• 제목/요약/키워드: screw fixation

검색결과 434건 처리시간 0.022초

제 2형 거골 경부 골절의 수술적 치료 (Surgical Treatment of Type II Talar Neck Fractures)

  • 전택수;김상범;김성훈;김태균;김승환
    • 대한족부족관절학회지
    • /
    • 제11권1호
    • /
    • pp.91-96
    • /
    • 2007
  • Purpose: To evaluate the clinical results and determine appropriate methods of surgical treatment about type II talar neck fracture. Materials and Methods: Among nineteen patients who received surgical treatment for type II talar neck fracture from May 2000 to May 2005. Fourteen patients with a follow-up period of more than 1 year were divided into two groups. Six patients reduced by closed reduction (Group A) with screw fixation and eight patients reduced by open reduction with screw fixation. We analyzed preoperative, postoperative and follow-up simple radiographs and reviewed patient hospital records retrospectively. Clinical results were evaluated by Hawkins scoring system. We analyzed pain, limp, range of motion of ankle and subtalar joint. Results: Five patients (83.3%) in group A and seven patients (87.7%) in group B had excellent and good clinical results. There were no complications including avascular necrosis, delayed union, nonunion. Conclusion: Closed reduction with screw fixation of talar neck fracture shows correct reduction and satisfactory results. But because of short term period of follow-up, we need long term results.

  • PDF

운동선수에서 횡방향 나사 고정 후 발생한 슬개골의 골절 - 증례 보고 - (Patellar fracture after transverse screw fixation in sports athletes - A case report -)

  • 라호종;김성태;하정구;김진구
    • 대한정형외과스포츠의학회지
    • /
    • 제10권2호
    • /
    • pp.109-112
    • /
    • 2011
  • 전위성 슬개골 골절에 있어서 해부학적 정복 및 견고한 고정은 슬관절 기능과 강도, 그리고 조기 관절 운동 범위의 회복을 위해서 필요하다. 골절의 형태와 다양한 수술 기법에 따라서, 수술 후 많은 합병증들이 보고 되어져 왔다. 본 저자들은 운동 선수들에게서 발생한 종골절 1예와 이분성 슬개골의 골편 전위 골절 1예에서 유관 나사못 횡 고정술을 시행한 뒤 새로운 횡골절이 발생한 증례를 경험하여 보고하고자 한다.

  • PDF

관절경하 AO 무두 압박 나사를 이용한 견갑골 전방 관절와 분쇄 골절의 치료 - 증례 보고 - (Treatment of Anterior Glenoid Rim Fracture with Comminuted Fragment Using Arthroscopic Reduction and AO Headless Compression Screw Fixation - A Case Report -)

  • 김형식;고일현;김성국;천용민;김성재;강호정
    • Clinics in Shoulder and Elbow
    • /
    • 제14권1호
    • /
    • pp.94-98
    • /
    • 2011
  • 목적: 견갑골 전방 관절와 분쇄 골절에 대해 관절경하 정복 및 AO 무두 압박 나사를 이용하여 골편을 고정한 증례를 보고하고자 한다. 대상 및 방법: 31세 남자로 내원 2주 전 추락 후 발생한 좌측 견관절의 전방 관절와 분쇄 골절에 대하여 관절경하에서 골절을 정복한 후, 표준 전상방 삽입구를 통해 1.1 mm K 강선을 가이드핀으로 삽입하고 AO 무두 압박 나사로 골편을 고정하였다. 결과: 수술 후 12개월째 견관절의 운동 범위는 정상 범위로 회복 되었으며, 골절은 유합을 얻었고 일상 생활에 불편감은 없었다. 결론: AO 무두 압박 나사는 나사의 길이가 다양하여 작은 관절와 골편에 사용하기 적합하고, 가이드 핀의 길이가 상대적으로 짧으나 1.1 mm K 강선으로 대체가 가능하며, 나사 돌리개 (screw driver)나 천공기 (drill bit) 등의 동반 기구의 길이가 길어 비교적 깊은 위치의 견갑과 골절의 고정에 사용하기 편리하여 관절경적 고정술 시 유용하게 이용할 수 있을 것으로 생각된다.

