• 제목/요약/키워드: segmental scoring

검색결과 13건 처리시간 0.032초

Usefulness of ultrasound contrast media for cardiac output measurement with echocardiography

  • Yun, Je Woong;Yeon, Seong Chan;Lee, Hee Chun
    • 대한수의학회지
    • /
    • 제55권1호
    • /
    • pp.47-52
    • /
    • 2015
  • The purpose of this study was to determine if contrast media would enhance visualization of the endocardium for assessment of left ventricle (LV) function. In addition, differences between pre- and post-contrast evaluation for the cardiac output measurements including the modified Simpson's method and automated contour tracking (ACT) method were examined. Ten clinically healthy adult beagle dogs (three males and seven females) between 2~3 years old and weighing 6.6~10.8 kg were used. Echocardiographic examinations were performed to compare pre- and post-contrast LV endocardium visualization using a segmental scoring method. Two different methods for measuring cardiac output were also compared. LV visualization was significantly enhanced in post-contrast echocardiography (p < 0.01). Significant differences between pre- and post-contrast measurements for the modified Simpson's method (p < 0.05) were also observed. No significant difference was found for the ACT method. Contrast echocardiography provides better LV chamber opacification and significantly improves wall segment visualization. Furthermore, contrast echocardiography for measuring cardiac output is helpful for the modified Simpson's method.

$^{99m}Tc$-MIBI 심근 SPECT의 분절 육안 분석시 판독자간의 일치도 (Interobserver Reproducibility of Segmental Scoring of $^{99m}Tc$-MIBI Myocardial SPECT)

  • 여정석;이동수;이경한;김종호;손경수;조성욱;곽철은;정준기;이명철;서종돈;고창순
    • 대한핵의학회지
    • /
    • 제28권3호
    • /
    • pp.317-325
    • /
    • 1994
  • 디피리다몰 부하/휴식 $^{99m}Tc$-MIBI 심근 SPECT에 의한 심혈관질환의 진단과 심근분절별 혈류등급의 재현성을 조사하여 판독자의 주관적인 판단이 SPECT 판독에 미치는 영향을 알아보았다. 디피리다몰 부하/휴식 $^{99m}Tc$-MIBI 심근 SPECT와 심혈관 조영술을 2개월이내에 동시에 시행한 환자 131명에서 환자의 임상정보를 모르는 두 명의 판독자가 독립적으로 스캔을 판독하였다. 1) 심혈관조영소견을 기준으로 하였을 때 전체환자 131명에 대한 두명의 판독자의 SPECT진단의 예민도와 특이도는 각각 70%, 73%와 58%, 54%였고 정확도는 67%, 70%로 판독자간에 유의한 차이가 없었다. 외래에서 SPECT 검사를 의뢰한 환자와 SPECT를 먼저 시행하고 관동맥조영술을 나중에 시행한 환자에서에서 두 판독자의 스캔진단 정확도가 입원 상태에서 SPECT를 실시한 환자와 관동맥조영술을 먼저 시행한 환자의 경우에서보다 진단정확도가 높았다. 2) 스캔판독시 두명의 판독자간의 심혈관질환의 유무에 대한 최종 스캔진단의 일치도는 93%였으며 각영역별로 구한 일치도는 89%였다. 3) 두 판독자가 29개 심근분절의 혈류에 대해서 부여한 점수는 80%에서 일치하였으며 분절점수간의 상관계수는 0.67이었다. 스캔판독이 일치하였던 경우와 일치하지 않았던 경우의 분절심근점수의 일치도에는 차이가 없어서 스캔판독의 차이가 혈류저하의 정도에 대한 평가의 차이이기보다는 영역별 혈류저하정도에 대하여 유의성여부를 판별하는 주관적 기준의 차이에 의한 것임을 시사하였다. 이상에서 심근 SPECT의 육안평가시 분절별 혈류저하 정도에 대한 평가는 판독자간에 높은 재현성을 보이며 심혈관질환의 유무에 대한 판정은 영역별로 유의한 혈류저하라고 생각하는 신뢰수준(confidence level)의 기준차이에 영향을 받는 것으로 생각되었다. 이러한 판독자별 기준의 차이가 진단에 대한 예민도 및 특이도에 영향을 주므로 분절분석평가방법을 이용하여 개인별로 적절한 평가기준을 설정하는 것이 정확한 SPECT 평가에 도움이 되리라 생각한다.

