• 제목/요약/키워드: scrubbing

검색결과 149건 처리시간 0.019초

Semiempirical model for wet scrubbing of bubble rising in liquid pool of sodium-cooled fast reactor

  • Pradeep, Arjun;Sharma, Anil Kumar
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.849-853
    • /
    • 2018
  • Mechanistic calculations for wet scrubbing of aerosol/vapor from gas bubble rising in liquid pool are essential to safety of sodium-cooled fast reactor. Hence, scrubbing of volatile fission product from mixed gas bubble rising in sodium pool is presented in this study. To understand this phenomenon, a theoretical model has been setup based on classical theories of aerosol/vapor removal from bubble rising through liquid pools. The model simulates pool scrubbing of sodium iodide aerosol and cesium vapor from a rising mixed gas bubble containing xenon as the inert species. The scrubbing of aerosol and vapor are modeled based on deposition mechanisms and Fick's law of diffusion, respectively. Studies were performed to determine the effect of various key parameters on wet scrubbing. It is observed that for higher vapor diffusion coefficient in gas bubble, the scrubbing efficiency is higher. For aerosols, the cut-off size above which the scrubbing efficiency becomes significant was also determined. The study evaluates the retention capability of liquid sodium used in sodium-cooled fast reactor for its safe operation.

과학기술위성 2호 탑재컴퓨터의 메모리 세정 방안 (Memory Scrubbing for On-Board Computer of STSA T-2)

  • 유상문
    • 제어로봇시스템학회논문지
    • /
    • 제13권6호
    • /
    • pp.519-524
    • /
    • 2007
  • The OBC(on-board computer) of a satellite which plays a role of the controller for the satellite should be equipped with preventive measures against transient errors caused by SEU(single event upset). Since memory devices are pretty much susceptible to these transient errors, it is essential to protect memory devices against SFU. A common method exploits an error detection and correction code and additional memory devices, combined with periodic memory scrubbing. This paper proposes an effective memory scrubbing scheme for the OBC of STSAT-2. The memory system of the OBC is briefly mentioned and the reliability of the information stored in the memory system is analyzed. The result of the reliability analysis shows that there exist optimal scrubbing periods achieving the maximum reliability for allowed overall scrubbing overhead and they are dependent on the significance of the information stored. These optimal scrubbing periods from a reliability point of view are derived analytically.

자가 복구 오류 검출 및 정정 회로 적용을 고려한 최적 스크러빙 방안 (An Optimal Scrubbing Scheme for Auto Error Detection & Correction Logic)

  • 류상문
    • 제어로봇시스템학회논문지
    • /
    • 제17권11호
    • /
    • pp.1101-1105
    • /
    • 2011
  • Radiation particles can introduce temporary errors in memory systems. To protect against these errors, so-called soft errors, error detection and correcting codes are used. In addition, scrubbing is applied which is a fundamental technique to avoid the accumulation of soft errors. This paper introduces an optimal scrubbing scheme, which is suitable for a system with auto error detection and correction logic. An auto error detection and correction logic can correct soft errors without CPU's writing operation. The proposed scrubbing scheme leads to maximum reliability by considering both allowable scrubbing load and the periodic accesses to memory by the tasks running in the system.

외과적 손씻기 시간과 소독제에 따른 소독효과 (Effects of Disinfection According to Durations of Surgical Hand Scrub and Type of Disinfectant)

  • 박종남;이미애
    • 기본간호학회지
    • /
    • 제13권2호
    • /
    • pp.208-216
    • /
    • 2006
  • Purpose: This study was done to identify the differences in effectiveness of disinfections for surgical hand scrubbing according to the duration of scrubbing and the type of disinfectant. Method: From June 30 to August 14, 2003, the data were collected from 30 surgical nurses and surgeons in one general hospital in P city, Korea. All participants washed their hands with two different disinfectants and four different scrubbing times, they placed both finger tips on a blood agar plate and using sterile cotton tips microbes were collected from their palms, nails and forearms. Results: The first hypothesis of this study(with same disinfectant, there will be no difference in effect of disinfection in surgical hand scrub among four time groups) was supported. The second hypothesis of this study(with same duration of surgical hand scrub, there will be no difference in effect between two disinfectants) was also supported. Conclusion: There are no differences in effectiveness of disinfection for surgical hand scrubbing according to duration of the scrubbing and the type of disinfectant. So it is concluded that the effectiveness of disinfection depends more on the exactly how the scrubbing is done rather than the duration of scrubbing or the type of disinfectant.

  • PDF

오존세정(洗淨)에 의한 막(膜) 폐색(閉塞) 억제(抑制)에 관한 연구(硏究) (A Study on the Membrane Fouling Control by Ozone-Scrubbing)

  • 김형수;휴지타 켄지
    • 상하수도학회지
    • /
    • 제9권3호
    • /
    • pp.78-87
    • /
    • 1995
  • A study on the fouling control by periodical ozone-scrubbing was conducted in a membrane filtration process for drinking water treatment. Hydrophilic hollow fiber polyethylene membrane with pore size of $0.1{\mu}m$ and its surface area of $0.42m^2$ was used. Dead-End filtration method was selected to obtain high efficiency of energy. Laboratory prepared synthetic raw water with kaolin was used and the membranes were scrubbed by ozone once in an hour and once in two hours. When the duration of ozone scrubbing was increased from 10 seconds to 20 seconds, the rate of membrane fouling was significantly decreased. Although the frequency of ozone-scrubbing was reduced from once in an hour to once in two hours. the effect of fouling control was unchanged. However, ozone-scrubbing was not effective after a membrane was fouled and washed with detergent for reuse. Among several possible working effects of ozone, bactericidal effect was confirmed to be the primary reason of fouling control.

