• Title/Summary/Keyword: school zones

Search Result 478, Processing Time 0.027 seconds

A Development of the Integrated Evaluation Criteria for Safety of School Zones (스쿨존 안전성 평가지수 개발)

  • Lee, Soo-Il;Kim, Seung-Hyoun;Kim, Jang-Wook;Hu, Ec
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.1
    • /
    • pp.117-122
    • /
    • 2012
  • In recent years, there have been a number of concerns and measures surrounding 'Traffic Safety' for children. But, actually, safety measurements of 'School Zone' lack. This research thesis was designed to quantify risk degrees of 'School Zone', in a simple way, with the development of evaluation indicators to evaluate risk degrees of 'School Zone'. This is deems to be used for a guideline necessary for devising improvements or safety measures against 'School Zone' in the future. And, this is expected to be useful for managing and controlling safety each local facility about elementary schools.

Evaluation of Electrokinetic Flow Mobility Using Isotacho-Electrophoresis Techniques

  • An, J.H.;Joo, Y.H.;Lee, C.Y.;Lee, Y.J.;Park, C.W.
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.444-448
    • /
    • 2011
  • In the present study, we separated the marker particles from the suspending particle mixture solution using isotacho-electrophoresis technique, a novel quantitative ionic particle separation method, in the microchannel. A multiple stacking zone of the suspending particle was visualized with variations in electric field strength, pH value and concentration of the ionic solution. In particular, the electrophoretic mobility of ionic particle (fluorescein) was estimated based on the electrophoretic velocity value measured by the particle image velocimetry. As a result, isotacho-electrophoresis zones were clearly visualized as going downstream in the electric field. The particle migration velocity increased proportional to the applied voltage increase; it was also affected by the pH value variations in the ionic solution.

Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators

  • Kim, Pil-Jong;Kim, Hong-Gee;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.2
    • /
    • pp.113-122
    • /
    • 2015
  • Objectives: The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL). Materials and Methods: The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC) in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions. Results: Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model. Conclusions: Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.

Analysis of the Characteristics of the Change in the Moisture Rate of Landfill with Recirculation Water Injection (재순환수 주입에 따른 매립장 함수율 변화특성 분석)

  • Kim, Young-Kyu;Choi, Won-Young;Chun, Seung-Kyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.5
    • /
    • pp.39-48
    • /
    • 2021
  • Analysis of the change in water content and distribution was conducted according to the supply of recirculation water to a landfill. An excavation sample analysis showed that the recirculation water injection zone had water content 8.8% point higher than that of the non-injection zone, after 8 months of operation. And due to the influence of recirculation water supply by vertical wells in injection zones, the water content increases along with depth more clearly than non-injection zone. According to an electrical specific-resistivity survey after 13 months of operation, the water content got higher towards the bottom of the landfill. The water transmission coefficient is 8.72×10-4 cm/sec for injection zones and 3.36×10-5 cm/sec for the intermediate cover layer; analysis shows that the intermediate cover layer may affect the penetration velocity of water supplied by the horizontal injection tube. For the scientific design and operation of re-injection facilities, it was deemed necessary to follow-up research on the residence time and behavior of re-injection water considering the ratio of recirculation water supply in horizontal and vertical tubes, and pitcher coefficient of intermediate and waste layers.

Axial behavior of steel reinforced lightweight aggregate concrete columns: Analytical studies

  • Mostafa, Mostafa M.A.;Wu, Tao;Fu, Bo
    • Steel and Composite Structures
    • /
    • v.38 no.2
    • /
    • pp.223-239
    • /
    • 2021
  • This paper presents the analytical modeling and finite element (FE) analysis, using ABAQUS software, of the new types of steel reinforced lightweight aggregate concrete (SRLAC) columns with cross-shaped (+shaped and X-shaped) steel section, using proposed three analytical and two FE models in total. The stress-strain material models for different components in the columns, including the confined zones of the lightweight aggregate concrete (LWAC) using three and four concrete zones divisions approaches and with and without taking into account the stirrups reaction effect, are established first. The analytical models for determining the axial load-deformation behavior of the SRLAC columns are drawn based on the materials models. The analytical and FE models' results are compared with previously reported test results of the axially loaded SRLAC columns. The proposed analytical and FE models accurately predict the axial behavior and capacities of the new types of SRLAC columns with acceptable agreements for the load-displacement curves. The LWAC strength, steel section ratio, and steel section configuration affect the contact stress between the concrete and steel sections. The average ratios of the ultimate test load to the three analytical models and FEA model loads, Put /Pa1, Put /Pa2, Put /Pa3, and Put /PFE1, for the tested specimens are 0.96, 1.004, 1.016, and 1.019, respectively. Finally, the analytical parametric studies are also studied, in terms of the effects of confinement, LWAC strength, steel section ratio, and the reinforcement ratio on the axial capacity of the SRLAC column. When concrete strength, confinements, area of steel sections, or reinforcement bars ratio increased, the axial capacities increased.

