• Title/Summary/Keyword: scan rate

Search Result 724, Processing Time 0.029 seconds

A study of the variations by motion of the Lower body Using 3D Body Surface Scan Data of a man in his early twenties (3차원 스캐너를 이용한 20대 남성의 하반신 신축량 분석)

  • Sohn, Boo-Hyun;Hong, Kyung-Hi
    • Korean Journal of Human Ecology
    • /
    • v.18 no.3
    • /
    • pp.729-740
    • /
    • 2009
  • This study is to research on the rate of expansion or contraction according to movement of the lower body of the man their twenties using Rapid Form software. And aim of this study is to get information of ease allowance in developing slacks pattern using 3D body surface scan data through comparison with existing slacks patterns. Considering on the contraction and expansion according to movement, it need to set the more ease allowance in hip circumference than waist circumference, and the more ease allowance in back hip width than front hip width in slacks. In crotch length, the length of front crotch is revealed contraction but the length of back crotch is revealed expansion. It is desirable lowering front waist line and raising back waist line to possess ease allowance in back crotch area. The length of side seam is revealed a little expansion but the length of inseam is showed a great expansion. To develop slacks pattern of scientific approach using 3D body surface scan data, it need to analysis the rate of expansion and contraction of the lower body based on the movement, shear deformation, slip in fabrics and skin, or in fabrics and fabrics, and slip down from waist line.

Gradient Waveform Synthesizer in Magnetic Resonance Imaging System using Digital Signal Processors (DSP를 이용한 자기공명영상시스템의 경사자계 파형 발생기)

  • Go, Gwang-Hyeok;Gwon, Ui-Seok;Kim, Chi-Yeong;Kim, Hyu-Jeong;Kim, Sang-Muk;An, Chang-Beom
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.1
    • /
    • pp.48-53
    • /
    • 2000
  • In this paper, we develop a TMS320C31 (60MHz) digital signal processor (DSP) board to synthesize gradient waveforms for Spiral Scan Imaging (SSI), which is one of the ultra fast magnetic resonance imaging (MRI) methods widely used. In SSI, accurate gradient waveforms are very essential to high quality magnetic resonance images. For this purpose, sampling rate for synthesizing the gradient waveforms is set twice as high as the data sampling rate. With the developed DSP boards accurate gradient waveforms are obtained. Ultra fast spiral scan imaging with the developed with the developed DSP board is currently under development.

  • PDF

Rebar Spacing Fixing Technology using Laser Scanning and HoloLens

  • Lee, Yeongjoo;Kim, Jeongseop;Lee, Jin Gang;Kim, Minkoo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.25 no.2
    • /
    • pp.69-80
    • /
    • 2024
  • Currently rebar spacing inspection is carried out by human inspectors who heavily rely on their individual experience, lacking a guarantee of objectivity and accuracy in the inspection process. In addition, if incorrectly placed rebars are identified, the inspector need to correct them. Recently, laser scanning and AR technologies have been widely used because of their merits of measurement accuracy and visualization. This study proposes a technology for rebar spacing inspection and fixing by combining laser scanning and AR technology. First, scan data acquisition of rebar layers is performed and the raw scan data is processed. Second, AR-based visualization and fixing are performed by comparing the design model with the model generated from the scan data. To verify the developed technique, performance comparison test is conducted by comparing with existing drawing-based method in terms of inspection time, error detection rate, cognitive load, and situational awareness ability. It is found from the result of the experiment that the AR-based rebar inspection and fixing technology is faster than the drawing-based method, but there was no significant difference between the two groups in error identification rate, cognitive load, and situational awareness ability. Based on the experimental results, the proposed AR-based rebar spacing inspection and fixing technology is expected to be highly useful throughout the construction industry.

Comparison of Diagnostic Value between the Absolute and Relative Uptake Rate on $^{99m}Tc-DMSA$ Renal Scan of Children with Febrile Urinary Tract Infection (발열성 요로감염 환아의 $^{99m}Tc-DMSA$ 신주사에서 절대적 신섭취율과 상대적 신섭취율의 진단적 가치에 대한 비교연구)

