• Title/Summary/Keyword: screening assessment

Search Result 609, Processing Time 0.029 seconds

A Method of Vulnerable Area Selection for Voltage Stability Using the Variation Rate of Reactive Power Margin (무효전력 여유변화를 이용한 전압안정성 취약지역 선정)

  • Cho, Yoon-Hyun;Seo, Sang-Soo;Lee, Byong-Jun;Kim, Tae-Kyun;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.251-254
    • /
    • 2003
  • A voltage stability assessment consists of the contingency screening, voltage stability analysis, and counter measures. A widely used index for the voltage stability assessment of power system is the reactive power margin. It shows some factors of voluntariness as following the status of power system and load levels for the target analyzing area. Therefore, it has a demerit that the absolute amounts of reactive power margin is not to be applied by the quantized margin criterion. This paper selects a vulnerable area by assigning the voltage instability for the particular contingency for the selection of vulnerable area in the respect of the investigation of reactive power margin or VQVI as an index of V-Q margin sensitivity in order to overcome the demerit. This will be able to grasp the V-Q margin sensitivity for the target analyzing area by presenting the ratio of power margin between the margin before and after contingency as following the calculation of reactive power margin. The presented method is applied to the voltage stability assessment for the Metropolitan area of 2003 KEPCO summer peak system.

  • PDF

Applications, Shortcomings, and New Advances of Job Safety Analysis (JSA): Findings from a Systematic Review

  • Fakhradin Ghasemi;Amin Doosti-Irani;Hamed Aghaei
    • Safety and Health at Work
    • /
    • v.14 no.2
    • /
    • pp.153-162
    • /
    • 2023
  • Background: Job safety analysis (JSA) is a popular technique for hazard identification and risk assessment in workplaces that has been applied across a wide range of industries. This systematic review was conducted to answer four main questions regarding JSA: (1) which sectors and areas have used JSA? (2) What has been the aim of employing JSA? (3) What are the shortcomings of JSA? (4) What are the new advances in the field of JSA? Methods: Three main international databases were searched: SCOPUS, Web of Science, and PubMed. After screening and eligibility assessment, 49 articles were included. Results: Construction industries have used JSA the most, followed by process industries and healthcare settings. Hazard identification is the main aim of JSA, but it has been used for other purposes as well. Being time-consuming, the lack of an initial list of hazards, the lack of a universal risk assessment method, ignoring hazards from the surrounding activities, ambiguities regarding the team implementing JSA, and ignorance of the hierarchy of controls were the main shortcomings of JSA based on previous studies. Conclusion: In recent years, there have been interesting advances in JSA making attempts to solve shortcomings of the technique. A seven-step JSA was recommended to cover most shortcomings reported by studies.

Adjusting for Confounders in Outcome Studies Using the Korea National Health Insurance Claim Database: A Review of Methods and Applications

  • Seung Jin Han;Kyoung Hoon Kim
    • Journal of Preventive Medicine and Public Health
    • /
    • v.57 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • Objectives: Adjusting for potential confounders is crucial for producing valuable evidence in outcome studies. Although numerous studies have been published using the Korea National Health Insurance Claim Database, no study has critically reviewed the methods used to adjust for confounders. This study aimed to review these studies and suggest methods and applications to adjust for confounders. Methods: We conducted a literature search of electronic databases, including PubMed and Embase, from January 1, 2021 to December 31, 2022. In total, 278 studies were retrieved. Eligibility criteria were published in English and outcome studies. A literature search and article screening were independently performed by 2 authors and finally, 173 of 278 studies were included. Results: Thirty-nine studies used matching at the study design stage, and 171 adjusted for confounders using regression analysis or propensity scores at the analysis stage. Of these, 125 conducted regression analyses based on the study questions. Propensity score matching was the most common method involving propensity scores. A total of 171 studies included age and/or sex as confounders. Comorbidities and healthcare utilization, including medications and procedures, were used as confounders in 146 and 82 studies, respectively. Conclusions: This is the first review to address the methods and applications used to adjust for confounders in recently published studies. Our results indicate that all studies adjusted for confounders with appropriate study designs and statistical methodologies; however, a thorough understanding and careful application of confounding variables are required to avoid erroneous results.

