• 제목/요약/키워드: secondary flow

Search Result 1,221, Processing Time 0.03 seconds

Modeling of Billet Shape in Spray Forming Process (분무성형공정에서의 빌렛형상 모델링)

  • Jang, Dong-Hun;Gang, Sin-Il;Lee, Eon-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.6
    • /
    • pp.961-970
    • /
    • 1997
  • A numerical method is presented to predict and analyze the shape of a growing billet produced from the "spray forming process" which is a fairly new near-net shape manufacturing process. It is important to understand the mechanism of billet growing because one can obtain a billet with the desired final shape without secondary operations by accurate control of the billet shape, and it can also serve as a base for heat transfer and deformation analysis. The shape of a growing billet is determined by the flow rate of the alloy melt, the mode of nozzle scanning which is due to cam profile, the initial positio of the spray nozzle, scanning angle, and the withdrawal speed of the substrate. In the present study, a theoretical model is first established to predict the shape of the billet and next the effects of the most dominent processing conditions, such as withdrawal speed of the substrate and the cam profile, on the shape of the growing billet are studied. Process conditions are obtained to produce a billet with uniform diameter and flat top surface, and an ASP30 high speed steel billet is manufactured using the same process conditions established from the simulation.imulation.

Verification experiment of a ground source multi-heat pump at cooling mode (지열원 시스템 히트펌프의 냉방 성능 특성에 관한 실증 연구)

  • Lim, Hyo-Jae;Kang, Shin-Hyung;Choi, Jae-Ho;Choi, Jong-Min;Moon, Je-Myung;Kwon, Young-Seok;Kwon, Hyung-Jin;Kim, Rock-Hee
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.21-26
    • /
    • 2008
  • Recently, small and medium-sized buildings have employed a multi-heat pump. The major benefits of the multi-heat pump over a conventional system are that it is easier system to maintain along with a diversification of facility use, and high comfortability. The performance of multi-heat pump systems can be enhanced by using geothermal energy instead of air source energy. This paper describes the multi-heat pumps applied in an ground source heat pump system for an actual building. The performance of a ground source multi-heat pump installed in the field was investigated in cooling mode. The maximum COP of the systems with single U-tube and double tube ground loop heat exchangers were 6.6 and 6.0, respectively. It is suggested that the new algorithms to control the flow rate of secondary fluid for ground loop heat exchanger have to be developed in order to enhance the performance of the system.

  • PDF

Facet Joint Syndrome (추간관절 증후군)

  • Kang, Jeom-Deok
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.15 no.2
    • /
    • pp.93-97
    • /
    • 2009
  • Anatomy: Facet joint syndrome most often affects the lower back and neck and refers to pain that occurs in the facet joints, which are the connections between the vertebrae in the spine that enable the spine to bend and twist. Many physicians have believed that the usual lesion of facet syndrome was an anatomical impairments of facet joint itself.. Facet joint injection using local anesthetics is a reliable method for the diagnosis and treatment for facet syndrome. Etiology: One of many possible causes is imbalances that can occur in stress levels, hormone levels, and nutritional levels. These imbalances can adversely affect posture, which can lead to neck and back pain. The common disorder called facet syndrome exhibits lower back pain, with or without, radiating pain to buttock and thigh due to facet joint arthropathy. Pain in the facet joint is supposedly the secondary effect of narrowing of joint space by sustained muscle contracture around joints. Syndrome: Facet joint syndrome tends to produce pain or tenderness in the lower back that increases with twisting or arching the body, as well as pain that moves to the buttocks or the back of the thighs. Other symptoms include stiffness or difficulty standing up straight or getting out of a chair. Pain can be felt in other areas such as the shoulders or mid-back area. Treatment: Non-drug treatments include hot packs, ultrasound, electrical stimulation, and therapeutic exercises. Stimulating blood flow using massage or a hot tub may also help. Alternative treatments include yoga and relaxation therapy. If your pain persists after trying these treatments, a surgical procedure called radiofrequency rhizotomy, which destroys the sensory nerves of the joint, may bring relief. Facet joint injection has been helpful in diagnosis and therapy for this facet syndrome. Radiofrequency thermocoagulation of medial branches is known to be an effective method of relieving pain caused by facet joint problems. We conclude that spasmolytic treatment of muscles connecting the two vertebral articular space would be better for treatment and diagnosis of facet syndrome rather than facet block with local anesthetic and steroid only.

