• 제목/요약/키워드: secondary currents

검색결과 143건 처리시간 0.032초

2차 전압-철손 전류 곡선과 자속-자화 전류 곡선을 고려한 측정용 변류기 2차 전류 보상 알고리즘 (Compensating algorithm for the secondary current of a measurement type CT considering the secondary voltage-core loss current curve and the flux linkage-magnetizing current curve)

  • 강용철;정태영;장성일;김용균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.65-66
    • /
    • 2008
  • This paper proposes a compensating algorithm for the secondary current of the measurement current transformer (CT) that removes the effects of the hysteresis characteristics of the iron-core. The exciting current resulting from the hysteresis characteristics of the core causes an error between the primary current and the secondary current of the CT. The proposed algorithm decomposes the exciting current into the magnetizing current and the core loss current and each of them is estimated. The core loss current is calculated from the secondary voltage and the secondary voltage-core loss current curve. The core flux linkage is calculated and then inserted into the flux-current curve to estimate the magnetizing current. The exciting current at every sampling interval is obtained by summing the core-loss and magnetizing currents and then added to the measured current to compensate the secondary current. The performance of the proposed algorithm is validated under various conditions using EMTP generated data. The test results of the real CT were also included. The results indicate that the proposed algorithm can improve the accuracy of the measurement CT significantly, and thus reduce the size and the cost of the CT.

  • PDF

2차 권선의 연결방법에 따른 변압기형 초전도 한류기의 특성 (Characteristics of Transformer-Type SFCL according to the Connecting Methods of Secondary Coils)

  • 조용선;박형민;정수복;최효상
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2078-2083
    • /
    • 2007
  • We have analyzed operating characteristics of transformer-type superconducting fault current limiter (SFCL) according to the serial or parallel connections of secondary coils with $YBa_2Cu_3O_7$ (YBCO) thin films. The turn ratio between the primary and secondary coils was 63:21. Transformer-type SFCL using a transformer with secondary winding of serial or parallel coils could reduce the unbalanced quench caused by differences of the critical current density between YBCO thin films. We found that transformer-type SFCL having serial or parallel connections induced simultaneous quench between the superconducting units. The limiting current in the transformer-type SFCL with a parallel connection was lowered to 30 % compared to the SFCL with a serial connection. In the meantime, when the currents generated in the superconducting units were similar, the voltage value in the parallel connection was 60 % as low as that in the serial connection. However, the voltage generated in the primary winding was some higher. In conclusion, we found that transformer-type SFCL with parallel connection of secondary coils was more effective in fault current limiting characteristics and in the reduction of the consumption power for superconducting units compared to those of the transformer-type SFCL with serial connection of secondary coils.

중등학교 과학교과서의 황해 및 동중국해 해류도 분석 (An Analysis of Oceanic Current Maps of the Yellow Sea and the East China Sea in Secondary School Science Textbooks)

  • 박경애;박지은;최병주;이상호;이은일;변도성;김영택
    • 한국지구과학회지
    • /
    • 제35권6호
    • /
    • pp.439-466
    • /
    • 2014
  • 다양한 중등학교 과학교과서 동해 해류도의 통일이 최근에 완성됨에 따라 황해와 동중국해의 해류도 제작에 대한 요구가 증대되고 있다. 이 연구는 그 첫 단계로서 과학 논문과 2014년 현행 교과서의 해류도들을 분석하여 향후 황해와 동중국해의 통일된 해류도를 제작하는 과정을 촉진시키고자 하였다. 우선 교과서와 과학 논문의 아날로그 해류도들을 수치화하여 해류도의 특성을 정량적으로 조사하였고 해류도들을 상호 비교하였다. 쿠로시오해류, 대만난류, 대마난류, 황해난류, 중국연안류, 한국연안류, 양쯔강 유출류와 같이 황해와 동중국해의 해류들을 선정하고 정의하였다. 이 해류들의 경로를 조사하기 위하여 18개의 세부 항목을 만들고 이를 분석에 활용하였다. 각 세부항목에 대하여 교과서와 과학 논문 해류도들을 분석한 결과, 교과서 해류도들은 과학 논문으로부터 획득한 해류에 관한 최근의 지식과 상당한 차이를 나타내었다. 또한 황해와 동중국해 해류는 계절에 따라 크게 변화하므로 해류 전문가들의 활발한 토의를 통하여 교과서 해류도를 적어도 여름철과 겨울철로 구분하여 제시해야 할 것이다.

