• Title/Summary/Keyword: secondary device

Search Result 350, Processing Time 0.026 seconds

Analysis of Harmonics generated at Load of Adjustable Speed Drives (가변속 구동장치의 부하측에서 발생하는 고조파 해석)

  • Kim, Jong-Gyeum;Lee, Eun-Woong;Lee, Dong-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.46-48
    • /
    • 1997
  • Induction motor control using for adjustable speed drives has caused secondary effect such as harmonics. Therefore it is considered a various countermeasures to minimize these effects. In this paper, we analyzed the influence of harmonics that is generated by the inverter device for adjustable speed drive of induction motor at the load side.

  • PDF

Graphene Anode Material Technology Patent Trend Analysis for Secondary Battery (이차전지용 그래핀 음극소재 기술 특허 동향 분석)

  • Jae Eun Shin;Junhee Bae
    • Economic and Environmental Geology
    • /
    • v.55 no.6
    • /
    • pp.661-669
    • /
    • 2022
  • The need for miniaturization, high efficiency, and green energy resources as an energy storage device through the development of various electronic device has emerged. Accordingly, nanomaterials with excellent electrochemical properties, such as graphene and graphene hybrids, are attracting attention as promising materials. In particular, in the electric vehicle industry, cost reduction of secondary batteries is a key factor that can determine the spread of related industries, and it is most important to analyze R&D trends for battery material technology and respond to future technological development directions. Therefore, in this study, we tried to suggest a direction for R&D activities in the future by analyzing patent trends for graphene anode material technology for secondary batteries and deriving implications. As a result, in the case of anode material technology, the proportion of foreigners in the US and European patent markets was higher than in the Korean and Japanese patent markets, which means that the US and European marketability is high. In addition, Japanese applicants are filing high-level applications not only in the Japanese patent market but also in other countries suggests that Japan is leading the technology in this field. Lastly, the proportion of research institutes in the patent market of Korea and the US remains high compared to that of Japan and Europe, indicating that the commercialization of technology is still slow in those countries. Therefore research institutes and companies in Korea will have to establish their own strategies for developing and securing materials using the results of patent trends in major countries and major companies analyzed in this study.

Study for Semi-Steering system for Urban Maglev (도시형자기부상차량의 반능동 조향장치에 대한 연구)

  • Lee, Nam-Jin;Kang, Kwang-Ho;Lee, Won-Sang
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1080-1084
    • /
    • 2011
  • Urban maglev should have such characteristics as not only environmentally friendliness and excellent driving capability but also curve negotiation performance because its routes have many sharp curves. Due to normal mechanism of urban maglev its relative displacements of secondary spring are bigger than conventional railway vehicle and the centering force of levitation magnet is smaller than wheel-on-rail system. These features of maglev affect the curving negotiation and so the additional steering device is to be required on Urban maglev to improve the running performance at sharp curve of less than about R50m. Some developed urban maglev had the passive steering device which consists of mechanical linkage or hydraulic cylinder and closed-route piping. But it has drawback as complexity of layout of understructure of vehicle and functional limitation of passive mechanism regarding transient curve. These demerits could be solved by using active steering system. But it has a weak point that an active device should have actuators and additional inverter or hydraulic power source. In this paper, the semi-active steering system for urban maglev is to be introduced.

  • PDF

Detection of Influenza A Virus by Interdigitated Nanogap Devices

  • Park, Jimin;Park, Dae Keun;Lee, Cho Yeon;Kang, Aeyeon;Yun, Wan Soo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.419-419
    • /
    • 2014
  • Interdigitated nanogap device (IND) is an attractive tool for biomolecular detection due to its huge on-off signal ratio, great tolerance to the variation in biochemical environment, and relatively simple implementation processes. Here, we report on the IND-based detection of Influneza A virus by sandwich immunoassay. The INEs were fabricated by photo lithography followed by the in-house chemical lithographic technique for the narrowing the initial gap distance. The surface of the silicon oxide between the two gold electrodes was chemically modified to immobilize primary antibodies for the immuno-specific interaction with the influenza A virus antigen. After immersing the functionalized-IND into the sample solution containing the influenza A virus, the device was exposed to the secondary antibody conjugated Au nanoparticles (Au NPs). The INDs showed a huge jump in the electric conductance when the sample solution contained the influenza A virus of the concentration as low as 10 ng/mL. We hope that this IND-based sensing can be applied to the development of simple and reliable diagnostic means of influenza viruses.