Improvement of the Result Related to Tumor Marker Test Through the OCS QC Program (OCS QC 프로그램을 통한 건진 센터 종양검사의 결과보고 개선)

  • Back, Song-Ran;Kim, Sung-Ho;Yoo, So-Yeon;Kim, Nyun-Ok;Moon, Hyoung-Ho;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.185-188
    • /
    • 2009
  • Purpose: Standard of retests were discrepant and inconsistent due to inaccuracy and lack of standardization within normal range limit of tumor marker test. To enhance the standardization of retests set standard value below normal range and the Order Communication System Quality Control (OCS QC) program was put in place. This program enables managing the results within lower limit of normal range which were used for tumor marker test in Health Center. Materials and Methods: At present the tumor marker study for AFP, CEA, CA19-9, CA125, and PSA included outpatients in Asan Medical Center from February to March, 2009. The standard value was obtained by using the percentage of CV of Inter Assay according to the normal range of each tumor test. The results were confirmed by using the OCS QC program via formatted assessment of screening test such as test items, standard value and medical department. The number of out-of-range results within plus and minus 30 percents regarding the five primary items of tumor marker test was assessed. The next step was to obtain the number of AFP, CEA, and CA125 according to the ratio of comparison between prior and post test result, 60%, 50%, and 40% within normal range, respectively. In addition, set standard value below normal range. Results: The first screening test with percentage of sample number was resulted between 30%-40% and the second one was AFP 26.1%, CEA 18.9%, CA19-9 17.3%, CA125 18.7%, and PSA 21.0% obtained screening percentage of average 20 percents. The limited value of retest was AFP less than 5.0 and more than 10.0, CEA less than 1.0 and more than 3.0, CA19-9 less than 10.0 and more than 30.0, and PSA less than 1.0 and more than 2.0 to set and the number of retest was obtained by applying to the limited value of retest to screening percentage of average 20 percents For two months, the number of retest was AFP 0, CEA 15, CA19-9 3, CA125 2, and PSA 5. Conclusions: Through using the OCS QC program in establishing the standard of retest systemically, there appeared to be reduced discrepancy among the examiners and to be expected improvement in relation to the error of results.

  • PDF

Comparison of Mammography in Combination with Breast Ultrasonography Versus Mammography Alone for Breast Cancer Screening in Asymptomatic Women

  • Boonlikit, Sarawan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.12
    • /
    • pp.7731-7736
    • /
    • 2013
  • Aim: To compare the agreement of screening breast mammography plus ultrasound and reviewed mammography alone in asymptomatic women. Materials and Methods: All breast imaging data were obtained for women who presented for routine medical checkup at National Cancer Institute (NCI), Thailand from January 2010 to June 2013. A radiologist performed masked interpretations of selected mammographic images retrieved from the computer imaging database. Previous mammography, ultrasound reports and clinical data were blinded before film re-interpretation. Kappa values were calculated to assess the agreement between BIRADS assessment category and BIRADS classification of density obtained from the mammography with ultrasound in imaging database and reviewed mammography alone. Results: Regarding BIRADS assessment category, concordance between the two interpretations were good. Observed agreement was 96.1%. There was moderate agreement in which the Kappa value was 0.58% (95%CI; 0.45, 0.87). The agreement of BI-RADS classification of density was substantial, with a Kappa value of 0.60 (95%CI; 0.54, 0.66). Different results were obtained when a subgroup of patients aged ${\geq}60$ years were analyzed. In women in this group, observed agreement was 97.6%. There was also substantial agreement in which the Kappa value was 0.74% (95%CI; 0.49, 0.98). Conclusions: The present study revealed that concordance between mammography plus ultrasound and reviewed mammography alone in asymptomatic women is good. However, there is just moderate agreement which can be enhanced if age-targeted breast imaging is performed. Substantial agreement can be achieved in women aged ${\geq}60$. Adjunctive breast ultrasound is less important in women in this group.

