• Title/Summary/Keyword: scan time

Search Result 1,248, Processing Time 0.032 seconds

An AP Selection Scheme for Enhancement of Multimedia Streaming in Wireless Network Environments (무선 네트워크 환경에서 멀티미디어 서비스를 위한 AP 선정 기법)

  • Ryu, Dong-Woo;Wang, Wei-Bin;Kang, Kyung-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.997-1005
    • /
    • 2010
  • Recently, there has been a growing interest in the use of WLAN technology due to its easy deployment, flexibility and so on. Examples of WLAN applications range from standard internet services such as Web access to real-time services with strict latency/throughput requirements such as multimedia video and voice over IP on wireless network environments. Fair and efficient distribution of the traffic loads among APs(Access Points) has become an important issue for improved utilization of WLAN. This paper focuses on an AP selection scheme for achieving better load balance, and hence increasing network resource utilization for each user on wireless network environments. This scheme makes use of active scan patterns and the network delay as main parameters of load measurement and AP selection. This scheme attempts to estimate the AP traffic loads by observing the up/down delay and utilize the results to maximize the link resource efficiency through load balancing. We compared the proposed scheme with the original SNR(Signal to Noise Ratio)-based scheme using the NS-2(Network Simulation.2). We found that the proposed scheme improves the throughput by 12.5% and lower the network up/down link delay by 36.84% and 60.42%, respectively. All in all, the new scheme can significantly increase overall network throughput and reduce up/down delay while providing excellent quality for voice and video services.

CT Observation of Alloplastic Materials Used in Blow Out Fracture (안와골절 정복술에 사용된 인공삽입물의 전산화단층촬영 추적관찰)

  • Lee, Won;Kang, Dong-Hee
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.380-384
    • /
    • 2010
  • Purpose: Distinguishing different types of implants and assessing the position and size of implants by radiologic exam after orbital wall reconstruction is important in determining the surgery outcome and forecasting prognosis. We observed time-dependent density changes in three types of implants (porous polyethylene, resorbing plate and titanium mesh plate) by performing facial bone CT after orbital wall reconstructions. Methods: A total of 32 patients, who had underwent orbital wall fracture surgery from October 2006 to March 2009 and received facial bone CT as outpatients at 1 postoperative year were included in the study. Follow-up facial bone CT was performed on the patients pre- operatively, 1 month post-operatively, and 1 year post-operatively to observe the status of the orbital implants. Medpor $^{(R)}$ (Porex Surgical, Inc., Newnan, Ga.) was used as porous polyethylene and followed-up in 14 cases; for resorbing plate, Synthes mesh plate (Synthes, Oberdorf, Switzerland) was used in the reconstruction, and followed-up in 11 cases; and titanium mesh plate usage was followed-up in 7 cases. Computed tomographic scan (CT) and water's view were done for radiography, and hounsfield unit (HU) was used to compare density of those facial bone CT. Wilcoxon signed rank test was applied to statistically verify measurement difference in each group of hounsfield units. Results: Facial bone CT examination performed in 1 month post-operative showed that the density of porous polyethylene, resorbing plate and titanium mesh plate were -42.07, 105.67 and 539.48 on average, respectively. Among the three types of implants, titanium mesh plate showed the highest density due to its radiopaque feature. Following up the density of three types of implants in CT during 1 year after the orbital wall fracture surgery, the density of porous polyethylene increased in 10.52 House Field Units and the resorbing plate was decreased in 26.87 HouseField Units. There were no significant differences between densities in 1 month post-operatively and 1 year post-operatively in each group ($p{\geq}0.05$). Conclusion: We performed facial bone CT on patients with orbital fractures during follow-up period, distinguishing the types of implants by the different concentration of implant density, and the densities showed little change even at 1 year post-operative. To observe how implant densities change in facial bone CT, further studies with longer follow-up periods should be carried out.

