• 제목/요약/키워드: screws

검색결과 651건 처리시간 0.031초

Easy Molding Technique of Methylmethacrylate Implant Using Plaster and Rapid Prototyping Model in Cranioplasty (두개골 성형술에서 석고와 신속조형모델을 이용한 간단한 Methylmethacrylate 삽입물 제작법)

  • Park, Ki Rin;Kim, Yong-Ha;Kim, Tae Gon;Lee, Jun Ho;Ha, Ju Ho
    • Archives of Craniofacial Surgery
    • /
    • 제13권2호
    • /
    • pp.125-129
    • /
    • 2012
  • Purpose: Methylmethacrylate is the most commonly used alloplastic material in cranioplasty. However during the polymerization of methylmethacrylate, a significant exothermic reaction takes place. This reaction may result in thermal injury to the brain tissue and other soft tissues. Also it is difficult to make three-dimensional methylmethacrylate implant that is perfectly matched to the defect during the operation time. We report on the molding technique of methylmethacrylate implant using plaster mold and the rapid prototyping model in cranioplasty. Methods: A 44-year-old male was referred to the department for severe frontal hollowness. He was involved in an automobile accident resulting in large frontal bone defect with irregular margin. The preformed patient-specific methylmethacrylate implant was made using plaster mold and the rapid prototyping model before the operative day. The methylmethacrylate implant was placed in the frontal defect and rigidly fixed with miniplates and screws on the operative day. Results: The operation was performed in an hour. In the 6 months follow-up period, there were no complications. Patient was satisfied with the results of cranioplasty. Conclusion: Safe cranioplasty was performed with the preformed patient-specific methylmethacrylate implant using plaster mold and the rapid prototyping model. The result of this method was satisfactory, aesthetically and functionally.

HISTOLOGIC STUDY OF VARIOUS DENTAL IMPLANT-TISSUE INTERFACE (수종의 치근형 골내매식체와 조직간의 반응에 관한 조직학적 연구)

  • Lee, Ho-Young;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제28권1호
    • /
    • pp.7-23
    • /
    • 1990
  • The success or failure of endosseous dental implants is related to the cellular activity at the implant surface. Success seems to be associated with the enclosure of the implant in a non-inflammed connective tissue or the formation of a direct bone implant interface. The purpose of this study was to examine the tissue reactions to the various implants at the submergible state in dog mandible. The $Br\"{a}nemark$, Core-Vent, Intergral, Bone spiral were selected for evaluation and also the Kimplant, Nephrite were used for the experimental study. After 4 months the animals were sacrificed. The interface zone between bone and implant was investigated using x-rays, light microscope, scanning electron microscope, transmission electron microscope. The following results were obtained from this study. 1. $Br\"{a}nemark$, Core-Vent, Kimplant, Integral showed no mobility and bone growth over the healing screws of the implants. Histologically most of the implant surface were covered by remodelled lamellar bone, and partly by a cellular layer or the thin fibrous tissue layer. 2. The Bone spiral showed no mobility and partially radiolucent line around the implant. The upper part of the implant was surrounded by a thin fibrous connective tissue and the middle, apical part of it were contacted with bone directly. 3. The Nephrite implant showed severe mobility and a radiolucent line around the implant. Histologically it showed mild inflammation and was surrounded by a fibrous connective tissue. 4. Scanning electron microscope showed that there was no amorphous ground substance in the Nephrite implant but the formation of ground substance over the collagen filaments in other implants. 5. Transmission electron microscope showed that collagen filaments were approached irregularly to the surface of all implants and in the $Br\"{a}nemark$, Core-Vent, Kimplant, Integral there was amorphous layer between the implant and the collagen filaments. It seemed to be ground substances.

