• Title/Summary/Keyword: scanner

검색결과 2,060건 처리시간 0.027초

룩업테이블을 이용한 스캐너 캘리브레이션에 관한 연구 (A Study on the Scanner Calibration Method Using Look-up Table)

  • 신춘범;강상훈
    • 한국인쇄학회지
    • /
    • 제20권1호
    • /
    • pp.79-90
    • /
    • 2002
  • Recently, the research about color matching for the input/output devices of printing process is progressing rapidly by the digitization. The calibration method of flatbed scanner widely used as an input device for prepress process is especially important for color proofing of high quality color prints. In this paper, scanner calibration method using 3-dimensional look-up table and tetrahedral interpolation was examined and analysed comparatively on the three kinds of original copies, such as photograph, dye sublimation proof and ink jet print for IT8.T/2 target.

  • PDF

스캐너 이미지 기반 ISO 13660 및 컬러 품질 항목 평가 (Evaluating Printing Quality Based on ISO 13660 and Color Criteria Using Scanner Images)

  • 황태윤;이준호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.1011-1012
    • /
    • 2008
  • Image quality analysis has been carried out for both monochrome and colour print images obtained by a calibrated low-end scanner. The analysis method is based upon ISO13660 for monochrome images and additional criteria for colour quality that we have defined. We have compared performance of the calibrated scanner with that of a high-end spectrophotometer in terms of several aspects such as line and large area. They have provided similar results without significant discrepancy.

  • PDF

3D Scanner를 이용한 foundation 착용시의 인체 변화 계측 (Body Shape Variations Measurements with 3D Scanner for Wearing Foundation)

  • 박지은;김희은
    • 한국의류산업학회지
    • /
    • 제9권6호
    • /
    • pp.651-657
    • /
    • 2007
  • This study was carried out to analyse body configuration and to observe any space between skin and foundation. A special 3D scanner was used to analyze this foundation. Experimental foundations were brassiere, girdle, and all-in-one. Four subjects volunteered, each subject was scanned while wearing foundation and not wearing foundation. Body shape variations were analyzed with an Auto CAD and ScanWax program which analyzes cross section of the skin surface to look for any changes. Height was increased all parts of body, circumference was increased in breast and bust while wearing the foundation. The hip thickness was not increased with wearing the foundation. Therefore this foundation makes people have a different appearance due to unexpected body shape variations. The effects of this foundation should be classified by observing height, circumference, and thickness changes in the body.

거울 및 단일 카메라를 이용한 3차원 발 스캐너 (A 3D Foot Scanner Using Mirrors and Single Camera)

  • 정성엽;박상근
    • 한국CDE학회논문집
    • /
    • 제16권1호
    • /
    • pp.11-20
    • /
    • 2011
  • A structured beam laser is often used to scan object and make 3D model. Multiple cameras are inevitable to see occluded areas, which is the main reason of the high price of the scanner. In this paper, a low cost 3D foot scanner is developed using one camera and two mirrors. The camera and two mirrors are located below and above the foot, respectively. Occluded area, which is the top of the foot, is reflected by the mirrors. Then the camera measures 3D point data of the bottom and top of the foot at the same time. Then, the whole foot model is reconstructed after symmetrical transformation of the data reflected by mirrors. The reliability of the scan data depends on the accuracy of the parameters between the camera and the laser. A calibration method is also proposed and verified by experiments. The results of the experiments show that the worst errors of the system are 2 mm along x, y, and z directions.

임상가를 위한 특집 3 - 여러 보철 치료 술식에 따른 바른 스캐닝 과정과 구강스캐너의 활용 (Suitable scanning procedures for various prosthodontic treatments and the utilization of intraoral scanner)

  • 박지만;박은진;허성주
    • 대한치과의사협회지
    • /
    • 제52권6호
    • /
    • pp.354-362
    • /
    • 2014
  • With the development of digital dentistry, various intra-oral scanners which acquire intraoral image without conventional impression taking and stone pouring steps have been introduced. Fixed dental prostheses such as inlay, onlay, crown, and bridge fabricated by CAD/CAM technique combined with digital impressions is getting popular due to the recent rapid progress of digital impression taking system. In comparison with traditional prosthetic procedure, the advantages of intraoral image acquiring and CAD/CAM technique are as follows; the omission of conventional impression materials, reduced workflow step, and increased efficiency by online communication with clinic and laboratory. This review article covers some opinions about the suitable scanning procedures for the various prosthodontic treatments and the utilization of digital intraoral scanner and CAD/CAM system.

