• 제목/요약/키워드: screws

검색결과 646건 처리시간 0.025초

Effect of cyclic loading and retightening on reverse torque value in external and internal implants

  • Cho, Woong-Rae;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.288-293
    • /
    • 2015
  • PURPOSE. The aim of this study was to evaluate the effect of cyclic loading and screw retightening on reverse torque value (RTV) in external and internal type implants. MATERIALS AND METHODS. Cement-retained abutments were connected with 30 Ncm torque to external and internal type implants. Experimental groups were classified according to implant connection type and retightening/loading protocol. In groups with no retightening, RTV was evaluated after cyclic loading for 100,000 cycles. In groups with retightening, RTV was measured after 3, 10, 100 cycles as well as every 20,000 cycles until 100,000 cycles of loading. RESULTS. Every group showed decreased RTV after cyclic loading. Before and after cyclic loading, external type implants had significantly higher RTVs than internal type implants. In external type implants, retightening did not affect the decrease in RTV. In contrast, retightening 5 times and retightening after 10 cycles of dynamic loading was effective for maintaining RTV in internal type implants. CONCLUSION. Retightening of screws is more effective in internal type implants than external type implants. Retightening of screws is recommended in the early stage of functional loading.

생체흡수성 나사못을 이용한 원위경비관절 이개의 치료 (Treatment of syndesmotic injury of ankle with bioabsorbable screw)

  • 강재도;김광열;김형천;임문섭;김진형;김성훈
    • 대한족부족관절학회지
    • /
    • 제7권1호
    • /
    • pp.88-94
    • /
    • 2003
  • Purpose: Bioabsorbable screws are used to fix the syndesmotic injury of ankle because of no need for additional operation to remove it. The purpose of this study is to assess the efficacy of polylevolactic acid (PLLA) screws of in the treatment of the syndesmotic injury of ankle. Materials and Methods: Eight patients of the syndesmotic injury of ankle with malleolar fracture were evaluated in this study. They were managed with plate and screw fixation for malleolar fracture and polylevolactic acid screw fixation for syndesmotic injury, followed by plaster splinting for 6 weeks. Clinical and radiographic evaluation were done and functional scores were assessed. Results: In all cases, malleolar fractures were healed without problematic widening of syndesmosis. There were no sinus tract formation and no wound complication. Of eight patients, five had excellent results and three had good results. Conclusion: We conclude that polylevolactic acid screw is good material for fixation of the syndesmotic injury of ankle.

  • PDF

Acutrak 나사를 이용한 족관절 내과 골절의 치료 (Surgical Treatment of Using Acutrak Screw for Ankle Medial Malleolar Fracture)

  • 김광열;김형천;안수한;윤형조;조성준
    • 대한족부족관절학회지
    • /
    • 제14권1호
    • /
    • pp.84-89
    • /
    • 2010
  • Purpose: The purpose of this study is to evaluate the clinical and radiologic results of using Acutrak screws for treating ankle medial malleolar fracture. Materials and Methods: We reviewed 38 cases of ankle medial malleolar fracture treated with Acutrak screws from February 2005 to May 2008. Results: In clinical result, there were 30 exellent cases, 7 good cases, 1 fair case. In radiologic result, there is no case with reduction loss. Average union time is 10.5 weeks. Conclusion: We conclude that Acutrak screw fixation is a useful method for ankle medial malleolar fracture, there are many advantages in accurate anatomical reduction, small incision, short operative time.

Pedicle screws에 의해 CT에 생성되는 metal artifact를 최소화하는 알고리즘 개발 (A new algorithm for minimization of metal artifact made on CT by pedicle screws)

  • 이제범;염진섭;김남국;이동혁;김종효;김영호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.279-280
    • /
    • 1998
  • A new algorithm is developed that can reduce the metal artifact on CT caused by pedicle screws. Metal artifact has been recognized as a major problem in precise reading of CT images. In particular, spine surgeons have been bothered with the artifact appearing on CT taken after pedicle screw insertion. To reduce the artifact, our new algorithm first finds the center line from CT images, and then overlays an exact size screw image on the CT. The exact screw is obtained from an actual design specifications of screw, and the CT images are processed to maximize bone margins while minimizing screw images through adjusting the window width and level. 실험 결과 단순한 Window W/L 조절로는 해결되지 않는군요. This algorithm provides spine surgeons with more accurate CT images and thus better interpretation of CT to ascertain the success or failure of pedicle screw insertion.

  • PDF

금형설계 변수에 따른 마이크로 티타늄 나사 전조공정의 성형 특성 고찰 (An Investigation of Thread Rolling Characteristics of Titanium Micro-Screws according to Die Design Parameters)

  • 이지은;김종봉;박근
    • 한국정밀공학회지
    • /
    • 제34권2호
    • /
    • pp.89-94
    • /
    • 2017
  • Micro-screws can be defined by their outer diameter of generally less than 1 mm. They are manufactured by head forging and thread rolling processes. In this study, the thread rolling process was numerically analyzed for a micro-screw with a diameter and pitch of 0.8 and 0.2 mm, respectively. Through finite element (FE) analysis, the effects of two design parameters (die gap and chamfer height) on the dimensional accuracy were investigated. Three combinations of chamfer heights were chosen first and the corresponding die gap candidates selected by geometric calculation. FE analyses were performed for each combination and their results indicated that the concave chamfer height should be less than 0.3 mm, while a 10 ?m difference in the die gap might cause degeneration in dimensional accuracy. These results conclude that ultra-high accuracy is required in die fabrication and assemblies to ensure dimensional accuracy in micro-screw manufacturing.