Duration of Regain of Deep Pain Perception after Decompression Surgery as a Parameter of Surgical Outcome for Acute Thoracolumbar Disc Herniation Hansen Type I with Loss of Deep Pain Perception in Dogs

  • Park, Sung-Su;Lim, Ji-Hey;Byeon, Ye-Eun;Jang, Byung-Jun;Ryu, Hak-Hyun;Uhm, Ji-Yong;Kang, Byung-Jae;Kim, Wan-Hee;Kweon, Oh-Kyeong
    • Journal of Veterinary Clinics
    • /
    • v.25 no.6
    • /
    • pp.529-532
    • /
    • 2008
  • The object of this study was to evaluate the durations from onset of neurological sign until surgery and regaining of the deep pain perception (DPP) after decompression as prognostic indicators for the outcome of decompression surgery in dogs with thoracolumbar intervertebral disc disease (IVDD). The compression lesions in the thoracolumbar vertebrae were localized by plain radiograph, computed tomography and neurological examination in 28 dogs with hindlimb paralysis. The follow up was carried out for 6 months after laminectomy. During the follow up, regaining DPP and walking ability were evaluated. Improvement to normal or paretic gait after surgery was judged as success of the surgical treatment.The success rate of surgical treatment was 70 % (7 out of 10 dogs) when surgical intervention was carried out within 24 hours but 38.9 % (7 out of 18) over 24 hours (P<0.05). The success rate of surgical treatment was 87.5 % (14 out of 16 dogs) when DDP was regained within 5 weeks after surgery but there was 0 % (0 out of 12 dogs) when DDP was not regained within 5 weeks after surgery (P<0.05). Other parameters such as compression rate in CT scan and laminectomy methods did not related with the success of the surgery. These results suggested that the time of surgery after onset and duration of regaining of DPP after decompression were useful parameter to predict the success of surgical treatment for thoracolumbar disc herniation in dogs.

Evaluation of QC Value Variation and Overlapping Use According to Aging of 57Co Sealed Source (57Co 밀봉선원의 노후도에 따른 균일도의 변동과 중첩사용에 관한 유용성 평가)

  • Lee, Jong-Hun;Cho, Sung-kil;Shim, Dong-Oh
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.50-53
    • /
    • 2017
  • Purpose The change in uniformity due to the decreasement in dose should be known. $^{57}Co$ sealed sources are easy to manage and use as QC sources replacing $^{99m}Tc$. Overlapping sealed sources are expected to show variations in dose due to attenuation between sealed sources. Materials and Methods A total of three experiments were conducted. The first experiment is to observe the change in the degree of senescence of the $^{57}Co$ sealed source. The second experiment is to compare the single source and overlaped source at similar doses. In the third experiment, the sources of different doses were compared on each other to determine the changes due to the attenuation between the overlapping sources. Results The results of the first experiment did not exceed the acceptable range. but each crew showed a difference. There was no statistically significant difference in the measurement of uniformity on second and third experiment Conclusion It is believed that a $^{57}Co$ sealed source can be used as a superimposed source. It is not only economical but also convenient to use. daily uniformity measurements will help reduce scan time and speed up the testing process.

  • PDF

Characterization of Water Absorption by CFRP Using Air-Coupled Ultrasonic Testing (공기결합 초음파탐상에 의한 CFRP 복합재의 흡습 특성 평가)

  • Lee, Joo-Min;Lee, Joo-Sung;Kim, Yong-Kwon;Park, Ik-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.2
    • /
    • pp.155-164
    • /
    • 2014
  • Carbon-fiber-reinforced plastic (CFRP) composites are increasingly being used in a variety of industry applications, such as aircraft, automobiles, and ships because of their high specific stiffness and high specific strength. Aircraft are exposed to high temperatures and high humidity for a long duration during flights. CFRP materials of the aircraft can absorb water, which could decrease the adhesion strength of these materials and cause their volumes to change with variation in internal stress. Therefore, it is necessary to estimate the characteristics of CFRP composites under actual conditions from the viewpoint of aircraft safety. In this study air-coupled ultrasonic testing (ACUT) was applied to the evaluation of water absorption properties of CFRP composites. CFRP specimens were fabricated and immersed in distilled water at $75^{\circ}C$ for 30, 60, and 120 days, after which their ultrasonic images were obtained by ACUT. The water absorption properties were determined by quantitatively analyzing the changes in ultrasonic signals. Further, shear strength was applied to the specimens to verify the changes in their mechanical properties for water absorption.

