• 제목/요약/키워드: seismic design code

검색결과 478건 처리시간 0.031초

횡방향철근 상세에 따른 원형기둥의 내진성능 (Seismic Performance of Circular Columns considering Transverse Steel Details)

  • 이재훈
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.259-266
    • /
    • 2000
  • This study was conducted to investigate the seismic behavior assessment of circular reinforcement concrete bridge piers particularly with regard to assessing the displacement ductility curvature ductility response modification factor(R) and plastic hinge region etc, The experimental variables of bridge piers test consisted of transverse steel details amount and spacing different axial load levels etc. The test results indicated that reinforcement concrete bridge piers with confinement steel by the code specification exhibited suffcient ductile behavior and seismic performance. Also it is found that current seismic design code specification of confinement steel requirements may be revised.

  • PDF

원형띠철근 기둥의 내진거동에 관한 실험적 연구 (The Experimental Study on Seismic Behavior of Circular-Tied Columns)

  • 석상근;고성현;윤석구;이재훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.369-374
    • /
    • 2000
  • This study was conducted to investigate the seismic behavior assessment of circlular-tied bridge piers, particularly with regard to assessing the displacement ductility. The experimental variables of bridge piers test consisted of transverse steel details, amount and spacing different axial load levels etc. The test results indicated that reinforcement concrete bridge piers with confinement steel by the code specification exhibited sufficient ductile behavior and seismic performance. Aldo, it is found that current seismic design code specification of confinement steel requirements may be revised.

  • PDF

Verification of diaphragm seismic design factors for precast concrete office buildings

  • Zhang, Dichuan;Fleischman, Robert B.;Lee, Deuckhang
    • Earthquakes and Structures
    • /
    • 제20권1호
    • /
    • pp.13-27
    • /
    • 2021
  • A new seismic design methodology has been developed for precast concrete diaphragms. Seismic design factors were used to be applied on top of diaphragm seismic design forces in the current code. These factors, established through extensive parametric studies, align diaphragm design strengths with different seismic performance targets. A simplified evaluation structure with a single-bay plan was used in the parametric studies. This simplified evaluation structure is reasonable and cost-effective as it can comprehensively cover structural geometries and design parameters. However, further verification and investigation are required to apply these design factors to prototype structures with realistic layouts. This paper presents diaphragm design of several precast concrete office buildings using the new design methodology. The applicability of the design factor to the office building was evaluated and verified through nonlinear time history analyses. The seismic behavior and performance of the diaphragm were investigated for the precast concrete office buildings. It was found that the design factor established for the new design methodology is applicable to the realistic precast concrete office buildings.

Development of the Damping Coefficients for Weak and Moderate Earthquake Ground Motions

  • Kim, Myeong-Han
    • 한국방재학회 논문집
    • /
    • 제8권5호
    • /
    • pp.1-6
    • /
    • 2008
  • 대부분의 내진설계기준에서는 설계지반운동을 정의하기 위해서 설계스펙트럼을 제시하고 있다. 기준에서 제시되는 설계스펙트럼은 일반적으로 5% 임계감쇠비에 대한 것이며, 이것은 일반적인 건축구조물에 적용할 수 있는 것이다. 에너지 소산장치나 면진 시스템의 적용이 점차 증가하고 있으며, 이러한 장치를 적용한 건축구조물의 내진해석을 위해서는 5% 임계감쇠비를 초과하는 설계스펙트럼이 필요하다. 5% 임계감쇠비에 대한 설계스펙트럼을 다른 임계감쇠비에 대한 설계스펙트럼으로 변환하기 위해서는 감쇠계수가 효과적으로 이용될 수 있다. 현재의 내진설계기준에서 제시하고 있는 감쇠계수는 강진자료를 바탕으로 제시된 것이다. 중진 및 약진은 강진과는 다른 특성을 가지므로, 이러한 감쇠계수가 중진 및 약진 지역에 적용하는 것은 충분한 검토가 필요할 것이다. 이 논문에서는 중진 및 약진자료를 이용한 감쇠계수를 제시하고, 현재 설계기준에서 제시하고 있는 감쇠계수와 비교하였다.

내진설계를 위한 지진 입력하중 조정 방법 (Method of the Calibration of earthquake Ground Motions for Seismic Design)

  • 공도환
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.20-27
    • /
    • 1998
  • In the current seismic design codes design earthquake is usually defined as the earthquake with the 90 percent probability of not being exceeded in the life time of a structure which is assumed as 50 years equivalent to the earthquake with 475 year recurrence period. However the life time of tall building structures may be much longer than 50 yers. The current seismic design code requires the modal analysis or dynamic time history analysis for the buildings with the height exceeding a certain height limit. The objective of this study is to collect the earthquake ground motion(EQGM) which can be used for dynamic time history analysis for tall buildings. For this purpose linear elastic design response spectrum (LEDRS) in the code is scaled to account for the recurrence period of the design earthquake. The earthquake ground motions which has been recorded are calibrated to fit the scaled LEDRS. The set of calibrated EQGM can be treated as design EQGM for the design of tall building with longer lifetime than ordinary building.

