• Title/Summary/Keyword: sea water intrusion

Search Result 109, Processing Time 0.02 seconds

제주도 동부 해안대수층에서의 수평 유향.유속 검층자료 해석

  • Kim Gu-Yeong;Seong Hyeon-Jeong;Kim Tae-Hui;Park Gi-Hwa;Park Yun-Seok;Go Gi-Won;Park Won-Bae;U Nam-Chil
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.271-275
    • /
    • 2005
  • The horizontal heat-pulse flowmeter was used to measure grounwater flow in volcanic rocks at sites in eastern part of Jeju Island, Korea. Three boreholes, Handong-1, Jongdal-1, and Susan-1, which are located at close distance from the coastline, were selected from the sea water intrusion monitoring wells. To evaluate the direction and velocity of the groundwater flow, 6 to 8 measuring points for each borehole were chosen. There are two major flow directions at Handong-1, which are toward north-east and south-east directions and velocity ranges from $2.2{\sim}3.0cm/hr\;and\;0.6{\sim}1.0cm/hr$, respectively. For Jongdal-1, two major flow directions were detected that are east and north-west and velocity ranges from $1.2{\sim}2.0cm/hr$. For Susan-1, major flow is toward east direction and the ,velocity ranges from $2.2{\sim}2.7cm/hr$ at depth $60{\sim}70m$,\;and\;0.8{\sim}0.9cm/hr$ at depth $70{\sim}80m$. In order to evaluate the tidal effect on groundwater flow, direction and velocity were measured at specific depth with time, At depth 57m of Susan-1, the velocity increased during the tidal variation, The flow direction and velocity varies with different depths, and they are also affected by tidal fluctuation. Thereafter, care must be taken when flow direction and velociy is estimated indirectly by using hydraulic head at monitoring wells.

  • PDF

An Analysis of Seawater Effect on Groundwater Quality, in the Region of Sinan-gun area, Jeonam, Korea (전남 신안군 지역의 지하수 수질에 대한 해수의 영향 분석)

  • Shin, Kyungsun;Koh, Dong-Chan;Lee, Jeonghoon
    • Journal of the Korean earth science society
    • /
    • v.38 no.7
    • /
    • pp.570-580
    • /
    • 2017
  • The purpose of the study was to evaluate the groundwater quality of Sinan-gun, Jeollanam-do, an island located in the southern part of the Korean peninsula where the effect of seawater on the groundwater quality had not been investigated in the past. In order to evaluate its effect, the hydrogeological parameters including groundwater quality and major dissolved components were investigated. The water quality was measured four times in the field, and 74 of 163 samples that showed the high conductivity value of more than $500{\mu}S/cm$ and the influence of seawater on the groundwater were analyzed by $Cl^-/HCO_3{^-}$ molar ratio. The results showed that, 40 samples out of 74 were found to have a value of 2.8 or more, indicating severe and very severe effects. According to the type of groundwater quality, the ratio of samples belonging to Na-Cl type, which is considered to be influenced by the direct seawater, is 35.3% for bedrock groundwater and 52.5% for weathered zone and alluvial groundwater. In the evolution stage of groundwater due to seawater infiltration, the type of Ca-Cl prior to the Na-Cl type is 44.1% in bedrock groundwater and 45% in weathered zone and alluvial groundwater. The effect of sea water on the aquifer is likely to be influenced by distance from the shore, pumped water, and tide.

Distribution and Species Composition of Phytoplankton in the Southern Waters of Korea and their Relation to the Character of Water Masses (한국남해의 식물플랑크톤의 분포와 수괴특성)