중등학교 교과서 황해난류 오개념 분석 및 해류 데이터 시각화 수업자료 개발 (Misconception on the Yellow Sea Warm Current in Secondary-School Textbooks and Development of Teaching Materials for Ocean Current Data Visualization)

  • 김수란;박경애;변도성;정광영;최병주
    • 한국지구과학회지
    • /
    • 제44권1호
    • /
    • pp.13-35
    • /
    • 2023
  • 지구의 기후 변화를 유도하고 제어하는 가장 중요한 역할을 하는 것은 해양의 해류이다. 황해는 수심이 동해에 비해 매우 얕고, 다양한 바람과 조류, 강물의 유입, 동중국해에서의 해수 유입 등 외력의 영향으로 해수의 순환과 해류가 상당히 복잡하다. 황해난류는 겨울철 황해의 대표적인 해류로서 겨울철 황해와 동중국해 바람 변동성과 밀접한 관련이 있으며, 황해의 수온과 염분 분포에 큰 영향을 주어서 중등학교 교과서에서 중요하게 다루어질 필요성이 있다. 2015 개정 교육과정 기반 중등학교 과학 및 지구과학 교과서의 황해난류와 관련된 내용을 분석하였다. 또한 해류의 시간 변동성에 대한 교사들의 인식을 조사하기 위해 중등학교 과학 교사들을 대상으로 설문조사를 실시하였다. 대부분의 교사들은 황해난류가 우리나라 서해안으로 연중 북상하고 있으며 일반적인 난류와 같이 여름철에 강하다는 잘못된 지식을 가지고 있는 것으로 나타났다. 황해난류는 해류의 세기가 강한 계절변동성을 가지는 북한한류와 달리 해류 자체가 연중 항시 존재하지 않으며 겨울철에만 발생하는 해류이다. 이러한 교사들의 교과내용 지식에 대한 오류는 북한한류가 겨울철에 강하다는 오개념을 가지게 된 연유와 유사한 배경을 가지고 있었다. 따라서 본 연구에서는 황해난류에 대한 교과서 내용의 오류를 분석하여 제시하였다. 또한 학생들과 교사들의 데이터 리터러시 함양을 위하여 탐구활동에서 활용할 수 있는 황해난류에 대한 수업 자료를 개발하였다. 황해 해수면 온도를 가시화할 수 있는 GUI 프로그램을 소개하였고, WOA (World Ocean Atlas) 2018 해양 실측 수온 및 염분자료와 국립해양조사원에서 생성한 해양 수치모델 재분석자료를 활용하여 수온과 염분의 공간 분포를 도시하는 자료를 개발하여 제시하였다. 이러한 해양 자료를 활용한 데이터 시각화과정은 교사들의 오개념을 개선하고, 나아가 학생들과 교사들의 해양 리터러시뿐만 아니라 데이터 리터러시도 제고하는 계기가 될 것으로 기대된다.

새로운 변압기 보호용 디지털 계전 알고리즘 (A New Digital Relaying Algorithm for Transformer Protection)

  • 강용철;이병은;손진만;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.194-196
    • /
    • 2000
  • This paper presents a new digital relaying algorithm for protection of a two winding power transformer. The proposed algorithm calculates mutual flux linkages of primary and secondary windings from the currents and voltages of primary and secondary windings. The mutual flux linkage ratio of primary and secondary windings is equal to the turn ratio in case of the steady state and magnetic inrush. On the other hand, the ratio is different from the turn ratio in case of internal winding faults. The algorithm does not require B-H curve. The results of various tests are satisfactory.

  • PDF

유기전압비를 이용한 변압기 보호계전 알고리즘 (A Transformer Protective Relaying Algorithm Using the Ratio of Induced Voltages)

  • 강용철;이병은
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권10호
    • /
    • pp.524-530
    • /
    • 2000
  • This paper presents a transformer protective relaying algorithm using the ratio of induced voltages. The proposed algorithm calculates primary and secondary voltage from currents and voltages of primary and secondary windings. The ratio of primary and secondary induced voltages is equal to the turn ratio in case of the steady state and magnetic inrush. On the other hand, the ratio is different form the turn ratio in case of internal winding faults. The algorithm does not require B-H curve and can reduce the relay's operating time.

