• 제목/요약/키워드: screw diameter

검색결과 190건 처리시간 0.03초

임플란트 고정체의 나사산 형태와 하중조건에 따른 응력분석 (Finite Element Stress Analysis of the Implant Fixture According to the Thread Configuration and the Loading Condition)

  • 안옥주;정제옥;김창현;강동완
    • 구강회복응용과학지
    • /
    • 제21권2호
    • /
    • pp.153-167
    • /
    • 2005
  • The purpose of this study was to compare the v-shape thread with the square shape thread of fixture in the view of stress distribution pattern using finite element stress analysis. The finite element model was designed with the parallel placement of two standard fixtures(4.0 mm diameter ${\times}$ 11.5 mm length) on the region of mandibular 1st and 2nd molars. Three dimensional finite element model was created with the components of the implant and surrounding bone. This study simulated loads of 200 N at the central fossa in a axial direction (load A), 200 N at the buccal offset load that is 2 mm apart from central fossa in a axial direction (load B), 200 N at the buccal offset load that was 4 mm apart from central fossa in a axial direction (load C). These forces of load A',B',C' were applied to a $15^{\circ}$ inward oblique direction at that same site with 200 N. Von Mises stress values were recorded and compared in the supporting bone, fixture, and abutment screw. The following results have been made based on this study : 1. The highest stress concentration occurred at the cervical region of the implant fixture. 2. Von Mises stress value of off-site region was higher than that of central fossa region. 3. Square shape thread type showed more even stress distribution in the vertical and oblique force than V-shape thread type. 4. Stress distribution was the most effective in the case of buccal offset load (2, 4 mm distance from central fossa) in the square shape thread type. 5. V-shape thread type revealed higher von Mises stress value than square shape thread type in all environmental condition. The results from numerical analyses concluded that square shape thread type had the lower destructive stress and more stress distribution between the fixture and bone interface than V-shape thread type. Therefore, square shape thread type was regarded as optimal thread configuration in biomechanical concepts.

고리 금속판을 이용한 망치 손가락의 수술적 치료법 (Surgical treatment of Mallet finger deformity with Hook plate)

  • 최석민;정성균;신호성;박은수;김용배
    • Archives of Plastic Surgery
    • /
    • 제36권3호
    • /
    • pp.318-321
    • /
    • 2009
  • Purpose: The bony mallet finger injury is generally managed by conservative treatments, but operative treatments are needed especially when the fractures involve above 30% of articular surface or distal phalanx is accompanied by subluxation in the volar side. This is the reason they often result in chronic instability, articular subluxation and unsatisfactory cosmetic. In this report, We describe new method using the hook plate as an operative treatment of Mallet finger deformity. Methods: Among 13 patients with Mallet finger deformity who came from February 2006 to February 2008, six patient were included in surgical indication. Under local anesthesia, H or Y type incision was made at the DIP joint area. After the DIP joint extension, the hook plate was put on the fracture line, and one self tapping screw was used for fixation. 2 hole plate which was one of the holes in 1.5 mm diameter was cut in almost half and bended through approximately $100^{\circ}$. Results: In all six cases which applied the hook plate, complications such as loss of reduction or nail deformity were not seen. In only one patient, hook pate was removed due to inflammatory reaction after surgery. At 2 weeks after operation, active motion of DIP joint was performed. The result was satisfactory not only cosmetically but also functionally. At 6 weeks after operation, the range of motion of DIP joint was average $64^{\circ}$. Conclusion: The purpose of the operative treatment for mallet finger deformity using the hook plate is to provide anatomical reduction with rigid fixation and to prevent contracture at the DIP joint. While other operations take 6 weeks, the operation using the hook plate begins an active motion at 2 weeks after operation. Complication rate was low and the method is rather simple. Thus, the operation using the hook plate is recommended as a good alternative method of the mallet finger deformity treatment.

