• 제목/요약/키워드: seismic retrofit of concrete

검색결과 195건 처리시간 0.032초

Experimental assessment of post-earthquake retrofitted reinforced concrete frame partially infilled with fly-ash brick

  • Kumawat, Sanjay R.;Mondal, Goutam;Dash, Suresh R.
    • Earthquakes and Structures
    • /
    • 제22권2호
    • /
    • pp.121-135
    • /
    • 2022
  • Many public buildings such as schools, hospitals, etc., where partial infill walls are present in reinforced concrete (RC) structures, have undergone undesirable damage/failure attributed to captive column effect during a moderate to severe earthquake shaking. Often, the situation gets worsened when these RC frames are non-ductile in nature, thus reducing the deformable capability of the frame. Also, in many parts of the Indian subcontinent, it is mandatory to use fly-ash bricks for construction so as to reduce the burden on the disposal of fly-ash produced at thermal power plants. In some scenario, when the non-ductile RC frame, partially infilled by fly-ash bricks, suffers major structural damage, the challenge remains on how to retrofit and restore it. Thus, in this study, two full-scale one-bay, one-story non-ductile RC frame models, namely, bare frame and RC partially infilled frame with fly-ash bricks in 50% of its opening area are considered. In the previous experiments, these models were subjected to slow-cyclic displacement-controlled loading to replicate damage due to a moderate earthquake. Now, in this study these damaged frames were retrofitted and an experimental investigation was performed on the retrofitted specimens to examine the effectiveness of the proposed retrofitting scheme. A hybrid retrofitting technique combining epoxy injection grouting with an innovative and easy-to-implement steel jacketing technique was proposed. This proposed retrofitting method has ensured proper confinement of damaged concrete. The retrofitted models were subjected to the same slow cyclic displacement-controlled loading which was used to damage the frames. The experimental study concluded that the hybrid retrofitting technique was quite effective in enhancing and regaining various seismic performance parameters such as, lateral strength and lateral stiffness of partially fly-ash brick infilled RC frame. Thus, the steel jacketing retrofitting scheme along with the epoxy injection grouting can be relied on for possible repair of the structural members which are damaged due to the captive column effect during the seismic shaking.

노후 RC 건물의 내진 보강 (Seismic Retrofit of Old Reinforced Concrete Buildings)

  • 훠 찌안 촘;박종열;김진구
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2010년도 정기 학술대회
    • /
    • pp.150-153
    • /
    • 2010
  • 본 논문에서는 비내진 설계된 철근콘크리트 골조로 이루어진 저층의 노후공동주택의 내진성능을 향상시키기 위한 구조물의 보강방법에 대해 연구하였다. 이를 위하여 비선형 정적 해석과 시간 이력 해석을 수행하여 추가되는 철골 모멘트골조와 가새의 내진보강 효과를 검증하였다. 해석결과에 따르면 $H150{\times}150{\times}6{\times}8$로 구성된 철골 모멘트골조는 탄성구간에서는 하중의 약 1%, 구조물이 항복한 이후, 최대 3.5%까지 하중을 부담하여 자체적으로 지진하중에 대한 저항 성능은 크지 않았다. 그러나 철골 모멘트골조와 가새를 동시에 사용함으로써 접합부의 조기 파괴를 방지하고 구조물의 내진성능을 큰 폭으로 증진시킬 수 있는 것으로 나타났다.

  • PDF

A New Steel Jacketing Method for Concrete Cylinders and Comparison of the Results with a Constitutive Model

  • Choi, Eun-Soo;Kim, Man-Cheol
    • International Journal of Railway
    • /
    • 제1권2호
    • /
    • pp.72-81
    • /
    • 2008
  • This paper introduces a new steel jacketing method for reinforced concrete columns with lap splice and evaluates its performance by a series of axial tests of concrete cylinders. At first, 45 concrete cylinders were fabricated with varying the design compressive strengths of 21, 27 and 35 MPa and, then, the part of them was jacketed with two-split-steel jackets under lateral confining pressure. The parameters in the first test were the steel jacket's thickness and the existence of adhesive between steel and concrete surface. In the second test, whole steel jackets were used to wrap cylinders with lateral pressure. Also, a double-layer jacket consisted of two steel plates was introduced; a cylinder was jacketed by two steel plates one after another. The effect of the new method was verified through comparing the results of the compressive tests for plain and jacketed cylinders. The steel jacket built following the new method showed good results of increasing the compressive strength and ductility of the jacketed cylinders with respect to the plain cylinders. The thicker steel jackets showed the more increased compressive strength, and the ductility at failure depended on the welding quality on steel jackets. The adhesive between steel and concrete surface reduced the confining effect of the steel jackets. The whole jacket showed more ductile behavior than the two-split jackets. The double-layered jackets were estimated to possess an equal performance to that of a single steel jacket having the same thickness of the double-layered jacket. Finally, the experimental results were compared with the constitutive model of steel-jacketed concrete; which showed a good agreement between the experimental results and the models.

