• Title/Summary/Keyword: scan rate

Search Result 729, Processing Time 0.033 seconds

Phase Image Analysis in Conduction Disturbance Patients (심실내 전도장애 환자에서의 $^{99m}Tc$-RBC Gated Blood-Pool Scintigraphy을 통한 Phase Image Analysis)

  • Kwak, Byeng-Su;Choi, Si-Wan;Kang, Seung-Sik;Park, Ki-Nam;Lee, Kang-Wook;Jeon, Eun-Seok;Park, Chong-Hun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.44-51
    • /
    • 1994
  • It is known that the normal His-Purkinje system provides for nearly synchronous activation of right (RV) and left (LV) ventricles. When His-Purkinje conduction is abnormal, the resulting sequence of ventricular contraction must be correspondingly abnormal. These abnormal mechanical consequences were difficult to demonstrate because of the complexity and the rapidity of it's events. To determine the relationship of the phase changes and the abnormalities of ventricular conduction, we performed phase image analysis of $^{99m}Tc$-RBC gated blood pool scintigrams in patients with intraventricular conduction disturbances (24 complete left bundle branch block (C-LBBB), 15 complete right bundle branch block (C-RBBB), 13 Wolff-Parkinson-White syndrome (WPW), 10 controls). The results were as follows; 1) The ejection fraction (EF), peak ejection rate (PER), and peak filling rate (PFR) of LV in gated blood pool scintigraphy (GBPS) were significantly lower in patients with C-LBBB than in controls ($44.4{\pm}13.9%$ vs $69.9{\pm}4.2%,\;2.48{\pm}0.98$ vs $3.51{\pm}0.62,\;1.76{\pm}0.71$ vs $3.38{\pm}0.92$, respectively, p<0.05). 2) In the phase angle analysis of LV, Standard deviation (SD), width of half maximum of phase angle (FWHM), and range of phase angle were significantly increased in patients with C-LBBB than in controls ($20.6{\pm}18.1$ vs $8.6{\pm}1.8,\;22.5{\pm}9.2$ vs $16.0{\pm}3.9,\;95.7{\pm}31.7$ vs $51.3{\pm}5.4$, respectively, p<0.05). 3) There was no significant difference in EF, PER, PFR between patients with the Wolff-parkinson-White syndrome and controls. 4) Standard deviation and range of phase angle were significantly higher in patients with WPW syndrome than in controls ($10.6{\pm}2.6$ vs $8.6{\pm}1.8$, p<0.05, $69.8{\pm}11.7$ vs $51.3{\pm}5.4$, p<0.001, respectively), however, there was no difference between the two groups in full width of half maximum. 5) Phase image analysis revealed relatively uniform phase across the both ventricles in patients with normal conduction, but markedly delayed phase in the left ventricle of patients with LBBB. 6) In 13 cases of WPW syndrome, the site of preexcitation could be localized in 10 cases (77%) by phase image analysis. Therefore, it can be concluded that phase image analysis can provide an accurate noninvasive method to detect the mechanical consequences of a wide variety of abnormal electrical activation in ventricles.

  • PDF

The Consideration of the Region of Interest on $^{99m}Tc$-DMSA Renal Scan in Pediatric Hydronephrosis Patients (수신증을 진단 받은 소아 환자의 DMSA 신장 검사에서 정확한 관심영역 설정에 대한 고찰)