IV형의 골질로 재생된 골내에 식립된 원통형 임플란트의 유한요소법적 연구 (FINITE ELEMENT ANALYSIS OF CYLINDER TYPE IMPLANT PLACED INTO REGENERATED BONE WITH TYPE IV BONE QUALITY)

  • 김병옥;홍국선;김수관
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권4호
    • /
    • pp.331-338
    • /
    • 2004
  • Stress transfer to the surrounding tissues is one of the factors involved in the design of dental implants. Unfortunately, insufficient data are available for stress transfer within the regenerated bone surrounding dental implants. The purpose of this study was to investigate the concentration of stresses within the regenerated bone surrounding the implant using three-dimensional finite element stress analysis method. Stress magnitude and contours within the regenerated bone were calculated. The $3.75{\times}10-mm$ implant (3i, USA) was used for this study and was assumed to be 100% osseointegrated, and was placed in mandibular bone and restored with a cast gold crown. Using ANSYS software revision 6.0, a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The present study used a fine grid model incorporating elements between 165,148 and 253,604 and nodal points between 31,616 and 48,877. This study was simulated loads of 200N at the central fossa (A), at the outside point of the central fossa with resin filling into screw hole (B), and at the buccal cusp (C), in a vertical and $30^{\circ}$ lateral loading, respectively. The results were as follows; 1. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were increased from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, concentrated on the top of the cylindrical collar loading point B and C in vertical loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were increase from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in vertical loading. 2. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were decreased from loading point A to C in lateral loading. Stresses according to the depth of regenerated bone were concentrated on the top of the cylindrical collar in loading point A and B, distributed along the implant evenly in loading point C in lateral loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were decreased from loading point A to C in lateral loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in lateral loading. In summary, these data indicate that both bone quality surrounding the regenerated bone adjacent to implant fixture and load direction applied on the prosthesis could influence concentration of stress within the regenerated bone surrounding the cylindrical type implant fixture.

사과박의 펙틴 추출을 위한 압출 공정 모형화 (Modeling of Extrusion for Pectin Extraction from Apple Pomace)

  • 조용진;김종태;김철진;황재관
    • 한국식품과학회지
    • /
    • 제31권4호
    • /
    • pp.1011-1016
    • /
    • 1999
  • 식물의 세포벽 모형에 근거하여 고온고압의 조건하에서 기계적인 전단웅력을 식물 세포벽에 가할 경우 수용성 다당류를 효과적으로 분리할 수 있다는 가설에 근거하여 사과박으로부터 펙틴을 추출하기 위해 압출처리법을 도입하였다. L/D비가 20: 1인 동방향완전맞물림형 이축압출기를 이용하여 압출기의 축회전수, 원료의 공급률 및 원료의 수분함량을 공정변수로 하고 압출기의 비기계에너지를 시스템의 매개변수로 하여 압출처리에 의한 수용성 다당류의 수율, 평균 분자량 및 galacturonic acid 함량을 분석한 후, 각각의 모형을 개발하였다. 펙틴의 수율과 품질을 동시에 비교해 볼때, 비기계에너지를 증가시키면 펙틴의 수율이 향상되는 것으로 나타났으나, 수율을 향상시키는 압출조건은 품질의 저하를 초래하는 것으로 나타났다. 비기계에너지가 191 kWh/ton인 고강도의 추출조건에서 수율은 20.1%로 나타나 기존의 산처리법에 의한 14.4% 수율보다 월등히 향상된 수율을 얻을 수 있었다. 한편, 비기계에너지가 96 kWh/ton인 저강도의 추출조건에서는 분자량이 240,000인 펙틴을 얻을 수 있어 산처리시 분자량 181,000의 펙틴보다 훨씬 양질의 펙틴을 얻을 수 있었다. 따라서, 목표로 하는 품질의 펙틴을 생산할 수 있으면서 최고의 수율을 얻을 수 있는 압출조건을 설정해야 하며, 이를 위해서 본 연구에서 제시한 펙틴의 수율 및 품질 모형을 이용할 수 있다.

