• Title/Summary/Keyword: sealing material

Search Result 306, Processing Time 0.028 seconds

A Study on Filter Performance of Materials in Embankment Slope during Heavy Rain (강우시 성토사면 재료의 필터조건검토에 대한 연구)

  • Kim, Sang-Hwan;Mha, Ho-Seong
    • Journal of Korean Society of societal Security
    • /
    • v.1 no.4
    • /
    • pp.65-71
    • /
    • 2008
  • This paper presents the characteristics of internal erosion of embankment slopes due to the localized heavy rain. In this study, the existing analysis methods of filter performance in embankment materials were reviewed. Based on the theoretical concept of filter conditions to prevent particles from being carried in from the adjacent embankment materials, new analysis method was suggested. According to the new analysis method for filter performance, experimental programs were carried out to investigate the filter performance for controlling and sealing any leak which develops through the embankment materials as a result of internal erosion. Three sets of small scale laboratory tests were carried out with changing the main influence factors such as rainfall intensity, gradient of slope, embankment material condition. It was found that the new analysis method for filter performance to prevent particles from being carried in from the adjacent embankment materials was more capable approach to design the filter materials in embankment slopes. The new criterion or method for satisfactory filter performance, therefore, was recommended.

  • PDF

CYTOTOXICITY OF RETROGRADE FILLING MATERIALS TESTED BY 51Cr RELEASE, MIT AND LD ACTIVITY (51Cr방출과 MTT 및 LD활성도를 이용한 역충전재의 세포독성에 관한 연구)

  • Choi, La-Young;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.409-428
    • /
    • 1994
  • Endodontic surgery is performed when conventional endodontic therapy fails or is contraindicated. In such cases, retrograde filling materials including amalgam, composite resin, and various cements have been used. Biocompatibilty and margin sealing ability of retrograde filling materials are important for the long term success of endodontic surgery. In vitro cell culture is frequently used as the method of measuring the biocompatibilty of dental materials. The purpose of this study was to evaluate the cytotoxicity of six kinds of retrograde filling materials including newly developed light curing glass ionomer cements. Each material was mixed according to. the manufacture's instruction and evaluated as : freshly mixed, 24-hour after mixing, and 168-hour after mixing respectively. The elution solution was extracted after 24-hour contact with materials using media. Cytotoxicity was evaluated by direct contact, or elution contact. Test results of radiochromium($^{51}Cr$) release, cell viability using tetrazolium dye (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl dimethyltetrazolium bromide(MTT) test and lactate dehydrogenase(LD) of damaged L929 cells were analyzed. In the $^{51}Cr$ release of direct contact, all experimental retrograde filling materials except amalgam and glass ionomer cement showed increased cytotoxicity compared to control. In the $^{51}Cr$ release of elution solution, the released $^{51}Cr$ was so minimal that it was impossible. to evlauate the cytotoxicity exactly. The elution solutions of glass ionomer cement and IRM showed marked cytotoxicity in MTT test. LD enzyme activity was highest in tests of direct contact with composite, light curing composite, and light curing glass ionomer cement and IRM. Amalgam revealed least cytotoxicity while IRM showed cytotoxicity using all three methods. Composite, light curing composite and light curing glass iomomer cement were cytotoxic in the tests of $^{51}Cr$ release and LD activity. Glass ionomer cement showed cytotoxic effect only in the MTT method. From these results it is suggested that the standardization and optimization of cytotoxicity testing, especially using elution solutions, should be strongly advised.

  • PDF

Evaluation in Physiomechanical Characteristics of Carbonized Oriented Strand Board by Different Carbonizing Conditions

  • Lee, Min;Park, Sang-Bum;Lee, Sang-Min;Son, Dong-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.2
    • /
    • pp.163-171
    • /
    • 2014
  • Environmental issues about indoor air quality have been increased and focused on volatile organic compounds (VOCs) caused cancer, asthma, and skin disease. Reducing VOCs has been attempted in many different methods such as using environmentally friendly materials and air cleaner or purifier. Charcoal is well known material for absorbing VOCs. Therefore, carbonized board from medium density fiberboard has been developed. We assumed that the source of carbonized boards can be any type of wood-based panels. In this study, carbonized boards were manufactured from oriented strand board (OSB) at 400, 600, 800, and $1000^{\circ}C$. Each carbonized OSB (c-OSB) was evaluated and determined physiomechanical characteristics such as exterior defects, dimensional shrinkage, modulus of elasticity, and bending strength. No external defects were observed on c-OSBs at all carbonizing conditions. As carbonizing temperature increased, less porosity between carbonized wood fibers was observed by SEM analysis. The higher rate of dimensional shrinkage was observed on c-OSB at $1000^{\circ}C$ (66%) than c-OSB at 400, 600, and $800^{\circ}C$ (47%, 58%, and 63%, respectively). The densities of c-OSBs were lower than original OSB, but there was no significant different among the c-OSBs. The bending strength of c-OSB increased 1.58 MPa (c-OSB at $400^{\circ}C$) to 8.03 MPa (c-OSB at $1000^{\circ}C$) as carbonization temperature increased. Carbonization temperature above $800^{\circ}C$ yielded higher bonding strength than that of gypsum board (4.6 MPa). In conclusion, c-OSB may be used in sealing and wall for decorating purpose without additional artwork compare to c-MDF which has smooth surface.