  • PDF

Emission Characteristics of Power Type Electroluminescent Device (분산형 전계발광 소자의 발광 특성)

  • 권순석;임기조;박수길;김현후;류부형;김용주
    • Electrical & Electronic Materials
    • /
    • v.10 no.2
    • /
    • pp.150-155
    • /
    • 1997
  • Powder type electroluminescent device(P-ELD) in this study was prepared by printing method. P-ELDs were basically composed of phosphor, insulator and transparent conducting layer. The phosphor powder was prepared by sintering the mixture of ZnS as a host, Cu as an activator, and NaCl as a flux for co-activator and enhancement of growth of the phosphor particles. The phosphor layer was made by printing the paste of the cyanoethylpullan as a binder and the ZnS system phosphor powder. In order to evaluate the luminescence characteristics of ZnS P-ELD, applied voltage - luminance(V-L), frequency-luminance(f-L), and relative luminance spectra(L- .lambda.) characteristics were measured. The experimental results show that luminance increased with increasing the applied voltage and frequency. It can be explained in terms of the potential barrier formed between ZnS and CuS. Two emission peaks in luminance-wavelength spectra measured at applied voltage of 100 $V_{rms}$ were observed at 500nm as a primary peak and 460nm as a secondary peak, respectively.y.

  • PDF

A Study on the Performance Evaluation of Portable Radiation Shielding Apparatus (이동형 방사선 차폐장치의 성능평가에 관한 연구)

  • Koo, Bon-Yeoul;Han, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.41 no.4
    • /
    • pp.289-295
    • /
    • 2018
  • When using a mobile X-ray unit, primary radiation creates medical images and secondary radiation scatters in many directions, which reduces image quality and causes exposure to patients, care givers and medical personnel. The purpose of this study was to develop a radiation shielding system for effectively shielding secondary radiation and evaluate its effectiveness. Using a mobile X-ray unit, spatial dose according to presence of human equivalent phantom and spatial dose using the developed shielding device were measured, and the phantom at 80 cm equidistance from center of X-ray was compared with spatial dose according to use of a shield. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from the head direction($-90^{\circ}$) to the body direction($+90^{\circ}$). In the spatial dose measurement with and without the phantom, when the human equivalent Phantom was used, the spatial dose was increased by 40% in all directions from 40 cm to 100 cm from the central X-ray, and about 88% of the space dose was reduced when using the developed shields with the phantom. The equidistance dose at 80 cm from the central X-ray was increased by 39% from $5.1{\pm}0.26{\mu}Gy$ to $7.1{\pm}0.15{\mu}Gy$ when the human equivalent phantom was used, and when phantom was used and shielding was used, the spatial dose was reduced by about 90% from $7.1{\pm}0.15{\mu}Gy$ to $0.7{\pm}0.07{\mu}Gy$. The spatial dose of natural radiation was measured to be about $0.2{\pm}0.04{\mu}Gy$ when using the developed shielding with Phantom at a distance of 1 m or more. It is expected that by using the developed shielding system, it will be possible to effectively reduce secondary radiation dose received in all directions and to ensure safe imaging.

Development of Radiation Restrictor for Secondary Radiation Shielding of Mobile X-ray Generator (이동형 X선 발생장치의 2차 방사선 차폐를 위한 선속조절기 개발 연구)

  • Koo, Bon-Yeoul;Kim, Gha-Jung
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.397-403
    • /
    • 2018
  • Mobile X-ray generators are used not in the radiation area but in open space, which causes the exposure of secondary radiation to the healthcare professionals, patients, guardians, etc., regardless of their intentions. This study aimed to investigate the shielding effect of the developed radiation restrictor to block the secondary radiation scattered during the use of mobile X-ray generator. Upon setting the condition of mobile X-ray generator with chest AP, spatial doses were measured by the existence of human equivalent phantom and radiation restrictor, and measured by the existences of phantom and radiation restrictor at the same length of 100 cm. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from $-90^{\circ}$ (head direction) to $+90^{\circ}$ (body direction). Upon the study results, spatial doses in all direction were increased by 45% on average when using phantom in the same condition, however, they were decreased by 64% on average when using the developed radiation restrictor. The dose at 100 cm from the center of X-ray was $3.0{\pm}0.08{\mu}Gy$ without phantom and was increased by 40% with $4.2{\pm}0.08{\mu}Gy$ after phantom usage. The dose when using phantom and the developed radiation restrictor was $1.4{\pm}0.08{\mu}Gy$, which was decreased by 66% compared to the case without using them. Therefore, it is considered the scattered radiation can be shielded at 100-150 cm, the regulation of the distance between beds, effectively with the developed radiation restrictor when using mobile X-ray generators, which can lower the radiation exposure to the people nearby including healthcare professionals and patients.