Slit Ventricle Syndrome in Children : Clinical Presentation and Treatment (소아에서 틈새뇌실 증후군 : 임상 양상 및 치료)

  • Shin, Beom-Sik;Yang, Kook-Hee;Kim, Dong-Seok;Choi, Joong-Uhn
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.309-315
    • /
    • 2001
  • The term slit ventricle syndrome(SVS) refers to an episodic occurrence of headache, vomiting, and possibly some degree of impaired consciousness in shunted hydrocephalic children in whom slit-like ventricles are seen on CT scan or MRI. Authors present 6 cases with SVS who were treated at our institute for last 10 years. From 1986 to 1996, 821 patients underwent shunt surgery for hydrocephalus. The etiology of hydrocephalus included brain tumor(140 patients), post-hemorrhagic(62 patients), idiopathic normotensive hydrocephalus(64 patients), post-meningitic( 58 patients), post-traumatic(54 patients), congenital(48 patients), neurocysticercosis(31 patients), and unknown etiology(364 patients). During the mean follow-up duration of 68 months, 232 shunt revisions were performed by a revision rate of 1.28 per patient. The incidence of SVS was 0.7%(6 patients). Most of them have been operated on in infancy. Time interval from the first operation to the development of slit-ventricle syndrome ranged from 4 to 8 years, the mean was 6 years. Shuntogram showed patent shunt in all patients. Two patients with less severe clinical symptoms improved with conservative treatment. These patients were not measured ICP because of good hospital course. One patient showed high ICP and needed only revision with same pressure valve as previous shunt. Low ICP was noted in 3 patients. Pressure augmentation using an anti-siphon device(ASD) or upgrading valve system were necessary in these patients. The authors stress that determining type of SVS is the first step in treatment planning and that the best treatment is a strategy aimed at resolving the specific type of SVS responsible for the symptoms.

  • PDF

Effect of Light Transmission on Composition and Somatic Cell count of Raw Milk (분광된 빛의 주사가 원유내 성분에 미치는 영향)

  • Ko, Han-Jong;Kim, Ki-Youn;Min, Young-Bong;Nishizu, Takahisa;Yun, Yong-Chul;Kim, Hyeon-Tae
    • Journal of agriculture & life science
    • /
    • v.46 no.1
    • /
    • pp.189-194
    • /
    • 2012
  • Measurement of compositions and somatic cells in raw milk by chemical methods usually requires a lot of time, skilled labor and expensive analytical equipments. Recently, near-infrared reflectance spectroscopy (NIRS), which is a rapid, cost-effective and non-destructive technique, has been extensively used for safety and quality evaluation in the field of dairy products. However, less study has been performed to evaluate the effect of transmitted light on milk quality during NIRS analysis. Therefore, the objective of this study was to analyze the changes in milk quality using transmitted light. Raw milk samples collected from dairy farm from Siga prefecture in Japan were analyzed for fat, protein, lactose, solids not fat, total solids, milk urea and citric acid using the Milko scan 4000. Somatic cells in raw milk samples were counted by the Fossomatic 5000. Transmittance spectra of 50 ml raw milk samples were obtained by the Lax-Cute lighter in the 400 nm or less, 689 nm, 773 nm, 900 nm and 979 nm. As a result, milk fat as well as somatic cell count was increased by 2.6% and 9.0%, respectively. The other compositions were, however, changed within the relative error of the measurement. Further studies are needed to apply raw milk quality evaluation using the UV band by accumulating more samples and more data.

An Improved Validation Technique for the Temporal Discrepancy when Estimated Solar Surface Insolation Compare with Ground-based Pyranometer: MTSAT-1R Data use (표면도달일사량 검증 시 발생하는 시간 불일치 조정을 통한 정확한 일사량 검증: MTSAT-1R 자료 이용)

  • Yeom, Jong-Min;Han, Kyung-Soo;Lee, Chang-Suk;Kim, Do-Yong
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.6
    • /
    • pp.605-612
    • /
    • 2008
  • In this study, we estimate solar surface insolation (SSI) by using physical methods with MTSAT-1R data. SSI is regarded as crucial parameter when interpreting solar-earth energy system, climate change, and agricultural production predict application. Most of SSI estimation model mainly uses ground based-measurement such as pyranometer to tune the constructed model and to validate retrieved SSI data from optical channels. When compared estimated SSI with pyranometer measurements, there are some systemic differences between those instruments. The pyranometer data observed upward-looking hemispherical solid angle and distributed hourly measurements data which are averaged every 2 minute instantaneous observation. Whereas MTSAT-1R channels data are taken instantaneously images at fixed measurement time over scan area, and are pixel-based observation with a much smaller solid angle view. Those temporal discrepancies result from systemic differences can induce validation error. In this study, we adjust hour when estimate SSI to improve the retrieved accurate SSI.