  • NamKoong, Hyuk;Lee, Dong-Hyuk;Oh, Shin-Hyun;Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.27-33
    • /
    • 2012
  • Purpose: Most of diagnosis in the pediatric hydronephrosis patients have been performed $^{99m}Tc$-DMSA renal scan. Then the region of interest (ROI) is set for comparative analysis of uptake ratio in left-right kidney after acquiring the image. But if the equipment set an automatic ROI, the ROI could include expanded renal pelvis due to hydronephrosis and the uptake ratio of left-right kidney will be incorrect result. Therefore this study compared both ROIs including expanded renal pelvis and excluding renal pelvis through experiment using normal kidney phantom and expanded renal pelvis phantom and suggested setting method of improved ROI. In addition, this study have been helped by readout doctor for investigate distinction radiopharmaceutical uptake between renal cortex and remained urine by expanded renal pelvis. Materials and Methods: The both of renal phantoms were filled with water and shacked with $^{99m}TcO_4$ 111 MBq. In order to describe the expanded renal pelvis, the five latex balloon were all filled with 10 mL water and each of balloon was mixed with $^{99m}TcO_4$ 18.5, 37, 55.5, 74, 92.5 MBq. And we made phantom with fixed $^{99m}TcO_4$activity of 37 MBq and mixed water 5, 10, 15, 20, 25 mL in each balloon. The left kidney was fixed its shape and the right kidney was modified like as hydronephrosis kidney by attached the latex balloons. And the acquiring counts were 2 million. After acquisition, we compared the image of ROI with Expanded renal pelvis and the image of ROI without renal pelvis for analyzing difference in the uptake ratio of left-right kidney and for reproducibility, set the ROI 5 times in the same images. Patients were injected $^{99m}Tc$-DMSA 1.5~1.9 MBq/kg and scanned 3 to 4 hours after injection. The each of 3 skillful radio technologists performed the comparing estimation by setting ROI. To determine statistical significance between two data, SPSS (ver. 17) Wilcoxon Signed Ranks Test was used. Results: As a result of renal phantom's experiment, we compared with average of counts Background (BKG) ratios in the setting of ROI including expanded renal pelvis and setting of excluding expanded renal pelvis. Therefore, they can obtain changed counts and changed ratios. Patient also can obtain same results. In addition, the radiopharmaceutical uptake in expanded renal pelvis was come out the remained urine that couldn't descend to ureter by the help of readout doctor. Conclusion: As above results, the case of setting ROI including expanded renal pelvis was more abnormally increasing uptake ratio than the case of setting ROI excluding expanded renal pelvis in analysis the uptake ratio in left-right kidney of hydronephrosis. Because of the work convenience and prompted analysis, the automatic ROI is generally used. But in case of the hydronephrosis study, we should set the manual ROI without expanded renal pelvis for an accurate observation of the uptake ratio of left-right kidney since the radiopharmaceutical uptake in expanded renal pelvis is the remained urine.

  • PDF

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

Treatment of Intracranial Meningioma with Linac Based Radiosurgery (뇌수막종에서 선형가속기를 이용한 방사선수술 효과)

  • Kay Chul Seung;Yoon Sei Chul;Chung Su Mi;Ryu Mi Ryung;Kim Yeon Sil;Suh Tae Suk;Choi Kyuho;Son Byung Chul;Kim Moon Chan
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.81-86
    • /
    • 2001
  • Prupose : To evaluate the role of linac based radiosurgery (RS) in the treatment of meningiomas, we retrospectively analyzed the results of clinical and follow up CT/MRI studies. Methods and Materials : From the 1988 July to 1998 April, twenty patients of meningioma had been treated with 6 MV linear accelerator based radiosurgery. Of the 20 patients, four $(20\%)$ were male and 16 $(80\%)$ were female. Mean age was 51 years old ($22\~78$ years old). Majority of intracranial location of tumor for RS were parasagittal and sphenoid wing area. RS was done for primary treatment in 6 $(30\%)$, postoperative residual lesions in 11 $(55\%)$ and regrowth after surgery in 3 $(15\%)$. Mean tumor volume was $5.72\;cm^3\;(0.78\~15.1\;cm^3)$ and secondary collimator size was 2.04 cm $(1\~3\;cm)$. The periphery of tumor margin was prescribed with the mean dose of 19.6 Gy $(9\~30\;Gy)$ which was $40\~90\%$ of the tumor center dose. The follow up duration ranged from 2.5 to 109 months (median 53 months). Annual CT/MRI scan was checked. Results : By the follow up imaging studies, the tumor volume was reduced in 5 cases $(25\%)$, arrested growth in 14 cases $(70\%)$, and increased size in 1 case $(15\%)$. Among these responsive and stable 19 patients by imaging studies, there showed loss of contrast enhancement after CT/MRI in four patients. In clinical response, nine $(45\%)$ patients were considered improved condition, 10 $(50\%)$ patients were stable and one $(5\%)$ was worsened to be operated. This partly resulted in necrosis after surgery. Conclusion : The overall control rate of meningiomas with linac based RS was $95\%$ by both imaging follow-up and clinical evaluation. With this results, linac based RS is considered safe and effective treatment method for meningioma.

