• Title/Summary/Keyword: seamless

Search Result 1,178, Processing Time 0.03 seconds

Dynamic Selection of Candidate Device for the Seamless Service Using User Location Prediction (세션 모빌리티를 위한 사용자 위치 예측 통한 동적 후보 장치 선택)

  • Jung, E.-Gun;Lee, Seung-Hoon;Kim, Sang-Wook
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.510-516
    • /
    • 2008
  • In ubiquitous environment, there are no limits to utilize networks whenever and wherever you are. That pervasive networks are combined with the information devices and then create various services such as car navigation of LBS(location based service) and DMB(Digital Multimedia Broadcasting). As these kinds of services are getting more various, the complexity is also getting higher and ultimately the convergence will make people feel frustrated. One of the solutions is Context-Awareness[1] technology. User interface with context-awareness filters unnecessary information and prevents users from being blocked due to the massive information. In this paper, we describe the seamless service system based on location-awareness, which is a type of context-awareness. We developed the system based on UPnP AV Framework. This system provides the automatic terminal device selection for the nomadic user. The system establishes new connections for the ongoing streaming playback session with the new AV devices without substantial loss of playback so that the user can enjoy the seamless service. The AV device selection based on the user's location needs no user's intervention or notification so it achieves the improvement of usability and complexity.

  • PDF

Design and Evaluation of an Efficient Seamless Communication Technique for Mobile Wireless Networks (이동 무선망을 위한 효율적인 무단절 통신 기법의 설계 및 평가)

  • 배인한;김윤정
    • Journal of Korea Multimedia Society
    • /
    • v.3 no.3
    • /
    • pp.280-289
    • /
    • 2000
  • This paper presents an efficient method to provide seamless communication in mobile wireless networks. The goal of seamless communication is to provide disruption free service to a mobile user. A disruption in service could occur due to active handoffs. There are many user applications that do not require a total guarantee for disruption free service but would also not tolerate very frequent disruptions. This paper proposes an extended staggered multicast that provides a probabilistic guarantee for disruption free service. The proposed multicast forecasts the direction and velocity for a mobile host. It is possible that data packets for a mobile host are multicasted to not all neighbor cells but a par\ulcorner of neighbor cells those the mobile host will be handoff potentially on the basis of these information. Therefore, the extended staggered multicast significantly reduces the static network bandwidth usage also provides a probabilistic guarantee for disruption free service.

  • PDF

Parallel Operation Control Method of Grid-connected Inverters with Seamless Transfer for Energy Storage System in Microgrid (마이크로그리드에서 에너지 저장시스템을 위한 무순단 절체 기능을 갖는 계통연계형 인버터의 병렬운전 제어기법)

  • Park, Sung-Youl;Kim, Joo-Ha;Jung, Ah-Jin;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.3
    • /
    • pp.200-206
    • /
    • 2016
  • In the microgrid, inverters for energy storage system are generally constructed in a parallel structure because of capacity expandability, convenience of system maintenance, and reliability improvement. Parallel inverters are required to provide stable voltage to the critical load in PCC and to accurately share the current between each inverter. Furthermore, when islanding occurs, the inverters should change its operating mode from grid-connected mode to stand-alone mode. However, during clearing time and control mode change, the conventional control method has a negative impact on the critical load, that is, severe fluctuating voltage. In this study, a parallel operation control method is proposed. This method provides seamless mode transfer for the entire transition period, including clearing time and control mode change, and has accurate current sharing between each inverter. The proposed control method is validated through simulation and experiment.

A Seamless Transfer Method of Bidirectional DC-DC Converter for ESS in DC Micro-grids (DC 마이크로그리드에서 에너지 저장장치를 위한 양방향 DC-DC컨버터의 무순단 절체 제어기법)

  • Kwon, Min-Ho;Park, Jung-Sung;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.194-200
    • /
    • 2014
  • In DC micro-grid system energy storage systems (ESS) are responsible for storing energy and balancing power. Also, control target of the bidirectional DC-DC converter(BDC) for ESS should be changed depending on the operating mode. During the grid connected mode, the BDC controls the battery current or voltage. When a grid fault occurs, the BDC should change the control target to regulate the DC-bus. The BDC with conventional control method may experience large transient state during the mode change. This paper proposes a control method of BDC for ESS. The proposed control method is able to provide autonomous and seamless mode transfer by a variable current limiter. To validate the proposed concept, simulation results using PSIM and experimental results from a 2kW prototype are provided.

A study on the formability in warm hydroforming of Al 6061 seamless tube (온간액압성형공정에서 Al 6061 튜브의 소성변형특성에 관한 연구)

  • Yi, H.K.;Lee, Y.K.;Lee, J.H.;Sohn, S.M.;Moon, Y.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.318-321
    • /
    • 2006
  • In this strudy, the free-bulge test and FE analysis have been used to define the fracture criteria based on the cockroft and Latham's criterion in warm hydroforming of Al 6061 tube. Full annealing and T6 treatment for heat treatment of Al 6061 tube ware used in this study. As-extruded, full annealed and T6-treated Al 6061 seamless tubes were prepared. To evaluate the hydroformability, uni-axial tensile test and bulge test were performed between room temperature and $200^{\circ}C$. And measured flow stress was used to simulate the warm hydroforming. A commercial FEM code, DEFORM-$2D^{TM}$, was used to calculate the damage value. A forming limit based ductile fracture criteria has been proposed by the results of experimental and FE analysis. The calculated values for fracture criteria will be efficient to predict the forming limit in hydroforming for real complex shaped part.

