• Title/Summary/Keyword: sd-system

Search Result 1,034, Processing Time 0.027 seconds

Neuropsychologic Analysis of Acute Bell's Palsy (급성 벨마비 환자의 자가보고형 불안 및 우울평가)

  • Yoo, Ji-Hoon;Han, Woo-Ho;Lee, Dong-Kuck
    • Annals of Clinical Neurophysiology
    • /
    • v.11 no.2
    • /
    • pp.48-53
    • /
    • 2009
  • Background: Bell's palsy produces a complex problem that involves not only facial motor weakness, but also psychiatric issues. However, the relationship between facial neuromotor system impairment and psychological adjustment has not been well understood. Methods: We have performed psychological evaluations in patients with acute unilateral Bell's palsy within 2 weeks after onset. Thirty patients with Bell's palsy (10 men, 20 women) were included, who were diagnosed by neurologic examination, electrophysiologic study and/or brain MRI. We measured facial motor scale of impairment (House-Brackmann, HB scale) and psychosocial adjustment [Beck Anxiety Inventory (BAI), Beck Depression Inventory (BDI)] at the time of initial presentation and 1 month after diagnosis. Results: The age of the enrolled patients ranged from 16 to 80 years. The mean grade of initial and follow up HB scale were 3.87 (SD: 0.63, range 2~5) and 1.77 (SD: 1.10, range 1~5). The mean score of initial and follow up BAI, BDI were 11.93 (range; 0 to 47, SD: 9.65, very low anxiety), 14.73 (range; 0 to 41, SD: 9.21 minimal depression) and 7.5 (range; 0 to 36, SD: 8.58, very low anxiety), 9.33 (range; 0 to 30, SD: 8.19 minimal depression). There was positive correlation between improvement of HB scale and improvement of BAI and BDI score. Conclusions: Bell's palsy is associated with the psychological problems such as depression and anxiety, and the improvement of motor symptom is associated with the improvement of these psychological problems.

  • PDF

Size Determination of Pollens Using Gravitational and Sedimentation Field-Flow Fractionation

  • Kang, Dong-Young;Son, Min-Seok;Eum, Chul-Hun;Kim, Won-Suk;Lee, Seung-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.4
    • /
    • pp.613-618
    • /
    • 2007
  • Pollens are known to be an allergen. They penetrate human respiratory system, triggering a type of seasonal allergic rhinitis called pollen allergy (hey fever). The purpose of this study is to test two field-flow fractionation (FFF) techniques, gravitational FFF (GrFFF) and sedimentation FFF (SdFFF), for their applicability to sizecharacterization of micron-sized pollens. Both GrFFF and SdFFF are elution techniques, providing sequential elution of particles based on size. They allow the size distribution as well as the mean size of the sample to be determined from the elution time. In this study, GrFFF and SdFFF were used to determine the size distribution of Paper Mulberry and Bermuda Grass pollens. For the Paper Mulberry pollen, the mean size obtained by GrFFF is 12.7 μm, and agrees rather well with the OM data with the relative error of 8.0%. For the Bermuda Grass pollen, the mean size obtained by GrFFF is 32.6 μm with the relative error of 12.3%. The mean sizes determined by SdFFF are 12.4 (relative error = 10.1%) and 27.1 μm (relative error = 5.2%) for the Paper Mulberry and the Bermuda Grass pollen, respectively. Although SdFFF tends to yield more accurate size distribution due to lower band broadening under the field strength higher than 1 G, the sizes determined by GrFFF were not significantly different from those by SdFFF.

