• Title/Summary/Keyword: segmental algorithm

Search Result 45, Processing Time 0.021 seconds

Tone Quality Improvement Algorithm using Intelligent Estimation of Noise Pattern (잡음 패턴의 지능적 추정을 통한 음질 개선 알고리즘)

  • Seo, Joung-Kook;Cha, Hyung-Tai
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.15 no.2
    • /
    • pp.230-235
    • /
    • 2005
  • In this paper, we propose an algorithm that improves a tone quality of a noisy audio signal in order to enhance a performance of perceptual filter using intelligent estimation of noise pattern from a band degraded by additive noise. The proposed method doesn't use the estimated noise which is obtained from silent range. Instead new estimated noise according to the power of signal and effect of noise variation is considered for each frame. So the noisy audio signal is enhanced by the method which controls a estimation of noise Pattern effectively in a noise corruption band. To show the performance of the proposed algorithm, various input signals which had a different signal-to-noise ratio(SNR) such as $5\cal{dB},\;10\cal{dB},\;15\cal{dB}\;and\;20\cal{dB}$ were used to test the proposed algorithm. we carry out SSNR and NMR of objective measurement and MOS test of subjective measurement. An approximate improvement of $7.4\cal{dB},\;6.8\cal{dB},\;5.7\cal{dB},\;5.1\cal{dB}$ in SSNR and $15.7\cal{dB},\;15.5\cal{dB},\;15.2\cal{dB},\;14.8\cal{dB}$ in NMR is achieved with the input signals, respectively. And we confirm the enhancement of tone quality in terms of mean opinion score(MOS) test which is result of subjective measurement.

A Fast Pitch Searching Algorithm Using Correlation Characteristics in CELP Vocoder (상관관계 특성을 용한 CELP 보코더의 고속 피치검색 알고리듬)

  • Lee, Joo-Hun;Bae, Myung-Jin;Ann, Sou-Guil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.2E
    • /
    • pp.20-25
    • /
    • 1994
  • The major drawback to the Code Excited Linear Prediction(CELP) type vocoders is their large computational requirements. In this paper, a simple method is proposed to reduce the pitch searching time in the pitch filter almost without degradation of quality. Bease upon the observational regularity of the correlation function of speech, the searching range can be restricted to the positive side in pitch search. This is done by skipping the negative side with the width which is estimated from the previous positive envelope. In addition to that, the maximum number of available lags can be limited by the threshold, $L_T$, which is set on 58 empirically. So, only the limited numbers of lags are considered in pitch search, which is less than a half of that of the full search method. By using the proposed method in pitch search, its required computations are greatly reduced. Experimental result shows 51% time reduction almost without lowering the speech quality in segmental SNR measure.

  • PDF

Displacement Based Seismic Performance Improved Design of RC Column Retrofitted Steel Jacket (변위기반 설계법에 의한 RC 기둥의 Steel Jacket 보강 내진성능개선 설계법)

  • Jung, In-Kju;Cho, Chang-Geun;Park, Soon-Eung
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.4
    • /
    • pp.49-57
    • /
    • 2010
  • This study is the research appling the representative Displacement-Based Design which is the basic concept of Direct Displacement Based Design proposed by Chopra and Goel to original Reinforced Concrete structure and determining the thickness of retrofit Steel Jacket about the Maximum design ground acceleration, and developing the more improved Algorithm as well as program by the Retrofit Design method and Nonlinear analysis by the Performance design method before and after reinforcement appling the determined retrofit thickness. To predict the target displacement of retrofitted columns, a nonlinear analysis model of reinforced concrete columns has been developed to be based on the nonlinear fiber cross-sectional and segmental analysis model, and the seismic displacement level of retrofitted columns is estimated by two procedures, the direct displacement-based design method and the displacement coefficient method. In examples of seismic retrofit design, the current seismic improved design method gives good results in improvements of displacement levels and displacement ductilities of retrofitted columns.

  • PDF

Semi-active storey isolation system employing MRE isolator with parameter identification based on NSGA-II with DCD

  • Gu, Xiaoyu;Yu, Yang;Li, Jianchun;Li, Yancheng;Alamdari, Mehrisadat Makki
    • Earthquakes and Structures
    • /
    • v.11 no.6
    • /
    • pp.1101-1121
    • /
    • 2016
  • Base isolation, one of the popular seismic protection approaches proven to be effective in practical applications, has been widely applied worldwide during the past few decades. As the techniques mature, it has been recognised that, the biggest issue faced in base isolation technique is the challenge of great base displacement demand, which leads to the potential of overturning of the structure, instability and permanent damage of the isolators. Meanwhile, drain, ventilation and regular maintenance at the base isolation level are quite difficult and rather time- and fund- consuming, especially in the highly populated areas. To address these challenges, a number of efforts have been dedicated to propose new isolation systems, including segmental building, additional storey isolation (ASI) and mid-storey isolation system, etc. However, such techniques have their own flaws, among which whipping effect is the most obvious one. Moreover, due to their inherent passive nature, all these techniques, including traditional base isolation system, show incapability to cope with the unpredictable and diverse nature of earthquakes. The solution for the aforementioned challenge is to develop an innovative vibration isolation system to realise variable structural stiffness to maximise the adaptability and controllability of the system. Recently, advances on the development of an adaptive magneto-rheological elastomer (MRE) vibration isolator has enlightened the development of adaptive base isolation systems due to its ability to alter stiffness by changing applied electrical current. In this study, an innovative semi-active storey isolation system inserting such novel MRE isolators between each floor is proposed. The stiffness of each level in the proposed isolation system can thus be changed according to characteristics of the MRE isolators. Non-dominated sorting genetic algorithm type II (NSGA-II) with dynamic crowding distance (DCD) is utilised for the optimisation of the parameters at isolation level in the system. Extensive comparative simulation studies have been conducted using 5-storey benchmark model to evaluate the performance of the proposed isolation system under different earthquake excitations. Simulation results compare the seismic responses of bare building, building with passive controlled MRE base isolation system, building with passive-controlled MRE storey isolation system and building with optimised storey isolation system.

Imaging Findings of Peripheral Arterial Disease on Lower-Extremity CT Angiography Using a Virtual Monoenergetic Imaging Algorithm (가상의 단일 에너지 영상 재구성 기법을 이용한 하지 단층촬영 혈관조영술에서 말초 동맥 질환 영상 소견)

  • Jun Seong Kim;So Hyun Park;Suyoung Park;Jung Han Hwang;Jeong Ho Kim;Seong Yong Pak;Kihyun Lee;Bernhard Schmidt
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.5
    • /
    • pp.1032-1045
    • /
    • 2022
  • Peripheral arterial disease (PAD) is common in elderly patients. Lower-extremity CT angiography (LE-CTA) can be useful for detecting PAD and planning its treatment. PAD can also be accurately evaluated on reconstructed monoenergetic images (MEIs) from low kiloelectron volt (keV) to high keV images using dual-energy CT. Low keV images generally provide higher contrast than high keV images but also feature more severe image noise. The noise-reduced virtual MEI reconstruction algorithm, called the Mono+ technique, was recently introduced to overcome such image noise. Therefore, this pictorial review aimed to present the imaging findings of PAD on LE-CTA and compare low and high keV images with those subjected to the Mono+ technique. We found that, in many cases, the overall and segmental image qualities were better and metal artifacts and venous contamination were decreased in the high keV images.