  • PDF

Effects of implant tilting and the loading direction on the displacement and micromotion of immediately loaded implants: an in vitro experiment and finite element analysis

  • Sugiura, Tsutomu;Yamamoto, Kazuhiko;Horita, Satoshi;Murakami, Kazuhiro;Tsutsumi, Sadami;Kirita, Tadaaki
    • Journal of Periodontal and Implant Science
    • /
    • 제47권4호
    • /
    • pp.251-262
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the effects of implant tilting and the loading direction on the displacement and micromotion (relative displacement between the implant and bone) of immediately loaded implants by in vitro experiments and finite element analysis (FEA). Methods: Six artificial bone blocks were prepared. Six screw-type implants with a length of 10 mm and diameter of 4.3 mm were placed, with 3 positioned axially and 3 tilted. The tilted implants were $30^{\circ}$ distally inclined to the axial implants. Vertical and mesiodistal oblique ($45^{\circ}$ angle) loads of 200 N were applied to the top of the abutment, and the abutment displacement was recorded. Nonlinear finite element models simulating the in vitro experiment were constructed, and the abutment displacement and micromotion were calculated. The data on the abutment displacement from in vitro experiments and FEA were compared, and the validity of the finite element model was evaluated. Results: The abutment displacement was greater under oblique loading than under axial loading and greater for the tilted implants than for the axial implants. The in vitro and FEA results showed satisfactory consistency. The maximum micromotion was 2.8- to 4.1-fold higher under oblique loading than under vertical loading. The maximum micromotion values in the axial and tilted implants were very close under vertical loading. However, in the tilted implant model, the maximum micromotion was 38.7% less than in the axial implant model under oblique loading. The relationship between abutment displacement and micromotion varied according to the loading direction (vertical or oblique) as well as the implant insertion angle (axial or tilted). Conclusions: Tilted implants may have a lower maximum extent of micromotion than axial implants under mesiodistal oblique loading. The maximum micromotion values were strongly influenced by the loading direction. The maximum micromotion values did not reflect the abutment displacement values.

SLA로 표면처리한 microthreaded crest module 임프란트의 임상적, 조직학적, 조직계측학적 분석 (Clinical, histologic, and histometric evaluation of implants with microthreaded crest module and SLA surface)

  • 문상권;방은경;김창성;조규성;채중규;김종관;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제34권1호
    • /
    • pp.127-138
    • /
    • 2004
  • Background: Crestal bone loss known as saucerization is a frequently observed phenomenon. Recent studies have shown that implants with micothreaded crest module reduced the force concentration in the crestal region thus resulting in no or reduced crestal bone loss. This study presents a clinical, histologic, and histometric evaluation of implants with microthreaded crest module and SLA surface. Methods: The implants were placed in the mandible of 5 beagle dogs weighing 10-15kg. Four premolars were bilaterally extracted 8 weeks prior to implant placement. Mucoperiosteal flap was elevated and drilling with increasing diameter was performed under saline irrigation. After countersinking 2 implants were placed in each side resulting in 4 implants per dog. Healing period of 8 weeks was allowed before sacrificing the animals. Histologic preparation was performed for histologic and histometric analysis. Bone to implant contact as well as percentage of bone area inside threads were measured. T-test was used for statistical analysis with pvalue p<0.05. Results: 1. Healing was uneventful without any cover screw exposure. New bone formation around the implants was observed without any inflammatory infiltration. 2. Bone to implant contact in the microthread and thread were 43.90 ${\pm}$ 20.30 %, and 53.19 ${\pm}$ 20.97 % respectively. The overall bone to implant contact was 48.54 ${\pm}$ 20.95 %. 3. Percentage of bone area inside threads were 54.43 ${\pm}$ 10.39 %, and 38.44 ${\pm}$ 16.44 % for the microthread and thread respectively. There was statistically significant difference(p<0.05). The overall percentage of bone area inside threads was 46.67 ${\pm}$ 15.68 %.