  • PDF

A STUDY ON THE GALVANIC CORROSION OF TITANIUM USING THE IMMERSION AND ELECTROCHEMICAL METHOD (침적법과 전기화학법을 이용한 티타늄의 갈바닉 부식에 관한 연구)

  • Kay, Kee-Sung;Chung, Chae-Heon;Kang, Dong-Wan;Kim, Byeong-Ok;Hwang, Ho-Gil;Ko, Yeong-Mu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.584-609
    • /
    • 1995
  • The purpose of this study was to evaluate the difference of the galvanic corrosion behaviour of the titanium in contact with gold alloy, silva-palladium alloy, and nickel-chromium alloy using the immersion and electrochemical method. And the effects of galvallit couples between titanium and the dental alloys were assessed for their usefulness as materials for superstructure. The immersion method was performed by measuring the amount of metal elementsreleased by Inductivey coupled plasma emission spectroscopy(ICPES) The specimen of fifteen titanium plates, the five gold alloy, five silver-palladium, five nickel-chromium plates, and twenty acrylic resin plates ware fabricated, and also the specimen of sixty titanium plugs, the thirty gold alloy, thirty silver-palladium, and nickelc-hromium plugs were made. Thereafter, each plug of gold alloy, silver-palladium, and nickel-chromium inserted into the the titanium and acrylic resin plate, and also titanium plug inserted into the acrylic resin plate. The combination specimens uf galvanic couples immersed in 70m1 artificial saliva solution, and also specimens of four type alloy(that is, titanium, gold, silver-palladium and nickel-chromium alloy) plugs were immersed solely in 70m1 artificial sativa solution. The amount of metal elements released was observed during 21 weeks in the interval of each seven week. The electrochemical method was performed using computer-controlled potentiosta(Autostat 251. Sycopel Sicentific Ltd., U.K). The wax patterns(diameter 11.0mm, thickness,in 1.5mm) of four dental casting alloys were casted by centrifugal method and embedded in self-curing acrylic resin to be about $1.0cm^2$ of exposed surface area. Embedded specimens were polished with silicone carbide paper to #2,000, and ultrasonically cleaned. The working electrode is the specimen of four dental casting alloys, the reference electrode is a saturated calmel electrode(SCE) and the ounter electrode is made of platinum plate. In the artificial saliva solution, the potential scanning was carried out starting from-700mV(SCE) TO +1,000mV(SCE) and the scan rate was 75mV/min. Each polarization curve of alloy was recorded automatically on a logrithmic graphic paper by XY recorder. From the polarization curves of each galvanic couple, corrosion potential and corrosion rates, that is, corrosion density were compared and order of corrosion tendency was determined. From the experiments, the following results were obtained : 1. In the case of immersing titanium, gold alloy, silver-palladium alloy, and nickel-chromium alloysolely in the artificial saliva solution(group 1, 2, 3, and 4), the total amount of metal elements released was that group 4 was greater about 2, 3 times than group 3, and about 7.8 times than group 2. In the case of group 1, the amount of titanium released was not found after 8 week(p<0.001). 2. In the case of galvanic couples of titanium in contact with alloy(group 5, 6), the total amount of metal elements released of group 5 and 6 was less than that of group 7, 8, 9, and 10(p<0.05). 3. In the case of galvanic couples of titanium in contact with silver-palladium alloy(group 7, 8), the total amount of metal elements released of group 7 was greater about twice than that of group 5, and that of group 8 was about 14 times than that of group 6(p<0.05). 4. In the case of galvanic couples of titanium in contact with nickel-chromium alloy(group 9, 10), the total amount of metal elements released of group 9 and 10 was greater about 1.8-3.2 times than that of group 7 and 8, and was greater about 4.3~25 times than that of group 5 and 6(p<0.05). 5. In the effect of galvanic corrosion according to the difference of the area ratio of cathode and anode, the total amount of metal elements released was that group 5 was greater about 4 times than group 6, group 8 was greater about twice than group 7, and group 10 was greater about 1.5 times than group 9(p<0.05). 6. In the effect of galvanic corrosion according to the elasped time during 21 week in the interval of each 7 week, the amount of metal elements released was decreased markedly in the case of galvanic couples of the titanium in contact with gold alloy and silver-palladium alloy but the total amount of nickel and beryllium released was not decreased markedly in the case of galvanic couples of the titanium in contact with nickel-chromium alloy(p<0.05). 7. In the case of galvanic couples of titanium in contact with gold alloy, galvanic current was lower than any other galvanic couple. 8. In the case of galvanic couples of titanium in contact with nickel-chromium alloy, galvanic current was highest among other galvanic couples.