  • PDF

한국인 영어 학습자의 발음 정확성 자동 측정방법에 대한 연구 (A Study on Automatic Measurement of Pronunciation Accuracy of English Speech Produced by Korean Learners of English)

  • 윤원희;정현성;장태엽
    • 대한음성학회:학술대회논문집
    • /
    • 대한음성학회 2005년도 추계 학술대회 발표논문집
    • /
    • pp.17-20
    • /
    • 2005
  • The purpose of this project is to develop a device that can automatically measure pronunciation of English speech produced by Korean learners of English. Pronunciation proficiency will be measured largely in two areas; suprasegmental and segmental areas. In suprasegmental area, intonation and word stress will be traced and compared with those of native speakers by way of statistical methods using tilt parameters. Durations of phones are also examined to measure speakers' naturalness of their pronunciations. In doing so, statistical duration modelling from a large speech database using CART will be considered. For segmental measurement of pronunciation, acoustic probability of a phone, which is a byproduct when doing the forced alignment, will be a basis of scoring pronunciation accuracy of a phone. The final score will be a feedback to the learners to improve their pronunciation.

  • PDF

심근관류 SPECT의 분절별 관류 및 국소벽 운동에서 Wide Beam Reconstruction기법의 유용성 평가 (The Evaluation of Usefulness of Wide Beam Reconstruction Method on Segmental Perfusion and Regional Wall Motion in Myocardial Perfusion SPECT)

  • 성용준;김태엽;문일상;조성욱;우재룡
    • 핵의학기술
    • /
    • 제15권1호
    • /
    • pp.51-57
    • /
    • 2011
  • 광대역 재구성(wide beam reconstruction, WBR) 기법인 Xpress.cardiac$^{TM}$ 프로그램을 적용하여 기존 OSEM (ordered subsets expectation maximization) 기법과 심근 내 분절별 관류와 국소벽 운동에서의 일치율을 확인하여 WBR 기법의 임상적 유용성을 알아보고자 하였다. 관상동맥질환의 병력이 없고 핵의학 전문의에 의한 판독상 이상소견이 없는 총 20명(남7명, 여자13명: 정상군)과 관상동맥질환을 진단받은 총 10명(남6명, 여자4명: 비정상군)을 대상으로 휴식기 $^{201}Tl$/부하기 $^{99m}Tc$-MIBI 심근관류 SPECT를 실시하였다. 영상 획득과 재구성은 휴식기 시 투사영상당 30초, 곧바로 15초씩 영상을 얻고 부하기 시 투사영상 당 25초, 곧바로 13초씩 영상을 얻어 OSEM과 WBR 기법을 적용하였고 심근 내 분절별 관류과 국소벽 운동은 AutoQuant 프로그램의 QPS/QGS 알고리즘의 20분절 모델을 적용하였다. 관류상태는 5등급(0=정상, 1=경도, 2=중등도, 3=심한 결손, 4=섭취 없음), 국소벽 운동은 5등급(0=정상, 1=경도, 2=중등도, 3=심한운동저하, 4=무운동)으로 분류한 반정량값을 이용해 기존 OSEM 기법과 WBR 기법에서의 일치율을 평가하였다. 정상군에서 기존 OSEM 기법과 WBR 기법에서의 일치율은 휴식기 시 분절별 관류에서 99% (396/400, k=0.662, p<0.0001), 국소벽 운동에서 83.8% (335/400, k=0.283), 부하기 시 분절별 관류에서 95.8% (383/400, k=0.656), 국소벽 운동에서 87.3% (349/400, k=0.390)의 일치율을 보였다. 비정상군에서 휴식기 시 분절별 관류에서 83% (166/200, k=0.605), 국소벽 운동에서 55.5% (111/200, k=0.385), 부하기 시 분절별 관류에서 79.5% (159/200, k=0.682), 국소벽 운동에서 63.5% (127/200, k=0.486)의 일치율을 보였다. 관상동맥 질환의 진단 및 예후 예측에 있어 중요한 의미를 갖는 심근 내 분절별 관류와 국소벽 운동 기능 평가의 지표들을 이용한 WBR 기법은 기존 OSEM 기법과 비교하여 정상 비정상군 모두에서 심근 내 분절별 관류의 일치율은 높았지만 국소벽 운동에서는 의미 있게 낮은 일치율을 보였다. WBR 기법은 높은 해상도와 대조도를 제공할 수 있다고 하나 심근관류 SPECT에서의 적용은 유용성이 떨어진다고 사료된다.

