• 제목/요약/키워드: seismic strength

검색결과 1,378건 처리시간 0.026초

ReliabIlity analysis of containment building subjected to earthquake load using response surface method

  • Lee, Seong Lo
    • Computers and Concrete
    • /
    • 제3권1호
    • /
    • pp.1-15
    • /
    • 2006
  • The seismic safety of reinforced concrete containment building can be evaluated by probabilistic analysis considering randomness of earthquake, which is more rational than deterministic analysis. In the safety assessment of earthquake-resistant structures by the deterministic theory, it is not easy to consider the effects of random variables but the reliability theory and random vibration theory are useful to assess the seismic safety with considering random effects. The reliability assessment of reinforced concrete containment building subjected to earthquake load includes the structural analysis considering random variables such as load, resistance and analysis method, the definition of limit states and the reliability analysis. The reliability analysis procedure requires much time and labor and also needs to get the high confidence in results. In this study, random vibration analysis of containment building is performed with random variables as earthquake load, concrete compressive strength, modal damping ratio. The seismic responses of critical elements of structure are approximated at the most probable failure point by the response surface method. The response surface method helps to figure out the quantitative characteristics of structural response variability. And the limit state is defined as the failure surface of concrete under multi-axial stress, finally the limit state probability of failure can be obtained simply by first-order second moment method. The reliability analysis for the multiaxial strength limit state and the uniaxial strength limit state is performed and the results are compared with each other. This study concludes that the multiaxial failure criterion is a likely limit state to predict concrete failure strength under combined state of stresses and the reliability analysis results are compatible with the fact that the maximum compressive strength of concrete under biaxial compression state increases.

건축구조물의 내진성능 향상을 위한 강재댐퍼 형상 및 이력 거동 (Metallic Damper Shape and Cyclic Behavior for the Seismic Capacity Improvement of Building Structures)

  • 이현호;김세일
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권3호
    • /
    • pp.123-130
    • /
    • 2010
  • 본 논문에서는 기존 건축물의 내진성능을 향상시키기 위해 시공성과 설치 비용적인 측면에서 상대적으로 우수한 강재댐퍼를 대상으로 기존 개발된 장치와 새로 개발된 형상의 장치에 대한 평가를 해석적으로 수행하였다. 해석결과는 강도 및 에너지 소산능력으로 평가하였으며, 제안된 내력 산정식의 적용을 아울러 평가하였다. 연구대상 댐퍼의 스트럿 형상은 V형, S형이며, 댐퍼의 스트럿 높이와 각도를 주요 변수로 한 후 ABAQUS를 이용하여 유한요소 해석하였다. 해석은 최대변위를 50mm로 하고 점진적인 이력변위곡선을 적용하여 수행하였다. 항복강도, 최대강도, 에너지 소산능력 평가결과, V형 및 S형 모두 우수한 성능을 보유한 것으로 평가되었으며, 또한 스트럿 각도 $60^{\circ}$ 및 높이 140, 200 mm의 성능이 안정적인 것으로 평가되었다. 전체적으로는 S형의 응답이 V형보다 안정적인 것으로 평가되어, S형 강재댐퍼의 적용성이 V형보다 유리한 것으로 평가되었다.

콘크리트 충전 강교각의 내진 성능 (The Seismic Performance for Concrete-filled Steel Piers)

  • 정지만;장승필;인성빈
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.189-196
    • /
    • 2002
  • The capacity of CFS piers has not been used to a practical design, because there is no guide of a seismic design for CFS piers. Therefore, the guide of a seismic design value is derived from tests of CFS piers in order to apply it to a practical seismic design. Steel piers and concrete-filled steel piers are tested with constant axial load using quasi-static cyclic lateral load to check ductile capacity and using the real Kobe ground motion of pseudo-dynamic test to verify seismic performance. The results prove that CFS piers have more satisfactory ductility and strength than steel piers and relatively large hysteretic damping in dynamic behaviors. The seismic performance of steel and CFS piers is quantified on the basis of the test results. These results are evaluated through comparison of both the response modification factor method by elastic response spectrum and the performance-based design method by capacity spectrum and demand spectrum using effective viscous damping. The response modification factor of CFS piers is presented to apply in seismic design on a basis of this evaluation for a seismic performance.

