• Title/Summary/Keyword: sealed cavity

Search Result 28, Processing Time 0.03 seconds

EFFECT OF BISCOVER ON THE MARGINAL MICROLEAKAGE OF COMPOSITE RESIN RESTORATION (복합레진 수복물의 변연 미세누출에 관한 BiscoverTM 전색제의 효과)

  • Cho, Young-Gon;Choi, Hee-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.5
    • /
    • pp.355-362
    • /
    • 2005
  • The purpose of this study was to compare the effect on marginal leakage of a resin surface sealant (Biscover) applied before or after polymerization of composite resin to unsealed composite restorations. Thirty Class V cavities with the occlusal margin in enamel and cervical margin in dentin or cementum were prepared on the buccal surfaces of sound extracted molars and restored with a microfilled light-cured composite resin (Micronew). Restorations were randomly assigned into one of three equal groups (n = 10): a control group - no surface sealing, group 1 - applied Biscover after polymerization of the composite resin. and group 2 - applied Biscover before polymerization of the composite resin. Specimens were thermocycled, immersed in a $20\%$ methylene blue solution for 4 hoots, sectioned longitudinally, and analyzed for leakage at the occlusal and gingival margins. The results of this study were as follows 1. In sealed group, group 2 showed higher microleakage than group 1 at both occlusal and gingival margins. but there was no significant difference between two groups (p > 0.05). 2. Unsealed control group showed a little higher microleakage than sealed group at occlusal margins, and a little Higher or similar microleakage than sealed group at gingival margins (p > 0.05) 3. Control group and group 2 showed significantly less microleakage at the occlusal margins, but group 1 showed no significantly difference between microleakage at the occlusal and gingival margins.

LiF(Mg, Cu, Na, Si) Thermoluminescent Dosimeters for In-phantom Dosimetry of $^{60}Co\;{\gamma}$-rays (LiF(Mg, Cu, Na, Si) 열형광선량계를 사용한 $^{60}Co\;{\gamma}^-$선의 수중 흡수선량 측정)

  • Kim, Hyun-Ja;Chung, Woon-Hyuk;Lee, Woo-Gyo;Doh, Sih-Hong
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.57-65
    • /
    • 1990
  • Newly developed LiF(Mg, Cu, Na, Si) thermoluminescence phosphors sealed in a plastic capsules (32mm dia., 0.9mm wall thickness) were used for in-phantom dosimetry of $^{60}Co$ $\gamma$-irradiation. The absorbed doses in water were determined by applying the general cavity theory to the absorbed dose in TLD cavity, which was computed from exposure. The absorbed doses at various sites in the water-phantom were measured by LiF(Mg, Cu, Na, Si) TLD and compared with doses obtained by the ionization method. Both results were consistent within the experimental fluctuation$({\pm}3%)$ Central axis percentage depth doses and phantom-air ratios measured by LiF(Mg. Cu, Na, Si) TLD showed good agreement with the published values[Br. J. Radiology, Suppl. 17(1983)].

  • PDF

Early Healing Responses of the Skin Wounds in the Korean Fire-Bellied Toad, Bombina orientalis (무당개구리 (Bombina orientalis) 피부의 초기 상처치유반응)

  • Jeong, Moon-Jin;Moon, Myung-Jin
    • Applied Microscopy
    • /
    • v.28 no.3
    • /
    • pp.329-343
    • /
    • 1998
  • Early wound healing responses in the skin of the Korean fire bellied toad, Bombina orientalis, were examined using histochemical , scanning and transmission electron microscopical techniques. Cutaneous wounds were induced by sharp razor blade , and maintained in special cages for up to 3 days. By this treatment whole parts of epithelium and dermis were profoundly affected. After injury, retraction of damaged surface of the skin was observed. At 3 hours after injury, poly-band was form by mucous substance. The wound skin consisted of mucous gland secreted mucous substance which flows into wound cavity and the wound area was sealed by mucous substance which form thick layer at 6 hours. It appeared that natural disposition showed acid and neutral mucous substance by reaction of PAS and Alcian blue (pH 2.5) staining. After formation of the poly-band, epithelial cells were formed by migration of regenerating epithelial cells. These cells moved over the wound surface by migration at 12 hours after wounding. Poly-band was much increased in thickness and migrating cells were completely formed wound closure at 24 hours post-wounding. After 72 hours regenerated epithelial layer consists of four or five cell layers which are similar to clear, granular, and spinous layer.