Hindi version of short form of douleur neuropathique 4 (S-DN4) questionnaire for assessment of neuropathic pain component: a cross-cultural validation study

  • Gudala, Kapil;Ghai, Babita;Bansal, Dipika
    • The Korean Journal of Pain
    • /
    • v.30 no.3
    • /
    • pp.197-206
    • /
    • 2017
  • Background: Pain with neuropathic characteristics is generally more severe and associated with a lower quality of life compared to nociceptive pain (NcP). Short form of the Douleur Neuropathique en 4 Questions (S-DN4) is one of the most used and reliable screening questionnaires and is reported to have good diagnostic properties. This study was aimed to cross-culturally validate the Hindi version of the S-DN4 in patients with various chronic pain conditions. Methods: The S-DN4 is already translated into the Hindi language by Mapi Research Trust. This study assessed the psychometric properties of the Hindi version of the S-DN4 including internal consistency and test-retest reliability after 3 days' post-baseline assessment. Diagnostic performance was also assessed. Results: One hundred sixty patients with chronic pain, 80 each in the neuropathic pain (NeP) present and NeP absent groups, were recruited. Patients with NeP present reported significantly higher S-DN4 scores in comparison to patients in the NeP absent group (mean (SD), 4.7 (1.7) vs. 1.8 (1.6), P < 0.01). The S-DN4 was found to have an AUC of 0.88 with adequate internal consistency (Cronbach's ${\alpha}=0.80$) and a test-retest reliability (ICC = 0.92) with an optimal cut-off value of 3 (Youden's index = 0.66, sensitivity and specificity of 88.7% and 77.5%). The diagnostic concordance rate between clinician diagnosis and the S-DN4 questionnaire was 83.1% (kappa = 0.66). Conclusions: Overall, the Hindi version of the S-DN4 has good internal consistency and test-retest reliability along with good diagnostic accuracy.

A Study on the Health Status and the Needs of Health-related Services of Female Elderly in an Urban-rural Combined City (여성노인의 건강상태와 건강관련서비스 요구)

  • Kang Young Sil;Kim Eun Sim;Gu Mee Ock;Eun Young
    • Journal of Korean Public Health Nursing
    • /
    • v.17 no.1
    • /
    • pp.47-57
    • /
    • 2003
  • The purpose of this study was to investigate health status and health promoting behaviors of female elderly, and their needs for health-related services in an urban-rural combined city. The data were collected from the subjects registered in senior welfare center and senior citizens' clubs. A total of 119 women were participated in the survey. The results of the study are as follows; 1. The subjects perceived their health status relatively unhealthy. Their health promotion behavior score was 10.82 (range 0-17), and more than $60\%$ of them performed well in smoking and drinking control, regular meal. taking breakfast, and maintaining good relationship with others. 2. The most needed service was health screening followed by health risk assessment, disease diagnosis and treatment. 3. The most demanded education was on dementia prevention, followed by exercise, balanced diet, and maintenance of memorial and mental capability. 4. As the health interest and the health responsibility increased, the need for health service increased as well. Likewise, the health education needs increased as the health interest, health responsibility, and health promotion behavior increased. The results show that the health promotion programs for female elderly need to be focused, primarily, on health screening, health risk assessment, medical services for disease diagnosis and treatment, and health consulting and education. And health consulting and education programs should be designed to promote health interest and health responsibility of female elderly, change positively their attitude to aging, and include education on dementia prevention, exercise and nutrition management. Recommendations are discussed.

  • PDF

A Study on Methodology and Application of Life Cycle Assessment - Concerning Semiconductor (반도체를 대상으로 한 LCA(Life Cycle Assessment)의 방법론 및 적용에 관한 연구)

  • Chung, Chan Kyo;Koo, Hee Jun
    • Clean Technology
    • /
    • v.2 no.2
    • /
    • pp.201-213
    • /
    • 1996
  • Environmental regulation has traditionally focused on specific phenomena and adopted the so-called end-of-pipe approach. Recently, however, the new environmental paradigm is more concerned with minimization of waste generation, efficient material and energy use, pollution prevention, etc. The basis of above concept is that one must consider the environmental impacts of a product not only during its manufacturing stage, but during all life stages. In the present study, the current status of LCA and its importance to environmental impacts have been reviewed. In the usual approach to LCA, screening LCA method has been used to promote international competition and define environmental concerns during semiconductor manufacturing. In the present study, a review of semiconductor manufacturing process and its environmental implication has been conducted to quantify the material and energy requirements, minimize the waste generation, and evaluate production cost. Recommended activities are also specified for process modification to improve the process efficiency.