Defining the Tumour and Gross Tumor Volume using PET/CT : Simulation using Moving Phantom (양전자단층촬영장치에서 호흡의 영향에 따른 종양의 변화 분석)

  • Jin, Gye-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.935-942
    • /
    • 2021
  • Involuntary movement of internal organs by respiration is a factor that greatly affects the results of radiotherapy and diagnosis. In this study, a moving phantom was fabricated to simulate the movement of an organ or a tumor according to respiration, and 18F-FDG PET/CT scan images were acquired under various respiratory simulating conditions to analyze the movement range of the tumor movement by respiration, the level of artifacts according to the size of the tumor and the maximum standardized uptake value (SUVmax). Based on Windows CE 6.0 as the operating system, using electric actuator, electric actuator positioning driver, and programmable logic controller (PLC), the position and speed control module was operated normally at a moving distance of 0-5 cm and 10, 15, and 20 reciprocations. For sphere diameters of 10, 13, 17, 22, 28, and 37 mm at a delay time of 100 minutes, 80.4%, 99.5%, 107.9%, 113.1%, 128.0%, and 124.8%, respectively were measured. When the moving distance was the same, the difference according to the respiratory rate was insignificant. When the number of breaths is 20 and the moving distance is 1 cm, 2 cm, 3 cm, and 5 cm, as the moving distance increased at the sphere diameters of 10, 13, 17, 22, 28, and 37 mm, the ability to distinguish images from smaller spheres deteriorated. When the moving distance is 5 cm compared to the still image, the maximum values of the standard intake coefficient were 18.0%, 23.7%, 29.3%, 38.4%, 49.0%, and 67.4% for sphere diameters of 10, 13, 17, 22, 28, and 37 mm, respectively.

Evaluation of Surgical Completeness in Endoscopic Total Thyroidectomy with Central Neck Dissection via a Unilateral Axillo-Breast Approach Compared with Bilateral Axillo-Breast and Open Approach (양측 액와유방 접근법과 개방성 접근법과의 비교를 통한 일측 액와유방 접근 내시경 갑상선 전 절제술과 중심 경부 절제술의 수술적 완전성에 대한 평가)

  • Choi, Ik Joon;Lim, Ilhan;Lee, Byeong-Cheol;Lee, Guk Haeng;Lee, Myung-Chul
    • Korean Journal of Otorhinolaryngology-Head and Neck Surgery
    • /
    • v.61 no.12
    • /
    • pp.697-701
    • /
    • 2018
  • Background and Objectives The aim of this study was to evaluate surgical completeness in endoscopic total thyroidectomy with central neck dissection via unilateral axillo-breast approach (UABA) compared with bilateral axillo-breast (BABA) and open approach (OA) by means of the radioactive iodine uptake (RAIU) ratio and thyroglobulin (Tg) of remnant thyroid. Subjects and Method From July 2010 to March 2013, 82 patients who had underwent total thyroidectomy with central neck dissection and postoperative radioactive iodine (RAI) ablation for papillary thyroid carcinoma were enrolled. Of these patients, 27 patients underwent UABA, 24 patients BABA, and 31 patients OA. Clinicopathologic data, surgical outcome, stimulated Tg and RAIU ratio on the first postoperative RAI ablation scan were compared among 3 groups. Results Patients in the endoscopic surgery groups (UABA, BABA) were younger than those in the OA groups. Invasiveness such as operation time, postoperative pain, and drain amount in UABA was less than that in BABA and severer than that in OA. Other variables regarding clinicopathologic and surgical data were not significantly different. Stimulated Tg and RAIU ratio did not show significant differences among 3 groups (p=0.659 and p=0.664). Conclusion The completeness of UABA was comparable with that of BABA and OA. The UABA may be a safe option for patients who need endoscopic thyroidectomy for papillary thyroid carcinoma.