  • PDF

Vulnerability assessment and retrofit solutions of precast industrial structures

  • Belleri, Andrea;Torquati, Mauro;Riva, Paolo;Nascimbene, Roberto
    • Earthquakes and Structures
    • /
    • 제8권3호
    • /
    • pp.801-820
    • /
    • 2015
  • The seismic sequence which hit the Northern Italian territory in 2012 produced extensive damage to reinforced concrete (RC) precast buildings typically adopted as industrial facilities. The considered damaged buildings are constituted by one-storey precast structures with RC columns connected to the ground by means of isolated socket foundations. The roof structural layout is composed of pre-stressed RC beams supporting pre-stressed RC floor elements, both designed as simply supported beams. The observed damage pattern, already highlighted in previous earthquakes, is mainly related to insufficient connection strength and ductility or to the absence of mechanical devices, being the connections designed neglecting seismic loads or neglecting displacement and rotation compatibility between adjacent elements. Following the vulnerabilities emerged in past seismic events, the paper investigates the seismic performance of industrial facilities typical of the Italian territory. The European building code seismic assessment methodologies are presented and discussed, as well as the retrofit interventions required to achieve an appropriate level of seismic capacity. The assessment procedure and retrofit solutions are applied to a selected case study.

내진성능평가시 횡보강근이 없는 RC 보-기둥 접합부의 전단내력 평가 (Seismic Assessment of Shear Capacity of RC Beam-Column Joints Without Transverse Re-bars)

  • 이영욱
    • 한국지진공학회논문집
    • /
    • 제23권5호
    • /
    • pp.249-259
    • /
    • 2019
  • To study the seismic resistance of the shear capacity of the RC beam-column joints of two-story and four-story RC buildings, sample buildings are designed with ordinary moment resisting frame. For the shear capacity of joints, the equations of FEMA 356 and NZ seismic assessment are selected and compared. For comparison, one group of buildings is designed only for gravity loads and the other group is designed for seismic and gravity loads. For 16 cases of the designed buildings, seismic performance point is evaluated through push-over analysis and the capacity of joint shear strength is checked. Not only for the gravity designed buildings but also for seismic designed buildings, the demand of joint shear is exceeding the capacity at exterior joints. However, for interior joint, the demand of joint shear exceeds the capacity only for one case. At exterior joints, the axial load stress ratio is lower than 0.21 for gravity designed buildings and 0.13 for seismic designed buildings.

비보강 조적조 기준들의 강도식 비교 (The Comparison of Strength of pier in Different provisions)

  • 김홍범;이준석;한상환
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.312-319
    • /
    • 2001
  • The purpose of this study is to evaluate the strength of piers subjected to earthquake ground motion. In particular, the piers of an unreinforced masonry wall under in-plane seismic loading are considered with emphasis. For this purpose, several pier strength equations in seismic rehailitation provisions such as UCBC, FEMA 178, FEMA 273, and FEMA 306 are compared. This strength equations in different provision are applied for calculating the strength of a pier in building. According to the results of this study, it is shown that the assessment procedure based on FEMA 178 overestimated pier strengths comparing to other provisions when all piers are in Rocking-controlled mode.

  • PDF

정적실험을 통한 조적채움벽체가 비내진상세 RC 골조의 내진성능에 미치는 영향 평가 (An Experimental Study on the Influence of Masonry InFilled Walls on the Seismic Performance of Reinforced Concrete Frames with Non-seismic Details)

  • 김경민;천주현;백은림;오상훈;황철성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권3호
    • /
    • pp.114-120
    • /
    • 2017
  • 본 논문에서는 국내 비내진상세 조적채움벽 RC 골조의 내진성능을 파악하기 위하여 실규모 크기의 비내진상세 조적채움벽 RC 골조를 대상으로 정적실험을 실시하였으며, 기존 비내진상세 RC 골조 의 정적 실험결과와의 비교 분석을 통하여 조적채움벽체가 RC 골조의 내진성능에 미치는 영향에 대하여 평가하였다. 실험 결과. 조적채움벽 RC 골조 실험체는 조적채움벽체에 의한 압축력으로 기둥, 보, 접합부 등 골조 전체에 균열 등의 손상이 발생하였으며, 접합부 전단균열이 벌어지고 철근이 노출되면서 취성 파괴되었다. 한편, 조적체움벽 RC 골조 실험체의 수평하중과 층간변형각 관계는 벽체 슬라이딩 균열, 기둥 균열 등으로 강성이 저하되었으며, 철근 항복이후 최대 내력에 도달하고 접합부 균열의 확대, 철근 노출 등으로 내력이 최대 내력의 40% 정도로 저하되었다. 조적채움벽체로 인하여 기둥 상 하단 및 접합부에만 집중되던 손상이 기둥, 보, 접합부 등 골조 전체에 분산되어 발생하였으며, 기둥의 전단균열이 아닌 접합부의 전단균열의 확대로 최종 파괴되었다. 또한, 조적채움벽체로 인하여 RC 골조의 강성은 12.42배, 내력은 3.63배 증가한 반면에, 강성 증가에 따라 최대 내력 시의 층간변형각은 0.18배, 파괴시의 변형은 절반 이하로 감소하였다.