국내산 목재에 대한 나사못 직경, 관입길이 및 목재비중에 따른 나사못 유지력 예측 (Predicting the Withdrawal Load of Wood Screws in Domestic Wood by Screw Diameter, Depth of Penetration and Specific Gravity of Wood)

  • 차재경
    • Journal of the Korean Wood Science and Technology
    • /
    • 제39권3호
    • /
    • pp.252-257
    • /
    • 2011
  • 국내에서 생산되는 목재에 대한 나사못 유지력을 기존의 식으로부터 수정된 예측 식으로 나타내기 위해 나사 못 뽑기 실험을 실시했다. 본 연구에 사용된 나사못은 No. 6, No. 8 및 No. 10이었다. 예측 식은 길이가 서로 다른 No. 8 나사못의 실험결과와 매우 일치하였다. 나사못 유지력의 예측 식은 나사못의 직경과 관입길이 및 목재비중의 함수로 나타냈다. 예측 식은 나사못 길이가 25와 30 mm에서 5% 이내로 작게 예측되었으나 18과 38 mm에서 큰 값을 보였다.

어버트먼트 나사에 아-크 이온도금된 TiN과 ZrN피막의 부식특성과 표면 형상 (II) (Corrosion Characteristics and Surface Morphologies of TiN and ZrN Film on the Abutment Screw by Arc-ion Coating(II))

  • 정용훈;곽동묵;정재헌;김원기;최한철
    • Corrosion Science and Technology
    • /
    • 제10권6호
    • /
    • pp.212-217
    • /
    • 2011
  • In this study, corrosion characteristics of TiN and ZrN film on the abutment screw by arc-ion plating were investigated using a potentiodynamic anodic polarization test in deaerated 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The surface morphologies of the coating layers before and after corrosion test were investigated by a field-emission scanning electron microscope (FE-SEM) and a energy dispersive x-ray spectroscopy (EDS). The surfaces of the TiN and ZrN coated abutment screws showed the smooth surfaces without mechanical defects like scratches which can be formed during the manufacturing process, compared with those of the non-coated abutment screw. The corrosion and passive current densities of TiN and ZrN coated abutment screws were lower than those of the non-coated abutment screw.

Abrasion of abutment screw coated with TiN

  • Jung, Seok-Won;Son, Mee-Kyoung;Chung, Chae-Heon;Kim, Hee-Jung
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권2호
    • /
    • pp.102-106
    • /
    • 2009
  • STATEMENT OF PROBLEM. Screw loosening has been a common complication and still reported frequently. PURPOSE. The purpose of this study was to evaluate abrasion of the implant fixture and TiN coated abutment screw after repeated delivery and removal with universal measuring microscope. MATERIAL AND METHODS. Implant systems used for this study were Osstem and 3i. Seven pairs of implant fixtures, abutments and abutment screws for each system were selected and all the fixtures were perpendicularly mounted in liquid unsaturated poly-esther with dental surveyor. After 20 times of repeated closing and opening test, the evaluation for the change of inner surface of implant and TiN-coated abutment screw, and weight loss were measured. Mann-Whitney test with SPSS statistical software for Window was applied to analyze the measurement of weight loss. RESULTS. TiN-coated abutment screws of Osstem and 3i showed lesser loss of weight than non-coated those of Osstem and 3i (P < .05, Mann-Whitney test). CONCLUSION. Conclusively, TiN coating of abutment screw showed better resistance to abrasion than titanium abutment screw. It was concluded that TiN coating of abutment screw would reduce the loss of preload with good abrasion resistance and low coefficient of friction, and help to maintain screw joint stability.

Numerical model for bolted T-stubs with two bolt rows

  • Daidie, Alain;Chakhari, Jamel;Zghal, Ali
    • Structural Engineering and Mechanics
    • /
    • 제26권3호
    • /
    • pp.343-361
    • /
    • 2007
  • This article presents a numerical tool for dimensioning two-threaded fasteners connecting prismatic parts subjected to fatigue tension loads that are coplanar with the screw axis. A simplified numerical model is developed from unidirectional finite elements, modeling the connected parts and screws with bent elements and the elastic contact layer between the parts with springs. An algorithm updating the contact stiffness matrix, calculating forces and displacements at each node of the structure and thus normal stresses in the screws in both static and fatigue is further developed using C language. An experimental study is also conducted in parallel with the numerical approach to validate the developed model assumptions, the numerical model and the 3D finite element results. Since stiffness values for the compressive zones in the parts are analytically difficult to determine, a statistical software method is used, from which a tuning factor is derived for identifying these stiffness values. The method is also applied to set out the influence of each parameter on the fatigue behaviour of each screw. Finally, the developed model will be used to establish a new, sophisticated, fast and accurate tool for dimensioning bolted mechanical structures.

평면 직렬 메커니즘의 기하학적 속도 및 힘 해석 (Geometrical Velocity and Force Analyses on Planar Serial Mechanisms)

  • 이찬;이재원;서태원
    • 제어로봇시스템학회논문지
    • /
    • 제21권7호
    • /
    • pp.648-653
    • /
    • 2015
  • The kinematics with the instantaneous motion and statics of a manipulator has generally been proven algebraically. The algebraic solutions give very simple and straightforward results but the solutions do not have any meaning in physics or geometry. Therefore it is not easy to extend the algebraic results to design or control a robotic manipulator efficiently. Recently, geometrical approach to define the instantaneous motion or static relation of a manipulator is popularly researched and the results have very strong advantages to have a physical insight in the solution. In this paper, the instantaneous motion and static relation of a planar manipulator are described by geometrical approach, specifically by an axis screw and a line screw. The mass center of a triangle with weight and a perpendicular distance between the two screws are useful geometric measures for geometric analysis. This study provides a geometric interpretation of the kinematics and statics of a planar manipulator, and the method can be applied to design or control procedure from the geometric information in the equations.