• Title/Summary/Keyword: screw diameter

Search Result 190, Processing Time 0.031 seconds

A Study on the Temperature Uniformity for the Anti-Corrosion Coating Process of Large-Sized Water Pipes (대형배관 내부식 코팅공정의 온도 균일성 향상을 위한 와류날개 형상 연구)

  • Park, Jaehyun;Park, Heesung;Kim, Sootae;Kang, Gyuongmoo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.6
    • /
    • pp.35-40
    • /
    • 2016
  • In this study, the thermal and fluid dynamic characteristics for the coating process of large-sized water pipes was studied by heating the inside of a pipe directly with a gas burner. Heat and flow analyses were performed on large pipes with various inlet shapes. Using large pipes for coating was shown to be the proper shape for heating large pipes uniformly. This type has a screw with a diameter of 200 mm installed at the inlet to provide a rotational motion to the heating air. The rotational motion resulted in a uniform temperature distribution that ranged from $289.1^{\circ}C$ to $352.1^{\circ}C$ The optimized geometric configuration of the inlet of the pipe successfully and uniformly enhanced the thermal characteristics of the devised temperature limit.

Preparation and Properties of Poly(ethylene terephthalate)(PET)/Polyamide-6(PA6) Alloy Fibers using Epoxy as a Reactive Compatibilizer: I. Effect of Epoxy on the Phase Separation of PET/PA6 Alloys (에폭시를 반응성 상용화제로 사용하여 제조한 폴리에틸렌테레프탈레이트와 폴리아미드-6 알로이 섬유의 구조와 성질: 1. 알로이의 상분리에 미치는 에폭시의 효과)

  • Zhou, Jing;Min, Byung-Gil;Lim, Mok-Keun;Lee, Kwang-Sang;Yu, Yeong-Chool;Han, Jae-Sung
    • Textile Coloration and Finishing
    • /
    • v.24 no.2
    • /
    • pp.145-151
    • /
    • 2012
  • Polymer alloys of poly(ethylene terephthalate)(PET) and nylon6(PA6) which were not miscible each other by themselves were successfully prepared through melt compounding using a twin-screw extruder by utilizing epoxy as reactive compatibilizer. At the epoxy(DGEBA) amount of 0.5~2wt%, the domain size(average diameter) of the discontinuous phase could be reduced up to 0.2${\mu}m$ from 1-5${\mu}m$ that of the simple blend without epoxy. The reaction was presumed to happen mostly at interphase from the result of maximum increase of melt viscosity at the middle range of PET/PA6 blend ratio. It is expected that alloy fibers of PET/epoxy/PA6 with enough mechanical strength for use can be prepared.

The Elasto-Plastic Buckling Analysis of Ball-Jointed Single Layer Latticed Domes considering the Characteristics of a Connector (적합부 특성을 고려한 볼 접합 단층 래터스 돔의 탄소성 좌굴해석)

  • Han, Sang-Eul;Kwon, Hyun-Jae;Kim, Jong-Bum
    • Journal of Korean Association for Spatial Structures
    • /
    • v.3 no.2 s.8
    • /
    • pp.91-99
    • /
    • 2003
  • The purpose of this study is to analyze the characteristics of the connector having an influence on the elasto-plastic buckling load of ball-jointed single layer latticed domes. As an analytic model, domes are composed of tubular member elements, balls and connectors. The joint system of members in single layer latticed domes has influence on the buckling load. Therefore, in this paper, the variation of the elasto-plastic buckling load by effects of the connectors characteristics is analyzed. The structural behavior of the connector is investigated by following points: (1) the length of rigid zone, (2) looseness of screw and (3) the diameter of connector. In addition, the elasto-plastic buckling analysis is carried out through the variation of the connectors section of yielding part, and then the buckling mode of the dome is examined. As a result, it is emphasized that the characteristics of the connector have significant effects on the buckling load of latticed domes.