  • PDF

사행수로에서 흐름 특성에 관한 실험적 연구 (Experimental Study on Flow Characteristics in Meandering Channel)

  • 서일원;성기훈;백경오;정성진
    • 한국수자원학회논문집
    • /
    • 제37권7호
    • /
    • pp.527-540
    • /
    • 2004
  • 다중 만곡부에서의 주흐름과 이차류의 흐름 특성을 분석하기 위하여 중심각 120$^{\circ}$인 두 개의 만곡부로 이루어진 사행수로에서 실험을 수행하였다. 실험수로의 횡단면은 직사각형과 곡선형 두 가지 형태로 제작하였으며, 곡선형 단면 형상 결정에는 베타함수를 이용하였다. 3차원 유속장의 측정은 micro-ADV를 이용하였다. 실험결과, 직사각형 수로에서 주흐름은 수로의 가장 짧은 경로를 따라 발생하였으며, 이는 기존 연구자들의 결과와 일치한다. 곡선형 수로에서도 주흐름이 직사각형 수로에서의 주흐름의 거동과 비슷한 양상을 보이는 것으로 밝혀졌다. 곡선형 수로에서의 실험결과가 실제 자연하천의 만곡부에서의 주흐름 거동(최심선을 따라 발생)과 상이하게 나타나는 이유는 실험수로의 바닥 조도와 사행도에 기인한 것으로 사료된다. 이차류의 정량적인 분석을 위하여 흐름함수를 도입한 결과, 만곡부에서 주 셀 뿐만 아니라 바깥제방 셀의 위치 및 형태를 확인할 수 있었다. 또한 이차류 강도를 계산한 결과, 직사각형 및 곡선형 수로에서 최대값은 두 번째 만곡부의 정점 부근에서 가장 크게 나타나며 곡선형 수로의 이차류의 강도가 직사각형 수로의 값보다 크게 나타나고 있음을 알 수 있었다. 직사각형 수로의 경우, 하폭 대 수심비가 커질수록 이차류의 강도가 증가하고 있음을 확인하였다.

히스테리시스 특성을 고려한 측정용 변류기 2차 전류 보상 알고리즘 (Compensating Algorithm for the Secondary Current of a Measurement CT Considering the Hysteresis Characteristics of the Core)

  • 강용철;정태영;장성일;김용균;소순홍
    • 전기학회논문지
    • /
    • 제56권10호
    • /
    • pp.1709-1714
    • /
    • 2007
  • This paper proposes a compensating algorithm for the secondary current of the measurement current transformer (CT) that removes the effects of the hysteresis characteristics of the iron-core. The exciting current resulting from the hysteresis characteristics of the core causes an error between the primary current and the secondary current of the measurement CT. The exciting current can be decomposed into the magnetizing current and the core loss current. The core loss current is obtained from the measured secondary current and the core loss resistance. The core flux linkage is calculated by integrating the measured secondary current, and then inserted into the flux-magnetizing current curve to obtain the magnetizing current. The exciting current at every sampling interval is obtained by summing the core-loss and magnetizing currents and then added to the measured current to obtain the correct current. The performance of the proposed algorithm is validated under various conditions using EMTP generated data. The results indicate that the proposed algorithm can improve the accuracy of the measurement CT significantly, and thus reduce the size and the cost of the measurement CT.

Comparison of Flywheel Systems for Harmonic Compensation Based on Wound/Squirrel-Cage Rotor Type Induction Motors

  • Kim, Yoon-Ho;Jeong, Yeon-Suk;Jeong, Yeon-Suk
    • Journal of Power Electronics
    • /
    • 제1권2호
    • /
    • pp.127-132
    • /
    • 2001
  • This paper describes two different systems which can compensate harmonic currents generated in a power system. As non-linear loads increase gradually in industry fields, harmonic current generated in the electric power network system also increases. Harmonic current makes a power network current distorted and generates heat, vibration and noise in the power machinery. Many approaches have been applied to compensate harmonic currents generated in the power system. Among various approaches, in this paper, two kinds are compared and evaluated. They are flywheel compensators bases on secondary excitation of WRIM(wounded rotor induction motor) and SCIM(squirrel cage induction motor). Both systems have a common structure. They use a flywheel as an energy storage device and use PWM inverters. The main differences are the size and rating of the converter used.

  • PDF