  • PARK Joo-Suck;LEE Sam-Geun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.23 no.3
    • /
    • pp.208-214
    • /
    • 1990
  • Phytoplankton samples for this study were collected by Van Dorn Sampler at 28 oceanographic stations in the southern waters of Korea in February, April and August, 1988 to characterize the distribution and species composition of phytoplankton and their relation to the movement of water masses. During the study periods, phytoplankton standing crops in the southern waters were maximum in April and minimum in February. When the geographical distribution and abundance of the phytoplankton were considered, the highest standing crops were found near the front zone formed between Cheju Island and Tsushima Island. Therefore, their abundance depends ell the location of the front zone. On the other hand, there were relatively low standing crops in the open sea off the coastal area from the front zone in February and August. The cause of the unusal low standing crops found in August at the station 205/01, the central part of the coastal area of the southern waters where the largest standing crops occurred in February and April, seems to be due to the intrusion of Tsushima warm waters. This is because the waters at the station have high temperature and salinity, poor dissolved oxygen and nutrient salts, which are identical to the characteristics of proper Tsushima warm waters. It seems that these warm waters may affect the poor productivity in this area. Seventy-two species in thirty-three genera of the phytoplankton were indentified from the samples. Among them, 61 species in 27 genera belong to diatoms and 12 species in 7 genera to dinoflagellates. The largest number of phytoplankton species occurred in August while the largest number of the tells in April. Predominant species were Eucampia zodiacus in February, Skeletonema costatum and Chaetoceros curvisetus in April and Chaetoceros affinis in August. Eucampia zodiacus which was dominant in February and April seems to be a indicator of the southern coastal waters of Korea and mixed waters west of Cheju Island.

  • PDF

Long-Term Observation of Temperature in the Coastal Waters Adjacent to the Wolsung Nuclear Power Plant (월성 원자력 발전소 주변 해역의 장기간 수온관측)

  • Chung, Jong-Yul;Kang, Hyoun-Woo;Shin, Young-Jae;Kim, Kye-Young;Jun, Ho-Kyung
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.3 no.4
    • /
    • pp.183-192
    • /
    • 1998
  • The long-term observation of temperature in the coastal waters adjacent to the Wolsung Nuclear Power Plant has been carried out from November 10, 1996 to August 22, 1997, for approximately 280 days using a real-time temperature measurement buoy system. The sea-surface temperature was measured at every 10 minute using 10 buoys. The vertical structure of temperature was investigated near the outlet of the plant with two thermistor chains equipped with 10 sensors at 1 m interval The monthly averaged temperature was the lowest with spatial average of $12.8^{\circ}C$ in February and was the highest in August with spatial average of $19.6^{\circ}C$. The extremely low temperature was frequently observed between June and August, which seems to be the consequence of the intrusion of cold water near the southeastern coast of Korea. Distributions of the daily and hourly averaged temperature show that the highest temperature always occurred near the outlet of the plant and the warm-water patch moved along the north-south direction with the semidiurnal period. The semidiurnal fluctuation of temperature was also observed near the surface of the vertical profiles. The spectral analysis of temperature between February and April 1997 shows that the semidiurnal components prevailed near the outlet. It is likely that the semidiurnal components were due to the prevailing semidiurnal tide in this region. In August 1997, the diurnal components were dominant at the surface water of all stations except Station 12, which suggests that the warm water from the outlet of the plant has less effects in summer on the surrounding waters than the strong solar radiation.

  • PDF

Ichthyotoxic Cochlodinium polykrikoides red tides offshore in the South Sea, Korea in 2014: I. Temporal variations in three-dimensional distributions of red-tide organisms and environmental factors