  • PDF

횡방향 구속응력에 의한 자켓팅-콘크리트 공시편 거동 (Behavior of concrete cylinders confined by jacketing with lateral confining stress)

  • 조성철;최은수;정영수;조백순;최지호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.157-160
    • /
    • 2008
  • 국내에는 내진설계가 적용되어지지 않고 설계 시공된 교량과 교각이 상당수 존재하며 지진 발생 시 취약한 소성흰지구간에서 충분한 횡구속 없이 주철근 겹침 이음을 가지고 있는 교각들이 다수 존재하고 있는 실정이다. 내진 성능향상을 위한 국내 많은 보강방법들이 연구되고 있는 추세이며 보다 효과적인 콘크리트 보강기법을 개발하기 위하여 횡방향 구속응력을 도입한 자켓팅 보강공법을 제시하였다. 자켓팅-콘크리트 공시편 압축 실험에서 강도 및 연성도에 영향을 주는 주요 요인 콘크리트은 압축강도, 보강량 및 보강재의 강도 등이다. 본 연구에서는 실시된 실험결과를 바탕으로 콘크리트 비선형 재료를 사용한 해석적 연구를 추가로 실시하여 실험에서 나타난 결과 값과 비교하고 실험 변수와 보강효과에 영향을 미치는 추가적인 변수를 추정하였다. 또한 선행 연구에서 제시된 횡방향구속응력을 사용한 자켓팅 보강공법의 적용성을 높이기 위한 방법들은 어떤 것들이 있는지에 대하여 서술 하였다.

  • PDF

Improvement of the cyclic response of RC columns with inadequate lap splices-Experimental and analytical investigation

  • Kalogeropoulos, George I.;Tsonos, Alexander-Dimitrios G.
    • Earthquakes and Structures
    • /
    • 제16권3호
    • /
    • pp.279-293
    • /
    • 2019
  • The overall seismic performance of existing pre 1960-70s reinforced concrete (RC) structures is significantly affected by the inadequate length of columns' lap-spliced reinforcement. Due to this crucial structural deficiency, the cyclic response is dominated by premature bond - slip failure, strength and stiffness degradation, poor energy dissipation capacity and low ductility. Recent earthquakes worldwide highlighted the importance of improving the load transfer mechanism between lap-spliced bars, while it was clearly demonstrated that the failure of lap splices may result in a devastating effect on structural integrity. Extensive experimental and analytical research was carried out herein, to evaluate the effectiveness and reliability of strengthening techniques applied to RC columns with lap-spliced reinforcement and also accurately predict the columns' response during an earthquake. Ten large scale cantilever column subassemblages, representative of columns found in existing pre 1970s RC structures, were constructed and strengthened by steel or RC jacketing. The enhanced specimens were imposed to earthquake-type loading and their lateral response was evaluated with respect to the hysteresis of two original and two control subassemblages. The main variables examined were the lap splice length, the steel jacket width and the amount of additional confinement offered by the jackets. Moreover, an analytical formulation proposed by Tsonos (2007a, 2019) was modified appropriately and applied to the lap splice region, to calculate shear stress developed in the concrete and predict if yielding of reinforcement is achieved. The accuracy of the analytical method was checked against experimental results from both the literature and the experimental work included herein.

강섬유보강 모르타르 바름에 의한 콘크리트 조적 프리즘의 압축 및 사인장 강도 증진 효과 (Enhancement of Compressive and Shear Strength for Concrete Masonry Prisms with Steel Fiber-Reinforced Mortar Overlay)

  • 유지훈;명성진;박지훈
    • 한국지진공학회논문집
    • /
    • 제25권1호
    • /
    • pp.21-32
    • /
    • 2021
  • Concrete masonry prisms are strengthened with steel fiber-reinforced mortar (SFRM) overlay and tested for compressive and diagonal tension strength. Masonry prisms are produced in poor condition considering standard workmanship for masonry buildings in Korea. Amorphous steel fibers are adopted for SFRM, and appropriate mixing ratios of SFRM are derived considering constructability and strength. Masonry prisms are strengthened with different fiber volume ratios, while numerous strengthened faces and additional reinforcing meshes are produced for compression and diagonal tension tests. Compression and diagonal tension strength are increased by up to 122% and 856%, respectively, and the enhancement effect for diagonal tension strength was superior compared to compression strength. Finally, the test results and strength prediction equations based on existing literature and regression analysis are compared.

L형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 골조 구조물의 전단 거동 분석 (Analysis on the Shear Behavior of Existing Reinforced Concrete Frame Structures Infilled with L-Type Precast Wall Panel)

  • 유승룡;주호성;하수경
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.105-117
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.