Vascular Plants Distributed in the Berchemia berchemiaefolia of Special Protection Zones of Songnisan National Park (속리산국립공원 특별보호구인 망개나무 자생지에 분포하는 관속식물상)

  • Oh, Hyun-Kyung;Kim, Young-Ha;Yun, Sang-Gi
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.3
    • /
    • pp.33-44
    • /
    • 2017
  • This study investigated in the vascular plants of special protection zones (the native land of Berchemia berchemiaefolia in Sadam-ri and Gallon valley) of Songnisan National Park and identified the whole vascular plants. The numbers of vascular plants were summarized as 273 taxa including 82 families, 182 genera, 236 species, 3 subspecies, 28 varieties and 6 forms. Woody plants were identified as 124 taxa (45.4%) and herbaceous plants as 149 taxa (54.6%). A total of 107 taxa were identified in the area of Sadam-ri, and 246 taxa were found in the Gallon valley. A total of 8 taxa of rare plants were identified, each of which was divided into 1 taxa of endangered (EN; Daphne pseudomezereum var. koreana), 3 taxa of vulnerable (VU; Paeonia japonica, Berchemia berchemiaefolia and Iris minutiaurea), 3 taxa of least concern (LC; Aristolochia contorta, Syringa patula var. kamibayshii and Goodyera schlechtendaliana) and 1 taxa of data deficient (DD; Alangium platanifolium). The Korean endemic plants were 9 taxa (Clematis trichotoma, Thalictrum actaefolium var. brevistylum, Aster koraiensis, Cirsium setidens, etc.). In the specific plants by floristic region were 34 taxa, a degree I were 17 taxa (Chloranthus japonicus, Celastrus stephanotifolius, etc.), 9 taxa of a degree II (Euonymus pauciflorus, Acer triflorum, etc.), 4 taxa of a degree III (Aconitum longecassidatum, Angelica gigas, etc.), 2 taxa of a degree IV (Ulmus macrocarpa and Daphne pseudomezereum var. koreana), 2 taxa of a degree V (Berchemia berchemiaefolia and Alangium platanifolium). The naturalized plants were 5 taxa including Fallopia dumetorum, Trifolium repens, Ailanthus altissima, Oenothera biennis, Erigeron annuus. Naturalization rate (NR) was 1.8% of all 273 taxa of vascular plants and the invasive alien plants were not found. The purpose of this study is to identify the flora that grows in the special protection zones of Songnisan National Park and provide the basic data for the management of the special protection zone in the future.

A Study on the Classification Criteria of Climatic Zones in Korean Building Code Based on Heating Degree-Days (난방도일 기반 대한민국 행정구역별 기후존 구분 기준 정립에 관한 연구)

  • Noh, Byeong Il;Choi, Jaewan;Seo, Donghyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.11
    • /
    • pp.574-580
    • /
    • 2015
  • Climatic zone in building code is an administrative district classification reflecting regional climatic characteristics. Use of Degree-Days is a fundamental method that can be used in various building design codes, analysis of building energy performance, and establishment of minimum thermal transmittance of building envelopes. Many foreign countries, such as the USA, the EU, Australia, Italy, India, China, etc., have already adapted climatic zone classification with degree-days, precipitation or amount of water vapor based on the characteristics of their own country's climate. In Korea, however, the minimum requirements for regional thermal transmittance are classified separately for the Jungbu area, Nambu area and Jeju Island with no definite criterion. In this study, degree-days of 255 Korean cities were used for climatic zone classification. Outdoor dry-bulb temperature data from the Korea Meteorological Administration for 1981~2010 was used to calculate degree-days. ArcGIS and the calculated degree-days were utilized to analyze and visualize climatic zone classification. As a result, depending on the distribution and distinctive differences in degree-days, four climatic zones were derived : 1) Central area, 2) Mountain area of Gyeonggi and Gangwon provinces, 3) Southern area, and 4) Jeju Island. The climatic zones were suggested per administrative district for easy public understanding and utilization.