후방까지 연장된 안와하벽골절에서 안구함몰 예방을 위한 Medpor® 내고정술 (Internal Fixation of Medpor® Implant for Prevention of Enophthalmos in Posteriorly Extended Orbital Floor Fracture)

  • 석정훈;지소영;김태범;양완석
    • 대한두개안면성형외과학회지
    • /
    • 제9권2호
    • /
    • pp.55-61
    • /
    • 2008
  • Purpose: The purpose of this study is to evaluate the effectiveness of internal fixation method of $Medpor^{(R)}$ implant with $BioSorb^{TM}FX$ screw which is used for prevention of enophthalmos in posteriorly extended large orbital floor fracture. Methods: From Jun. 1997 to Dec. 2007, 21 patients who were diagnosed with posteriorly extended large orbital floor fractures were classified into two groups. One group(n=11) had undergone reduction surgery with regular $Medpor^{(R)}$ sheets without any fixation method, while the other group(n=10) had their $Medpor^{(R)}$ sheets fixed with the $BioSorb^{TM}FX$ screws. The two groups were evaluated by comparison of their enophthalmos degree and effectiveness. Results: In the non-fixation group, six patients had enophthalmos preoperatively and three of them showed persistent enophthalmos postoperatively. In postoperative CT examination, displacement of $Medpor^{(R)}$ implant with soft tissue impaction into maxillary sinus was observed in the patients. In the screw fixation group, three patients had enophthalmos preoperatively, but none of them suffer from complication such as residual enophthalmos, soft tissue impaction, muscle entrapment or optic nerve compression postoperatively. Conclusion: Internal fixation method of $Medpor^{(R)}$ implant with $BioSorb^{TM}FX$ screw on the medial surface of orbital floor provides firm stabilization of implants and surrounding soft tissues and can be an effective option especially when postoperative implant displacement or malposition was expected.

Removal of broken syndesmotic screw with minimal bone defects in Korea: a case report

  • Min Gyu Kyung;Chulhee Park
    • Journal of Trauma and Injury
    • /
    • 제36권3호
    • /
    • pp.265-268
    • /
    • 2023
  • Ankle fractures with syndesmotic injuries often require fixation, where metal screw fixation is a popular method. However, as the patient begins weight-bearing, most syndesmotic screws tend to loosen or break, and removal of such screws has been challenging for the surgeons, as the available techniques require predrilling or trephination and are associated with risks of bone damage. This study presents a case with technical tip for the removal of broken tricortical-fixed non-cannulated syndesmotic screws. It implements the generation of a small cortical window in the medial distal tibia and the use of pliers to engage the screw tip and remove through the medial side. The technique presented in the current study overcomes these limitations and facilitates minimal bone damage and reduced exposure to radiation.

하악골 후방이동시 악골고정방법에 따른 악간고정기간 중 치아 및 악골의 위치변화에 대한 연구 (A STUDY ON POSITIONAL CHANGES OF THE TEETH AND MANDIBLE ACCORDING TO FIXATION TYPE DURING INTERMAXILLARY FIXATION PERIOD AFTER MANDIBULAR SETBACK)

  • 박선배;김경욱
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제29권5호
    • /
    • pp.265-271
    • /
    • 2003
  • Skeletal relapse is known as a complication following orthognathic surgery of mandibular prognathism and occurring during intermaxillary fixation period. Therefore relapse of teeth and skeleton during intermaxillary fixation period is considered as a important problem of orthognathic surgery. In this study, cephalolateral radiographs taken at pre-operation, immediate post-operation and after release of intermaxillary fixation were measured for evaluation of dental and skeletal relapse in 30 cases. The cases were classified as screw fixation group and plate fixation group, then we compared magnitude of dental and skeletal changes of each group. The results were as follows 1. The $\underline{1}$ SN angle increased at immediate post-operation with a mean value of $0.12^{\circ}$ and at intermaxillary fixation period with a mean value of $0.43^{\circ}$ (p>0.05). 2. The $\overline{1}$ MP angle decreased with a mean value of $0.14^{\circ} at immediate post-operation and with a mean value of $1.28^{\circ} during intermaxillary fixation period but there were not significant difference(p>0.05). 3. There were not significant difference in magnitude of dental position changes between screw fixation group and plate fixation group(p>0.05). 4. Gonial angle increased with a mean value of $0.62^{\circ} during intermaxillary fixation period. Each group showed changes of gonial angle during intermaxillary fixation period but there were not significant difference(p>0.05).

Odontoid Synchondrosis Fracture Treated by C1-2 Polyaxial Screw-Rod Fixation

  • Muthukumar, Natarajan
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권4호
    • /
    • pp.212-214
    • /
    • 2014
  • The synchondrosis between the dens and the body of axis normally fuses between 5 and 7 years of age. Until this age, synchondrosis fractures can occur in children. Most synchondrosis fractures are conventionally treated by external immobilization alone. We report a 10-year-old child with odontoid synchondrosis fracture who was treated by C1 lateral mass and C2 pars screw rod fixation with a successful outcome and discuss the possible reasons for occurrence of odontoid synchondrosis fracture in this older child as well as the indications for surgery in this condition.