  • PDF

Right Bochdalek hernia with pneumothorax in adult (성인에서 기흉을 동반한 우측의 Bochdalek Hernia 1)

  • 백광제
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.729-734
    • /
    • 1984
  • Bochdalek hernia is a type of congenital diaphragmatic defect in the posterolateral portion of the diaphragm. The defect is usually Lt. sided due to protective effect of liver on right. Sex distribution is male preponderance [2:1] and it is diagnosed during neonate, mostly first 24 hours, due to severe respiratory distress. We experienced a rare case of old aged female patient with congenital Bochdalek hernia on Rt. side which was found incidentally during treatment of spontaneous pneumothorax of Rt. side. 17 year old female patient was admitted to CS department for chest discomfort on right and mild dyspnea with duration of 20 days. Under the diagnosis of spontaneous pneumothorax, Rt. closed thoracostomy and underwater sealed drainage with continuous suction was applied. On follow-up chest x-ray, poorly defined hazy increased density with multiple air-fluid levels in Rt. lower lung field and Lt. subphrenic free air were noted. So, Barium enema was done under the impression of Rt. diaphragmatic hernia, and nearly entire colon proximal to sigmoid was demonstrated in the Rt. hemithorax. Operation was done-for surgical repair of defected diaphragm through Rt. posterolateral thoracotomy. Operative findings were as follows; 1.Hypoplastic Rt. lung, esp. RML & RLL. 2.Nearly entirely intestines were herniated. 3.Diaphragmatic defect was located on posterolateral portion of the diaphragm, about 10x3cm in size with blunt smooth margin. 4.A large bleb on apex of RUL of lung. Herniated intestines were repaired into abdominal cavity manually and defect of diaphragm was repaired with No. I black silk interrupted sutures directly, and bleb was resected. Postoperative courses were uneventful and the patient was discharged with good condition on POD 14th.

  • PDF

Variable-focus Liquid Lens Based on a Laterally-integrated Thermopneumatic Actuator

  • Lee, June Kyoo;Park, Kyung-Woo;Lim, Geunbae;Kim, Hak-Rin;Kong, Seong Ho
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.22-28
    • /
    • 2012
  • We report a focal-length tunable liquid lens based on thermopneumatically driven fluidic pressure. The fluidic pressure is generated by deformation of an elastomeric diaphragm induced by thermopneumaticity from a laterally integrated microheater sealed within an air chamber. The pressure is transmitted by a confined liquid to a lens diaphragm through an internal fluid channel. The liquid filling under the lens diaphragm functions as a liquid lens for dynamic focusing with properties depending on the curvature of the deformed diaphragm. The diaphragm area of the air chamber is designed five times larger than that of the lens cavity to yield high focal-length tunability by amplified deflection of the lens diaphragm. With our method, we achieved excellent focal-length tunability from infinity (without an input current) to 4 mm (with an input current of 12 mA) with a lens aperture diameter of 2 mm.

Development of Batteryless SAW-based Integrated Microsensor and Wireless Measurement Technique (무전지 SAW 기반 마이크로 통합센서 및 무선 측정기술 개발)

  • Oh, Hae-Kwan;Kim, Tae-Hyun;Wang, Wen;Yang, Sang-Sik;Lee, Kee-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1430-1435
    • /
    • 2007
  • We developed a 440MHz surface acoustic wave (SAW) microsensor integrated with pressure-temperature sensors and ID tag. Two piezoelectric substrates were bonded, in which ${\sim}150\;{\mu}m$ cavity was structured. Four sides were completely sealed by JSR photoresist (PR). Pressure sensor was placed on the top substrate, whereas ill tag and temperature sensor were placed on the bottom substrate. Using network analyzer, the developed microsensor was wirelessly tested. Sharp reflection peaks with high S/N ratio, small signal attenuation, and small spurious peaks were observed. All the reflection peaks were well matched with the coupling of mode (COM) simulation results. With a 10mW RF power from the network analyzer, a ${\sim}1$ meter readout distance was observed. Eight sharp ON reflection peaks were observed for ID tag. Temperature sensor was characterized from $20^{\circ}C$ to $200^{\circ}C$. A large phase shift per unit temperature change was observed. The evaluated sensitivity was ${\sim}10^{\circ}/^{\circ}C$.

