• 제목/요약/키워드: secondary wave system

검색결과 86건 처리시간 0.049초

단일 센서 방식의 적응 능동 소음제어 (Adaptive Active Noise Control of Single Sensor Method)

  • 김영달;장석구
    • 소음진동
    • /
    • 제10권6호
    • /
    • pp.941-948
    • /
    • 2000
  • Active noise control is an approach to reduce the noise by utilizing a secondary noise source that destructively interferes with the unwanted noise. In general, active noise control systems rely on multiple sensors to measure the unwanted noise field and the effect of the cancellation. This paper develops an approach that utilizes a single sensor. The noise field is modeled as a stochastic process, and an adaptive algorithm is used to adaptively estimate the parameters of the process. Based on these parameter estimates, a canceling signal is generated. Oppenheim assumed that transfer function characteristics from the canceling source to the error sensor is only a propagation delay. This paper proposes a modified Oppenheim algorithm by considering transfer characteristics of speaker-path-sensor This transfer characteristics is adaptively cancelled by the proposed adaptive modeling technique. Feasibility of the proposed method is proved by computer simulations with artificially generated random noises and sine wave noise. The details of the proposed architecture. and theoretical simulation of the noise cancellation system for three dimension enclosure are presented in the Paper.

  • PDF

고 에너지 밀도 펄스 변압기 설계 (Design of A High Energy Density Pulse Transformer)

  • 남상훈;박성수;하기만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2186-2188
    • /
    • 1999
  • A high frequency and energy density pulse transformer is a critical component of a high voltage power supply in a traveling wave tube (TWT) amplifier system. In this paper, processes of design, manufacturing, and test of the transformer are discussed. Primary voltage of the transformer is 240 V. The transformer secondary have two outputs which are 4100 V (Helix) and 2050 V (Collector). Total output power is 860 W. Normal operating frequency of the transformer is 10 kHz. In high energy density pulse transformers, temperature rise is a main problem during its operation. From our study, it was found that resonant current due to leakage inductance and stray capacitance was the main cause of temperature rise. This happens because of the inherently high turn-ratio in high voltage transformers. Solutions to reduce stray components are presented.

  • PDF

Adaptive Filtering Processing for Target Signature Enhancement in Monostatic Borehole Radar Data

  • Hyun, Seung-Yeup;Kim, Se-Yun
    • Journal of electromagnetic engineering and science
    • /
    • 제14권2호
    • /
    • pp.79-81
    • /
    • 2014
  • In B-scan data measured by a pulse-type monostatic borehole radar, target signatures are seriously obscured by two clutters that differ in orientation and intensity. The primary clutter appears as a nearly constant time delay, which is caused by internal ringing between antenna and transceiver in the radar system. The secondary clutter occurs as an oblique time delay due to the guided borehole wave along the logging cable of the radar antenna. This issue led us to perform adaptive filtering processing for orientation-based clutter removal. This letter describes adaptive filtering processing consisting of a combination of edge detection, data rotation, and eigenimage filtering. We show that the hyperbolic signatures of a dormant air-filled tunnel target can be more distinctly enhanced by applying the proposed approach to the B-scan data, which are measured in a well-suited test site for underground tunnel detection.

LCL Resonant Compensation of Movable ICPT Systems with a Multi-load

  • Hua, Jie;Wang, Hui-Zhen;Zhao, Yao;Zou, Ai-Long
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1654-1663
    • /
    • 2015
  • Compared to LC resonance, LCL resonance has distinct advantages such as a large resonant capability, low voltage and current stresses of the power device, constant voltage or current output characteristics, and fault-tolerance capability. Thus, LCL resonant compensation is employed for a movable Inductive Contactless Power Transfer (ICPT) system with a multi-load in this paper, which achieves constant current output characteristics. Peculiarly, the primary side adopts a much larger compensation inductor than the primary leakage inductor to lower the reactive power, reduce the input current ripple, generate a large current in the primary side, and realize soft-switching. Furthermore, this paper proposes an approximate resonant point for large inductor-ratio LCL resonant compensation through fundamental wave analysis. In addition, the PWM control strategy is used for this system to achieve constant current output characteristics. Finally, an experimental platform is built, whose secondary E-Type coils can ride and move on a primary rail. Simulations and experiments are conducted to verify the effectiveness and accuracy of both the theory and the design method.

