• 제목/요약/키워드: seismic design

검색결과 3,061건 처리시간 0.028초

지하층이 있는 구조물의 지진응답을 위한 원심모형실험 (Centrifuge Test for Earthquake Response of Structures with Basements)

  • 김동관;박홍근;김동수;하정곤
    • 한국지진공학회논문집
    • /
    • 제20권4호
    • /
    • pp.223-234
    • /
    • 2016
  • To investigate earthquake responses of structures with basements affected by soil deposits, centrifuge tests were performed using an in-flight earthquake simulator. The test specimen was composed of a single-degree-of-freedom structure model, a basement and sub-soil deposits in a centrifuge container. The test parameters were the dynamic period of the structure model, boundary conditions of the basement, existence of soil deposits, centrifugal acceleration level, and type and level of input earthquake accelerations. When soil deposits did not exist, the earthquake responses of the structures with fixed basement were significantly greater than those of the structure without basement. Also, the earthquake responses of the structures with the fixed basement surrounded by soil deposits were amplified, but the amplifications were smaller than those of the structures without basement. The earthquake responses of the structures with the half-embedded basement in the soil deposits were greater than those estimated by the fixed base model using the measured free-field ground motion. The test showed that the basement and the soil deposit should be simultaneously considered in the numerical analysis model, and the stiffness of the half-embedded was not effective.

실지진 모사를 위한 조합형 정현하중의 적용성 검증 (Verification of Combined Sinusoidal Loads for Simulating Real Earthquakes)

  • 최재순
    • 대한토목학회논문집
    • /
    • 제39권6호
    • /
    • pp.811-819
    • /
    • 2019
  • 2016년 경주지진과 2017년 포항지진이 발생한 이후, 우리나라 내진설계에 있어서 다양한 실내진동시험의 수행이 증가하고 있으나, 액상화 평가나 수치해석의 입력파라미터를 산정하기 위한 실내진동시험에서는 이전부터 사용해 오던 정현하중의 이용이 계속되고 있다. 그러나, 최근 정현하중으로는 지진하중으로 야기되는 지반 내 과잉간극수압의 거동을 정확하게 모사하기 어렵다는 연구결과가 발표되며 정현하중을 대신하여 동하중의 개발에 대한 논의가 주목을 받기 시작하였다. 이 연구에서는 이러한 문제를 해결하고자 조합형 정현하중을 제안하고 주문진 표준사를 대상으로 한 진동전단실험과 진동삼축압축시험을 통해 그 적용성을 검토하였으며 추가로 진동대시험과 유효응력해석모델에 기초한 수치해석을 통해 그 타당성을 검토하였다. 검토 결과, 제안된 조합형 정현하중이 정현하중보다 실지진하중 하에서의 포화지반 내 과잉간극수압의 거동변화를 잘 모사할 수 있음을 발견하였다.

한반도 지진에 대한 원인 및 대처방안 (Cause and Countermeasures on the Korean Peninsula Earthquake)

  • 양원직;허대욱
    • 한국방재안전학회논문집
    • /
    • 제9권2호
    • /
    • pp.9-13
    • /
    • 2016
  • 지진안전지대라고 불려왔던 한반도에 최근 지진이 자주 발생하여 전례없는 인적 물적 피해가 발생하였다. 이는 3층 미만의 건축물에 대해서는 내진설계가 되어있지 않고, 일부 전문가 및 단체를 제외하고는 지진에 대한 심각성 및 대피요령에 대해서 숙지하지 못하고 있어 피해가 가중된 것으로 사료된다. 이상과 같이 국민 대부분이 대피요령이나 생존법, 비상물자 등을 인지하지 못하고, 각종 필요한 지진대비 교육이 없는 실정이다. 따라서 지진에 대해서 준비가 전무했던 우리가 이제 지진에 대해 정확한 실체와 원인을 알아보고 준비와 대책을 세워야 할 시점이라 사료된다. 본 연구에서는 빈번하게 발생하는 한반도 지진에 대하여 원인에 대해서 조사하고 우리정부와 지자체, 민간단체, 언론 및 개인의 대처방안에 대해서 체계적으로 정리하고자 한다.

