Measurement and Control of the Resonance Frequency for the Transcutaneous Energy Transmission System (TET) Using the Phase Locked Loop Circuit (PLL) (PLL을 이용한 무선 전력전송 장치의 공진 주파수의 계측 및 주파수 제어)

  • Choi, S.W.;Shim, E.B.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1613-1616
    • /
    • 2008
  • A Transcutaneous Energy Transmission System (TET) has been developed for the wireless energy transmission with two magnetically coupled coils. A resonance circuit is used to raise the induced voltage and current of the secondary coil. Its resonance frequency depends on the internal resistance of circuit and the transferred energy. Because the transferred energy usually changes in wide range, the output voltage is unstable and the energy transferring efficiency decrease. A push-pull class E amplifier is usedto generate high frequency AC voltage. To maintain proper resonance frequency, the voltage output of the amplifier was continuously monitored and adjusted to the optimized resonance frequency. Because of its high frequency (370 kHz), a phase lockedloop circuit and a comparator are used to monitor the output waveform. The results of experimentaldata show that the PLL circuit can increase the transmission efficiency and stabilize the output voltage of TET.

  • PDF

High Density On-Board DC/DC Converter Using Multi-Layer PCB (다층 PCB를 이용한 고밀도 On-Board DC/DC Converter)

  • Kim Y.P.;Kim T.S.;Lim B.S.;Kim H.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.781-784
    • /
    • 2003
  • In this paper, high density on-board dc/dc converter using multi-layer PCB is proposed. Recently, the communication system wants power supply of open-frame, high density and low profile. So experimental converter was consisted of 3.3V/30A Quarter Brick size DC/DC Converter. To power height limit, coil of transformer, choke and circuits were consisted of multi layer PCB. Besides to improve of efficiency, made secondary synchronous rectifier Mosfet driving circuit. So total efficiency could be improved.

  • PDF

POWER TRANSMISSION CHARACTERISTICS OF FEASIBLE NON-CONTACT PICK-UP COIL COUPLED TO HIGH-FREQUENCY POWER SUPPLY SYSTEM

  • Kuroda, Mitsuyoshi;Tsuda, Masanori;Okuno, Atsushi;Gamage, Laknath;Mutsuo, Nakaoka
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.447-451
    • /
    • 1998
  • This paper conducts a study on a non-contact power delivering system using high-frequency inverter with the purpose of discussing the non-contact electric power transmission characteristics through circuit analysis, magnetic analysis and feasible experiments. In this power delivering scheme, various properties pertaining to the non-contact transformer of the power system such as the design, the core depth, core material, primary side frequency etc. are considered with a view of improving the non-contact power dilivery to the secondary.

  • PDF

Fabrication and Characteristics of Transformers for High Power Density SMPS (고밀도 SMPS 용 변압기의 제조와 특성)

  • Kim, Hyun-Sik;Kim, Jong-Ryung;Huh, Jung-Sub;Oh, Yong-Woo;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.7-10
    • /
    • 2002
  • We designed the flyback planar transformer, which had 8W capacity, with 70V input voltage and 8.2V output voltage for the establishment of design method and the confirmation of application possibility. The numerical value of inductance measured under the switching frequency of 120 kHz was 1650 ${\mu}H$, which was the inductance efficiency of 85~87% against theoretical value. The A.C. resistance of primary and secondary coil was 4.2 ${\Omega}$ and 0.25 ${\Omega}$ respectively. On the other hand, the quality factor for each wound numbers showed quite a high value of 158 and 75 respectively. And the Coupling Factor was 0.96~0.97 under 120 kHz switching frequency. And the shape of the output wave of the planar transformer at 70V input voltage was a stable square wave.

  • PDF

Effect of Metal Oxide on the Superconductivity of YBCO

  • Lee, Sang-Heon
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1241-1242
    • /
    • 2006
  • Electromagnetic properties of $CeO_2$ doped and undoped YBaCuO superconductors were evaluated to investigate the effect of pinning center on the magnetization and magnetic shielding. The variation $\DeltaM$ with doping was maximum for 3% doping and decrease with further doping. The magnetic shielding was evaluated by measuring the induced voltage in secondary coil and the voltage initially set to 0.5V, decreased to 0.17V and 0.28V respectively for the undoped and 3% $CeO_2$ doped sample. The much less change in the induced voltage for the 3% doped sample is attributed to the increased flux shielding by shielding vortex current. The $CeO_2$ was converted to fine $BaCeO_3$ particles which were trapped in YBaCuO superconductor during the reaction sintering. The trapped fine particles, $BaCeO_3$ may be acted as a flux pinning center.