  • PDF

Comparative Study of Korean Workers' Exposure to Dichloromethane by Process Category between Work Environment Monitoring Program and ECETOC TRA (국내 디클로로메탄 제조·사용 사업장 근로자의 공정별 노출수준에 대한 작업환경측정값과 ECETOC TRA 모델값 비교연구)

  • Jeong, Sujin;Bae, Gyewan;Lee, Naroo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.4
    • /
    • pp.317-330
    • /
    • 2021
  • Objectives: By law, companies in Korea must periodically measure workers' exposure to harmful chemicals (the system is called the Work Environment Monitoring Program (WMP)[a]) and report the results to the government. The government also measures exposure to monitor the WMP's reliability (called Reliability Assessment (RA) for WMP[b]). The issue is that measured data from these two sources are so different that the objectivity of WMP needs to be confirmed by comparing the results using the European Centre for Ecotoxicology and Toxicology of Chemicals' Targeted Risk Assessment (ECETOC TRA). Methods: Step 1: Data collection from WMP reports submitted by companies (n=586) and RA for WMP written by the government (n=33). Step 2: Data Standardization by key information included. Step 3: Data conversion to input-variables required to run the ECETOC TRA model, and run the model with specific data (n=514) which meet the predetermined exposure scenario. Step 4: Statistical data analysis by process category (PROC) and ventilation type from each source ([A] and [B]). Step 5: Additional analysis of any unexpected results. Results: The process categories of the production and handling of Dichloromethane were classified into 12 PROCs, and ten of them were selected to run ECETOC TRA. Modeled values tended to be higher than measured values from both sources. For the measured values from WMP, RCR distribution by PROC was narrow (0.197-0.267, 95% CI) and did not have a relationship with ventilation type, which differs from the tendency of the modeling result. Meanwhile, the measured values from RA for WMP were relatively widely distributed (0.301-1.177, 95% CI) by PROC. In particular PROCs (13,19) were high enough to exceed 1. Also, they become low with better ventilation types and appear differently depending on the ventilation type, similar to the model result. Conclusions: This study revealed that ECETOC TRA might have the potential to serve as a screening tool for exposure assessment and to be used as assistive method for WMP to estimate exposure. Further empirical study is required to confirm its availability as a screening tool.

Accuracy of Digital Breast Tomosynthesis for Detecting Breast Cancer in the Diagnostic Setting: A Systematic Review and Meta-Analysis

  • Min Jung Ko;Dong A Park;Sung Hyun Kim;Eun Sook Ko;Kyung Hwan Shin;Woosung Lim;Beom Seok Kwak;Jung Min Chang
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1240-1252
    • /
    • 2021
  • Objective: To compare the accuracy for detecting breast cancer in the diagnostic setting between the use of digital breast tomosynthesis (DBT), defined as DBT alone or combined DBT and digital mammography (DM), and the use of DM alone through a systematic review and meta-analysis. Materials and Methods: Ovid-MEDLINE, Ovid-Embase, Cochrane Library and five Korean local databases were searched for articles published until March 25, 2020. We selected studies that reported diagnostic accuracy in women who were recalled after screening or symptomatic. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. A bivariate random effects model was used to estimate pooled sensitivity and specificity. We compared the diagnostic accuracy between DBT and DM alone using meta-regression and subgroup analyses by modality of intervention, country, existence of calcifications, breast density, Breast Imaging Reporting and Data System category threshold, study design, protocol for participant sampling, sample size, reason for diagnostic examination, and number of readers who interpreted the studies. Results: Twenty studies (n = 44513) that compared DBT and DM alone were included. The pooled sensitivity and specificity were 0.90 (95% confidence interval [CI] 0.86-0.93) and 0.90 (95% CI 0.84-0.94), respectively, for DBT, which were higher than 0.76 (95% CI 0.68-0.83) and 0.83 (95% CI 0.73-0.89), respectively, for DM alone (p < 0.001). The area under the summary receiver operating characteristics curve was 0.95 (95% CI 0.93-0.97) for DBT and 0.86 (95% CI 0.82-0.88) for DM alone. The higher sensitivity and specificity of DBT than DM alone were consistently noted in most subgroup and meta-regression analyses. Conclusion: Use of DBT was more accurate than DM alone for the diagnosis of breast cancer. Women with clinical symptoms or abnormal screening findings could be more effectively evaluated for breast cancer using DBT, which has a superior diagnostic performance compared to DM alone.