• Title/Summary/Keyword: screws

Search Result 647, Processing Time 0.024 seconds

Unilateral Posterior Atlantoaxial Transarticular Screw Fixation in Patients with Atlantoaxial Instability : Comparison with Bilateral Method

  • Hue, Yun-Hee;Chun, Hyoung-Joon;Yi, Hyeong-Joong;Oh, Seong-Hoon;Oh, Suck-Jun;Ko, Yong
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.3
    • /
    • pp.164-168
    • /
    • 2009
  • Objective : Bilateral C1-2 transarticular screw fixation (TAF) with interspinous wiring has been the best treatment for atlantoaxial instability (AAI). However, several factors may disturb satisfactory placement of bilateral screws. This study evaluates the usefulness of unilateral TAF when bilateral TAF is not available. Methods : Between January 2003 and December 2007, TAF was performed in 54 patients with AAI. Preoperative studies including cervical x-ray, three dimensional computed tomogram, CT angiogram, and magnetic resonance image were checked. The atlanto-dental interval (ADI) was measured in preoperative period, immediate postoperatively, and postoperative 1, 3 and 6 months. Results : Unilateral TAF was performed in 27 patients (50%). The causes of unilateral TAF were anomalous course of vertebral artery in 20 patients (74%), severe degenerative arthritis in 3 (11%), fracture of C1 in 2, hemangioblastoma in one, and screw malposition in one. The mean ADI in unilateral group was measured as 2.63 mm in immediate postoperatively, 2.61 mm in 1 month, 2.64 mm in 3 months and 2.61 mm in 6 months postoperatively. The mean ADI of bilateral group was also measured as following; 2.76 mm in immediate postoperative, 2.71 mm in 1 month, 2.73 mm in 3 months, 2.73 mm in 6 months postoperatively. Comparison of ADI measurement showed no significant difference in both groups, and moreover fusion rate was 100% in bilateral and 96.3% in unilateral group (p=0.317). Conclusion : Even though bilateral TAF is best option for AAI in biomechanical perspectives, unilateral screw fixation also can be a useful alternative in otherwise dangerous or infeasible cases through bilateral screw placement.

Lateral Lumbar Interbody Fusion and in Situ Screw Fixation for Rostral Adjacent Segment Stenosis of the Lumbar Spine

  • Choi, Young Hoon;Kwon, Shin Won;Moon, Jung Hyeon;Kim, Chi Heon;Chung, Chun Kee;Park, Sung Bae;Heo, Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.6
    • /
    • pp.755-762
    • /
    • 2017
  • Objective : The purpose of this study is to describe the detailed surgical technique and short-term clinical and radiological outcomes of lateral lumbar interbody fusion (LLIF) and in situ lateral screw fixation using a conventional minimally invasive screw fixation system (MISF) for revision surgery to treat rostral lumbar adjacent segment disease. Methods : The medical and radiological records were retrospectively reviewed. The surgery was indicated in 10 consecutive patients with rostral adjacent segment stenosis and instability. After the insertion of the interbody cage, lateral screws were inserted into the cranial and caudal vertebra using the MISF through the same LLIF trajectory. The radiological and clinical outcomes were assessed preoperatively and at 1, 3, 6, and 12 months postoperatively. Results : The median follow-up period was 13 months (range, 3-48 months). Transient sensory changes in the left anterior thigh occurred in 3 patients, and 1 patient experienced subjective weakness; however, these symptoms normalized within 1 week. Back and leg pain were significantly improved (p<0.05). In the radiological analysis, both the segmental angle at the operated segment and anterior disc height were significantly increased. At 6 months postoperatively, solid bony fusion was confirmed in 7 patients. Subsidence and mechanical failure did not occur in any patients. Conclusion : This study demonstrates that LLIF and in situ lateral screw fixation may be an alternative surgical option for rostral lumbar adjacent segment disease.