An Experimental Study on the Erosion of a Compacted Calcium Bentonite Block (압축된 칼슘벤토나이트 블록의 침식에 대한 실험적 연구)

  • Baik Min-Hoon;Cho Won-Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.4
    • /
    • pp.341-348
    • /
    • 2005
  • Bentonite has been considered as a candidate buffer material in the underground repository for the disposal of high-level radioactive waste because of its low permeability, high sorption capacity, self sealing characteristics, and durability in nature. In this study, the potential for separation of bentonite particles caused by the groundwater erosion was studied experimentally for a Korean Ca-bentonite under the relevant repository conditions. Results showed that bentonite particles can be generated at the bentonite/granite interface and mobilized by the water flow although the intrusion of bentonite into fracture by swelling pressure was observed to be small. Different processes of mobilization of theses colloids from the compacted bentonite block have been identified in this study. The concentration of particles eluted in water was increased as the flow rate increased. Thus the result reveals that the erosion of the bentonite surface due to the groundwater flow together with intrusion processes is the main mechanism that can mobilize bentonite colloids in the fracture of the granite.

  • PDF

Development and Evaluation of Cold-applied Crack Sealant for Pavement Maintenance (도로포장 보수용 상온식 균열실링 재료의 개발 및 평가)

  • Kim, Yeong Min;Jeong, Kyu Dong;Lee, Kang Hoon;Im, Jeong Hyuk
    • International Journal of Highway Engineering
    • /
    • v.19 no.2
    • /
    • pp.45-53
    • /
    • 2017
  • PURPOSES: The objectives of this study are to develop a new cold-applied crack sealant and to evaluate its properties and field applicability by comparing with other conventionally used crack sealants. METHODS : A new cold-applied crack sealant was developed by using neoprene latex to improve material properties. The fundamental properties such as viscosity, residue %, penetration, and softening point of the developed crack sealant were tested by TxDOT criteria to evaluate crack sealing capability. Moreover, the performance of the developed cold-applied crack sealant was evaluated under both laboratory and field conditions. In the laboratory, the bond property was evaluated using the developed cold-applied crack sealant and conventional hot-applied crack sealant by the bond-properties test standardized under ASTM D 6690. In the field, test sections were constructed on three areas: a trunk road, bus-only lane, and motorway, with the developed crack sealant and three conventional crack sealants. After construction, early field-inspection was performed on the test sections. RESULTS AND CONCLUSIONS : Overall, the developed cold-applied crack sealant demonstrates reasonable storage stability, durability, and bond property compared to conventional hot-applied crack sealants. From the test sections, it was established that the developed cold-applied crack sealant does not pose construction issues. Moreover, the early performance was verified through field inspection. However, as the field inspection was conducted a week after the construction, it is necessary to conduct an inspection of performance from a long-term point of view.

Development of Mathematical Model to Predict Specific Wear Rates of Graphite Seal (흑연 씰의 비마모율 예측에 관한 수학적 모델 개발)

  • Kim, Yeonwook;Kim, Jaehoon;Park, Sunghan;Lee, Hwangyu;Kim, Beomkeun;Lee, Seongbeom;Kwak, Jae Su
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.4
    • /
    • pp.67-73
    • /
    • 2014
  • The dry sliding wear behavior of graphite that is used as the sealing material to cut off hot gas was evaluated as a function of applied load, sliding speed and temperature. The reciprocating wear tests were carried out at room temperature and elevated temperatures. An attempt has been made to develop a mathematical model by response surface methodology and an analysis of variance technique was applied to confirm the validity of the developed model. Also, the wear mechanism was compared through the observation of the worn surface by SEM analysis.

PERIAPICAL TISSUE REACTION AND ROOT RESORPTION FOLLOWING REPLANTATION WITH DIFFERENT CALCIUM HYDROXIDE PASTES IN RAT (치아재식술 시 근관충전재로 사용된 수산화칼슘 제재의 치근단 조직 반응 및 치근 흡수의 평가)