Comparative Analysis of Cervical Lateral Mass Screw Insertion among Three Techniques in the Korean Population by Quantitative Measurements with Reformatted 2D CT Scan Images : Clinical Research

  • Cho, Jae-Ik;Kim, Dae-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • 제44권3호
    • /
    • pp.124-130
    • /
    • 2008
  • Objective : Our purpose of this study is to compare insertion angles and screw lengths from Roy-Camille, Magerl, and our designed method for cervical lateral mass screw fixation in the Korean population by quantitative measurement of reformatted two dimensional (2D) computed tomography (CT) images. Methods : We selected thirty Korean patients who were evaluated with thin section CT scans and reconstruction program to obtain reformatted 2D-CT images of the transversal plane passing the cranio-caudal angle using three different techniques. We measured the minimum angle to avoid vertebral artery (VA) injury, the ideal angle and depth for bicortical screwing of cervical lateral mass. Morphometric measurements of the lateral masses from C3-C7 were also taken. Results : In all three techniques, the mean safety angles from the VA were less than 8 degrees and the necessary depth of the screw was about 14 mm for safety to the VA and for the bicortical purchase. In our designed technique, the mean $\beta$ angles of each level from C3 to C7 were 29.0. 29.8. 29.5. 26.3. and 23.9 degrees, respectively. Conclusion : Results of this study and data from the literature indicate that differences may exist between the Korean and Western people in the length and angle for ideal lateral mass screw fixation. In addition, our technique needs further cadaveric and clinical study for safety and efficacy for being performed as alternative method for cervical lateral mass fixation.

6.5 mm 해면골 전산나사를 이용한 Sanders Type II 또는 III형 종골 골절의 최소 침습적 치료 (Surgical Treatment of Calcaneal Fractures of Sanders Type II and III by A Minimally Invasive Technique with 6.5 mm Cancellous Screw)

  • 오용승;이경호;김정호;이명진
    • 대한족부족관절학회지
    • /
    • 제23권3호
    • /
    • pp.116-120
    • /
    • 2019
  • Purpose: This study evaluated the clinical and radiological results of 6.5 mm full threaded cancellous bone screw fixation of calcaneal fractures. Materials and Methods: Thirty seven patients diagnosed with Sanders type II or III calcaneal fractures, who underwent open reduction and internal fixation with a 6.5 mm full threaded cancellous bone screw between August 2014 and August 2017, were analyzed. Both the preoperative and postoperative Böhler angle and Gissane angle were measured radiographically. American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot scale on the final follow-up were also assessed. Results: The mean age of the patients was 52.7 years and the mean follow-up period was 29.5 months. In the Sanders classification, type II and III were 16 and 24 cases, respectively. The Böhler and Gissane angles improved from 21.2° and 122.6° preoperatively to 21.6° and 120.3°, respectively, in the postoperative radiographs. All cases achieved bony union, and the AOFAS ankle-hindfoot scale was 90.7 and 91.3 in Sanders type II and III, respectively, at the final follow-up. Conclusion: The treatment of calcaneal fractures using a 6.5 mm full threaded cancellous bone screw can reduce the complications with minimally invasive surgery and achieve firm fixation.

경도-중등도 무지외반증 환자의 생체 흡수성 마그네슘 나사못과 티타늄 나사못을 사용한 수술의 단기 결과 비교 (Comparing the Results of Using Bioabsorbable Magnesium Screw with Those Using a Titanium Screw for the Treatment of Mild to Moderate Hallux Valgus: Short-term Follow-Up)

  • 홍성엽;김갑래;한우솔
    • 대한족부족관절학회지
    • /
    • 제24권3호
    • /
    • pp.107-112
    • /
    • 2020
  • Purpose: Hallux valgus (HV) is a common foot deformity that causes pain in the first metatarsophalangeal joint. Distal metatarsal osteotomies are commonly performed as a treatment. This retrospective study compared the clinical and radiological results of bioabsorbable magnesium (Mg) versus titanium (Ti) screw fixation for modified distal chevron osteotomy in HV. Materials and Methods: Forty-nine patients, who underwent modified distal chevron osteotomy for HV in 2018 and 2019, were reviewed retrospectively. Bioabsorbable Mg screw fixation was applied in 20 patients (22 feet), and a traditional Ti compression screw was applied in 29 patients (40 feet). The patients were followed up for at least six months. The clinical results were evaluated using the American Orthopaedic Foot and Ankle Society hallux metatarsophalangeal-interphalangeal (AOFAS-MTP-IP) scale and a visual analogue scale (VAS). The hallux valgus angle (HVA), intermetatarsal angle (IMA), and distal metatarsal articular angle (DMAA) were measured before, after surgery, and at the six months follow-up. Results: The AOFAS-MTP-IP scale and VAS points were improved in both groups, with no significant difference between them. At the six-month follow-up, HVA, IMA, and DMAA were similar. Bone union was confirmed in both groups, and there were no significant major complications in both groups. Four people in the Ti screw group underwent implant removal surgery. Conclusion: Bioabsorbable Mg screws showed comparable clinical, radiologic results to Ti standard screws six months after distal modified chevron osteotomy. These screws are an alternative fixation material that can be used safely and avoid the need for implant removal operations.