  • PDF

The modeling of the IPT system used for PRT (Personal Rapid Transmit) (소형궤도 차량용 유도전력급전 계통 모델링)

  • Lee Byung-Song;Bae Chang-Han;Byun Yeun-Sub;Han Kyung-Hee
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1413-1418
    • /
    • 2004
  • This paper shows the analysis of the inductive power transfer system in conjunction with series resonant converter operating variable high frequency. Of particular interest is the sensitivity of the complete system to variations in operational frequency and parameters. In inductive power transfer system, electrical power is transferred from a primary winding in the form of a coil or track, to one or more isolated pick-up coils that may relative to the primary. The ability to transmit power without contact enables high reliability and easy maintenance that allows inductive power transfer system to be implemented in hostile environments. This technology has found application in many fields such as electric vehicles, PRT(Personal Rapid Transit) etc. The coupling between the primary and secondary is then presented to include the effects of parameter and operational frequency variation.

  • PDF

The Characteristic analysis of the IPT system used for PRT(Personal Rapid Transmit) (소형궤도차량 유도전력급전 계통 특성해석)

  • Lee, B.S.;Kim, Do-Won;Han, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.218-220
    • /
    • 2005
  • This paper shows the analysis of the inductive power transfer system in conjunction with series resonant converter operating variable high frequency. Of particular interest is the sensitivity of the complete system to variations in operational frequency and parameters. In inductive power transfer system, electrical power is transferred from a prima교 winding in the form of a coil or track, to one or more isolated pick-up coils that may relative to the primary. The ability to transmit power without contact enables high reliability and easy maintenance that allows inductive power transfer system to be implemented in hostile environments. This technology has found application in many fields such as electric vehicles, PRT(Personal Rapid Transit) etc. The coupling between the primary and secondary is then presented to include the effects of parameter and operational frequency variation.

  • PDF

A study on the testing methods of air spring for railway rolling stock (철도차량용 공기스프링 시험방법 규격안에 대한 연구)

  • Hur Hyun-Moo;Kwon Sung-Tae;Choi Kyung-Jin;Kim Wan-Doo
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.339-344
    • /
    • 2003
  • Air spring for railway rolling stock is a part of secondary suspension system, which is supporting load, damping vibration. Recently, air springs are actively applied to railway rolling stock to substitute the coil spring by upgrading the manufacturing skill. This study is started to develop draft for the testing methods of air spring for railway rolling stock. We have tested several items on testing methods to guarantee the performance of air spring. Thus, we have developed the test draft for air spring.

  • PDF

Effect of Residual Lithium Ions on the Structure and Cytotoxicity of Silk Fibroin Film

  • Yang, Yesol;Kwak, Hyo Won;Lee, Ki Hoon
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.27 no.2
    • /
    • pp.265-270
    • /
    • 2013
  • Dialysis is the rate-limiting step in the preparation of aqueous silk fibroin (SF) solution. However, the traditional practice of dialyzing SF solution for at least 48 h to remove LiBr is not based on empirical evidence. The aim of the present study was to systematically measure LiBr content in SF solutions dialyzed for varying lengths of time and assess the potential toxicity of residual lithium ions in cells. Complete removal of lithium ions was not achieved even after 72 h of dialysis, with a residual lithium ion content in the solution of 22.85 mg/l. SF films prepared from solutions dialyzed for 8 and 24 h had predominantly random coil or b-sheet structures, respectively. The residual lithium had little cytotoxicity in NIH3T3 fibroblast cells, but viability was compromised in cells grown on SF film prepared from solution dialyzed for 24 h.

Effect of Salts on Gelation Time of Silk Sericin Solution

  • Oh, Hanjin;Lee, Ji Young;Lee, Ki Hoon
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.27 no.2
    • /
    • pp.326-328
    • /
    • 2013
  • Sericin undergoes gelation by the structural transition from random coil to b-sheet transition. In the present study, the gelation time of sericin solution was investigated in the presence of NaCl, KCl and $CaCl_2$. The addition of salts delayed the gelation time, and $CaCl_2$ had the most pronounced effect, which delayed about 8 h at maximum. The gelation time increased with the concentration of salt. The transition of secondary structure of sericin was retarded in the presence of salt. The effect of salts on the gelation time of sericin might be due to the solvation effect of relevant cation.