  • PDF

Building a Sentential Model for Automatic Prosody Evaluation

  • 윤규철
    • 말소리와 음성과학
    • /
    • 제1권4호
    • /
    • pp.47-59
    • /
    • 2009
  • The purpose of this paper is to propose an automatic evaluation technique for the prosodic aspect of an English sentence uttered by Korean speakers learning English. The underlying hypothesis is that the consistency of the manual prosody scoring is reflected in an imaginary space of prosody evaluation model constructed out of the three physical properties of the prosody considered in this paper, namely: the fundamental frequency (F0) contour, the intensity contour, and the segmental durations. The evaluation proceeds first by building a prosody evaluation model for the sentence. For the creation of the model, utterances from native speakers of English and Korean learners for the target sentence are manually scored by either native teachers of English or Korean phoneticians in terms of their prosody. Multiple native utterances from the manual scoring are selected as the "model" native utterances against which all the other Korean learners' utterances as well as the model utterances themselves can be semi-automatically evaluated by comparison in terms of the three prosodic aspects [7]. Each learner utterance, when compared to the multiple model native utterances, produces multiple coordinates in a three-dimensional space of prosody evaluation, each axis of which corresponds to the three prosodic aspects. The 3D coordinates from all the comparisons form a prosody evaluation model for the particular sentence and the associated manual scores can display regions of particular scores. The model can then be used as a predictive model against which other Korean utterances of the target sentence can be evaluated. The model from a Korean phonetician appears to support the hypothesis.

  • PDF

Semi-Quantitative Scoring of Late Gadolinium Enhancement of the Left Ventricle in Patients with Ischemic Cardiomyopathy: Improving Interobserver Reliability and Agreement Using Consensus Guidance from the Asian Society of Cardiovascular Imaging-Practical Tutorial (ASCI-PT) 2020

  • Cherry Kim;Chul Hwan Park;Do Yeon Kim;Jaehyung Cha;Bae Young Lee;Chan Ho Park;Eun-Ju Kang;Hyun Jung Koo;Kakuya Kitagawa;Min Jae Cha;Rungroj Krittayaphong;Sang Il Choi;Sanjaya Viswamitra;Sung Min Ko;Sung Mok Kim;Sung Ho Hwang;Nguyen Ngoc Trang;Whal Lee;Young Jin Kim;Jongmin Lee;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • 제23권3호
    • /
    • pp.298-307
    • /
    • 2022
  • Objective: This study aimed to evaluate the effect of implementing the consensus statement from the Asian Society of Cardiovascular Imaging-Practical Tutorial 2020 (ASCI-PT 2020) on the reliability of cardiac MR with late gadolinium enhancement (CMR-LGE) myocardial viability scoring between observers in the context of ischemic cardiomyopathy. Materials and Methods: A total of 17 cardiovascular imaging experts from five different countries evaluated CMR obtained in 26 patients (male:female, 23:3; median age [interquartile range], 55.5 years [50-61.8]) with ischemic cardiomyopathy. For LGE scoring, based on the 17 segments, the extent of LGE in each segment was graded using a five-point scoring system ranging from 0 to 4 before and after exposure according to the consensus statement. All scoring was performed via web-based review. Scores for slices, vascular territories, and total scores were obtained as the sum of the relevant segmental scores. Interobserver reliability for segment scores was assessed using Fleiss' kappa, while the intraclass correlation coefficient (ICC) was used for slice score, vascular territory score, and total score. Inter-observer agreement was assessed using the limits of agreement from the mean (LoA). Results: Interobserver reliability (Fleiss' kappa) in each segment ranged 0.242-0.662 before the consensus and increased to 0.301-0.774 after the consensus. The interobserver reliability (ICC) for each slice, each vascular territory, and total score increased after the consensus (slice, 0.728-0.805 and 0.849-0.884; vascular territory, 0.756-0.902 and 0.852-0.941; total score, 0.847 and 0.913, before and after implementing the consensus statement, respectively. Interobserver agreement in scoring also improved with the implementation of the consensus for all slices, vascular territories, and total score. The LoA for the total score narrowed from ± 10.36 points to ± 7.12 points. Conclusion: The interobserver reliability and agreement for CMR-LGE scoring for ischemic cardiomyopathy improved when following guidance from the ASCI-PT 2020 consensus statement.