Hysteretic behaviour of circular tubular T-joints with local chord reinforcement

  • Shao, Y.B.;Wang, Y.M.;Yang, D.P.
    • Steel and Composite Structures
    • /
    • 제21권5호
    • /
    • pp.1017-1029
    • /
    • 2016
  • When a welded circular hollow section (CHS) tubular joint is subjected to brace axial loading, failure position is located usually at the weld toe on the chord surface due to the weak flexural stiffness of the thin-walled chord. The failure mode is local yielding or buckling in most cases for a tubular joint subjected to axial load at the brace end. Especially when a cyclic axial load is applied, fracture failure at the weld toe may occur because both high stress concentration and welding residual stress along the brace/chord intersection cause the material in this region to become brittle. To improve the ductility as well as to increase the static strength, a tubular joint can be reinforced by increasing the chord thickness locally near the brace/chord intersection. Both experimental investigation and finite element analysis have been carried out to study the hysteretic behaviour of the reinforced tubular joint. In the experimental study, the hysteretic performance of two full-scale circular tubular T-joints subjected to cyclic load in the axial direction of the brace was investigated. The two specimens include a reinforced specimen by increasing the wall thickness of the chord locally at the brace/chord intersection and a corresponding un-reinforced specimen. The hysteretic loops are obtained from the measured load-displacement curves. Based on the hysteretic curves, it is found that the reinforced specimen is more ductile than the un-reinforced one because no fracture failure is observed after experiencing similar loading cycles. The area enclosed by the hysteretic curves of the reinforced specimen is much bigger, which shows that more energy can be dissipated by the reinforced specimen to indicate the advantage of the reinforcing method in resisting seismic action. Additionally, finite element analysis is carried out to study the effect of the thickness and the length of the reinforced chord segment on the hysteretic behaviour of CHS tubular T-joints. The optimized reinforcing method is recommended for design purposes.

Observational failure analysis of precast buildings after the 2012 Emilia earthquakes

  • Minghini, Fabio;Ongaretto, Elena;Ligabue, Veronica;Savoia, Marco;Tullini, Nerio
    • Earthquakes and Structures
    • /
    • 제11권2호
    • /
    • pp.327-346
    • /
    • 2016
  • The 2012 Emilia (Italy) earthquakes struck a highly industrialized area including several thousands of industrial prefabricated buildings. Due to the lack of specific design and detailing for earthquake resistance, precast reinforced concrete (RC) buildings suffered from severe damages and even partial or total collapses in many cases. The present study reports a data inventory of damages from field survey on prefabricated buildings. The damage database concerns more than 1400 buildings (about 30% of the total precast building stock in the struck region). Making use of the available shakemaps of the two mainshocks, damage distributions were related with distance from the nearest epicentre and corresponding Pseudo-Spectral Acceleration for a period of 1 second (PSA at 1 s) or Peak Ground Acceleration (PGA). It was found that about 90% of the severely damaged to collapsed buildings included into the database stay within 16 km from the epicentre and experienced a PSA larger than 0.12 g. Moreover, 90% of slightly to moderately damaged buildings are located at less than 25 km from the epicentre and were affected by a PSA larger than 0.06 g. Nevertheless, the undamaged buildings examined are almost uniformly distributed over the struck region and 10% of them suffered a PSA not lower than 0.19g. The damage distributions in terms of the maximum experienced PGA show a sudden increase for $PGA{\geq}0.28g$. In this PGA interval, 442 buildings were collected in the database; 55% of them suffered severe damages up to collapse, 32% reported slight to moderate damages, whereas the remaining 13% resulted undamaged.

축하중과 이축모멘트를 받는 철근콘크리트 기둥의 모멘트-곡률에 관한 모델링 및 변수고찰 (Modeling and Parametric Studies on Moment-Curvature Relation of a Reinforced Concrete Column Subject In Axial-toad and Bi-Axil Moment)

  • 이차돈;최기봉;차준실;김성진
    • 콘크리트학회논문집
    • /
    • 제14권5호
    • /
    • pp.677-688
    • /
    • 2002
  • 철근콘크리트 기둥의 비선형 이축모멘트-곡률 관계를 추적할 수 있는 이론모델을 개발하였다. 개발된 모델은 피복콘크리트 박리나 또는 최대하중 후 나타날 수 있는 기둥의 모멘트 저항능력의 취성적인 감소도 모사할 수 있다. 개발된 모델을 이용 기둥의 구성재료 특성과 철근의 기하학적 배치가 PM 상관도와 모멘트-곡률에 미치는 영향에 대하여 변수영향을 고찰하고 철근콘크리트 기둥의 연성은 축하중의 크기, 횡방향 철근의 간격 또는 체적에 가장 큰 영향을 받음이 이론적으로 고찰된 ACI PM-상관도와 비교하여 ACI 내진설계 기준에 따라 횡방향 철근이 배근된 기둥의 경우, 축하중과 모멘트에 대한 : (square root of sum of squares)값이 약 10% 증가하였으며 최대 축하중은 약 20% 정도 증가하였다.