  • PDF

Structure of Edge Routers for Seamless Connection in MPOA/MPLS Interworked Networks (MPOA/MPLS 연동망의 심리스 연결을 위한 에지 라우터 구조)

  • Kim, Dong-Ho;Lee, Soong-Hee
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.38 no.10
    • /
    • pp.10-17
    • /
    • 2001
  • For high-speed Internet services, considerations on interworking methods are required for interworking between networks with different technologies. lnterworking and structures in interworking point nodes can affect on transfer efficiency. This paper proposes interworking procedures and functions of the edge routers for overhead reduction in MPOA-MPLS networks. The MPLS networks can be based on ATM technology. Therefore, we consider ATM seamless connections for the interworking and compare the proposed method with that without seamless connection. We perform computer simulations to get both of the transfer delays and throughputs for the comparison., we describe required interworking functions and operations in the edge routers.

  • PDF

A study for efficient Media Independent Handover in environment of IEEE 802.11 wireless network interface (IEEE 802.11 무선 네트워크 인터페이스 환경에서 효율적인 개체무관 핸드오버를 위한 연구)

  • Choi, Ji-Hoon;Kim, Dong-Il
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.66-69
    • /
    • 2008
  • As a mobility support for IP have studied, Internet Engineering Task Force(ITEF) standardized the mobile IPv6 protocol. When a mobile node moves between networks, MIPv6 maintains connectivity to network and supports seamless communication, and these processes are called a Handover. IEEE 802.21 standardized MIH(Media Independent Handover) for seamless Handover. MIH used three services for Handover between low layer and upper layer. In this paper, we designed two modes on existing MIH for seamless Handover. We implemented a dual-interface mobile host(MH) model in network simulation2 (ns2) to evaluate how it performs in comparison with single-interface MH.

  • PDF

Seamless Transfer of Single-Phase Utility Interactive Inverters with a Synchronized Output Regulation Strategy

  • Xiang, Ji;Ji, Feifan;Nian, Heng;Zhang, Junming;Deng, Hongqiao
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1821-1832
    • /
    • 2016
  • This study presents a strategy using the synchronized output regulation method (SOR) for controlling inverters operating in stand-alone and grid-connected modes. From the view point of networked dynamic systems, SOR involves nodes with outputs that are synchronized but also display a desirable wave shape. Under the SOR strategy, the inverter and grid are treated as two nodes that comprise a simple network. These two nodes work independently under the stand-alone mode. An intermediate mode, here is named the synchronization mode, is emphasized because the transition from the stand-alone mode to the grid-connected mode can be dealt as a standard SOR problem. In the grid-connected mode, the inverter operates in an independent way, in which the voltage reference changes for generalized synchronization where its output current satisfies the required power injection. Such a relatively independent design leads to a seamless transfer between operation modes. The closed-loop system is analyzed in the state space on the basis of the output regulation theory, which improves the robustness of the design. Simulations and experiments are performed to verify the proposed control strategy.

Seamless and Secure Mobility Management with Location-Aware Service (LAS) Broker for Future Mobile Interworking Networks

  • Lee Minsoo;Kim Gwanyeon;Park Sehyun
    • Journal of Communications and Networks
    • /
    • v.7 no.2
    • /
    • pp.207-221
    • /
    • 2005
  • The proliferation of wireless local area networks (WLANs) offering high data rate in hot spot area have spurred the demand for possible WLANs and third-generation (3G) cellular network integration solutions as the initiative step towards 4G systems. This paper provides a novel architecture for seamless location-aware integration of WLANs into 3G cellular networks and also an analysis for the efficient handover techniques. We introduce location as a key context in secure roaming mechanism for context-aware interworking in 4G systems. The fast secure roaming with location-aware authentication is implemented at an entity called location-aware service (LAS) broker that utilizes the concepts of direction of user and pre-warming zone. The location-ware interworking architecture supports seamless roaming services among heterogeneous wireless networks including WLANs, wireless metropolitan area networks (WMANs), and 3G cellular networks. This paper also includes a description of procedures needed to implement efficient mobility and location management. We show how the LAS broker with pre-warming and context transfer can obtain significant lower latency in the vertical handover.

A Novel Seamless Direct Torque Control for Electric Drive Vehicles

  • Ghaderi, Ahmad;Umeno, Takaji;Amano, Yasushi;Masaru, Sugai
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.449-455
    • /
    • 2011
  • Electric drive vehicles (EDV) have received much attention recently because of their environmental and energy benefits. In an EDV, the motor drive system directly influences the performance of the propulsion system. However, the available DC voltage is limited, which limits the maximum speed of the motors. At high speeds, the inverter voltage increases if the square wave (SW) voltage (six-step operation) is used. Although conventional direct torque control (DTC) has several advantages, it cannot work in the six-step mode required in high-speed applications. In this paper, a single-mode seamless DTC for AC motors is proposed. In this scheme, the trajectory of the reference flux changes continuously between circular and hexagonal paths. Therefore, the armature voltage changes smoothly from a high-frequency switching pattern to a square wave pattern without torque discontinuity. In addition, because multi-mode controllers are not used, implementation is more straightforward. Simulation results show the voltage pattern changes smoothly when the motor speed changes, and consequently, torque control without torque discontinuity is possible in the field weakening area even with a six-step voltage pattern.