Acoustical characteristics of prototype mechanical white noise generator as an underwater sound source (시험 제작한 기계식 백색소음기 수중음원의 음향적 특성)

  • Shin, Hyeon-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.3
    • /
    • pp.244-251
    • /
    • 2014
  • This paper describes a prototype mechanical white noise generator has a source level of more than 170.0 dB (re $1{\mu}Pa$ at 1 m) at the frequency range of 10 Hz to 100 kHz. The results of performance evaluation of the generator are as follows. The average source level of the generator measured by a step of $15^{\circ}$ in horizontal (0 to $360^{\circ}$, 25 points) was 185.2 (SD (standard deviation): 2.3) dB (re $1{\mu}Pa$ at 1 m). The maximum and minimum source levels were appeared at the frequency range of 2.5 to 5.0 kHz and around 100 kHz, respectively. The average source levels at $0^{\circ}$, $90^{\circ}$, $180^{\circ}$ and $270^{\circ}$ were 162.9 (SD: 10.6), 168.4 (SD: 10.0), 162.1 (SD: 9.1) and 166.5 (SD: 11.1) dB (re $1{\mu}Pa$ at 1 m). The average source level measured by a step of $30^{\circ}$ in vertical was 184.9 (SD: 2.2) dB (re $1{\mu}Pa$ at 1 m). The relative maximum variation width of the source levels in horizontal and in vertical measurement were less than 7.0 dB and 1.0 dB, respectively.

Calculation of the Least Significant Change Value of Bone Densitometry Using a Dual-Energy X-ray Absorptiometry System

  • Han-Kyung Seo;Do-Cheol Choi;Cheol-Min Shim;Jin-Hyeong Jo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.95-98
    • /
    • 2023
  • Purpose: The precision error of a bone density meter reflects the equipment and reproducibility of results by an examiner. Precision error values can be expressed as coefficient of variation (CV), CV%, and root mean square-SD (RMS-SD). The International Society for Clinical Densitometry (ISCD) currently recommends using RMS-SD as the precision error value. When a 95% confidence interval is applied, the least significant change (LSC) value is calculated by multiplying the precision error value by 2.77. Exceeding the LSC value reflects a significant difference in measured bone density. Therefore, the LSC value of a bone density equipment is an essential factor for accurately determining a patient's bone density. Accordingly, we aimed to calculate the LSC value of a bone density meter (Lunar iDXA, GE) and compare it with the value recommended by the ISCD. We also assessed whether the value measured by the iDXA equipment was below the LSC value recommended by ISCD. Material and Methods: The bone densities of the lumbar spine and thighs of 30 participants were measured twice, and the LSC values were calculated using the precision calculation tool provided by the ISCD (http://www.iscd.org). To check the reproducibility of the measurement, patients were asked to completely dismount from the equipment after the first measurement; the patient was then repositioned before proceeding with the second measurement. Results: The LSC values derived using the CV% values recommended by the ISCD were 5.3% for the lumbar spine and 5.0% for the thigh. The LSC values measured using our bone density equipment were 2.47% for the lumbar spine and 1.61% for the thigh. The LSC value using RMS-SD was 0.031 g/cm2 for the lumbar spine and 0.017 g/cm2 for the thigh. Conclusion: that the findings confirm that the CV% value measured using our bone density meter and the LSC value using RMS-SD were maintained very stably. This can be helpful for obtaining accurate measurements during bone density follow-up examinations.

Estimation of EPDM Insulator in Distribution Line Using PO and SO Measurement (PD 및 SD를 이용한 배전용 EPDM애자의 절연성평가)

  • Lim, Jang-Seob;Song, Il-Keun;Lee, Hyung-Gu;Cheon, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.973-975
    • /
    • 1998
  • Many researchers make efforts to develop an effective material with anti-degradation property. Specially, the porcelain type insulator is required exchanging to polymer insulator according to the environmental consideration. In this paper, we have developed the estimation system using the PD & SD testing. Those approach has been very successful applied to the various practical insulator.

  • PDF

SWoT Service Discovery for CoAP-Based Sensor Networks (CoAP 기반 센서네트워크를 위한 SWoT 서비스 탐색)

  • Yu, Myung-han;Kim, Sangkyung
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.9
    • /
    • pp.331-336
    • /
    • 2015
  • On the IoT-based sensor networks, users or sensor nodes must perform a Service Discovery (SD) procedure before access to the wanted service. Current approach uses a center-concentrated Resource Directory (RD) servers or P2P technique, but these can cause a point-of-failure or flooding of SD messages. In this paper, we proposes an improved SWoT SD approach for CoAP-based sensor networks, which integrates Social Web of Things (SWoT) concept to current CoAP-based SD approach that makes up for weak points of existing systems. This new approach can perform a function like a keyword or location-based search originated from SNS, which can enhances the usability. Finally, we implemented a real system to evaluate.