전기자극이 성견 골결손부에 매식된 임플란트 주위조직의 치유에 미치는 영향 (Effects of electrical stimulation on healing of endo-osseous titanium implants in circumferential defect)

  • 심재창;김영준;정현주;김옥수
    • Journal of Periodontal and Implant Science
    • /
    • 제34권1호
    • /
    • pp.177-193
    • /
    • 2004
  • Several experimental studies showed that the application of small amounts of electric current to bone stimulated osteogenesis at the site of the cathode and suggested that electrical currents promote osseointegration around dental implants. The purpose of this study was to determine the effect of direct microcurrent to endosseous titanium implants placed in bone defects. The right and left 2nd, 3rd and 4th mandibular premolars in ten mongrel dogs (15Kg of weight) were extracted. One monthe later, Ti-machined screw type implants(3.8 mm diameter x 8.5 mm length, $AVANA^{(R)}$, Ostem) were placed in surgically created circumferential defect area(width 5mm, depth 4mm). The implants were divided into three groups according to the treatment modalities: Control group- implants without electrical stimulation; Experimental group I- implants with allogenic demineralized freeze dried bone grafting; and Experimental group II-implants allogenic demineralized freeze dried bone grafting and electric stimulation. The animals were sacrificed in the 4th and 8th week after implant placement and un-decalcified specimens were prepared for histological and histometrical evaluation of bone-implant contact ratio (BIC) and bone formation area ratio (BFA) in defect area. Some specimens at 8 weeks after implantation were used for removal torque testing. Histologically, there was connective tissue infiltration in the coronal part of defect area in control and the experimental group I, whereas direct bone contact was found in the experimental group II without connective tissue invasion. Average BIC ratios at 4 weeks of healing were 60.1% in the experimental group II, 47.4% in the experimental group I and 42.7% in the control. Average BIC ratios at 8 weeks after implantation were 67.6% in the experimental group II, 55.9% in the experimental group I and 54.6% in the control. The average BFA ratio was 84.0% in the experimental group II, 71.8% in the experimental group I and 58.8% in the control at 4 weeks, and the BFA ratios were 89.6% in the experimental group II, 81.4% in the experimental group I and 70.5% in the control at 8 weeks after implantation. The experimental group II showed also significantly greater BIC and BFA ratios compared to the control and the experimental group I (p<0.05). The removal torque values at 8 weeks after implantation were 56 Ncm in the experimental group II, 49 Ncm in the experimental group I and 43 Ncm in the control. There was a statistically significant difference among 3 groups (p<0.05). These results suggest that electrical stimulation improve and accelerate bone healing around endosseous titanium implants in bone defect.

Evaluation of tissue ingrowth and reaction of a porous polyethylene block as an onlay bone graft in rabbit posterior mandible

  • Sosakul, Teerapan;Tuchpramuk, Pongsatorn;Suvannapruk, Waraporn;Srion, Autcharaporn;Rungroungdouyboon, Bunyong;Suwanprateeb, Jintamai
    • Journal of Periodontal and Implant Science
    • /
    • 제50권2호
    • /
    • pp.106-120
    • /
    • 2020
  • Purpose: A new form of porous polyethylene, characterized by higher porosity and pore interconnectivity, was developed for use as a tissue-integrated implant. This study evaluated the effectiveness of porous polyethylene blocks used as an onlay bone graft in rabbit mandible in terms of tissue reaction, bone ingrowth, fibrovascularization, and graft-bone interfacial integrity. Methods: Twelve New Zealand white rabbits were randomized into 3 treatment groups according to the study period (4, 12, or 24 weeks). Cylindrical specimens measuring 5 mm in diameter and 4.5 mm in thickness were placed directly on the body of the mandible without bone bed decortication, fixed in place with a titanium screw, and covered with a collagen membrane. Histologic and histomorphometric analyses were done using hematoxylin and eosin-stained bone slices. Interfacial shear strength was tested to quantify graft-bone interfacial integrity. Results: The porous polyethylene graft was observed to integrate with the mandibular bone and exhibited tissue-bridge connections. At all postoperative time points, it was noted that the host tissues had grown deep into the pores of the porous polyethylene in the direction from the interface to the center of the graft. Both fibrovascular tissue and bone were found within the pores, but most bone ingrowth was observed at the graft-mandibular bone interface. Bone ingrowth depth and interfacial shear strength were in the range of 2.76-3.89 mm and 1.11-1.43 MPa, respectively. No significant differences among post-implantation time points were found for tissue ingrowth percentage and interfacial shear strength (P>0.05). Conclusions: Within the limits of the study, the present study revealed that the new porous polyethylene did not provoke any adverse systemic reactions. The material promoted fibrovascularization and displayed osteoconductive and osteogenic properties within and outside the contact interface. Stable interfacial integration between the graft and bone also took place.