  • PDF

System Performance Variation for Relative Location of Pre-swirl Nozzles and Receiver Holes in Radial On-Board Injection Type Pre-swirl System (반경방향 분사방식 프리스월 시스템의 프리스월 노즐과 리시버 홀의 상대적 위치에 따른 시스템 성능변화)

  • Lee, Jonggeon;Lee, Hyungyu;Cho, Geonhwan;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.1
    • /
    • pp.43-53
    • /
    • 2020
  • The effect of the relative location between pre-swirl nozzle and receiver hole on the performance of radial on-board injection type pre-swirl system was analyzed. In this study, tendency of the change of discharge coefficient and temperature drop efficiency were analyzed for 20 design points through the combination of 5 pre-swirl nozzle location and 4 receiver hole location. Discharge coefficient of system tended to be similar to the pressure ratio of the pre-swirl nozzle. System performance variation occurred as the flow structure in the cavity was affected by the surface, and the influence of the stationary surface is greater than that of the rotating surface. Discharge coefficient of system changed -1.39% to 1.25% and temperature drop efficiency changed -5.41% to 2.94% refer to reference design point.

Reconstruction of Disarticulated Knee Stump by Using Distally Based Anterolateral Thigh Island Flap (역혈류성 전외측대퇴섬피판을 이용한 무릎 잘린끝의 재건)

  • Kim, Hyoung Jin;Pyon, Jai Kyong;Burm, Jin Sik;Kim, Yang Woo
    • Archives of Plastic Surgery
    • /
    • v.34 no.4
    • /
    • pp.485-489
    • /
    • 2007
  • Purpose: The basic vascular anatomy and versatility of the anterolateral thigh flap was reported firstly by Song in 1984 and then by Zhang who introduced the reverse flow pattern of this flap. In this case, the authors reviewed various articles and their experiences with the distally based anterolateral thigh flap and applied it for coverage of bone-exposed wound occurred at the distal of the disarticulated knee stump. We consequently reported the reliability and resourcefulness of this flap in the difficult and limited situation. Methods: A 67-year-old-man who had suffered from arteriosclerotic obliterans inevitably underwent the disarticulation at knee joint due to clinical deterioration. He presented to our clinic with soft tissue necrosis and bone exposure at the stump. We debrided the wound and conducted the distally based anterolateral thigh island flap by transecting proximal portion of descending branch of the lateral circumflex femoral artery and the $14{\times}10cm$ sized flap was transferred to cover the defect. The pedicle measured 14 cm in length with pivot point 7 cm above the patella. Results: The postoperative course was mainly uneventful except early venous congestion for 4 days and subsequent partial skin loss. The wound was healed by secondary intension and no other sequelae had been observed during follow-up period of 12 months. Conclusion: Despite the presence of various reconstructive choices, the distally based anterolateral thigh island flap can be designed to repair soft tissue defects around the knee region, providing its reliable blood supply and long pedicle length, especially in the challenging cases.

Pulmonary artery rupture due to bacterial endocarditis complicated by patent ductus arteriosus. (동맥관개존증에 합병한 심내막염에 의한 폐동맥파열 실험 1례)

  • 조순걸
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.537-541
    • /
    • 1985
  • Recently, we met a 12 year old female patient who suffered from bacterial endocarditis and pericarditis which were complicated by patent ductus arteriosus. She was admitted to our hospital because of dyspnea, fever, headache, and generalized ache for 10 days. The initial diagnosis was bacterial endocarditis and pericarditis complicated by patent ductus arteriosus and congestive heart failure. At first, we tried to treat the patient medically with digitalis, diuretics, and massive antibiotics. On echocardiography large amount of pericardial fluid was accumulated mainly right anterior aspect and also noted a large vegetation at pulmonary valve area. With vigorous medical treatment including repeated pericardiocentesis, the patient showed no improvement. So we decided to perform pericardiectomy for elimination of the most probable septic focus. On operation, we encountered an unpredicted event, the pericardium was thickened, distended, and its surface showed pulsating which meant connecting to systemic circulation. We decided to close the operative wound and reoperate her under cardiopulmonary bypass later. On the next day, we operated her under cardiopulmonary bypass later. On the next day we operated her under cardiopulmonary bypass. The operative findings were ruptured main pulmonary artery about 1.5cm in diameter on its ventral portion, the blood from the ruptured main pulmonary artery was filled up the localized pericardial sac due to previous pericarditis. Through the ruptured main pulmonary artery, we also found 0.5cm diametered patent ductus arteriosus. With the aid of partial cardiopulmonary bypass and inserting 24F ballooned Foley catheter at aorta, pericardiectomy was performed first. After completion of the pericardiectomy, total cardiopulmonary bypass was established. With minimum pump flow [0.3L/min/m2] the PDA was closed with two Teflon-felted 4-0 Prolene interrupted sutures. The ruptured main pulmonary artery was also closed using thickened pericardium with three Teflon-felted 4-0 Prolene interrupted sutures. The operation was successful and postoperative course was uneventful. She was discharged on the 16th POD. We report this case as a very rare secondary complication of bacterial endocarditis complicated by patent ductus arteriosus.