  • Jeong, Hae Jin;Lim, An Suk;Lee, Kitack;Lee, Moo Joon;Seong, Kyeong Ah;Kang, Nam Seon;Jang, Se Hyeon;Lee, Kyung Ha;Lee, Sung Yeon;Kim, Mi Ok;Kim, Ji Hye;Kwon, Ji Eun;Kang, Hee Chang;Kim, Jae Seong;Yih, Wonho;Shin, Kyoungsoon;Jang, Poong Kook;Ryu, Joo-Hyung;Kim, Sung Young;Park, Jae Yeon;Kim, Kwang Young
    • ALGAE
    • /
    • v.32 no.2
    • /
    • pp.101-130
    • /
    • 2017
  • The ichthyotoxic Cochlodinium polykrikoides red tides have caused great economic losses in the aquaculture industry in the waters of Korea and other countries. Predicting outbreak of C. polykrikoides red tides 1-2 weeks in advance is a critical step in minimizing losses. In the South Sea of Korea, large C. polykrikoides red tide patches have often been recorded offshore and transported to nearshore waters. To explore the processes of offshore C. polykrikoides red tides, temporal variations in 3-dimensional (3-D) distributions of red tide organisms and environmental parameters were investigated by analyzing 4,432 water samples collected from 2-5 depths of 60 stations in the South Sea, Korea 16 times from May to Nov, 2014. In the study area, the vegetative cells of C. polykrikoides were found as early as May 7, but C. polykrikoides red tide patches were observed from Aug 21 until Oct 9. Cochlodinium red tides occurred in both inner and outer stations. Prior to the occurrence of large C. polykrikoides red tides, the phototrophic dinoflagellates Prorocentrum donghaiense (Jun 12 to Jul 11), Ceratium furca (Jul 11 to Aug 21), and Alexandrium fraterculus (Aug 21) formed red tides in sequence, and diatom red tides formed 2-3 times without a certain distinct pattern. The temperature for the optimal growth of these four red tide dinoflagellates is known to be similar. Thus, the sequence of the maximum growth rates of P. donghaiense > C. furca > A. fraterculus > C. polykrikoides may be partially responsible for this sequence of red tides in the inner stations following high nutrients input in the surface waters because of heavy rains. Furthermore, Cochlodinium red tides formed and persisted at the outer stations when $NO_3$ concentrations of the surface waters were < $2{\mu}M$ and thermocline depths were >20 m with the retreat of deep cold waters, and the abundance of the competing red-tide species was relatively low. The sequence of the maximum swimming speeds and thus potential reachable depths of C. polykrikoides > A. fraterculus > C. furca > P. donghaiense may be responsible for the large C. polykrikoides red tides after the small blooms of the other dinoflagellates. Thus, C. polykrikoides is likely to outgrow over the competitors at the outer stations by descending to depths >20 m and taking nutrients up from deep cold waters. Thus, to predict the process of Cochlodinium red tides in the study area, temporal variations in 3-D distributions of red tide organisms and environmental parameters showing major nutrient sources, formation and depth of thermoclines, intrusion and retreat of deep cold waters, and the abundance of competing red tide species should be well understood.

A Feasibility Study of AMT Application to Tidal Flat Sedimentary Layer (갯벌 지역의 하부퇴적층에 대한 AMT 탐사의 적용 가능성 평가)

  • Kwon, Byung-Doo;Lee, Choon-Ki;Park, Gye-Soon;Choi, Su-Young;Yoo, Hee-Young;Choi, Jong-Keun;Eom, Joo-Young
    • Journal of the Korean earth science society
    • /
    • v.28 no.1
    • /
    • pp.64-74
    • /
    • 2007
  • The marine seismic prospecting using a research vessel in the shallow sea near the coastal area has certain limits according to the water depth and survey environment. Also, for the electrical resistivity survey at seashore area, one may need a specially designed high-voltage source to penetrate the very conductive surface layer. Therefore, we have conducted a feasibility study on the application of magnetotelluric method (MT), a passive geophysical method, on investigating of shallow marine environment geology. Our study involves both theoretical modeling and field survey at the tidal flat area which represent the very shallow marine environment. We have applied the audio-frequency magnetotelluric (AMT) method to the intertidal deposits of Gunhung Bay, west coast of Korea, and analysed the field data both qualitatively and quantitatively to investigate the morphology and sedimentary stratigraphy of the tidal flat. The inversion of AMT data well reveals the upper sedimentary layer of Holocene intertidal sediments having a range of 13-20 m thickness and the erosional patterns at the unconformable contact boundary. However, the AMT inversion results tend to overestimate the depth of basement (30-50 m) when compared with the seismic section (27-33 m). Since MT responses are not significantly sensitive to the resistivity of middle layer or the depth of basement, the AMT inversion result for basement may have to be adjusted using the comparison with other geophysical information like seismic section or logging data if possible. But, the AMT method can be an effective alternative choice for investigating the seashore area to get important basic informations such as the depositional environment of the tidal flat, sea-water intrusion and the basement structure near the sea shore.

Characteristics of Spatio-temporal Variation of the Water Quality in the Lower Keum River (금강 하류역에서 수질의 시공간적 변화특성)

