• 제목/요약/키워드: seismic code

검색결과 674건 처리시간 0.03초

원형띠철근 기둥의 내진거동에 관한 실험적 연구 (The Experimental Study on Seismic Behavior of Circular-Tied Columns)

  • 석상근;고성현;윤석구;이재훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.369-374
    • /
    • 2000
  • This study was conducted to investigate the seismic behavior assessment of circlular-tied bridge piers, particularly with regard to assessing the displacement ductility. The experimental variables of bridge piers test consisted of transverse steel details, amount and spacing different axial load levels etc. The test results indicated that reinforcement concrete bridge piers with confinement steel by the code specification exhibited sufficient ductile behavior and seismic performance. Aldo, it is found that current seismic design code specification of confinement steel requirements may be revised.

  • PDF

오대산 지진자료에 의한 거리감쇠식 추정에 관한 연구 (A Study on the Presumption for Attenuation Relation by MT. O-dae earthquake data in Korea)

  • 권기혁;황완선;유혜란
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.33-36
    • /
    • 2008
  • In Korean Building Code 2005(KBC-2005), the Seismic Zone Factor is regulated by separating the seismic zone into two part. This seismic zone factor is not matched to regional seismic characteristics of our country because the factor is based on International Building Code 2000 (IBC-2000) of USA. This study inquiry for having a sufficient grasp of the seismic characteristics of south Korea region and appling for the seismic cope plan. We have collected and analyzed earthquake record happened in domestic region. There are two kinds of earthquake record. One is Historical earthquake data, another is Instrumental earthquake data. I used Instrumental earthquake record data which reliance is higher than historical earthquake data for proposing attenuation formulas by analyzing a correlation the epicenter and the distance.

  • PDF

국내 옹벽의 유사정적 내진설계기준 개선방향에 대한 고찰 (A Discussion on the Improvement of Pseudo-Static Seismic Design Criteria of Retaining Wall in Domestic)

  • 조성배;하정곤;이진선;김동수
    • 한국지진공학회논문집
    • /
    • 제19권2호
    • /
    • pp.45-53
    • /
    • 2015
  • This paper reviews the current seismic design code and research for dynamic earth pressure on retaining structures. Domestic design codes do not clearly define the estimation of dynamic earth pressure and give different comments for seismic coefficient, wall inertia and distribution of dynamic earth pressure using Mononobe-Okabe method. AASHTO has been revised reflecting current research and aims for effective seismic design. Various design codes are analyzed to compare their performance and economic efficiency. The results are used to make improvement of current domestic seismic design code. Further, it is concluded that the experimental investigation is also needed to verify and improve domestic seismic code for dynamic earth pressure.

강재댐퍼를 적용한 역사 건물의 내진 응답 (Seismic Resistance Response of Railway Station Building Retrofitted by Metallic Dampers)

  • 이현호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권2호
    • /
    • pp.82-88
    • /
    • 2010
  • 본 연구의 목적은 내진규준이 적용되기 이전에 건설된 역사건물의 내진성능 평가 및 내진보강이다. 이를 위하여 2층 RC 역사건물의 내진성능이 평가되었다. 동적해석에 의한 층간변위비 및 층전단력 평가결과, 층전단력이 설계기준의 밑면전단력을 초과하는 것으로 평가되어 적절한 내진보강이 필요한 것으로 평가되었다. 내진성능 향상을 위하여 총 4개의 강재댐퍼가 사용되었다. 해석 변수는 강재댐퍼 형상 및 설치 방법이다. 동적해석결과 역 K가새로 설치되는 슬릿댐퍼가 다른 댐퍼 형상 및 설치 방법보다 우수한 내진성능을 가진 것으로 평가되었다.