  • PDF

Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study

  • Kim, Sung-Jun;Son, KeunBaDa;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.388-394
    • /
    • 2018
  • PURPOSE. To measure axial displacement of different implant-abutment connection types and materials during screw tightening at the recommended torque by using a contact scanner for two-dimensional (2D) and three-dimensional (3D) analyses. MATERIALS AND METHODS. Twenty models of missing mandibular left second premolars were 3D-printed and implant fixtures were placed at the same position by using a surgical guide. External and internal fixtures were used. Three implant-abutment internal connection (INT) types and one implant-abutment external connection (EXT) type were prepared. Two of the INT types used titanium abutment and zirconia abutment; the other INT type was a customized abutment, fabricated by using a computer-controlled milling machine. The EXT type used titanium abutment. Screws were tightened at $10N{\cdot}cm$, simulating hand tightening, and then at the manufacturers' recommended torque ($30N{\cdot}cm$) 10 min later. Abutments and adjacent teeth were subsequently scanned with a contact scanner for 2D and 3D analyses using a 3D inspection software. RESULTS. Significant differences were observed in axial displacement according to the type of implant-abutment connection (P<.001). Vertical displacement of abutments was greater than overall displacement, and significant differences in vertical and overall displacement were observed among the four connection types (P<.05). CONCLUSION. Displacement according to connection type and material should be considered in choosing an implant abutment. When adjusting a prosthesis, tightening the screw at the manufacturers' recommended torque is advisable, rather than the level of hand tightening.

Displacement of scan body during screw tightening: A comparative in vitro study

  • Kim, JungHan;Son, KeunBaDa;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권5호
    • /
    • pp.307-315
    • /
    • 2020
  • PURPOSE. The purpose of this study was to evaluate the occurrence of displacement while tightening the screw of scan bodies, which were compared according to the material type. MATERIALS AND METHODS. Three types of scan bodies whose base regions were made up of polyether ether ketone (PEEK) material [Straumann Group, Dentium Group, and Myfit (PEEK) Group] and another scan body whose base region was made up of titanium material [Myfit (Metal) Group] were used (15 per group). The reference model was fabricated by aligning the scan body library on the central axis of the implant, and moving this position by the resin model. The screws of the scan bodies were tightened to the implant fixture with torques of 5 Ncm, 10 Ncm, and a hand tightening torque. After the application of the torque, the scan bodies were scanned using a laboratory scanner. To evaluate the vertical, horizontal, and 3-dimensional (3D) displacements, a 3D inspection software program was used. To examine the difference among groups, one-way analysis of variance and Tukey's HSD post hoc test were used (α=.05). RESULTS. There were significant differences in 3D, vertical, and horizontal displacements among the different types of scan bodies (P<.001). There was a significantly lower displacement in the Straumann group than in the Myfit (PEEK) and Dentium groups (P<.05). CONCLUSION. The horizontal displacement in all groups was less than 10 ㎛. With the hand tightening torque, a high vertical displacement of over 100 ㎛ occurred in PEEK scan bodies (Myfit and Dentium). Therefore, it is recommended to apply a tightening torque of 5 Ncm instead of a hand tightening torque.

Postoperative Non-Pathological Fever Following Posterior Cervical Fusion Surgery : Is Laminoplasty a Better Preventive Method than Laminectomy?

  • Lee, Subum;Jung, Sang Ku;Kim, Hong Bum;Roh, Sung Woo;Jeon, Sang Ryong;Park, Jin Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권4호
    • /
    • pp.487-494
    • /
    • 2020
  • Objective : To analyze the incidence and characteristics of delayed postoperative fever in posterior cervical fusion using cervical pedicle screws (CPS). Methods : This study analyzed 119 patients who underwent posterior cervical fusion surgery using CPS. Delayed fever was defined as no fever for the first 3 postoperative days, followed by an ear temperature ≥38℃ on postoperative day 4 and subsequent days. Patient age, sex, diagnosis, laminectomy, surgical level, revision status, body mass index, underlying medical disease, surgical duration, and transfusion status were retrospectively reviewed. Results : Of 119 patients, seven were excluded due to surgical site infection, spondylitis, pneumonia, or surgical level that included the thoracic spine. Of the 112 included patients, 28 (25%) were febrile and 84 (75%) were afebrile. Multivariate logistic regression analysis showed that laminectomy was a statistically significant risk factor for postoperative non-pathological fever (odds ratio, 10.251; p=0.000). In contrast, trauma or tumor surgery and underlying medical disease were not significant risk factors for fever. Conclusion : Patients who develop delayed fever 4 days after posterior cervical fusion surgery using CPS are more likely to have non-pathologic fever than surgical site infection. Laminectomy is a significant risk factor for non-pathologic fever.