  • PDF

The Adjunctive Role of Resectional Surgery for the Treatment of Multidrug-Resistant Pulmonary Tuberculosis (다제내성 폐결핵의 치료에서 폐절제술의 보조적인 역할)

  • Koh, Won-Jung;Lee, Jae-Ho;Yoo, Chul-Gyu;Kim, Young-Whan;Chung, Hee-Soon;Sung, Sook-Whan;Im, Jung-Gi;Kim, Joo-Hyun;Shim, Young-Soo;Han, Sung-Koo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.975-991
    • /
    • 1997
  • Background : Many patients with isoniazid and rifampin-resistant pulmonary tuberculosis have organisms that are also resistant to other first-line drugs. Despite of aggressive retreatment chemotherapy, the results are often unsuccessful, with a failure rate approaching 40%. Recently, there has been a revival of resectional surgery for the treatment of multidrug-resistant pulmonary tuberculosis. Methods : A retrospective analyses of the case records and radiographic findings were done. Between January 1991 and December 1995, 14 human immunodeficiency virus (HIV)-seronegative patients with multidrug-resistant pulmonary tuberculosis were selected for resection to supplement chemotherapy. All patients had organisms resistant to many of the first-line drugs, including both isoniazid and rifampin. Results : Despite of aggressive therapy for median duration of 9.5 months, 12 of the 14 patients (86%) were still sputum smear and/or culture positive at the time of surgery. The disease was generally extensive. Although main lesions of the disease including thick-walled cavities were localized in one lung, lesser amounts of contralateral disease were demonstrated in 10 of 14 (71%). Types of surgery performed were pneumonectomy including extrapleural pneumonectomy in six patients, lobectomy or lobectomy plus in six patients, and segmentectomy in two patients. The resected lung appeared to have poor function ; preoperative perfusion lung scan showed only 4.8% of the total perfusion to the resected portion of the lung. There were no operative deaths. Two patients had major postoperative complications including empyema with bronchopleural fistula and prolonged air leak, respectively. Of the 14 patients, 13 (93%) remained sputum-culture-negative for M. tuberculosis for a median duration of 23 months and one remained continuously sputum smear and culture positive for M. tuberculosis. Conclusion : On the basis of comparison with historical controls, adjunctive resectional surgery appears to play a significant beneficial role in the management of patients with multidrug-resistant pulmonary tuberculosis if the disease is localized and there are adequate reserve in pulmonary function.

  • PDF

The Usefulness Evaluation of Radiation Shielding Devices in PET Scan Procedures (PET 검사 프러시저별 방사선 차폐기구의 유용성 평가)

  • Kim, Yeong-Seon;Seo, Myeong-Deok;Lee, Wan-Kyu;Jeong, Yo-Cheon;Kim, Sang-Wook;Seo, Il-Teak;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.65-76
    • /
    • 2010
  • Purpose: he use of PET scanners and the number of patient in Korea have been increased for recent several years dramatically. For this reason, technologists have more possibilities to be exposed to the radiation. The hospitals using PET scanners should make an effort to reduce the radiation exposure dose. The purpose of this study was to evaluate the radiation exposure does when using radiation shielding devices. The evaluation was performed through questionnaire survey and experiment. Materials and Methods: First, the technologists who had experience working in PET center in 2008-2009 were surveyed with questionnaire and TLD Figures, personal opinion of utilization of radiation shielding devices are analyzed. Second, we measured the shielding rate of shielding devices which have been using in PET study procedures. We divided the procedures into four steps; distribution, moving, injection of $^{18}F$-FDG and patient setup. Results: First, the results of this survey, using of L-block+Syringe shield, L-block, Syringe shield, No shield during the injection, were each 58.5%, 20%, 9%, 12.3%. The TLD values according to utilization of radiation shield, using both L-block+Syringe Shield and L-block showed the lower TLD values, and Syringe shield only or No shield showed the higher TLD values. Second, the results of experiments according to PET study procedures measured the shielding rates as follows. The shielding rates during the distribution using L-block, L-block+Apron shield were measured 97.4%, 97.7%. The shielding rates during the $^{18}F$-FDG delivery to the injection room using mobile Syringe shield, Syringe holder, Syringe shield carrier were each 81.7%, 98.9%, 99.7%. The shielding rates during the injection using Syringe shield, L-block, L-block+Syringe shield were measured each 51.9%, 98.3%, 98.7%. The shielding rates of Apron were measured in each 30, 60, 90, 120, 150 cm distance. The measurement were each 16.9%, 14.2%, 16.6%, 17.1%, 18.1%, 18.6%. Conclusion: The most effective method for radiation shielding is to using L-block during the $^{18}F$-FDG distribution and Syringe shield carrier during in moving $^{18}F$-FDG. For the $^{18}F$-FDG injection, L-block+Syringe shield have to be used. The shielding effect of Apron has shown average 16.4%. According to the survey of questionnaire, the operators recognized well risk of the radiation exposure but, tended ignore in working. The radiation dose according to recognition of radiation exposure risk was not relevant. but radiation dose according to utilization of radiation shield lower the more use it. The main reason of no use of shielding devices is cumbersome, 55% of the respondents answered. I'm sure, by use of radiation shield in all PET procedure, radiation exposure will be reduced considerably.