Fatigue Characterization of Glass/Polypropylene Composite Bone Plates Locked with an Artificial Tibia under Moisture Environment (인조골에 체결된 유리섬유/폴리프로필렌 복합재료 고정판의 수분 환경 피로 특성)

  • Han, Min-Gu;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.26 no.5
    • /
    • pp.328-333
    • /
    • 2013
  • In this study, bone plate made of glass/polypropylene composite material which was applied to an artificial bone was tested to check the service ability under fatigue loading. To check serviceability of composite bone plates fatigue test was carried out considering changes in the moisture absorption rate, locking position of screws and loading condition. Test results showed that all the tested specimens had the fatigue life more than one million cycles which was much higher fatigue life than the expected value of 650,000 cycles. Screw position was not critical impact on the deformation of the fracture site. In this paper, the mechanical performance of the glass/polypropylene composite was verified by fatigue test under various water absorption conditions, and this result may give useful information on the design of composite bone plate.

SURGICAL REPOSITIONING OF THE EXTRUDED DENTO-ALVEOLAR SEGMENTS BY THE SINGLE-STAGE POSTERIOR MAXILLARY SEGMENTAL OSTEOTOMY (하악구치부 보철공간을 위한 상악구치부의 분절골절단 및 상방 정위)

  • Kim, Myung-Rae;Kim, Choong;Kim, Hyung-Sub
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.4
    • /
    • pp.338-347
    • /
    • 2001
  • Purpose: This is to review the cases of posterior maxillary segmental osteotomies to regain the interarch spaces for dental implants in the posterior mandible. Materials & Methods: Seven patients who presented with alveolar extrusion of upper posterior molars underwent segmental osteotomies by single-stage Kufner's buccal approach under the intravenous sedation and local anesthesia. The posterior maxillary cento-alveolar segments were repositioned upward using pre-fabricated palato-occlusal resin splints and immobilized with osteosynthesis microplates and screws. Dental implants were installated simultaneously. The regained spaces, tooth vitality, periodontal healing, relapse, tenderness on function, and complications including maxillary sinus involvements were evaluated periodically for over one year after the surgeries. Results: The single-tage procedures were completed within 80 minutes without any surgical complications. The posterior maxillary segments were repositioned upward to regain the interarch spaces ranging from 2.5 to 5.5mm. All teeth involved in the procedures keep their vitalities. The repositioned segments were maintained showing neither evidence of periodontal break-down nor tenderness to function. One patient whose segments had not been immobilized by osteosynthesis plate resulted in 2mm down-ward relapse in post-operative 8 months. A case of postoperative nasal bleeding from the posterior-lateral wall resulted in oroantral fistula and chronic maxillary sinusitis later. Conclusion: The extruded dento-alveolar segments of the posterior maxilla were repositioned properly by Kufner's one-stage segmental osteotomies. One microplate can be of help to keep the position until the osseous healing enough to support the masticatory force.

  • PDF

Treatment of extensive comminuted mandibular fracture between both mandibular angles with bilateral condylar fractures using a reconstruction plate: a case report

  • Lee, Kwonwoo;Yoon, Kyuho;Park, Kwan-Soo;Cheong, Jeongkwon;Shin, Jaemyung;Bae, Jungho;Ko, Inchan;Park, Hyungkoo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.3
    • /
    • pp.135-139
    • /
    • 2014
  • This following case report describes the open reduction, internal fixation and the reconstruction of an extensive comminuted mandibular fracture with bilateral condylar fractures in a 19-year-old male patient with an intellectual disability and autistic disorder. He suffered fall trauma, resulting in shattered bony fragments of the alveolus and mandibular body between both mandibular rami, the fracture of both condyles and the avulsion or dislocation of every posterior tooth of the mandible. The patient underwent open reduction and internal fixation between both mandibular rami using a reconstruction plate, open reduction and internal fixation of the shattered fragments using miniplates and screws, and the closed reduction of the bilateral condylar fractures.