A Study of Pathogenesis and Treatment of Spontaneous Pneumothorax (자연성 기흉의 성인과 치료에 대한 고찰)

  • 홍완일;김진식
    • Journal of Chest Surgery
    • /
    • v.1 no.1
    • /
    • pp.11-18
    • /
    • 1968
  • Author studied the possible pathogenesis of spontaneous pneumothorax and its effective treatment in 33 cases, and the results obtained as follows:1) Of the 33 cases, 15 cases were originated from pulmonary tuberculosis, 11 cases were non-tuberculous natures and 7 cases were followed by traumatic chest injuries which were not associated with a laceration of the lung or rib fractures.2) So called "Idiopathic spontaneous pneumothorax" seemed mostly to be caused by rupture of the emphy- sematous blebs.3) Spontaneous pneumothorax, in process of the pulmonary tuberculosis, seemed to be caused by the rupture of blebs which was formed with a pathological process of chronic pulmonary tuberculosis.4) Author experienced interesting cases of giant blebs which had been fully occupied the right thoracic cavity. At first, it was misdiagnosed as extensive spontaneous pneumothorax on X-ray which was revealed extensive pleural air shadow with total atelectasis of the right lung. A pneumonectomy was performed together with the giant multiple blebs.5] Generally, closed thoracotomy with water-sealed drainage is the treatment of choice in spontaneous pneumothorax. However, open thoracotomy and adequate surgical procedures should be undertaken in patients with continuous air leakage or recurrent attack of spontaneous pneumothorax.aneous pneumothorax.

  • PDF

AN EXPERIMENTAL STUDY ON THE EFFECT OF COMPOSITE RESIN AND BACTERIA TO PULP RESPONSE (복합(複合)레진과 세균(細菌)이 치수반응(齒髓反應)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Cho, Sung-Sik;Kim, Yung-Hai
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.1
    • /
    • pp.53-67
    • /
    • 1988
  • An investigation was carried out to compare the pulp responses against a few type of composite and streptococcus mutans contamination under the zinc oxide eugenol cement, and also confirmed pulpal responses of various composites with or without base. Seventy eight teeth from 6 dogs were employed and divided into 6 groups. Class V cavities were prepared on each tooth routinely with low speed dental engine. Paper disc about 0.3mm thick was immersed in the BHI broth in which streptococcus mutans had been enriched and the disc was inserted on the cavity floor prior to filling. Scotch bond puls Silux as Bis-GMA system composite resin and Helimolar as urethane system composite resin were adopted. Control group: Zinc-Oxide Eugenol cement filling Experimental groups: Group 1. Scotch bond + Silux filling with Dycal base Group 2. Heliomolar filling with Dycal base Group 3. Scotch bond + Silux filling without base Group 4. Heliomolar filling without base Group 5. Streptococcus mutans application. All cavities were sealed with thick ZOE cement to avoid marginal leakage. Postoperative intervals of 1, 2, 3, 4, 5 and 6 weeks teeth were carefully extracted, processed and stained with Hematoxylin and Eosin. The results were as follows: 1. S. mutans application group and composites without any base showed more severe pupal response than control group and dyca based groups. 2. The experimental group of S. mutans application showed severe response in the early stage compared to the two groups of composite resin without base, but no significant difference was found following periods. 3. The difference of pulpal response is not significant between Bis-GMA system and urethane system. 4. Streptococcus mutans application group and composites without base groups showed the evidence of histologic recovery at the six week cases and the large amount of reparative dentin was the prominent feature. 5. Pulp responses against every material were inclined to normal according to the time elapsed.