파일럿 규모 기포 유동층 반응기를 이용한 하수 슬러지 연소 특성 분석 (Investigation on Combustion Characteristics of Sewage Sludge using Pilot-scale Bubbling Fluidized Bed Reactor)

  • 김동희;허강열;안형준;이영재
    • 청정기술
    • /
    • 제23권3호
    • /
    • pp.331-342
    • /
    • 2017
  • 하수 슬러지 고형연료 및 우드 펠렛의 연소 특성을 평가 하기 위하여 열중량 분석(TGA), 회 융점(AFT) 분석, 그리고 회분 성분 분석을 수행하였다. TGA 분석 결과, 하수 슬러지 고형연료의 연소성이 우드 펠렛에 비해 상대적으로 좋지 않았다. 또한 AFT 분석을 통해 하수 슬러지 고형연료의 슬래깅 가능성이 매우 높은 것을 확인하였다. 또한 연소성 평가를 위해 pilot-scale 기포 유동층 반응기를 적용하였으며, 장치는 예열기, 유동층 반응기, 연료 공급장치, 사이클론, 회분 포집 장치, 그리고 가스분석기로 구성되었다. 반응기는 직경 400 mm, 높이 4300 mm이며, 하수 슬러지는 $54.5{\sim}96.5kW_{th}$의 열량으로 실험을 수행하였고 우드 펠렛은 $96.1kW_{th}$ 실험을 수행하였다. 실험 결과, 하수 슬러지 고형연료 연소의 경우 평균적으로 우드 펠렛의 연소 보다 배기가스 중 $NO_x$는 10.1배, CO는 3.5배 높았다. 또한 사이클론에서 포집한 회분을 분석한 결과, 모든 실험 조건에서 연소 효율은 99% 이상이었고, 회분의 성분 분석을 통해 슬래깅/파울링 가능성이 높은 것을 확인하였다.

가토 경골에 식립된 Ca-P 박막코팅 임프란트의 뒤틀림 제거력 및 조직형태학적 평가 (THE EVALUATION OF THE REMOVAL TORQUE AND THE HISTOMORPHOMETRY OF THE CA-P COATING SURFACE IN RABBIT TIBIA)

  • 곽명배;이청희
    • 대한치과보철학회지
    • /
    • 제42권5호
    • /
    • pp.556-571
    • /
    • 2004
  • Statement of problem: Surface texture of the implant is one of the important factors of the implant success, especially in the immediate implant loading. Many methods of the surface treatment of implant have developed and introduced. Purpose : This study was to evaluate the effects of the Ca-P coating implant crystallized the hydroxyapatite on the surface by the removal torque test and the histomorphometric analysis in vivo. Material and methods: 135 screw type implants, 4.0mm in length and 3.75mm in diameter were used in this study. Implants were divided into 3 groups and treated in the different mothods. Group I was not treated, Group II was treated in the SLA method, and Group III was treated in the Ca-P coating with the anodizing method and the hydroxyapatite was crystallized on the surface with the hydrothermal treatment. Firstly, the surface roughness of each group was measured, 45 rabbits were used in this experiment. Two implants were inserted on right tibial metaphysis and one implant was inserted on left side with the alternating order. After the healing periods of 3, 5, and 12 weeks, the rabbits were sacrificed to evaluate the osseointergration by the removal torque test and the histomorphometric analysis. Results : 1. In the analysis for the surface roughness, Group II showed the highest roughness. And Group III showed higher secondly. There was a significant difference one another statistically 2. In the removal torque test, Group III and II were significantly higher than Group I. There was no statistical difference between Group III and Group II. 3. For all Groups, the removal torque values at 12th week were significantly higher than at 3rd and 5th week. 4. In histomorphometric analysis, the bone implant contact rates of Group III and II were higher than that of Group I at 3rd and 5th week. There was a significant difference at 5th week. 5. In histomorphometric analysis, the bone implant contact rate of Group III and II increased from 3rd week to 5th week, but decreased at 12th week. In Group I, the contact rate at 12th week was significantly higher than at 3rd week and 5th week.