The Result of Mandible Fracture Fixations with Biodegradable Materials (생체흡수성 재료를 이용한 하악골절 치료의 결과)

  • Wang, Jae Kwon;Eun, Seok Chan;Heo, Chan Yeong;Baek, Rong Min;Minn, Kyung Won
    • Archives of Craniofacial Surgery
    • /
    • v.9 no.2
    • /
    • pp.45-50
    • /
    • 2008
  • Purpose: Traditionally, titanium miniplate has been used for rigid fixation of mandible fractures. However, the limitations of metal plate have been reported such as hypersensitivity, interference with the cranio-facial growth of growing child, secondary bone resorption around the plate, foreign body reaction, declination of primary callus formation, and bone atrophy, and so forth. Recently, biodegradable miniplate has been introduced and used as an alternative to the metal plate despite of its lower strength. This study evaluated the usefulness and stability of biodegradable plate and screw for treatment of mandible fractures. Methods: In this study, 61 patients(92 areas) diagnosed as mandible fracture in the last 2 years have been reviewed. We used titanium plate and screw in 32 patients, and biodegradable plate and screw($INION^{(R)}$) in 29 patients. Stability of plates and screws, bony healing process and its side effects were observed by clinical and radiographic assessment. Results: In the titanium material group, one of malocclusion, two of mouth opening limitation, three of pain, three of palpation were shown. The plate of six patients involved in these complications were removed. In the biodegradable group, two of mouth opening limitation, two of pain, one of localized wound infection were shown and one plate was removed secondarily. Conclusion: There was no statistical difference between two groups in bony healing and complication rates. Biodegradable implants show efficient stability during initial bone healing and low side effects in long-term follow up periods.

Internal Fixation of Medpor® Implant for Prevention of Enophthalmos in Posteriorly Extended Orbital Floor Fracture (후방까지 연장된 안와하벽골절에서 안구함몰 예방을 위한 Medpor® 내고정술)

  • Suhk, Jeong Hoon;Ji, So Young;Kim, Tae Bum;Yang, Wan Suk
    • Archives of Craniofacial Surgery
    • /
    • v.9 no.2
    • /
    • pp.55-61
    • /
    • 2008
  • Purpose: The purpose of this study is to evaluate the effectiveness of internal fixation method of $Medpor^{(R)}$ implant with $BioSorb^{TM}FX$ screw which is used for prevention of enophthalmos in posteriorly extended large orbital floor fracture. Methods: From Jun. 1997 to Dec. 2007, 21 patients who were diagnosed with posteriorly extended large orbital floor fractures were classified into two groups. One group(n=11) had undergone reduction surgery with regular $Medpor^{(R)}$ sheets without any fixation method, while the other group(n=10) had their $Medpor^{(R)}$ sheets fixed with the $BioSorb^{TM}FX$ screws. The two groups were evaluated by comparison of their enophthalmos degree and effectiveness. Results: In the non-fixation group, six patients had enophthalmos preoperatively and three of them showed persistent enophthalmos postoperatively. In postoperative CT examination, displacement of $Medpor^{(R)}$ implant with soft tissue impaction into maxillary sinus was observed in the patients. In the screw fixation group, three patients had enophthalmos preoperatively, but none of them suffer from complication such as residual enophthalmos, soft tissue impaction, muscle entrapment or optic nerve compression postoperatively. Conclusion: Internal fixation method of $Medpor^{(R)}$ implant with $BioSorb^{TM}FX$ screw on the medial surface of orbital floor provides firm stabilization of implants and surrounding soft tissues and can be an effective option especially when postoperative implant displacement or malposition was expected.