  • PDF

Wear, microleakage and plastic deformation of an implant-supported chair-side bar system

  • Mehl, Christian Johannes;Steiner, Martin;Ludwig, Klaus;Kern, Matthias
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.323-328
    • /
    • 2015
  • PURPOSE. This in-vitro study was designed to evaluate retention forces, microleakage and plastic deformation of a prefabricated 2-implant bar attachment system (SFI-Bar, Cendres+$M{\acute{e}}taux$, Switzerland). MATERIALS AND METHODS. Two SFI implant-adapters were torqued with 35 Ncm into two implant analogues. Before the tube bars were finally sealed, the inner cavity of the tube bar was filled with liquid red dye to evaluate microleakage. As tube bar sealing agents three different materials were used (AGC Cem (AGC, resin based), Cervitec Plus (CP; varnish) and Gapseal (GS; silicone based). Four groups with eight specimens each were tested (GS, GS+AGC, AGC, CP). For cyclic loading, the attachment system was assembled parallel to the female counterparts in a chewing simulator. The mean retention forces of the initial and final ten cycles were statistically evaluated (ANOVA, ${\alpha}{\leq}.05$). RESULTS. All groups showed a significant loss of retention forces. Their means differed between 30-39 N initially and 22-28 N after 50,000 loading cycles. No significant statistical differences could be found between the groups at the beginning (P=.224), at the end (P=.257) or between the loss of retention forces (P=.288). Microleakage occurred initially only in some groups but after 10,000 loading cycles all groups exhibited microleakage. CONCLUSION. Long-term retention forces of the SFI-Bar remained above 20 N which can be considered clinically sufficient. The sealing agents in this study are not suitable to prevent microleakage.

COMPARISON OF THE SEALING ABILITY OF VARIOUS RETROGRADE FILLING MAIERIALS (수종의 역충전 재료의 치근단 밀폐력 비교)

  • 황윤찬;강인철;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.379-386
    • /
    • 2001
  • This study was performed to evaluate the sealing ability of various retrograde filling materials by using bacterial penetration and dye penetration test. One hundred and forty extracted human teeth with single, straight canals and mature apiece were collected and used for this study. All canals were instrumented using an engine driven Ni-Ti file (ProFile). After removing 3mm from the apex of tooth, a standardized 3mm root end cavity was prepared using an ultrasonic instrument. The 70 teeth were randomly divided into 7 groups : 6 groups for retrograde filling using Super-EBA, ZOE, Chelon-Silver, IRM, ZPC and amalgam. The 7th group was used as a negative control. Nail varnish was applied to all external root surfaces to the level of the reseated root ends to prevent lateral microleakages. The specimens were then sterilized in an ethylene oxide sterilizer for 24 hours. 2 mm of the reseated root was immersed in a culture chamber containing a Tripticase Soy Broth with a phenol red indicator. The coronal access of each specimen was inoculated every 72 hours with suspension of Proteus vulgaris. The culture media were observed every 24hours for color change indicating bacterial contamination. The specimens were observed for 4weeks. The remaining 70 teeth were submitted to a dye penetration test. The canals of all teeth were first sealed with AH26 and obturated using an Obtura II system. Root resection, root end preparation and retrograde filling was performed as above. All specimens were suspended in 2% methylene blue dye for 72 hours before being ion gitudinally split. The degree of dye penetration was then measured using a stereomicroscope at 10 magnification and evaluated. The results were as floows : 1. In the bacterial penetration, the degree of leakage was the lowest in the Super-EBA, followed by, in ascending order, ZOE, Chelon-Silver IRM and ZPC. The amalgam showed highest bacterial leakage of all(p<0.01). 2. In the dye penetration, the degree of microleakage was the lowest in the Chelon-Silver and Super-EBA, followed by, in ascending order, IRM, ZPC. The ZOE and amalgam showed the highest microleakage of all (p<0.05). These results suggested that the eugenol based cement, Super-EBA, have excellent sealing ability as a retrograde filling material.

  • PDF