  • YANG Han-Soeb;KIM Seong-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.23 no.3
    • /
    • pp.225-237
    • /
    • 1990
  • Various chemical constituents were measured from April to August 1988 at the down-ward 20 stations of Keum River, which is located in the Midwest of Korea, to understand the characteristics of water quality with respect to spatio-temporal variations of each constituent. The 24-hrs continuous measurements with 2-hrs interval were made simultaneously at station 2 near the estuary weir and station 9(Ganggyeong) of 35 km upstream from the weir in April. By the results observed for one day in April at station 2, salinity has a range of $7.88\~22.14\%_{\circ}$ and its temporal variability is identical to the pattern of tidal cycle in the neigh-bouring Kunsan Harbor. However, turbidity shows relatively high values only at an interval of 4~5 hours after the lowest salinity time, though hourly fluctuation of pH is very small. Silicate and dissolved inorganic nitrogen have inversively linear correlationships with salinity, implying the concentration of the two nutrients strongly regulated by estuarine mixing of sea and river waters. In contrast, phosphate sustains roughly a constant level over a wide salinity range and distinctly lower values than those corresponding to nitrate in the oceans. Such distributions of phosphate have been observed in some estuaries, and interpreted as driven by removal of dissolved phosphate into bottom sediments and the bufforing of phosphate by particulate matter. COD values at station 2 are relatively high in day-time(particularly afternoon) and in high-salinity periods. At station 9, saltwater intrusion was never found but water level changed to the extent of 2.5 m for one day. Although each parameter at this station exhibits very slight variations in their abundance for 24 hours compared with station 2, the contents of COD, silicate and ammonia are significantly higher than at station 2. Concentration of suspended matter is relatively high in the brackish water region up to $\~20$ km above the river mouth, probably due to strong tidal stirring of the bottom de-posits. Also, relatively high pH, COD and $O_2$ saturation at the upward stations of $40\~50$ km from the weir are presumably attributable to active photosynthesis of plants in the region. In general, COD and nutrients except phosphate are higher values at the upper stations than in the estuary zone, and show the highest abundances in July nearly at all stations. Finally, in the estuarine region tidal mixing of sea-river waters seems to be an important factor controlling the distributions of turbidity, COD, silicate and nitrate as well as salinity. However, water quality in the upward fresh-water zone is remarkably variable according to months or seasons.

  • PDF

Verticality 3D Monitoring System for the Large Circular Steel Pipe (대형 원형강관 수직도 모니터링을 위한 3D 모니터링 시스템)

  • Koo, Sungmin;Park, Haeyoung;Oh, Myounghak;Baek, Seungjae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.870-877
    • /
    • 2020
  • A suction bucket foundation, especially useful at depths of more than 20m, is a method of construction. The method first places an empty upturned bucket at the target site. Then, the bucket is installed by sucking water or air into it to create negative pressure. For stability, it is crucial to secure the verticality of the bucket. However, inclination by the bucket may occur due to sea-bottom conditions. In general, a repeated intrusion-pulling method is used for securing verticality. However, it takes a long time to complete the job. In this paper, we propose a real-time suction bucket verticality monitoring system. Specifically, the system consists of a sensor unit that collects raw verticality data, a controller that processes the data and wirelessly transmits the information, and a display unit that shows verticality information of a circular steel pipe. The system is implemented using an inclination sensor and an embedded controller. Experimental results show that the proposed system can efficiently measure roll/pitch information with a 0.028% margin of error. Furthermore, we show that the system properly operates in a suction bucket-based model experiment.

Crack and Time Effect on Chloride Diffusion Coefficient in Nuclear Power Plant Concrete with 1 Year Curing Period (1년 양생된 고강도 원전 콘크리트의 염화물 확산에 대한 균열 및 시간효과)

  • Chun, Ju-Hyun;Ryu, Hwa-Sung;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.83-90
    • /
    • 2017
  • Concrete structure for nuclear power plant is mass concrete structure with large wall depth and easily permits cracking in early age due to hydration heat and drying shrinkage. It always needs cooling water so that usually located near to sea shore. The crack on concrete surface permits rapid chloride intrusion and also causes more rapid corrosion in the steel. In the study, the effect of age and crack width on chloride diffusion is evaluated for the concrete for nuclear power plant with 6000 psi strength. For the work, various crack widths with 0.0~1.4 mm are induced and accelerated diffusion test is performed for concrete with 56 days, 180days, and 365 days. With increasing crack width over 1.0mm, diffusion coefficient is enlarged to 2.7~3.1 times and significant reduction of diffusion is evaluated due to age effect. Furthermore, apparent diffusion coefficient and surface chloride content are evaluated for the concrete with various crack width exposed to atmospheric zone with salt spraying at the age of 180 days. The results are also analyzed with those from accelerated diffusion test.