  • 송상채;이승종;정일영;이찬영;금기연
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.2
    • /
    • pp.111-120
    • /
    • 2001
  • Calcium hydroxide pastes is widely used in conventional endodontics. Along with the expanded clinical use of calcium hydroxide, literatures suggest mixing calcium hydroxide with other substance. Among added substances the vehicle plays the most importance role in the overall process because it is directly related with the velocity of ionic dissociation of $Ca^{2+}$ and OH ion. In this study, we evalutated and compared periapical tissue response and root resorption after canal was filled with mixture of saline and calcium hydroxide(Junsei Chemical Co.. Japan) as a aqueous vehicle, Metapaste(Meta Co., Korea) as a viscous vehicle paste, Vitapex(Neo Dental, Japan) as a oily vehicle paste and IRM(Caulk Dentsply, USA) in replantation of rat molar. A total of 31 maxillary first molars of Sprague-Dawley female rats, 30 days old were used. The upper 1st molar was extracted and the mesiobuccal canal was filled with mixture of saline and calcium hydroxide, Metapaste, Vitapex. IRM and then replanted. Rats were sacrificed 3 weeks after replantation. the maxillae were removed. section of 4 micron were cut and stained with hematoxylin-eosin, Apical tissue response were observed under light microscope. The results were as follows: 1. Saline mixing group and Metapaste group were significant different in fibrous capsule width compared to Vitapex group and IRM group(P<0.05). 2. Saline mixing group. Metapaste group. Vitapex group and IRM group did not prevent root resorption and there were no statistical difference. 3. In saline mixing group and Metapaste group. loss of pastes were observed in all samples. From the results of our study. we observed loss of pastes in saline mixing group and Metapaste group because of water soluble property and assumed it was related to inflammation in apical area and sealing ability of material. So, we should study and develop calcium hydroxide vehicle which is easily removed and more stable and because of only 3 weeks observation we need more evaluation in long period.

  • PDF

Coronal microleakage of four temporary restorative materials in Class II-type endodontic access preparations

  • Yun, Sang-Mi;Karanxha, Lorena;Kim, Hee-Jin;Jung, Sung-Ho;Park, Su-Jung;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.1
    • /
    • pp.29-33
    • /
    • 2012
  • Objectives: The purpose of this study was to evaluate the microleakage of 4 temporary materials in teeth with Class II-type endodontic access preparations by using a glucose penetration model. Materials and Methods: Glucose reaction test was performed to rule out the presence of any reaction between glucose and temporary material. Class II-type endodontic access preparations were made in extracted human premolars with a single root (n = 10). Each experimental group was restored with Caviton (GC), Spacer (Vericom), IRM (Dentsply-Caulk), or Fuji II(GC). Microleakage of four materials used as temporary restorative materials was evaluated by using a glucose penetration model. Data were analyzed by the one-way analysis of variance followed by a multiplecomparison Tukey test. The interface between materials and tooth were examined under a scanning electron microscope (SEM). Results: There was no significant reaction between glucose and temporary materials used in this study. Microleakage was significantly lower for Caviton and Spacer than for Fuji II and IRM. SEM observation showed more intimate adaptation of tooth-restoration interfaces in Caviton and Spacer than in IRM and Fuji II. Conclusions: Compared to IRM and Fuji II, Caviton and Spacer can be considered better temporary sealing materials in Class II-type endodontic access cavities.

The Study of Characteristics on EPDM, NBR, FKM, VMQ and FVMQ for Sealing Applications to Lithium Ion Battery (리튬 이온 전지 씰링에의 응용을 위한 EPDM, NBR, FKM, VMQ 및 FVMQ 특성연구)

  • Seo, Kwan-Ho;Cho, Kwang-Soo;Yun, In-Sub;Choi, Woo-Hyuk;Hur, Byung-Ki;Kang, Dong-Gug
    • Elastomers and Composites
    • /
    • v.45 no.3
    • /
    • pp.212-216
    • /
    • 2010
  • The materials of the lithium ion battery gasket require chemical resistance to the electrolyte, electrical insulating, compression set, anti-contamination and heat resistance. To estimate suitability for rubber which has better performance to compression set than PFA, each compound were made with various rubbers, such as EPDM, NBR, FKM, FVMQ, VMQ and we checked the characteristics of each compound. Samples from each compound was deposited in Propylene Carbonate and tested for changing of Hardness and Volume during 1,000 hr with $80^{\circ}C$. EPDM and VMQ showed good performance to chemical resistance to the electrolyte, and also we could get the values over $10^{10}{\Omega}cm$ on volume resistance basis in electrical insulating. EPDM and VMQ were judged as the most suitable material.

Experimental Investigation on the Non-linearity of Nitrile Butadiene Rubber (Nitrile Butadiene Rubber의 비선형성에 대한 실험적 연구)

  • Yoo, Myung-Ho;Lee, Taek-Sung;Do, Je-Sung;Kwon, Jong-Ho
    • Elastomers and Composites
    • /
    • v.42 no.3
    • /
    • pp.159-167
    • /
    • 2007
  • Hydraulic actuators are used widely for industrial machinery. The seal made from elastomer is used as a core part of the actuator, NBR(nitrile butadiene rubber) materials with high quality of oil resistance and abrasion resistance is used widely, requiring excellent characteristic of sealing. According to applied circumstances, the actuators for industrial machinery are used under different temperature situations. In this study, three different kinds of NBR, which is Hs70, 80, 90 are determined as one of hydraulic materials. An experimental investigation is performed to confirm the non-linearity under different temperature ($-10^{\circ}C,\;20^{\circ}C,\;80^{\circ}C,\;100^{\circ}C$) situation, material constants for finite element analysis and plastic deformation in accordance with Load-unload.