. A single TMD mass installed in the analytical model was set up 1% of the mass of the whole structure, and the optimum installation location was derived according to the number of change. As a result, it was verified that most effective to install eight TMDs regardless of opening or closing. Thus, in this study, eight TMDs were installed in the retractable-roof spatial structure and the optimum mass ratio was inquired while reducing a single TMD. In addition, the optimum mass distribution ratio was identified by redistributing the TMD masses differently depending on the installation position, using the mass ratio of vibration control being the most effective for seismic load. From the analysis results, as it is possible to confirm the optimum mass distribution ratio according to the optimum mass ratio and installation location of the TMD in the the retractable-roof spatial structure, it can be used as a reference in the TMD design for large space structure.

Seismic behavior and failure modes of non-ductile three-story reinforced concrete structure: A numerical investigation

  • Hidayat, Banu A.;Hu, Hsuan-Teh;Hsiao, Fu-Pei;Han, Ay Lie;Sosa, Lisha;Chan, Li-Yin;Haryanto, Yanuar
    • Computers and Concrete
    • /
    • v.27 no.5
    • /
    • pp.457-472
    • /
    • 2021
  • Reinforced concrete (RC) buildings in Taiwan have suffered failure from strong earthquakes, which was magnified by the non-ductile detailing frames. Inadequate reinforcement as a consequence of the design philosophy prior to the introduction of current standards resulted in severe damage in the column and beam-column joint (BCJ). This study establishes a finite element analysis (FEA) of the non-ductile detailing RC column, BCJ, and three-story building that was previously tested through a tri-axial shaking table test. The results were then validated to laboratory specimens having the exact same dimensions and properties. FEA simulation integrates the concrete damage plasticity model and the elastic-perfectly plastic model for steel. The load-displacement responses of the column and BCJ specimens obtained from FEA were in a reasonable agreement with the experimental curves. The resulting initial stiffness and maximum base shear were found to be a close approximation to the experimental results. Also, the findings of a dynamic analysis of the three-story building showed that the time-history data of acceleration and displacement correlated well with the shaking table test results. This indicates the FEA implementation can be effectively used to predict the RC frame performance and failure mode under seismic loads.