THE EFFECT OF GINGIVAL GEL ON PERIODONTIUM IN MANDIBULAR FRACTURE PATIENTS APPLIED BY ARCH BAR (선부자를 적용한 하악골 골절환자의 치주조직에 기능성 치약이 미치는 영향)

  • Kim, Sun-Min;Kim, Kyung-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제35권2호
    • /
    • pp.125-130
    • /
    • 2009
  • For many years, intermaxillary fixation using arch bar has been operated in treatment of mandibular fracture patients. But it has many complications including injury of operators and assistants cause by wire, inflammation of periodontium. For that reasons alternatives are required; osteosynthesis technique using mini plate, intermaxillary fixation using IMF screws have been available. Treatment by arch bar fixation, however, is still valuable to treat craniomaxillary fracture patients. The purpose of this study is to know effect arch bar on periodontium and influence gingival gel on periodontium applied by arch bar. 40 mandibular fracture patients are monitored. 30 patients were applied by arch bar, 10 patients were not. And the former were classified by 3 categories; Nano vitamin and Mastic gel were applied to 10 patients respectively and any gingival gel was not used to 10 patients. Clinical attachment level, bleeding on probing and periodontal depth of each group were measured and compared before operation and on 2 weeks and 6 weeks after operation. Mann-Whitney U test was used to analyze result which leads to this conclusion. 1. Whether arch bar is applied or not, treatment of mandlbular fracture gave rise to gingivitis, but 6 weeks after operation, gingivitis is restored to the same level as the state before operation. 2. More severe gingivitis appeared when arch bar is applied to mandibular fracture than when it is not. 3. Both gingival gel used in this study can reduce gingivitis which can be caused by arch bar. 4. In this study, Mastic gel is more effective for prevent gingival inflammation cause by arch bar than nano vitamin. In regard to this result, gingivitis is considered to be available because it is reversible and does not induce periodontal disease. Gingival gel is regarded to be helpful for patients applied by arch bar to feel less discomfort.

Anterior Dislodgement of a Fusion Cage after Transforaminal Lumbar Interbody Fusion for the Treatment of Isthmic Spondylolisthesis

  • Oh, Hyeong Seok;Lee, Sang-Ho;Hong, Soon-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • 제54권2호
    • /
    • pp.128-131
    • /
    • 2013
  • Transforaminal lumbar interbody fusion (TLIF) is commonly used procedure for spinal fusion. However, there are no reports describing anterior cage dislodgement after surgery. This report is a rare case of anterior dislodgement of fusion cage after TLIF for the treatment of isthmic spondylolisthesis with lumbosacral transitional vertebra (LSTV). A 51-year-old man underwent TLIF at L4-5 with posterior instrumentation for the treatment of grade 1 isthmic spondylolisthesis with LSTV. At 7 weeks postoperatively, imaging studies demonstrated that banana-shaped cage migrated anteriorly and anterolisthesis recurred at the index level with pseudoarthrosis. The cage was removed and exchanged by new cage through anterior approach, and screws were replaced with larger size ones and cement augmentation was added. At postoperative 2 days of revision surgery, computed tomography (CT) showed fracture on lateral pedicle and body wall of L5 vertebra. He underwent surgery again for paraspinal decompression at L4-5 and extension of instrumentation to S1 vertebra. His back and leg pains improved significantly after final revision surgery and symptom relief was maintained during follow-up period. At 6 months follow-up, CT images showed solid fusion at L4-5 level. Careful cage selection for TLIF must be done for treatment of spondylolisthesis accompanied with deformed LSTV, especially when reduction will be attempted. Banana-shaped cage should be positioned anteriorly, but anterior dislodgement of cage and reduction failure may occur in case of a highly unstable spine. Revision surgery for the treatment of an anteriorly dislodged cage may be effectively performed using an anterior approach.

Risk Factors for Delayed Hinge Fracture after Plate-Augmented Cervical Open-Door Laminoplasty