  • PDF

Finite Element Analysis of Supporting Bone according to Custom Abutment Angles (맞춤형 지대주 각도에 따른 지지골의 유한요소 분석)

  • Nam, Min-Gyeong;Kim, Nam-Sic
    • Journal of Technologic Dentistry
    • /
    • v.37 no.3
    • /
    • pp.115-120
    • /
    • 2015
  • Purpose: The purpose of this study is a finite element analysis of supporting bone according to custom abutment angle. Methods: Implant fixture was selected with a diameter of 4 mm and the length of 13 mm. The fixture and abutment was designed by a combination of the abutment screw clamping force to produce a custom abutment model of $0^{\circ}$, $15^{\circ}$, $25^{\circ}$ and $35^{\circ}$. The loading condition of 176 N was applied to the lingual surface of the crown, near to the incisor edge, and horizontal load. An oblique load of $90^{\circ}$ was applied long axis of the implant fixture analyze the stress of supporting bone. Results: The result of mechanical analysis was observed that the supporting bone stress analysis of the horizontal load, the von Mises stress values (MPa) are given in the order of TH00 (432.6) > TH25 (418.0) > TH15 (417.4) > TH35 (415.8), the oblique load, the von Mises stress values are given in the order of TO00 (459.3) > TO15 (399.6) > TO25 (374.8) > TO35 (343.4) Conclusion: The $35^{\circ}$ abutment over the current clinical tolerance limits will be available for clinical application.

AN ANALYSIS AND MANAGEMENT OF FRACTURED IMPLANTS (파절된 임프란트 고정체의 분석과 처치)

  • Han Chang-Hyun;Kim Sung-Hyun;Hee Seong-Joo;Ku Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.25-36
    • /
    • 2001
  • Among the numerous factors contributing to implant failure, the most common are infection, failure of proper healing and overload. These factors may occur combined. Implant fractures are one of the complications resulting from overload. Implant fracture is not a common feature, but once it occurs it causes very unpleasant circumstances for the patient as well as for the practitioner. Only few studies have been reported regarding this subject. Thus, little is known about its solutions. It is important that analyzing reasons for implant fracture and finding appropriate solutions. Factors leading to implant fracture are design, material defects, nonpassive fit of prosthetic framework and biomechanical overload. Previous studies have reported that implant fractures ares associated with marginal bone loss and occur mostly in the posterior regions and that most patients showing parafunctional habits also have implant fracture. Abutment and gold screw loosening or fracture were also observed in some of the cases previous to implant fracture. Similar observations were seen in our hospital as well. The following cases will present implant fracture cases which have been successfully treated regarding function and biomechanics. This was achieved by means of using increased number of futures, increasing fixture diameter and establishing proper occlusion.

  • PDF

A Study on Quality Management Improvement of Used Pipe Support(V2) (재사용 파이프서포트(V2)의 품질관리 향상에 관한 연구)

  • Park, Jongkeun;Choi, Myeongki
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.36-41
    • /
    • 2019
  • As the prefabricated shoring system structure, which is a temporary structure, is often collapsed due to various reasons during concrete pouring, and directly affects not only the safety of the workers but also the quality of the final building, it is necessary to ensure the safety. It is considered that the pipe supports which are widely used as the prefabricated shoring materials in the construction site do not satisfy the performance criteria in many cases. Therefore, this study investigated the detailed conditions for satisfying the performance criteria and suggested the factors for improving the quality control level in order to prevent collapse accidents due to pipe supports reused at the construction site, As the results of test in order to understand the effect of the pipe supports (V2), which are being reused in the field, on the performance by factor, the performance was evaluated to be high in case of the small female screw clearance and the supporting pin with 12mm in diameter or larger.

Estimation of Lower Jaw Density using CT data

  • Jargalsaikhan, Ariunbold;Sengee, Nyamlkhagva;Telue, Berekjan;Ochirkhvv, Sambuu
    • Journal of Multimedia Information System
    • /
    • v.6 no.2
    • /
    • pp.67-74
    • /
    • 2019
  • Bone density is one of the factors in the early failure of dental implants and doctors should make a preoperative assessment of jaw bone density using patient's CT data before dental implant surgery in order to find out whether the patient has osteoporosis and osteopenia. The main goal of this study was to propose a method that based on image processing techniques in order to provide accurate information about where to drill and place an abutment screw of implants in the jaw bone for doctors and reduce human activity for the estimation of the local cancellous bone density of mandible using CT data. The experiment was performed on a computed tomography data of the jaw bone of two different individuals. We assumed that the result of the estimation of jaw bone density depends on the angle of drilling and average HU (Hounsfield Unit) values were used to evaluate the quality of local cancellous bone density of mandible. As a result of this study, we have been developed a toolbox that can be used to estimate jaw bone density automatically and found a positive correlation between the angle of the drill and time complexity but a negative correlation between the diameter of the drill and time complexity.