심초음파의 조영제의 임상적 유용성: 개에서 좌심영상화에 대한 조영제 용량의 영향 (Clinical Usefulness of Contrast Echocardiography: The Dose Effect for Left Ventricle Visualization in Dogs)

  • 신창호;황태성;윤영민;정동인;연성찬;이희천
    • 한국임상수의학회지
    • /
    • 제32권6호
    • /
    • pp.486-490
    • /
    • 2015
  • 이차원 초음파는 심장 기능의 평가에 있어 널리 이용되어지고 있다. 심혈관계 질환의 진단을 위해서는 좌심실 내강의 영상화가 필수적이다. SonoVue$^{TM}$는 육불화황 가스로 안정화된 새로 나온 조영제이다. 현재 이 초음파 조영제를 이용하여 활발한 연구가 진행되고 있으나, 개에서 진단을 위한 가장 효율적인 용량에 대한 연구가 없었다. 이 연구의 목적은 SonoVue$^{TM}$ 조영제를 이용하여 좌심실 내강의 영상화에 있어 효율적인 용량을 찾는데 있다. 열 마리의 건강한 비글 성견을 실험에 이용하였다. 본 연구에서는 조영제의 용량을 각 0.03 ml/kg, 0.05 ml/kg 그리고 0.1 ml/kg 으로 사용하여 각 용량에서의 좌심실 내강의 영상화 되는 시간을 비교하였다. 내강이 영상화되는 시간의 측정은 segmental score를 이용하였다. Segmental score법은 좌심실 내강을 6개의 가상의 구역으로 나누고 각 구역이 영상화되는 것을 수치화 하는 방법이다. 본 연구에서는 일반적으로 유의성이 있다고 할 수있는 segmental score가 5이상일 때의 시간을 측정하였다. 그리고 재연성의 평가를 위해 3명의 관찰자가 실험에 동참하였다. 측정치의 통계분석은 SPSS 14.0버전에서 일원배치 분산분석과 Scheffe 다중 비교를 이용하였다. 각 용량에서(0.03 ml/kg, 0.05 ml/kg, 0.1 ml/kg) 좌심실이 영상화 되는 평균 시간은 3.54초, 6.15초, 24.39초로 나타났다. 표준편차는 각 용량별 2.14124, 2.61205, 11.09802로 나타났다. 실험에 참여한 모든 동물에서 과민 반응, 심마진, 혈관 부종 등의 부작용이 나타나지 않았다. 결론적으로 소노뷰 조영제를 이용하여 좌심실 내강의 영상화시 가장 효율적인 조영제의 용량은 단위체중당 0.1 ml/kg이며, 이 용량에서 재연성 역시 가장 높았다.

폴라루스 골수정을 이용한 상완골 근위부 골절의 치료 (Treatment of Proximal Humerus Fracture by Polarus Nailing)

  • 최창혁;권굉우;정대의;장호진
    • Clinics in Shoulder and Elbow
    • /
    • 제9권2호
    • /
    • pp.169-175
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate the usefullness of polarus nailing in the treatment of proximal humerus fractures including 2 part, 3 part and proximal comminuted fractures. Materials and methods: Fifteen cases of proximal humerus fracture treated with Polarus nailing from March, 2002 to March, 2004 were selected. Man was 3 cases, and woman was 11 cases. There were one case of follow up loss due to decease. Average age was 60 years old (range, 23 to 84), and there were 6 cases of 2 part fracture, 3 cases of proximal segmental fracture, 5 cases of 3 part fracture. We analyzed the outcom results between 2 part fracture and 3 part fracture. The average follow up period after the operation was 1.5(range, 1 to 2) years. Range of motion (ROM), pain and functional outcome were evaluated by visual analogue scale(VAS) and american shoulder and elbow surgery (ASES) activity of daily living (ADL) functional scoring system. Results: All cases showed union on radiologic evaluation, with 2.3 months follow up. In 5 cases of 3 part fracture, average union time was 1.9 months regardless of proximal screw loosening in 4 cases. In 2 part fracture union time was 2.2 months (P>0.05). VAS pain score was 1.3, ROM was $160^{\circ}$ in forward flexion, $40^{\circ}$ in external rotation, L3 level in internal rotation, and ASES, ADL functional score was 21 in 2 part fracture. VAS pain score was 1.25, ROM was $160^{\circ}$, $43^{\circ}$ and L1 level, and ASES, ADL functional score was 21 in 3 part fracture. There were no statistically significant difference between two groups (P>0.05) VAS pain score was 1.6, ROM was $170^{\circ}$, $47^{\circ}$ and L3 level, and ASES, ADL functional score was 23 in proximal comminuted fracture. Conclusion: Polarus nailing could be used as an effective modality in certain cases of proximal humeral fracture including 2 part, proximal segmental and in cases of 3 part fractures with large greater tuberosity fragment.