  • PDF

인터리빙 구조를 갖는 메모리의 스크러빙 기법 적용에 따른 신뢰도 해석 (Reliability Analysis of Interleaved Memory with a Scrubbing Technique)

  • 류상문
    • 제어로봇시스템학회논문지
    • /
    • 제20권4호
    • /
    • pp.443-448
    • /
    • 2014
  • Soft errors in memory devices that caused by radiation are the main threat from a reliability point of view. This threat can be commonly overcome with the combination of SEC (Single-Error Correction) codes and scrubbing technique. The interleaving architecture can give memory devices the ability of tolerating these soft errors, especially against multiple-bit soft errors. And the interleaving distance plays a key role in building the tolerance against multiple-bit soft errors. This paper proposes a reliability model of an interleaved memory device which suffers from multiple-bit soft errors and are protected by a combination of SEC code and scrubbing. The proposed model shows how the interleaving distance works to improve the reliability and can be used to make a decision in determining optimal scrubbing technique to meet the demands in reliability.

메모리 소자의 소프트 에러 극복을 위한 최적 스크러빙 방안 (An Optimal Scrubbing Scheme for Protection of Memory Devices against Soft Errors)

  • 류상문
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 추계학술대회
    • /
    • pp.677-680
    • /
    • 2011
  • 우주 방사선은 메모리 시스템에 소프트 에러를 야기할 수 있다. 소프트 에러는 오류 검출 및 정정 코드를 이용하여 극복될 수 있으며, 소프트 에러의 누적을 방지하기 위하여 스크러빙 작업이 병행되어야 한다. 본 논문은 CPU의 쓰기 동작 없이 소프트 에러를 정정할 수 있는 자가 오류 검출 및 정정 회로가 적용된 메모리 시스템에 적용할 수 있는 최적 스크러빙 수행 방안을 제안한다. 제안된 스크러빙 방안은 시스템의 가용한 스크러빙 로드와 시스템에서 실행되는 태스크의 주기적 메모리 접근을 함께 고려하여 최대의 신뢰도를 성취할 수 있도록 하여준다.

  • PDF

Preliminary analyses on decontamination factors during pool scrubbing with bubble size distributions obtained from EPRI experiments

  • Lee, Yoonhee;Cho, Yong Jin;Ryu, Inchul
    • Nuclear Engineering and Technology
    • /
    • 제53권2호
    • /
    • pp.509-521
    • /
    • 2021
  • In this paper, from a review of the size distribution of the bubbles during pool scrubbing obtained from experiments by EPRI, we apply the bubble size distributions to analyses on the decontamination factors of pool scrubbing via I-COSTA (In-Containment Source Term Analysis). We perform sensitivity studies of the bubble size on the various mechanisms of deposition of aerosol particles in pool scrubbing. We also perform sensitivity studies on the size distributions of the bubbles depending on the diameters at the nozzle exit, the molecular weights of non-condensable gases in the carrier gases, and the steam fractions of the carrier gases. We then perform analyses of LACE-ESPANA experiments and compare the numerical ~ results to those from SPARC-90 and experimental results in order to show the effect of the bubble size distributions.

하드웨어 메모리 스크러버 설계

  • 김대영;조창범;강석주;채태병
    • 항공우주기술
    • /
    • 제2권1호
    • /
    • pp.73-79
    • /
    • 2003
  • 대부분의 위성 설계에서 우주 방사선에 의한 메모리 데이터 보호를 위해 오류정정회로를 내장하며, 동시에 오류의 누적을 방지하기 위해 주기적으로 메모리 내용을 읽는 알고리즘을 적용하고 있다. 소프트웨어에 의한 읽기 알고리즘을 적용하는 KOMPSAT 2호기의 경우 메모리 소자에 대한 방사능 영향 시험을 수행하지 않아 1호기에 비해 다소 큰 오류 가능성이 예측되었다. 소프트웨어 알고리즘 변경으로 읽기 작업을 하도록 결정하였으나 하드웨어에 의해 더 빠른 속도로 오류를 정정하도록 하는 방법도 연구되었다. 본 논문은 이러한 연구 결과로서, 최소 1.88분 정도의 주기로 1 Gbits의 메모리 영역을 읽음으로서 하드웨어만으로 메모리 내용을 보존할 수 있는 방법에 대하여 논의하였다.

  • PDF

THERMAL HYDRAULIC ISSUES OF CONTAINMENT FILTERED VENTING SYSTEM FOR A LONG OPERATING TIME

  • Na, Young Su;Ha, Kwang Soon;Park, Rae-Joon;Park, Jong-Hwa;Cho, Song-Won
    • Nuclear Engineering and Technology
    • /
    • 제46권6호
    • /
    • pp.797-802
    • /
    • 2014
  • This study investigated the thermal hydraulic issues in the Containment Filtered Venting System (CFVS) for a long operating time using the MELCOR computer code. The modeling of the CFVS, including the models for pool scrubbing and the filter, was added to the input file for the OPR-1000, and a Station Blackout (SBO) was chosen as an accident scenario. Although depressurization in the containment building as a primary objective of the CFVS was successful, the decontamination feature by scrubbing and filtering in the CFVS for a long operating time could fail by the continuous evaporation of the scrubbing solution. After the operation of the CFVS, the atmosphere temperature in the CFVS became slightly above the water saturation temperature owing to the release of an amount of steam with high temperature from the containment building to the scrubbing solution. Reduced pipe diameters at the inlet and outlet of the CFVS vessel mitigated the evaporation of scrubbing water by controlling the amount of high-temperature steam and the water saturation temperature.