LED 2차 광학 시스템의 설계법 개발 (The Developement of Secondary Optics Design Method for LED)

  • 정승균;석대일;신화영;이창모;김훈
    • 조명전기설비학회논문지
    • /
    • 제21권6호
    • /
    • pp.26-32
    • /
    • 2007
  • 기존의 LED 광학계의 설계법은 크게 점광원 가정법과 가초점 설계법이 있으나, 이 설계법들은 LED와 광학계간의 거리가 매우 좁아지게 될 경우 큰 오차가 발생하는 단점이 존재하였다. 본 논문에서는 LED를 등간격으로 분할하여 각부분의 배광을 예측하고, 광선의 역추적 기법을 활용하여 이에 대한 결과를 확인한 후 분할된 각 구간에 대하여 세그먼트의 개별적인 설계를 통하여 오차를 감소시키는 새로운 설계법을 제시한다. 설계법의 설명이후에 2종의 예시 광학계를 설계하고 광학 성능 예측 프로그램을 통하여 배광과 광학 효율을 평가하였다.

자동차 실내 소음저감을 위한 다채널 능동소음 제어에 관한 연구 II : 모의 실험 (A Study on the Multi-Channel Active Noise Control for Noise Reduction of the Vehicle Cabin II : Semi-experiment)

  • 김흥섭;이태연;신준;오재응
    • 한국자동차공학회논문집
    • /
    • 제2권6호
    • /
    • pp.29-37
    • /
    • 1994
  • Active noise control of random noise which propatate in the vehicle cabin as a form of spherical wave is the target of this study. In the previous study, the adaptive algorithm for adaptive controller is presented for the application in active noise control system. And for the preliminary study of adaptive active noise control in vehicle cabin as a real system, a computer simulation is performed on the effectiveness of the adaptive algorithm in the amplitude of the pressure fluctuation. This work studies the implementation of multi-channel feedforward adaptive algorithm for the reduction of the noise inside a vehicle cabin using a number of secondary sources derived by adaptive filtering of reference noise source. Multi-channel adaptive feedforward algorithm are verified in numerical simulation and semi-experimental justification of developed system is made on a domestic passenger car. In the results of semi-experimental study, the noise of specific region in the interior of automobile are reduced for the appreciabe sound pressure level in the operating engine rpm and finally this study suggests the capabilities of the real time active noise control in 3 dimensional acoustic fields.

  • PDF

3차원 직사각형 노즐에서 역유동 추력벡터 제어 평가 (Assessment of the Counter-Flow Thrust Vector Control in a Three-Dimensional Rectangular Nozzle)

  • ;김태호;;김희동
    • 한국추진공학회지
    • /
    • 제24권1호
    • /
    • pp.34-46
    • /
    • 2020
  • 직사각형 초음속 노즐의 3차원 역유동 추력벡터 제어 시스템에 대한 공기역학적 특성을 조사하기 위하여 수치해석을 수행하였다. 이 초음속 노즐은 특성곡선법에 의하여 설계되었으며, 그 설계 마하수는 2.5이다. 2차 유동 덕트의 갭 높이를 변수로 하여 역유동 추력벡터 제어 시스템의 성능을 조사하였다. 상부 흡입 칼라의 중심선을 따르는 정압 분포, 편향각, 2차 질량유량비 및 합성 추력계수와 같은 주요 매개변수가 정량적으로 분석되었다. 또한 전체 유동장의 특성을 알아보기 위하여 대칭 평면에서의 유선, 3차원 등마하수분포 및 3차원 난류에너지분포를 조사하였다.