고인성섬유 복합모르타르를 활용한 고강도 철근콘크리트 외부 보-기둥 접합부의 내진성능평가 (Evaluation of Seismic Performance of High Strength Reinforced Concrete Exterior Beam-Column Joints Using High Ductile Fiber-Reinforced Mortar)

  • 하기주;신종학
    • 콘크리트학회논문집
    • /
    • 제25권4호
    • /
    • pp.419-428
    • /
    • 2013
  • 이 연구에서는 고강도 철근콘크리트 외부 보-기둥 접합부의 시공성 및 내진성능을 개선하기 위하여 보-기둥 접합부 영역의 스터럽 및 띠철근 유무에 따라 고인성섬유 복합모르타르를 사용하여 내진성능을 평가하였다. 총 5개의 실험체를 제작하고 실험을 수행하여 내진성능을 평가하였으며, 이 연구의 시험 결과를 근거로 다음과 같은 결론을 얻었다. 기존 고강도 철근콘크리트 내부 보-기둥 접합부의 위험단면 영역을 고인성섬유 복합모르타르로 보강한 결과 재하 전 과정을 통하여 섬유의 가교역할로 인한 균열 분산효과로 인하여 균열 제어 효과가 커서 안정적인 파괴형태 및 내력을 나타내었다. 고강도 철근콘크리트 외부 보-기둥 접합부의 시공성 및 내진성능을 개선하기 위하여 고인성섬유 복합모르타르를 사용하여 보강한 실험체(BCJNSP 시리즈)는 스터럽과 띠철근이 제거 되었음에도 안정적인 이력거동을 나타내었고, 최대내력이 전단보강근이 없는 실험체 BCJNS의 1.09~2.03배로 증가하였다. 그리고 고인성섬유 복합모르타르를 사용하여 보강한 실험체(BCJNSP 시리즈)는 표준실험체 BCJC의 최대내력이 0.92~0.96배로 거의 비슷하였고, 에너지소산능력은 최대 1.62배로 크게 증가하였다.

고인성섬유 복합모르타르를 활용한 고강도 철근콘크리트 내부 보-기둥 접합부의 내진성능 개선 연구 (A Study on Improvement of Seismic Performance of High Strength Reinforced Concrete Interior Beam-Column Joints using High Ductile Fiber-Reinforced Mortar)

  • 하기주;홍건호
    • 콘크리트학회논문집
    • /
    • 제24권6호
    • /
    • pp.753-760
    • /
    • 2012
  • 이 연구에서는 고강도 철근콘크리트 내부 보-기둥 접합부의 시공성 및 내진성능을 개선하기 위하여 보-기둥 접합부 영역의 스터럽 및 띠철근 유무에 따라 고인성섬유 복합모르타르를 사용하여 내진성능을 평가하였다. 총 6개의 실험체를 제작하고 실험을 수행하여 내진성능을 평가하였으며, 이 연구의 실험 결과를 근거로 다음과 같은 결론을 얻었다. 기존 고강도 철근콘크리트 내부 보-기둥 접합부의 위험단면 영역을 고인성섬유 복합모르타르로 보강한 결과 재하 전 과정을 통하여 섬유의 가교역할로 인한 균열 분산효과로 인하여 균열 제어 효과가 커서 안정적인 파괴형태 및 내력을 나타내었다. 고강도 철근콘크리트 내부 보-기둥 접합부의 시공성 및 내진성능을 개선하기 위하여 고인성섬유 복합모르타르를 사용하여 보강한 실험체($IJNSP_{1.0}$, $IJNSP_{1.5}$, $IJNSP_{2.0}$)는 스터럽과 띠철근이 제거되었음에도 안정적인 이력거동을 나타내었고, 최대내력이 표준실험체의 96~102.8%, 에너지소산능력은 최대 0.99~1.11배로 표준실험체와 거의 비슷한 에너지소산능력을 나타내었다.

U형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 보-기둥 구조물의 휨 거동 분석 (Analysis on the Flexural Behavior of Existing Reinforced Concrete Beam-Column Structures Infilled with U-Type Precast Wall Panel)

  • 손국원;유승룡;임철우;주호성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권5호
    • /
    • pp.56-66
    • /
    • 2015
  • 이 연구의 목표는 학교 건물과 같은 저층 보-기둥 철근콘크리트 구조 건물에서 프리캐스트 벽패널을 사용한 새로운 내진보강 방법을 개발하는 것이다. 1개의 무 보강 보-기둥 실험체와 U형 PC 벽패널로 보강한 2개의 보강 보-기둥 실험체에 대한 정적 이력 하중실험을 진행하였다. 앵커접합 PR1-UA 실험체와 철판접합 PR1-UP 실험체는 무 보강 실험체보다 평균 2.8배(평균 591.8 kN)의 강도 증가를 보여 주었다. 최대 변위비도 1.4%에서 2.7%사이 값을 보여주었다. RC 골조 우측 상단에서 좌측방향으로 가력 할 때 우측에 있는 RC 기둥과 보강 PC 패널의 수직 요소는 완전 합성상태로 가정하였고, 좌측에 있는 RC 기둥과 PC 패널은 완전 비 합성 거동하는 것으로 가정하여 해석한 결과 전체적인 휨 거동은 실험 결과와 대체적으로 부합하는 것으로 판단되었다.