탄질 셰일 파쇄구간에서 터널 붕락부 거동 및 보강 연구 (Auxiliary Reinforcement Method for Collapse of Tunnel in the Coal Shale Fractured Zone)

  • 김낙영;문창열;박용석
    • 한국지반환경공학회 논문집
    • /
    • 제8권6호
    • /
    • pp.85-95
    • /
    • 2007
  • 탄질 셰일 파쇄대의 경우, 물리탐사의 사전조사방법으로 그 여부를 파악하기 어렵고 또한, 용수등에 노출이 안되는 경우 탄질 셰일층 강도 자체는 양호한 특성이 있다. 그러나 이러한 탄질 셰일층의 경우 용수에 접하거나 대기에 노출되는 경우 단기간내에 강도가 급격히 저하되거나 풍화가 급속히 진전되는 매우 취약한 특성이 있다. 따라서 사전 예측하기가 어렵고 붕락발생시 급작스럽게 발생하는 경우가 대부분이다. 강도감소 측면에서는 용수와 접할시, 탄층 세일 파쇄대층에 대한 점하중 강도 시험결과 12시간 경과후 강도가 56%감소하였다. 또한 본 논문에서는 탄질 셰일 파쇄구간에 대한 표준 보강단면을 제시하였다.

  • PDF

실지진하중을 이용한 포화사질토의 액상화 저항강도에 관한 실험적 연구 (An Experimental Study for the Liquefaction Resistance Strength of Saturated Sand Using Real Earthquake Loading)

  • 심재욱;박근보;최재순;김수일
    • 한국지반공학회논문집
    • /
    • 제18권4호
    • /
    • pp.329-337
    • /
    • 2002
  • 최근까지 지반의 액상화 저항강도를 산정하기 위한 실내시험의 대부분은 실지진하중을 재하하기보다는 Seed와 Idriss(1975)가 제안한 등가전단응력 개념에 기초하여 지진이 발생시키는 최대전단응력의 65%를 최대진폭으로 한 정현하중을 반복재하시켜왔다. 이러한 정현하중이 정확하게 실제 지반에 작용하는 불규칙한 지진력을 모사하고 있다고 볼 수 없으나, 시험상의 편의성으로 인해 현재까지도 이용이 빈번한 실정이다. 본 연구에서는 실제 지진하중 하에서 포화 사질토의 거동변화를 규명하고자 정현하중이 아닌 불규칙한 지진하중을 이용한 실험적 연구를 수행하였다. 다양한 지진규모의 실지진 시간이력을 진동하중으로 작용시킨 진동삼축시험을 통해 지진규모 및 지속시간의 변화에 따른 포화사질토의 동적 특성을 실험적으로 규명하고 기존의 등가전단응력 개념에 기초한 액상화 저항강도와 비교분석하였다. 또한, 중약진 지진대로 구분되는 국내 실정을 고려하여 다양한 지진규모에 적용가능한 수정계수를 제시하고 이를 기존의 연구결과와 비교분석하였다.

강합성 플레이트거더교의 가로보 배치에 관한 연구 (A Study on the Disposition of Cross Beams in Composite Plate Girder Bridge)

  • 박용명;백승용;황민오
    • 한국강구조학회 논문집
    • /
    • 제14권6호
    • /
    • pp.691-699
    • /
    • 2002
  • 본 논문에서는 수직 및 수평 브레이싱을 생략하고 I-형 거더를 가로보만으로 연결한 다주형 강합성 플레이트거더교 형식에서 가로보의 적정 배치 간격 및 소요 휨강성의 산정을 위한 연구를 수행하였다. 이를 위해 지간 40m의 단순교와 40+50+40m의 2차로 4주형 연속교를 예제교량으로 시산 설계하였다. 본 교량에 대해 중간가로보의 배치 간격과 휨강성를 매개변수로 하여 합성전 후 고정하중, 활하중 및 지진하중을 포함하는 설계하중에 대한 응력 해석을 수행한 후 강재 주형 및 라로보의 격자구조에 대해 합성전 고정하중을 고려한 재료-기하비선형해석으로부터 횡비틀림 좌굴강도를 평가하였다. 이상의 두 가지 국면 해석 결과를 토대로 단부 및 중간가로보의 적정 배치 간격과 소요 휨강성을 제안하였다.

대기환경하에서 장기간 사용된 부식강재의 실험적 피로거동평가 (Experimentally Evaluating Fatigue Behavior of Corroded Steels Exposed in Atmospheric Environments)

  • 문재민;정영수;전제형;안진희;김인태
    • 한국강구조학회 논문집
    • /
    • 제29권3호
    • /
    • pp.193-204
    • /
    • 2017
  • 실제 옥외 대기환경하에서 부식손상된 무도장 가시설 강재 및 도장 강재의 피로강도는 명확하지 않다. 본 연구에서는 약 7년간 지하철 공사현장에서 사용된 가시설 부재와 극심한 해양 부식환경하에서 75년간 사용된 영도대교 강부재로부터 절취한 강재의 피로실험을 실시하였다. 그리고 강재 표면의 부식 생성물을 제거한 후 강재 표면의 3차원형상을 측정하여 최대, 최소 및 평균 잔존두께를 계산하였다. 피로실험결과 및 FEM해석 결과에 근거하여 부식특성과 피로강도와의 상관관계를 검토하였으며, 실제 옥외 환경하에서 부식된 무도장 및 도장 강재의 피로수명 평가식도 제시하였다.