  • PDF

The Fabrication of Ion Exchange Membrane and Its Application to Energy Systems (고분자 이온교환막의 제조와 이온교환막을 이용한 에너지 공정)

  • Kim, Jae-Hun;Ryu, Seungbo;Moon, Seung-Hyeon
    • Membrane Journal
    • /
    • v.30 no.2
    • /
    • pp.79-96
    • /
    • 2020
  • Secondary energy conversion systems have been briskly developed owing to environmental issue and problems of fossil fuel. They are basically operated based on electro-chemical systems. In addition, ion exchange membranes are one of the significant factors to determine performance in their systems. Therefore, the ion exchange membranes in suitable conditions must be developed to improve the performance for the electro-chemical systems. These ion exchange membranes can be classified into various types such as cation exchange membrane, anion exchange membrane and bipolar membrane. Their membranes have distinct characteristics according to the chemical, physical and morphological structure. In this review, the types of ion exchange membranes and their fabrication processes are described with main characteristics. Moreover, applications of ion exchange membranes in newly developed energy conversion systems such as reverse electrodialysis, redox flow battery and water electrolysis process are described including their roles and requirements.

Scale Thickness Measurement of Steam Generator Tubing Using Eddy Current Signal of Bobbin Coil (보빈코일 와전류신호를 이용한 증기발생기 세관 스케일 두께 측정)

  • Kim, Chang-Soo;Um, Ki-Soo;Kim, Jae-Dong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.545-550
    • /
    • 2012
  • Steam generator is one of the major components of nuclear power plant and steam generator tubes are the pressure boundary between primary and secondary side, which makes them critical for nuclear safety. As the operating time of nuclear power plant increases, not only damage mechanisms but also scaled deposits on steam generator tubes are known to be problematic causing tube support flow hole blockage and heat fouling. The ability to assess the extent and location of scaled deposits on tubes became essential for management and maintenance of steam generator and eddy current bobbin data can be utilized to measure thickness of scale on tubes. In this paper, tube reference standards with various thickness of scaled deposit has been set up to provide information about the overall deposit condition of steam generator tubes, providing essential tool for steam generator management and maintenance to predict and prevent future damages. Also, methodology to automatically measure scale thickness on tubes has been developed and applied to field data to estimate overall scale amount.

A Study in order to Utilize Waste Glasses Powder as Admixtures of Self-Compacting Concrete (폐유리(廢琉璃) 미분용(微粉用)을 보수용(補修用) 모르타르 및 자기충전(自己充塡)콘크리트의 혼화재료(混和材料)로 활용(活用)하기 위한 연구(硏究))

  • Choi, Yun-Wang;Jung, Jea-Gwone;Kang, Hyun-Jin
    • Resources Recycling
    • /
    • v.17 no.1
    • /
    • pp.29-37
    • /
    • 2008
  • Recently, domestically and internationally, the occurrences of Waste Glass are on the increase. Most of scrap glass are either reused of recycled. However, glass not recycled is buriedand is causing secondary environmental problem. With 5% mixture of Waste Glass, the average paste viscosity (rheology) decreased by 22.3% and 28-day compressive strength of mortar's flow and aging decreased by 1.5% and 6% respectively. Also, as Waste Glass mixture ratio of un-hardened elf-compacting concrete increased, fluidity increased and compressive strength decreased. In consideration of adequate compressive strength and fluidity that meets the 2nd class JSCE regulations; optimum mixture ratio of Waste Glass can be concluded as 20%.

Brief Review on Microbial Enhanced Oil Recovery (미생물을 이용한 원유 회수증진법에 대한 동향연구)

  • Oh, Kyeongseok
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.4
    • /
    • pp.1010-1019
    • /
    • 2021
  • Petroleum oil in reservoir has been acquired by primary, secondary and tertiary oil recoveries. Microbial enhanced oil recovery (MEOR) classified to tertiary oil recovery has been evaluated in two ways of in-situ and ex-situ options. In-situ MEOR injects microbes into a depleted oil reservoir and stimulates those to generate metabolites. Among metabolites, biosurfactants play an important role to make heavy residues flow. Ex-situ MEOR injects microbial metabolites instead of microbes into a reservoir to recover oil. Even though both in-situ MEOR and ex-situ MEOR are eco-friend processes, in-situ MEOR can be preferred because it is more economic. Even though MEOR have been evaluated for a long time, it is still in the state of evaluating in a pilot-scale. Among microbes, bacteria have been widely evaluated in MEOR purpose. In this paper, bacteria for MEOR were summarized and their metabolites were qualitatively evaluated.