  • PDF

Clinical observation for the Geriatric C.V.A. (노인(老人) 뇌졸중(腦卒中)에 대(對)한 임상적(臨床的) 고찰(考察))

  • Seo, Un-Kyo;Jeong, Ji-Cheon;Lee, Won-Chul
    • The Journal of Internal Korean Medicine
    • /
    • v.14 no.2
    • /
    • pp.50-70
    • /
    • 1993
  • Clinical observation was done on 92 cases of Occlusive CVD, Cerebral hemorrhage (Subarachnoid hemorrhage) which were confirmed by Brain CT scan and observed for over 4 weeks, among the 121 cases which were more than 65 years of age. they admitted to the Dept. of Internal Medicine, Oriental Medical Hospital in Dong Guk Univ. from July 1992 to June 1993. The result were as follows; 1. In this study, Occlusive CVD was 74 cases, Cerebral hemorrhage (Subarachnoid hemorrhage was 2 cases) was 18 cases. 2. The ratio of male to female was 1.09:1. The age distribution showed the large number in the 65-69 year group(52.2%), 7th decade was 44.5% over 8th decade was 3.3% in ratio. 3. The site of Occlusive CVD was most common at MCA. the site of Cb-hemorrhage was most common at Basal ganglia. 4. The most common preceding disease was hypertension(47.8%) and the next were diabetes mellitus(14.1%), heart desease(14.1%). 5. Recurrence rate was 33.7% and 2nd attack was 20.7%, 3rd attack was 8.7%, 4th attack was 4.3% 6. Predisposing factors in Occlusive CVD were initiated usually during resting and sleeping, and that in Cb-hemorrhage were represented chiefly exercising(66.6%). 7. The smoker was 52.2%, the drinker was 32.6% in whole group. the drinker was 61.1% by the Cb-hemorrhage. 8. The ratio of the season distribution was as follow, fall 35.8%, winter 29.3%, spring 19.6%, summer 15.3%, that of the month distribution was november 15.2%. 9. Duration from on set in Occlusive CVD, 60.8% was within 5 days, that in Cb-hemorrhage, 77.8% was within 5 days. 10. Level of consciousness on attack was clear 42.2%, lethargy and mental change(dull, stupid etc.) 41.3%. The common symptoms were motor disturbance(90.2%), verbal disturbance(65.2%), headache(43.5%). 11. The physical theraphy of Occlusive CVD has been performed 75.7% in whole group and the average beginning time was 6.4 days, and that of Cb-hemorrhage has been performed 61.1% in whole group and the average beginning time was 13 days. 12. Duration of hospitalization was noted 11-20 days was 31.5%, over 21 days was 46.8%, and the average admission was 22.7 day(Occlusive CVD), 32days (Cb-hemorrhage). 13. The main complication were observed in the studies; urinary tract infection and pneumonia were noted in 6.5%, bed sore in 5.4%. 14. The ratio of systolic blood pressures in admission and discharge decreased from 58.7% to 28.3% in over 160 mmHg, that of diastolic blood pressures in admission and discharge decreased from 72.8% to 51.1% in over 90 mmHg. In 31(33.7%) of the 92 cases it showed the glucose levels of more than normal. 15. The patients have done family history of hypertension and C.V.A were 32.6% of all 16. Occlusive CVD In 83.8% and Cb-hernorrhage in 72.2% were improved 17. The herb medications were various Sunghyanggeonggisan, Sopungtang, CHunmagudeungeum were used most frequently and Gamidaebotang, Boyangwhanotang, Gagamyunjotang, Mangeumtang etc. were used as discharge.