Vegetational History of the Mulyeongari Fen by Pollen Analysis in Jeju Island, Korea (제주도 물영아리늪 퇴적물의 화분분석에 의한 식생변천)

  • Lee, Chang-Su;Kang, Sang-Joon;Choi, Kee-Ryong
    • Journal of Environmental Science International
    • /
    • v.20 no.3
    • /
    • pp.341-350
    • /
    • 2011
  • For the reconstruction of the past vegetational changes in Jeju Island, Korea, pollen analysis and radiocarbon dating on the sediments obtained from the Mulyeongari fen were carried out. By the results, the vegetational changes around the Mulyeongari fen from ca. 3,300 cal. yr BP to the present can be interpreted and reconstructed. The pollen record from the Mulyeongari fen was divided into two local pollen assemblage zones and three sub-pollen assemblage zones. Zone I (Quercus-Carpinus-Herbs Zone) was characterized by the predominance of Quercus(30~63%), Carpinus(9~35%) and herbs(40~424%). Zone II was characterized by three sub-pollen assemblage zones and the high occurrence ratio of the tree layer in comparison with Zone I. In Zone IIa (Quercus-Carpinus Zone), herbs(3~161%) were drastically decreased in predominance of Quercus(28~56%) and Carpinus(14~31%). In Zone IIb (Carpinus-Quercus Zone), Carpinus(36~48%) was preferentially increased but Quercus(29~39%) was slightly decreased. In Zone IIc (Quercus-Carpinus Zone), Carpinus(26~38%) was decreased inversely but Quercus(36~50%) was increased. In addition, Cyperaceae was also increased to 52%. Consequently, it is suggested that cool temperate southern/sub-montane vegetation composed of Quercus and Carpinus which was physiognomy of deciduous broad leaved forest was distributed around the Mulyeongari fen from ca. 3,300 cal. yr BP. In addition, Cyclobalanopsis(4~23%), Castanopsis(1~12%) and Myrica(under 1%) which are warm-temperate evergreen deciduous forest components were constantly appeared from this period. Accordingly, it can be inferred that the present vegetation type around the Mulyeongari fen was formed from ca. 180 cal. yr BP.

Zoning Suitability Analysis to Reduce First-flush Runoff Contamination in a Separated Sewer System (분류식 하수지역의 초기 유출수 오염저감을 위한 용도지구별 적지 분석)

  • Park, In-Hyeok;Ha, Sung-Ryong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.11 no.2
    • /
    • pp.13-27
    • /
    • 2008
  • This paper aim to reorganize zoning areas for decreasing first-flush runoff contamination in a separated sewer system via suitability analysis, and to simulate the discharge pollution loads of first-flush runoff using SWMM. For these purposes, diffuse pollution, which is accumulated on a surface and first-flush runoff flow were investigated. Suitability conditions for zoning were defined using the results of these investigation and suitable zoning areas were analyzed for the each condition. AHP analysis was conducted to establish weights of the suitability conditions. The most suitable zoning areas were analyzed via overlaying weights and suitability conditions. From the result, it was noted that the most suitable zones for detached houses & apartments are location they already occupied. Some school areas analyzed were found to be suitable as commercial centers. Some zones within the area analyzed were found to be suitable for commercial zones. From results obtained from simulation, the zone re-organization showed BOD and SS concentration to reduce from 91.2% to 0.09% ans 72.74% to 0.31% respectively.

  • PDF

Effect of Deformation Zones on the State of In Situ Stress at a Candidate Site of Geological Repository of Nuclear Waste in Sweden (스웨덴 방사성 폐기물 처분장 후보부지의 사례를 통해 살펴본 대규모 변형대가 암반의 초기응력에 미치는 영향)

  • Min, Ki-Bok
    • Tunnel and Underground Space
    • /
    • v.18 no.2
    • /
    • pp.134-148
    • /
    • 2008
  • The state of in situ stress is an important factor in considering the suitability of a site as a geological repository for nuclear waste. In this study, three-dimensional distinct numerical analysis was conducted to investigate the effect of deformation zones on the state of stress in the Oskarshamn area, which is one of two candidate sites in Sweden. A discontinuum numerical model was constructed by explicitly representing the numerous deformation zones identified from site investigation and far-field tectonic stress was applied in the constructed model. The numerical model successfully captured the variation of measured stress often observed in the rock mass containing large-scale fractures, which shows that numerical analysis can be an effective tool in improving the understanding of the state of stresses. Discrepancies between measured and modelled stress are attributed to the inconsistent quality of measured stress, uncertainty in geological geometry. and input data for fractures.