A Comparative Study on Internal Fixation Using Long Proximal Intramedullary Nail for the Treatment of Humeral Shaft Fracture according to Fracture Types

  • Choi, Chang-Hyuk;Jun, Chung-Mu;Kim, Jun-Young
    • Clinics in Shoulder and Elbow
    • /
    • 제22권2호
    • /
    • pp.87-92
    • /
    • 2019
  • Background: This study was conducted to compare the radiological and clinical outcomes of internal fixation using a Polarus humeral nail for treatment of a humeral shaft fracture according to fracture types. Methods: From 43 patients, 13 were excluded and 30 patients were included. The 30 patients were divided into 2 groups: 15 in group I (Orthopaedic Trauma Association/Arbeitsgemeinschaft $f{\ddot{u}}r$ Osteosynthesefragen classification type A and B) and 15 in group II (type C). The mean age was 63.1 years (range, 20-87 years), and mean follow-up period was 2.3 years (range, 1.0-6.1 years). The causes of injuries were as follows: 12, traffic accidents; 14, simple slips; 2, simple falls; 2, contusions after lower energy trauma. Radiological and clinical evaluations were performed. Results: Radiological union was confirmed by plain anteroposterior and lateral radiographs on average of 5.0 months in group I, and 8.4 months in group II, respectively. Differences between the two groups were statistically significant (p<0.01). The clinical union value was 1.6 in group I, and 2.0 months in group II, but these values did not differ significantly (p=0.441). The mean Korean shoulder scoring system scores were 89.7 and 90.6, which did not differ significantly (p=0.352). Conclusions: Intramedullary nailing using the Polarus humeral nail is considered to be a good treatment modality for all types of humeral shaft fractures. Additionally, the Polarus humeral nail can be an optimal choice for the treatment of complex type fractures such as segmental or comminuted humeral shaft fractures.

상완골 간부 골절에서의 전향적 교합성 골수강내 금속정 고정술 (Antegrade Interlocking Intramedullary Nailing in Humeral Shaft Fractures)

  • 조철현;송광순;김신기
    • Clinics in Shoulder and Elbow
    • /
    • 제13권1호
    • /
    • pp.1-6
    • /
    • 2010
  • 목적: 상완골 간부 골절에서의 전향적 교합성 골수강내 금속정 고정술의 치료 결과 및 합병증에 대하여 알아 보고자 한다. 대상 및 방법: 2002년부터 2008년까지 상완골 간부 골절로 전향적 교합성 골수강내 금속정 고정술을 시행하고 골유합 기간까지 추시 관찰이 가능하였던 47예를 대상으로 임상적, 방사선학적 결과 및 술 후 합병증을 분석하였다. 술 후 추시 단순 방사선 검사로 골유합을 확인하였고, ASES 점수 평가법을 이용하여 임상적 평가를 시행하였다. 결과: 총 47예 중 41예 (87.2%)에서 골유합을 보였고, 평균 유합 시기는 14.5주였다. 주요 합병증으로 불유합이 6예, 지연 유합이 3예, 술 중 원위 상완골 후방 피질 골절이 2예, 견관절 유착성 관절막염이 1예를 포함한 영구적 견관절 동통이 2예 있었다. 임상적 결과는 우수가 29예, 양호가 11예, 보통이 4예, 불량이 3예로, 40예 (85.1%)에서 만족할 만한 결과를 보였다. 결론: 상완골 간부 골절에서의 전향적 교합성 골수강내 금속정 고정술은 만족할만한 골유합율 및 임상적 결과를 나타내었으며, 특히 다발성 골절 등의 동반 손상이 있는 경우 또는 분절 골절에서 유용한 하나의 치료 방법이라 사료된다.