  • PDF

Pulmonary Thromboendarterectomy for Pulmonary Hypertension Caused by Chronic Pulmonary Thromboembolism (만성폐색전중으로 인한 폐동맥고혈압 환자에서 시행한 폐동맥내막절제술)

  • Song Seung-Hwan;Jun Tae-Gook;Lee Young-Tak;Sung Ki-Ick;Yang Ji-Hyuk;Choi Jin-Ho;Kim Jin-Sun;Kim Ho-Joong;Park Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.626-632
    • /
    • 2006
  • Background: Pulmonary hypertension caused by chronic pulmonary embolism is underrecognized and carries a poor prognosis. Medical therapy is generally unsatisfactory and palliative. With the improvement of operative technique and postoperative management, pulmonary endarterectomy has been the treatment of choice for this condition. Material and Method: Between January 2001 and December 2005, eleven patients were received pulmonary endarterectomy. All patients had chronic dyspnea and exercise intolerance. Diagnosis was made with cardiac echocardiography, lung perfusion scan and computed tomography. Before the operation, Greenfield vena cava filter were placed in all patient except one. Deep hypothermic circulatory arrest was used for the distal-most portion of the endarterectomy procedure. More than moderate degree of tricuspid reguirgitation was repaired during operation. Result: There was no early and late death. Right ventricular systolic pressure was reduced significantly after operation from $91{\pm}21$ mmHg to $40{\pm}17$ mmHg on echocardiography (p=0.001). NYHA class and tricuspid reguirgitaion were improved postoperatively. Although mild reperfusion injury in three case and postoperative delirium in one case were observed, all of them recovered without complication. Conclusion: Pulmonary thromboendarterctomy offers to patient an acceptable morbidity rate and anticipation of clinical improvement. This method is safe and effective operation for pulmonary hypertension caused by chronic pulmonary thromboembolism.

Studies on the Anodic Oxidation Behavior of Methanol and L-Ascorbic Acid by Using Glassy Carbon Electrodes Modified with Inorganic-Metal Polymeric Films (무기 금속 고분자 막을 도포시킨 유리질 탄소전극을 이용한 메탄올과 L-ascorbic acid의 양극 산화 거동에 관한 연구)

  • Yoo, Kwang-Sik;Woo, Sang-Beom
    • Analytical Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.347-352
    • /
    • 1998
  • A study was carried out on the elelctrochemical characteristics of chemically modified electrodes (CMEs) by cyclic voltammetry. Fabrication of CMEs was made by coating with mixed valence (mv) inorganic-metal polymeric films on the glassy carbon electrode surface by potential cycling. Anodic oxidation behavior of methanol and L-ascorbic acid was studied by using CMEs working electrode. Deposition of films such as mv ruthenium oxo/ruthenium cyanide film (mv Ru-O/CN-Ru), mv ruthenium oxo/ferrocyanide film (mv Ru-O/$Fe(CN)_6$), and mv ruthenium oxo/ruthenium cyanide/Rhodium film (mv Ru-O/CN-Ru/Rh) was obtained to coat by scan rate of 50 mV/sec within the specified potential range (-0.5V ~ +1.2V). Film thickness was controlled by the repeat of the potential cycling. Anodic oxidation behavior of methanol was as follow. Calibration graph by using mv Ru-O/CN-Ru film showed linearly from 10 mM to 80 mM MeOH with slope factor of $-7.552{\mu}A/cm^2$. Although slope factor by using mv Ru-O/$Fe(CN)_6$ film was $-5.13{\mu}A/cm^2$, yet linear range of calibration graph could be extended from 10 mM to 100 mM MeOH. Anodic oxidation behavior of L-ascorbic acid was studied by mv Ru-O/CN-Ru film on the glassy carbon electrode and the glassy carbon electrode with Rh film, Glassy carbon electrode modified with Ru polymeric film was showed better sensitivity than the Rh-glassy carbon modified electrode (mv Ru-O/CN-Ru/Rh). Calibration graph was linear from 0.1 mM to 5 mM L-ascorbic acid by using glassy carbon electrode modified with Ru polymeric film. Solpe factor and relative coefficient are $-84.78{\mu}A/mM$ and 0.998, respectively.

  • PDF