Post-earthquake warning for Vrancea seismic source based on code spectral acceleration exceedance

  • Balan, Stefan F.;Tiganescu, Alexandru;Apostol, Bogdan F.;Danet, Anton
    • Earthquakes and Structures
    • /
    • 제17권4호
    • /
    • pp.365-372
    • /
    • 2019
  • Post-earthquake crisis management is a key capability for a country to be able to recover after a major seismic event. Instrumental seismic data transmitted and processed in a very short time can contribute to better management of the emergency and can give insights on the earthquake's impact on a specific area. Romania is a country with a high seismic hazard, mostly due to the Vrancea intermediate-depth earthquakes. The elastic acceleration response spectrum of a seismic motion provides important information on the level of maximum acceleration the buildings were subjected to. Based on new data analysis and knowledge advancements, the acceleration elastic response spectrum for horizontal ground components recommended by the Romanian seismic codes has been evolving over the last six decades. This study aims to propose a framework for post-earthquake warning based on code spectrum exceedances. A comprehensive background analysis was undertaken using strong motion data from previous earthquakes corroborated with observational damage, to prove the method's applicability. Moreover, a case-study for two densely populated Romanian cities (Focsani and Bucharest) is presented, using data from a $5.5M_W$ earthquake (October 28, 2018) and considering the evolution of the three generations of code-based spectral levels for the two cities. Data recorded in free-field and in buildings were analyzed and has confirmed that no structural damage occurred within the two cities. For future strong seismic events, this tool can provide useful information on the effect of the earthquake on structures in the most exposed areas.

State of Practice of Performance-Based Seismic Design in Indonesia

  • Sukamta, Davy;Alexander, Nick
    • 국제초고층학회논문집
    • /
    • 제1권3호
    • /
    • pp.211-220
    • /
    • 2012
  • The current 2002 Indonesian Seismic Code consists of prescriptive criteria that are intended to result in buildings capable of providing certain levels of performance. However, the actual performance capability of buildings is not assessed as part of the code procedures. Several analysis procedures are allowed, and the state of practice is to use the RSA with six-zone seismic map developed for 475-year earthquake. This code is being revised and will adopt many of the ASCE7-10 provisions and 2475-year earthquake for MCE. The growth of tall buildings compels engineers to look for more optimal lateral system. The use of RC core wall as single system has been adopted by very few engineering firms, which is allowed in the current code but will no longer be the case if the new one is in effect. Other innovative structural system such as core wall and outrigger is not addressed in the proposed new code. Engineers must then resort to NLRHA. Currently, one 50-story building under construction using RC core wall and outrigger has been designed with RSA and employing capacity design principles, then evaluated using NLRHA per TBI Guidelines. Based on the evaluation, the performance of the 50-story building generally still meets the criteria of the TBI Guidelines. The result of the case study is presented in this paper.

A comparative study on the seismic provisions of different codes for RC buildings

  • Bilgin, Huseyin;Hadzima-Nyarko, Marijana;Isik, Ercan;Ozmen, Hayri Baytan;Harirchian, Ehsan
    • Structural Engineering and Mechanics
    • /
    • 제83권2호
    • /
    • pp.195-206
    • /
    • 2022
  • Significant structural damages due to earthquakes reveal the importance of seismic design provisions. This paper presents a comparison between the seismic design provisions of Albania, Croatia, Iran, and Turkey for the design of mid-rise reinforced-concrete (RC) frames. Information on the historical development of the considered provisions are given. The code provisions are compared, illustrating the main differences in the minimum requirements for column and beam detailing and analysis for mid-rise RC frames. 4-story, 5-story, and 6-story buildings are designed according to each design code, and their performance is evaluated comparatively by using a displacement-based adaptive pushover procedure and eigenvalue analysis. It is observed that recent Turkish code has the highest and Albanian code has the lowest level of requirements in terms of member size and reinforcement detailing. The considered models indicate 15%, 20% and 50%, lower period values than the Croatia, Iran and Albania buildings, respectively. Additionally, building models per Croatia, Iran and Albania codes have 30%, 35% and 65% less base shear capacity when compared to Turkish building codes. Building models per Croatia and Iran codes indicate similar properties both in terms of strength and stiffness.