  • PDF

유사동적 실험에 의한 철근콘크리트 교각의 주철근 겹이음에 따른 한정연성능력 (Limited Ductile Capacity of Reinforced Concrete Bridge Pier with Longitudinal Steel Lap-splicing by Pseudo Dynamic Test)

  • 박창규;박진영;조대연;이대형;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.885-890
    • /
    • 2002
  • Pseudo dynamic test is an on-line computer control method to achieve the realism of shaking table test with the economy and versatility of the conventional quasi-static approach. Pseudo dynamic tests of four full-size RC bridge piers have been carried out to investigate their seismic performance. For the purpose of precise evaluation, the experimental investigation was conducted to study the seismic performance of the real size specimen, which is constructed for highway bridge piers in Korean peninsula. Since it is believed that Korea belongs to the moderate seismicity region, three test specimens were designed in accordance with limited ductility design concept. Another one test specimen was nonseismically designed according to a conventional code. Important test parameters were transverse reinforcement and lap splicing. Lap splicing was frequently used in the plastic hinge region of many bridge columns. Furthermore, the seismic design code is not present about lap splice in Korean Roadway Bridge Design Code. The results show that specimens designed according to the limited ductility design concept exhibit higher seismic resistance. Specimens with longitudinal steel lap splice in the plastic hinge region appeared to significantly fail at low ductility level.

  • PDF

동적 해석법을 이용한 내진설계 결과의 비교 고찰 (Comparative Study on the Results of Seismic Design by Dynamic Analysis Method)

  • 이성우;노홍식;심규점
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1991년도 가을 학술발표회 논문집
    • /
    • pp.81-89
    • /
    • 1991
  • Recently increasing number of highrise buildings are aseismically designed by dynamic analysis method. To perform comparative study on the results of seismic design by dynamic analysis method, five-to thirty-story building models of ductile moment resisting frames and braced frames are considered. Base shears of these models using the spectrum of equivalent static method in the current Korean code and the ones of dynamic analysis method in the UBC-88 code are compared. Based on this study design spectra to be used in the dynamic analysis in Korea are proposed and the results are compared.

  • PDF

New approach in design of seismic isolated buildings applying clusters of rubber bearings in isolation systems

  • Melkumyan, Mikayel G.
    • Earthquakes and Structures
    • /
    • 제4권6호
    • /
    • pp.587-606
    • /
    • 2013
  • The given paper presents a new approach in design of seismic isolation systems of base isolated buildings. The idea is to install not one big size rubber bearing under the columns and/or shear walls, or one by one with certain spacing under the load-bearing walls, but to install a group/cluster of small size bearings, in order to increase the overall effectiveness of the isolation system. The advantages of this approach are listed and illustrated by the examples. Also the results of analyses of some buildings where the approach on installation of clusters of rubber bearings was used in their isolation systems are given for two cases: i) when the analyses are carried out based on the provisions of the Armenian Seismic Code, and ii) when the time history analyses are carried out. Obtained results are compared and discussed. Paper also presents, as an example, detailed analysis and design of the 18-story unique building in one of the residential complexes in Yerevan. Earthquake response analyses of this building were carried out in two versions, i.e. when the building is base isolated and when it is fixed base. Several time histories were used in the analyses. Comparison of the obtained results indicates the high effectiveness of the proposed structural concepts of isolation systems and the need for further improvement of the Seismic Code provisions regarding the values of the reduction factors. A separate section in the paper dedicated to the design of high damping laminated rubber-steel bearings and to results of their tests.

Seismic performance of concrete moment resisting frame buildings in Canada

  • Kafrawy, Omar El;Bagchi, Ashutosh;Humar, Jag
    • Structural Engineering and Mechanics
    • /
    • 제37권2호
    • /
    • pp.233-251
    • /
    • 2011
  • The seismic provisions of the current edition (2005) of the National Building Code of Canada (NBCC) differ significantly from the earlier edition. The current seismic provisions are based on the uniform hazard spectra corresponding to 2% probability of exceedance in 50 years, as opposed to the seismic hazard level with 10% probablity of exeedance in 50 years used in the earlier edition. Moreover, the current code is presented in an objective-based format where the design is performed based on an acceptable solution. In the light of these changes, an assessment of the expected performance of the buildings designed according to the requirements of the current edition of NBCC would be very useful. In this paper, the seismic performance of a set of six, twelve, and eighteen story buildings of regular geometry and with concrete moment resisting frames, designed for Vancouver western Canada, has been evaluated. Although the effects of non-structural elements are not considered in the design, the non-structural elements connected to the lateral load resisting systems affect the seismic performance of a building. To simulate the non-structural elements, infill panels are included in some frame models. Spectrum compatible artificial ground motion records and scaled actual accelerograms have been used for evaluating the dynamic response. The performance has been evaluated for each building under various levels of seismic hazard with different probabilities of exceedance. From the study it has been observed that, although all the buildings achieved the life-safety performance as assumed in the design provisions of the building code, their performance characteristics are found to be non-uniform.

Overview of Performance-Based Seismic Design of Building Structures in China

  • Li, Guo-Qiang;Xu, Yan-Bin;Sun, Fei-Fei
    • 국제초고층학회논문집
    • /
    • 제1권3호
    • /
    • pp.169-179
    • /
    • 2012
  • The development history, the current situation and the future of the performance-based seismic design of building structures in China are presented in this paper. Firstly, the evolution of performance-based seismic design of building structures specified in the Chinese codes for seismic design of buildings of the edition 1974, 1978, 1989, 2001 and 2010 are introduced and compared. Secondly, in two parts, this paper details the provisions of performance-based seismic design in different Chinese codes. The first part is about the "Code for Seismic Design of Buildings" (GB50011) (edition 1989, 2001 and 2010) and "Technical Specification for Concrete Structures of Tall Building", which presents the concepts and methods of performance-based seismic design adopted in Chinese codes; The second part is about "Management Provisions for Seismic Design of Outof-codes High-rise Building Structures" and "Guidelines for Seismic Design of Out-of-codes High-rise Building Structures", which concludes the performance-based seismic design requirements for high-rise building structures over the relevant codes in China. Finally, according to those mentioned above, this paper pointed out the imperfections of current performance-based seismic design in China and proposed the possible direction for further improvement.