  • Hur, Junseok W.;Park, Youn-Kwan;Kim, Bum-Joon;Moon, Hong-Joo;Kim, Joo-Han
    • Journal of Korean Neurosurgical Society
    • /
    • 제59권4호
    • /
    • pp.368-373
    • /
    • 2016
  • Objective : Delayed hinge fracture (HF) that develops after cervical open door laminoplasty can be a source of postoperative complications such as axial pain. However, risk factors related to this complication remain unclear. We performed a retrospective clinical series to determine risk factors for delayed HF following plate-only open-door cervical laminoplasty. Methods : Patients who underwent plate-only open-door laminoplasty and had available postoperative computed tomography (CT) scans (80 patients with 270 laminae) were enrolled. Hinge status, hinge gutter location, open location, hinge width, number of screws used, operation level, and open angle were observed in the CT to determine radiographic outcome. Demographic data were collected as well. Radiographic and clinical parameters were analyzed using univariate and multivariate logistic regression analysis to determine the risk factors for HF. Results : Univariate logistic regression analysis results indicated poor initial hinge status, medially placed hinge gutter, double screw fixation on the elevated lamina, upper surgical level, and wide open angle as predictors for HF (p<0.05). Initial hinge status seemed to be the most powerful risk factor for HF (p=0.000) and thus was collinear with other variables. Therefore, multivariate logistic regression analysis was performed excluding initial hinge status, and the results indicated that medially placed hinge gutter, double screw fixation on the elevated lamina, and upper surgical level were risk factors for HF after adjustment for other confounding factors. Conclusion : To prevent HF and to draw a successful postoperative outcome after cervical laminoplasty, surgical and clinical precautions should be considered.

A COMPARISON OF ACCURACY BETWEEN FIXTURE IMPRESSION AND ABUTMENT IMPRESSION FOR DENTAL IMPLANTS (치과 임플랜트용 고정체 인상법과 지대원주 인상법간의 정확성 비교)

  • Choi, Hyun-Sik;Yim, Soon-Ho;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제35권4호
    • /
    • pp.662-673
    • /
    • 1997
  • The purpose of this study was to compare the accuracy between future impression and abutment impression using strain gauges. The master model used in this study was a partially edentulous mandibular metal cast with two fixture analogs on both sides. On the left, two future analogs were parallel, whereas right side, posterior future analog exhibiting a 15-degree lingual inclination. From master cast, 10 impressions were made for each of the three impression methods. The master frameworks was fabricated on the master model, and two-element strain gauge was attached to a master framework. The master framework was seated on each cast, and gold screws were tightened to 10 Ncm using a torque controller AI-1600 strain measurement system was used for strain measuring. Impression methods studied were : Group 1:abutment impression Group 2:fixture impression Group 3:combined impression (anterior:fixture impression, posterior:abutment impression) The results were as followed. 1. The strain values on X-axis and Y-axis according to the three impression methods showed no significant difference. 2. The strain values on parallel and angulated groups according to the three impression methods showed no significant difference. 3. The parallel group exhibited significantly higher accuracy in adaptation than angulated group for all experimental groups (p<0.05). In conclusion, it is considered that accuracy of implant prostheses is more affected by implant angulation than impression methods.

  • PDF

Fixation with Bioabsorbable Polylactide Plate and Screws for the Treatment of the Ankle Fractures (생체 흡수성 판과 나사못을 이용한 족근 관절 골절의 치료)

  • Kwon, Duck-Joo;Lee, Yong-Beom;Shin, Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • 제13권1호
    • /
    • pp.80-84
    • /
    • 2009
  • Purpose: The purpose of this article is to assess the efficacy of a bioabsorbable polylactide (PLA) plate and screw for treating injuries of ankle fractures. Materials and Methods: 24 patients who underwent an open reduction and internal fixation operation for ankle fractures from July 2005 to March 2007 were enrolled into the study. There were 15 men and 9 women. The average age of the patients was 44 years and the average follow-up period was 16 years and two months (16.2 months). All cases were divided into low grade fracture patient (11) who belongs in type A and B of Danis-Weber classification and high grade fracture patient (13) who belongs in type C1, C2 of Danis-Weber classification, and each groups were analyzed by clinical (Meyer score) and radiological finding at the time of their last follow-up evaluation. Results: The clinical results according to Meyer scoring system, showed that all patient with low grade fracture had good to excellent result, but only 54% of patient with high grade fracture had good to excellent result. According to Cedell's radiologic finding, there were 91% cases above fair in low grade fracture. But there were 62% of patient above fair result in high grade fracture, the reduction losses were seen in 38% of patient with high grade fracture. Conclusion: Bioabsorbable PLA plate and screw is good internal fixation device which doesn't have additional operation for removal of implant because of slow absorption within the human body. It showed sufficient strength for acquisition and maintenance of reduction in low grade fracture, but need attention to use because of many cases of reduction loss in high grade fracture. So, it seems to be safe and effective when used in heeling of low grade fracture under considering about type of fracture sufficiently.

  • PDF