Numerical Study on a Hydrogen Recirculation Ejector for Fuel Cell Vehicle (연료전지 수소재순환 이젝터 시스템에 관한 수치해석적 연구)

  • NamKoung, Hyuck-Joon;Moon, Jong-Hoon;Jang, Seock-Young;Hong, Chang-Oug;Lee, Kyoung-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.156-160
    • /
    • 2007
  • Ejector system is a device to transport a low-pressure secondary flow by using a high-pressure primary flow. Ejector system is, in general, composed of a primary nozzle, a mixing section, a casing part for suction of secondary flow and a diffuser. It can induce the secondary flow or affect the secondary chamber pressure by both shear stress and pressure drop which are generated in the primary jet boundary. Ejector system is simple in construction and has no moving parts, so it can not only compress and transport a massive capacity of fluid without trouble, but also has little need for maintenance. Ejectors are widely used in a range of applications such as a turbine-based combined-cycle propulsion system and a high altitude test facility for rocket engine, pressure recovery system, desalination plant and ejector ramjet etc. The primary interest of this study is to set up an applicable model and operating conditions for an ejector in the condition of sonic and subsonic, which can be extended to the hydrogen fuel cell vehicle. Experimental and theoretical investigation on the sonic and subsonic ejectors with a converging-diverging diffuser was carried out. Optimization technique and numerical simulation was adopted for an optimal geometry design and satisfying the required performance at design point of ejector for hydrogen recirculation. Also, some sonic and subsonic ejectors with the function of changing nozzle position were manufactured precisely and tested for the comparison with the calculation results.

  • PDF

Performance Analysis on a Hydrogen Recirculation Ejector for Fuel Cell Vehicle (연료전지 수소재순환 이젝터 성능 해석)

  • NamKoung, Hyuck-Joon;Moon, Jong-Hoon;Jang, Seock-Young;Hong, Chang-Oug;Lee, Kyoung-Hoon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.256-259
    • /
    • 2008
  • Ejector system is a device to transport a low-pressure secondary flow by using a high-pressure primary flow. Ejector system is, in general, composed of a primary nozzle, a mixing section, a casing part for suction of secondary flow and a diffuser. It can induce the secondary flow or affect the secondary chamber pressure by both shear stress and pressure drop which are generated in the primary jet boundary. Ejector system is simple in construction and has no moving parts, so it can not only compress and transport a massive capacity of fluid without trouble, but also has little need for maintenance. Ejectors are widely used in a range of applications such as a turbine-based combined-cycle propulsion system and a high altitude test facility for rocket engine, pressure recovery system, desalination plant and ejector ramjet etc. The primary interest of this study is to set up an applicable model and operating conditions for an ejector in the condition of sonic and subsonic, which can be extended to the hydrogen fuel cell vehicle. Experimental and theoretical investigation on the sonic and subsonic ejectors with a converging-diverging diffuser was carried out. Optimization technique and numerical simulation was adopted for an optimal geometry design and satisfying the required performance at design point of ejector for hydrogen recirculation. Also, some ejectors with a various of nozzle throat and mixing chamber diameter were manufactured precisely and tested for the comparison with the calculation results.

  • PDF

Urosepsis and postrenal acute renal failure in a neonate following circumcision with Plastibell device

  • Kalyanaraman, Meena;McQueen, Derrick;Sykes, Joseph;Phatak, Tej;Malik, Farhaan;Raghava, Preethi S.
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.4
    • /
    • pp.154-157
    • /
    • 2015
  • Plastibell is one of the three most common devices used for neonatal circumcision in the United States, with a complication rate as low as 1.8%. The Plastibell circumcision device is commonly used under local anesthesia for religious circumcision in male neonates, because of cosmetic reasons and ease of use. Occasionally, instead of falling off, the device may get buried under the skin along the shaft of the penis, thereby obstructing the normal flow of urine. Furthermore, the foreskin of neonates is highly vascularized, and hence, hemorrhage and infection are possible when the skin is cut. Necrosis of penile skin, followed by urethral obstruction and renal failure, is a serious surgical mishap requiring immediate corrective surgery and medical attention. We report a case of fulminant urosepsis, acute renal failure, and pyelonephritis in a 4-day-old male neonate secondary to impaction of a Plastibell circumcision device. Immediate medical management was initiated with fluid resuscitation and mechanical ventilation; thereby correcting life threatening complications. Pediatricians and Emergency Department physicians should be cognizant of the complications from Plastibell circumcision device in order to institute appropriate and timely management in neonates.