Mandibular 4 incisors implant restoration (하악 4전치 상실 시 임플란트 수복)

  • Park, Jong hyun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.31 no.2
    • /
    • pp.56-63
    • /
    • 2022
  • The mandibular 4 anterior incisor restoration has small teeth and a small space, so the choice of abutment is always a concern. The mandibular 4 anterior incisor extraction is caused by periodontal disease, interdental embrasure greatly open is advantageous of oral hygiene management. Try to make it small diameter with custom abutment, it is limited to the space for the screw. Rather than setting the post site of one body implant to a horizontal cross-section, it is advantageous to set it to a longitudinal cross-section, for interdental embrasure formation. When using an internal bone level implant, rather than using a two-piece abutment, using a one-piece abutment can more effectively secure space for interdental embrasure.

Evaluation of minimally invasive surgical reduction of sacroiliac luxation in toy breed dogs: a cadaver study

  • Ahn, Seoung-Yob;Jeong, Soon-Wuk
    • Journal of Veterinary Science
    • /
    • v.23 no.2
    • /
    • pp.38.1-38.13
    • /
    • 2022
  • Background: Minimally invasive surgery (MIS) technique of sacroiliac luxation in toy breed dogs using cannulated screws has not been described. Objectives: The purpose of this study was to evaluate the effectiveness of pelvic canal recovery, the reproducibility of successful surgery outcomes, and the acceptable difficulty of the procedure in MIS of sacroiliac luxation in toy breed dogs. Methods: MIS using 2.3-mm cannulated screws was demonstrated in 12 toy breed dog cadavers with sacroiliac luxation artificially induced. Pre and postoperative radiographs were used to evaluate the pelvic canal diameter ratio (PCDR), hemipelvic canal width ratio (HCWR), and reduction rate. Dorsoventral angle (DVA) and craniocaudal angle (CCA) of the inserted screw were obtained postoperative computed tomographic scan. Results: The statistically significant difference between the mean pre and postoperative PCDR was found (1.10 ± 0.12 and 1.26 ± 0.11, respectively; p = 0.002), and the mean HCWR close to 1.0 meaning symmetric pelvis also was obtained (0.97 ± 0.07). The mean DVA and CCA were 2.26° ± 1.33° and 2.60° ± 1.86°, respectively. Conclusions: MIS of sacroiliac luxation using 2.3-mm cannulated screws is applicable to toy breed dogs with acceptable difficulty.

Optomechanical Design and Structural Analysis of Linear Astigmatism Free - Three Mirror System Telescope for CubeSat and Unmanned Aerial Vehicle

  • Han, Jimin;Lee, Sunwoo;Park, Woojin;Moon, Bongkon;Kim, Geon Hee;Lee, Dae-Hee;Kim, Dae Wook;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.38.3-38.3
    • /
    • 2021
  • We are developing an optomechanical design of infrared telescope for the CubeSat and Unmanned Aerial Vehicle (UAV) which adapts the Linear Astigmatism Free- Three Mirror System in the confocal off-axis condition. The small entrance pupil (diameter of 40 mm) and the fast telescope (f-number of 1.9) can survey large areas. The telescope structure consists of three mirror modules and a sensor module, which are assembled on the base frame. The mirror structure has duplex layers to minimize a surface deformation and physical size of a mirror mount. All the optomechanical parts and three freeform mirrors are made from the same material, i.e., aluminum 6061-T6. The Coefficient of Thermal Expansion matching single material structure makes the imaging performance to be independent of the thermal expansion. We investigated structural characteristics against external loads through Finite Element Analysis. We confirmed the mirror surface distortion by the gravity and screw tightening, and the overall contraction/expansion following the external temperature environment change (from -30℃ to +30℃).

  • PDF