A Study of mechanical properties of oxide layer removed Co-Cr-Mo abutments

  • Ryu, Jae-ho;Huh, Jung-Bo;Ro, Jung-Hoon;Yun, Mi-Jung;Jeong, Chang-Mo
    • The Journal of the Korean dental association
    • /
    • v.53 no.11
    • /
    • pp.804-816
    • /
    • 2015
  • PURPOSE: The aim of this study was to evaluate the influence of the oxide layer removal process in the Co-Cr-Mo (CCM) abutment after casting procedure on the prosthesis settlement and screw stability. MATERIALS AND METHODS: CCM abutments of four different interface conditions (CCM-M; machined, CCM-O; oxide layer formed, CCM-B; blasted, CCM-P; polished after blasted) and gold abutment (Gold-C; Cast with type III Gold alloy) were used. The initial settling values of abutments were evaluated according to the difference of implant-abutment length when the tightening torques were applied at 5 Ncm and 30 Ncm, and the settling values of abutments caused by loading were evaluated according to the difference of implant-abutment length before and after loading with 250 N, 100000 cycle. The loss ratios of removal torque for abutment screws were evaluated according to the difference in value of removal torques under 30 Ncm tightening torque applied before and after cyclic loading. RESULTS: The CCM-P and CCM-B group showed a higher initial settling value compared with the Gold-C group (P<.05), while the Gold-C group showed the highest settling values caused by loading (P<.05) and no significant differences were observed for between CCM groups (P>.05). The loss ratio of removal torque values for the CCM-B, CCM-P groups did not differ significantly from that of the Gold-C group (P>.05). CONCLUSION: Even though the oxide layer was removed by different methods, CCM abutment with internal conical connection structure showed lower abutment settling and similar screw loosening after cyclic loading compared with gold abutment.

Mandible Reconstruction with 3D Virtual Planning

  • Woo, Taeyong;Kraeima, Joep;Kim, Yong Oock;Kim, Young Seok;Roh, Tai Suk;Lew, Dae Hyun;Yun, In Sik
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.2
    • /
    • pp.90-93
    • /
    • 2015
  • The fibula free flap has now become the most reliable and frequently used option for mandible reconstruction. Recently, three dimensional images and printing technologies are applied to mandibular reconstruction. We introduce our recent experience of mandibular reconstruction using three dimensionally planned fibula free flap in a patient with gunshot injury. The defect was virtually reconstructed with three-dimensional image. Because bone fragments are dislocated from original position, relocation was necessary. Fragments are virtually relocated to original position using mirror image of unaffected right side of the mandible. A medical rapid prototyping (MRP) model and cutting guide was made with 3D printer. Titanium reconstruction plate was adapted to the MRP model manually. 7 cm-sized fibula bone flap was designed on left lower leg. After dissection, proximal and distal margin of fibula flap was osteotomized by using three dimensional cutting guide. Segmentation was also done as planned. The fibula bone flap was attached to the inner side of the prebent reconstruction plate and fixed with screws. Postoperative evaluation was done by comparison between preoperative planning and surgical outcome. Although dislocated condyle is still not in ideal position, we can see that reconstruction was done as planned.

Limited Internal Fixation and External Fixation of the Pilon Fractures (제한적 내고정술 및 외고정술을 이용한 경골 Pilon 골절의 치료)

  • Choi, Won-Tae;Eom, Doo-Seob;Lim, Young-Taeg;Yoo, Hyun-Jong;Jeong, Sang-Don
    • Journal of Korean Foot and Ankle Society
    • /
    • v.3 no.1
    • /
    • pp.26-32
    • /
    • 1999
  • Fractures of the tibial pilon are the severe injuries to the ankle joint resulted from axial compression, shear and/or rotational forces. The pilon fractures have been difficult in management due to the severe comminution of articular surface and frequent soft tissue problem. Among many treatment options, limited internal fixation of the tibia with long screws and multiple pins augmented with external fixation or casting provide adequate stabilization without soft tissue compromise. Among the patients of pilon fracture admitted to our hospital from March 1993 to March 1997 who treated by limited internal fixation and external fixation or casting, 25cases are included who could be follow up for more than 10months. According to Ruedi and Allgower, typeI 3cases, typeII 14cases, typeIII 8cases. The authors analyzed the clinical and radiological results of the tibial pilon fractures according to Magnusson. The results were as follow. 1. 10cases at Ruedi-Allgower typeII were obtained above fair and 5cases at Ruedi-Allgower typeIII were obtained above fair. 2. The postoperative complications were skin problem(3cases) and infection(2cases), which were treated by antibiotics and flap surgery.

  • PDF