New Battery Balancing Circuit using Magnetic Flux Sharing

  • Song, Sung-Geun;Park, Seong-Mi;Park, Sung-Jun
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.194-201
    • /
    • 2014
  • To increase the capacity of secondary cells, an appropriate serial composition of the battery modules is essential. The unbalance that may occur due to the series connection in such a serial composition is the main cause for declines in the efficiency and performance of batteries. Various studies have been conducted on the use of a passive or active topology to eliminate the unbalance from the series circuit of battery modules. Most topologies consist of a complex structure in which the Battery Management System (BMS) detects the voltage of each module and establishes the voltage balancing in the independent electrical power converters installed on each module by comparing the module voltage. This study proposes a new magnetic flux sharing type DC/DC converter topology in order to remove voltage unbalances from batteries. The proposed topology is characterized by a design in which all of the DC/DC convertor outputs connected to the modules converge into a single transformer. In this structure, by taking a form in which all of the battery balancing type converters share magnetic flux through a single harmonic wave transformer, all of the converter voltages automatically converge to the same voltage. This paper attempts to analyze the dynamic properties of the proposed circuit by using a Programmable Synthesizer Interface Module (PSIM), which is useful for power electronics analysis, while also attempting to demonstrate the validity of the proposed circuit through experimental results.

가변형 음속 이젝터 유동에 관한 수치해석적 연구 (A Computational Study of a Variable Sonic Ejector Flow)

  • 이준희;최보규;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.526-531
    • /
    • 2003
  • A cone cylinder is used to obtain variable operation conditions of a sonic ejector-diffuser system. The cone cylinder is movable to change the ejector area ratio, thus obtaining variable mass flow rates. The present study investigates the effects of ejector throat area ratio and operating pressure ratio on the entrainment of secondary stream. The numerical simulations are based on a fully implicit finite volume scheme of the compressible, Reynolds-Averaged, Navier-Stokes equations. The ejector throat area is varied between 3.94 and 8.05, and the operating pressure ratio is changed from 3.0 to 9.0. The results show that the entrainment ratio and mass flux ratio become more dependent on the ejector throat area ratio, when the pressure operating ratio is low. The total pressure losses produced in the present ejector system increase with the operating pressure ratio and the ejector area ratio, but for a given operating pressure ratio, the losses are not significantly dependent on the ejector area ratio when it is larger than about 5.0.

  • PDF

흡기계 능동소음제어를 위한 적응형 필터 알고리즘의 개발 (Design of a New VSS-Adaptive Filter for a Potential Application of Active Noise Control to Intake System)

  • 김의열;김호욱;이상권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.231-239
    • /
    • 2009
  • The filtered-x LMS (FX-LMS) algorithm has been applied to the active noise control (ANC) system in an acoustic duct. This algorithm is designed based on the FIR (finite impulse response) filter, but it has a slow convergence problem because of a large number of zero coefficients. In order to improve the convergence performance, the step size of the LMS algorithm was modified from fixed to variable. However, this algorithm is still not suitable for the ANC system of a short acoustic duct since the reference signal is affected by the backward acoustic wave propagated from a secondary source. Therefore, the recursive filteredu LMS algorithm (FU-LMS) based on infinite impulse response (IIR) is developed by considering the backward acoustic propagation. This algorithm, unfortunately, generally has a stability problem. The stability problem was improved by using an error smoothing filter. In this paper, the recursive LMS algorithm with variable step size and smoothing error filter is designed. This recursive LMS algorithm, called FU-VSSLMS algorithm, uses an IIR filter. With fast convergence and good stability, this algorithm is suitable for the ANC system in a short acoustic duct such as the intake system of an automotive. This algorithm is applied to the ANC system of a short acoustic duct. The disturbance signals used as primary noise source are a sinusoidal signal embedded in white noise and the chirp signal of which the instantaneous frequency is variable. Test results demonstrate that the FU-VSSLMS algorithm has superior convergence performance to the FX-LMS algorithm and FX-LMS algorithm. It is successfully applied to the ANC system in a short duct.

  • PDF