소규모 철근콘크리트 모멘트골조 건축물의 초과강도, 연성도 및 반응수정계수 (Over-Strength, Ductility and Response Modification Factor of Small-Size Reinforced Concrete Moment Frame Buildings)

  • 김태완;추유림;박홍근;신영수
    • 한국지진공학회논문집
    • /
    • 제20권3호
    • /
    • pp.145-153
    • /
    • 2016
  • Small-size buildings are not designed by professional structural engineers in Korea. Therefore, their seismic performance can not be exactly estimated because their member sizes and reinforcement may be over- or under-designed. A prescriptive design criteria for the small-size buildings exists, but it also provides over-designed structural members since structural analysis is not incorporated, so it is necessary to revise the prescriptive criteria. The goal of this study was to provide an information for the revision, which is seismic performance and capability of small-size reinforced concrete moment frame buildings. For the study, the state of existing small-size reinforce-concrete buildings such as member size and reinforcement was identified by investigating their structural drawings. Then, over-strength, ductility and response modification factor of the small-size reinforced concrete moment frame buildings were estimated by analytical approach along with seismic performance check. The result showed that they possess moderate over-strength and ductility, and may use slightly increased response modification factor.

Micro-concrete composites for strengthening of RC frame made of recycled aggregate concrete

  • Marthong, Comingstarful;Pyrbot, Risukka N.;Tron, Stevenly L.;Mawroh, Lam-I D.;Choudhury, Md. Sakil A.;Bharti, Ganesh S.
    • Computers and Concrete
    • /
    • 제22권5호
    • /
    • pp.461-468
    • /
    • 2018
  • In this paper, to access the suitability of recycled aggregate for structural applications, concrete strength i.e., compressive, tensile and flexural strength were evaluated and compared with those specimens made of natural aggregates. Test results indicated that 30 to 42% of the mentioned strength decreases. To study the performance of frame structures made of recycled aggregate concrete (RAC) two reinforced RAC frames were prepared and tested under monotonic loading. The joint regions of one of the RAC frame were casted with micro-concrete. A reference specimen was also prepared using natural aggregate concrete (NAC) and subjected to a similar loading condition. The RAC frame resulted in a brittle mode of failure as compared to NAC frame. However, the presence of a micro-concrete at the joint region of an RAC frame improved the damage tolerance and load resisting capacity. Seismic parameter such as energy dissipation, ductility and stiffness also improves. Conclusively, strengthening of joint region using micro-concrete is found to have a significant contribution in improving the seismic performance of an RAC frame.

RC기둥의 내진성능에 미치는 겹침 이음상세의 영향 (Effects of Lap Splice Details on Seismic Performance of RC Columns)

  • 김철구;박홍근;김태완;엄태성
    • 한국지진공학회논문집
    • /
    • 제20권6호
    • /
    • pp.351-360
    • /
    • 2016
  • In regions of low-to-moderate seismicity, various types of lap splices are used for longitudinal reinforcement of columns at the plastic hinge zones. The seismic performance of such lap spliced columns, such as strength, deformation capacity, and energy dissipation, is affected by material strengths, longitudinal re-bar size, confinement of hoops, lap splice location, and lap splice length. In the present study, cyclic loading tests were performed for columns using three types of lap splices (bottom offset bar splice, top offset bar splice, and splice without offset bend). Lap splice length($40d_b$ and $50d_b$) was also considered as test parameters. Ties with 90-degree end hooks were provided in the lap splice length. The test results showed that strength, deformation capacity, and energy dissipation of columns significantly differed depending on the details and the length of lap splices. The bottom offset bar splice showed high ductility and energy dissipation but low strength; on the other hand, the top offset bar splice and the splice without offset bend showed high strength but moderate ductility and energy dissipation.