A System of iPG XML creation and transmission based on SD&S (SD&S 기반 iPG XML 생성 및 전송 시스템)

  • Choi, Bong-Kyu;Kim, Tae-Hyun;Jung, Hoe-Kyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.7
    • /
    • pp.1260-1266
    • /
    • 2007
  • The information and communication technology under developing from was time of broadcast and communication Convergence. There is iCOD with representative service of broadcast and communication Convergence. This the superhigh speed Internet about under using is the service which provides information service, the video contents and broadcasting and others with TV. But this service when it searches broadcasting information of different Channel, again must analyze the stream of broadcasting there is a problem point. This thesis hereupon iCOD broadcasting services it searched efficiently from the terminal and in order the fact that it selects from iCOD broadcasting streams SI information about under extracting SD&S base iPG XML documents it created and it transmits with the distant mote cast the method which and it planned it embodied.

Implementation of the Plug & Play Support System Using SOME/IP and SOME/IP-SD (SOME/IP, SOME/IP-SD 를 이용한 Plug & Play 지원 시스템 구현)

  • Woo-Jin Sung;Hye-Min Kim;Sung-Soo Yoon;Sung-Bhin Oh;Jae-Wook Jeon
    • Annual Conference of KIPS
    • /
    • 2024.05a
    • /
    • pp.128-129
    • /
    • 2024
  • SOME/IP-SD 통신 프로토콜을 활용하여 네트워크 시스템의 데이터 전송 효율성을 향상시키고, 서비스 발견 및 동적 서비스 구성을 통해 시스템의 유연성과 확장성을 증대하는 방법을 탐색한다. SOME/IP-SD 는 네트워크 수신자의 요청에 따라 데이터를 전송, 불필요한 데이터 소비를 최소화함으로써 통신 효율을 극대화한다. 또한, Plug & Play 방식을 통해 네트워크의 변경 사항을 자동으로 인식하고 연결하여 서비스 관리 자동화에 기여한다. 이 프로젝트는 Renesas Electronics 의 RA6M3 MCU 보드를 사용하여 e2 studio 개발 환경에서 구현되었으며, 이를 통해 네트워크 관리 간소화 및 차량 시스템의 성능과 안전성 향상에 기여할 것으로 기대된다.

A Study on Tapeless HD Format Editing -Focus on video editing using PMW-EX3 and Avid Media Composer- (테이프리스 기반의 HD포맷 편집에 관한 연구 -PMW-EX3와 Avid Media Composer를 이용한 영상편집 중심으로-)

  • Park, Sung-Dae;Han, Soo-Whan
    • Journal of Digital Contents Society
    • /
    • v.10 no.3
    • /
    • pp.461-468
    • /
    • 2009
  • In a recent year, the broadcasting system has been changed from analogue to digital all over the world, not just in Korea, and Korea aims at accomplishing 100% digital broadcasting by 2013. The HD(High Definition) Video Format, which currently plays a key role in digital broadcasting system, has been gradually extended in the field of broadcasting and movie. Additionally, many kinds of camcoders and editing systems have been rapidly converted into the digital types, and they are supporting to photograph and video editing systems with the various types of image formats such as SD(Standard Definition) format, HD format, 2K, 4K, etc. Tape Video Storage System, which has been usually used in the stage of photographing by this day, is gradually evolving into Tapeless Video Data Storage System. Thus in this study, Video Compression method of HD format photographed by Sony PMW-EX3, one of major tapeless camcoders, is studied and also the way of applying it effectively in Avid Media Composer, a non-linear editing system, is discussed.

  • PDF