열간압연용 롤 정밀 측정시스템 개발 (Development of Precise Measuring System for Hot Strip Mill's Rolls)

  • 이성진;이영진
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.614-618
    • /
    • 2002
  • In hot strip mills, Portable Roll Scanner (the portable roll surface temperature and profile measuring device) can be used to calibrate on-line Process models for strip crown and flatness by measuring the thermal expansion and wear profile of the rolls. And the surface temperature measurement can be used to optimize the roll cooling system. Portable Roll Scanner consists of the measuring device, which has two contact inductive distance transducers for roll profile measurement and one infrared Pyrometer for surface temperature measurement, and computer-based controller that is equipped with the measuring device. By the wireless data communication, the data is transferred to the memory of notebook for further analysis. After roll extraction from mills, Portable Roll Scanner measure the roll profile and surface temperature simultaneously along the work roll face and display the results in the TFT color monitor of notebook. Portable Roll Scanner is useful at mill-side and roll grinding shop.

  • PDF

충격에 강인한 폴리곤 미러 스캐너 모터의 판 스프링 설계 (Robust Design of Leaf Spring of a Polygon Mirror Scanner Motor Against Shock)

  • 이상욱;김명규;정경문;장건희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.515-520
    • /
    • 2008
  • This paper develops a mite element model of a polygon mirror scanner motor supported by the sintered bearing and flexible supporting structures to analyze the shock response by using the finite element method and the mode superposition method. The validity of the proposed model is verified by comparing the simulated natural frequencies and shock response with the experimental ones. It investigates the displacement and the stress of the most vulnerable component, i.e. a leaf spring due to shock, and it proposes a robust design of leaf spring of a polygon mirror scanner motor against shock.

  • PDF

Study on the Reconstruction of Skull Prototype using CT image and Laser Scanner

  • Hur, Sung-Min;Lee, Seok-Hee
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제1권1호
    • /
    • pp.146-151
    • /
    • 2000
  • The importance of shape reconstruction is increasing in many areas such as RPD(Rapid Product Development) and reverse engineering. Typical data in these areas are mainly classified as the shape data measured by a laser scanner and the data extracted from the CT image. The goal of this research is to realize three-dimensional shape construction by showing a possible way to analyze input image data and reconstruct the original shape. Two main steps of the reconstructing process are obtaining cross-section data from image processing and linking loops between one slice and the next. Objects reconstructed in this way are compared with other objects using a laser scanner and modelled by commercially available software. The technique is expected to be used in reverse engineering applications and the object modeling with automated process.

  • PDF

SIL 인증을 위한 FMEDA 프로세스 연구 : 화염검출기 사례를 중심으로 (A Study on FMEDA Process for SIL Certification : A Case Study of a Flame Scanner)

  • 김성규;김용수
    • 산업공학
    • /
    • 제25권4호
    • /
    • pp.422-430
    • /
    • 2012
  • In this article, we introduced the estimation method by 'Safety Integrity Level'(SIL) for the criterion of safety assurance and performed a case study on a flame scanner. SIL requires probabilistic evaluation of each set of equipment used to reduce risk in a safety related system. FMEDA(Failure Modes, Effects and Diagnostic Analysis) method is widely used to evaluate the safety levels and provides information on the failure rates and failure mode distributions necessary to calculate a diagnostic coverage factor for a part or a component. Basically, two parameters resulting from FMEDA are used for SIL classification of the device : SFF(Safe Failure Fraction) and PFD(Probability of Failure on Demand). In this case study, it is concluded that the flame scanner is designed to fulfill the condition of SIL 3 in the aspect of SFF and PFD.

분할된 색공간에서 비선형 다중회귀분석법을 이용한 스캐너 켈리브레이션에 관한 연구 (A study on scanner calibration method using nonlinear regression analysis in sub-divided color space)

  • 김나나;구철회
    • 한국인쇄학회:학술대회논문집
    • /
    • 한국인쇄학회 2000년도 추계학술발표회 논문집
    • /
    • pp.0.2-0
    • /
    • 2000
  • Most important step for the color matching in scanner is the color coordinate transformation from the scanner RGB space to device independent uniform color space. A variety of color calibration technologies have been developed for input device. Linear or nonlinear matrices have been conveniently applied to correct the color filter\`s mismatch with color matching function in scanners. The color matching accuracy is expected to be further improved when the nonlinear matrices are optimized into subdivided smaller color spaces than in single matrix of the entire color space. This article proposed the scanner calibration method using subspace division regression analysis and it were compared with conventional method.

  • PDF