잔교식 항만구조물의 내진설계기준에 관한 연구 (A Study of the Seismic Design Guidelines for Marginal Wharf Structures)

  • 김문겸
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.188-195
    • /
    • 1998
  • The seismic design guidelines for the pile-supported marginal wharf structures are studied. Various design codes such as AASHTO code or UBC code, which are focused on general structures, may be referred for the design of the wharf structures. However, in developing domestic design code, special consideration should be made concerning the size of the earthquake and the type of the structure. This study aims at the comparison among the various design codes for a specific wharf structure in the process of developing a domestic design code.

  • PDF

Seismic Performance of High-rise Concrete Buildings in Chile

  • Lagos, Rene;Kupfer, Marianne;Lindenberg, Jorge;Bonelli, Patricio;Saragoni, Rodolfo;Guendelman, Tomas;Massone, Leonardo;Boroschek, Ruben;Yanez, Fernando
    • 국제초고층학회논문집
    • /
    • 제1권3호
    • /
    • pp.181-194
    • /
    • 2012
  • Chile is characterized by the largest seismicity in the world which produces strong earthquakes every $83{\pm}9years$ in the Central part of Chile, where it is located Santiago, the capital of Chile. The short interval between large earthquakes magnitude 8.5 has conditioned the Chilean seismic design practice to achieve almost operational performance level, despite the fact that the Chilean Code declares a scope of life safe performance level. Several Indexes have been widely used throughout the years in Chile to evaluate the structural characteristics of concrete buildings, with the intent to find a correlation between general structural conception and successful seismic performance. The Indexes presented are related only to global response of buildings under earthquake loads and not to the behavior or design of individual elements. A correlation between displacement demand and seismic structural damage is presented, using the index $H_o/T$ and the concrete compressive strain ${\varepsilon}_c$. Also the Chilean seismic design codes pre and post 2010 Maule earthquake are reviewed and the practice in seismic design vs Performance Based Design is presented. Performance Based Design procedures are not included in the Chilean seismic design code for buildings, nevertheless the earthquake experience has shown that the response of the Chilean buildings has been close to operational. This can be attributed to the fact that the drift of most engineered buildings designed in accordance with the Chilean practice falls below 0.5%. It is also known by experience that for frequent and even occasional earthquakes, buildings responded elastically and thus with "fully operational" performance. Taking the above into account, it can be said that, although the "basic objective" of the Chilean code is similar to the SEAOC VISION2000 criteria, the actual performance for normal buildings is closer to the "Essential/Hazardous objective".

내진설계기준의 지반분류체계 및 설계응답스펙트럼 개선을 위한 연구 - (I) 데이터베이스 및 지반응답해석 (Site Classification and Design Response Spectra for Seismic Code Provisions - (I) Database and Site Response Analyses)

  • 조형익;;김동수
    • 한국지진공학회논문집
    • /
    • 제20권4호
    • /
    • pp.235-243
    • /
    • 2016
  • Korea is part of a region of low to moderate seismicity located inside the Eurasian plate with bedrock located at depths less than 30 m. However, the spectral acceleration obtained from site response analyses based on the geologic conditions of inland areas of the Korean peninsula are significantly different from the current Korean seismic code. Therefore, suitable site classification scheme and design response spectra based on local site conditions in the Korean peninsula are required to produce reliable estimates of earthquake ground motion. In this study, site-specific response analyses were performed at more than 300 sites with at least 100 sites at each site categories of $S_C$, $S_D$, and $S_E$ as defined in the current seismic code in Korea. The process of creating a huge database of input parameters - such as shear wave velocity profiles, normalized shear modulus reduction curves, damping curves, and input earthquake motions - for site response analyses were described. The response spectra and site coefficients obtained from site response analyses were compared with those proposed for the site categories in the current code. Problems with the current seismic design code were subsequently discussed, and the development and verifications of new site classification system and corresponding design response spectra are detailed in companion papers (II-development of new site categories and design response spectra and III-Verifications)