  • Kim Hee-Yeon;Bae Sang-Young;Whang Su-Ja;Park Eun-Ae;Kim Ho-Sung;Seo Jung-Wan;Lee Sung-Joo
    • Childhood Kidney Diseases
    • /
    • v.1 no.1
    • /
    • pp.24-30
    • /
    • 1997
  • Purpose: To evaluate the diagnositc value of the absolute and relative renal uptake rates on $^{99m}Tc-DMSA$ renal scan of children with febrile UTI. Method: The absolute and relative renal uptake rates of $^{99m}Tc-DMSA$ were checked in 68 children with febrile urinary tract infection (35 with unilateral focal defect; 13 with bilateral focal defect; and 20 with diffuse bilateral defect) and 49 children with afebrile UTI and normal $^{99m}Tc-DMSA$ renal scan as control. Results: The renal absolute uptake rate in the control group were $21.8{\pm}3.9%(right),\;22.2{\pm}3.9%(left),\;and\;44.2{\pm}7.8%(total)$. The absolute uptake rate gradually increased until the age 12 months and then was stationary. In febrile UTI with unilateral focal defect on the $^{99m}Tc-DMSA$ renal scan, both relative and absolute uptake rates were similarly diagnostic ($41.2{\pm}9.7%,\;16.5{\pm}5.4%$ vs $50.0{\pm}2.6%,\;22.0{\pm}3.9%$, p<0.01). In acute pyelonephritis with bilateral focal defect on the $^{99m}Tc-DMSA$ renal scan, the absolute uptake rate was significantly more diagnostic than the relative uptake rate[$17.3{\pm}5.3%$ (right), $17.4{\pm}5.3%\;(left),\;vs\;21.8{\pm}3.9%,\;(right)\;22.2{\pm}3.9%$, (left)% p<0.01]. In febrile UTI with bilateral diffuse defects on the $^{99m}Tc-DMSA$ renal scan, the absolute uptake rate was significantly diagnostic than the relative uptake rate [$18.1{\pm}3.9%\;(right),\;18.4{\pm}3.8%\;(left),\;vs\;21.8{\pm}3.9%,\;(right)\;22.2{\pm}3.9%$(left), p<0.01]. Conclusion: In the $^{99m}Tc-DMSA$ renal scan, the absolute uptake rate was more useful than the relative uptake rate to evaluate bilateral acute pyelonephritis.

  • PDF

A Study on Clinical Diagnosis of Temporomandibular Joint Disorders Using Bone Scan (골스캔을 이용한 측두하악관절장애의 임상진단에 관한 연구)

  • Bong-Jik Seo;Myung-Yun Ko
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.1
    • /
    • pp.103-113
    • /
    • 1996
  • The author examined the clinical signs and symptoms , routine radiographs, laboratory test and bone scan in 73 subjects with TMJ disorders and studied the responses of clinical test on patients, the distribution of signs and symptoms of joints, the simple uptake rate(SUR) of affected joints , the SUR of subclassified groups of TMJ disorders, active joints of subclassified groups of TMJ disorders and the SUR of joints with noises. The obtained results were as follows : 1. The percentage of joint pain on palpation, joint noises joint pain on function, mandibular dysfunction and active finding of bone scan in aptients with TMJ disorders were higher 2. The SUR was higher in joints affected by joint pain on function, joint pain on palpation, mandibular dysfunction and creptius. 3. The SUR of osteoarthrosis was the lowest. 4. The percentage of active joints were the highest in joints with discdisplacement without reduction, and followed by osteoarthritis, and disc displacement with reduction. 5. The SUR of TMJ showing joint noises only was lower.

  • PDF

A Design and Performance Analysis of the Fast Scan Digital-IF FFT Receiver for Spectrum Monitoring (스펙트럼 감시를 위한 고속 탐색 디지털-IF FFT 수신기 설계 및 분석)

  • Choi, Jun-Ho;Nah, Sun-Phil;Park, Cheol-Sun;Yang, Jong-Won;Park, Young-Mi
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.116-122
    • /
    • 2006
  • A fast scan digital-IF FFT receiver at the radio communication band is presented for spectrum monitoring applications. It is composed of three parts: RF front-end, fast LO board, and signal processing board. It has about 19GHz/s scan rate, multi frequency resolution from 10kHz to 2.5kHz, and high sensitivity of below -99dBm. The design and performance analysis of the digital-IF FFT receiver are presented.

Investigation on Grain Image Visulalization and Color Sorting Technique (색채선별기 곡물 이미지 가시화 및 선별기법에 관한 연구)

  • Lee, Choon-Young;Yan, Lei;Lee, Sang-Ryong;Par, Cheol-Woo
    • Journal of the Korean Society of Visualization
    • /
    • v.6 no.2
    • /
    • pp.20-27
    • /
    • 2008
  • The color sorting technique utilizing the image processing method is very applicable tool to analyze motion of a free-falling object in many agricultural and industrial research fields. In the present study, we have developed an image processing system and algorithm to sort good quality rice grains effectively from the bad ones. The system employs a high speed rate line-scan CCD camera with 2K-pixels and worked with a high speed DSP and FPGA in-line. It can accumulate acquired line-scan image data and visualize each grain image clearly. As a result, we can easily calculate the number of pixels occupied by grain(=grain size), gray level and its correct position by visualizing grain images rapidly.

Syndrome Check aided Fast-SSCANL Decoding Algorithm for Polar Codes

  • Choangyang Liu;Wenjie Dai;Rui Guo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.18 no.5
    • /
    • pp.1412-1430
    • /
    • 2024
  • The soft cancellation list (SCANL) decoding algorithm for polar codes runs L soft cancellation (SCAN) decoders with different decoding factor graphs. Although it can achieve better decoding performance than SCAN algorithm, it has high latency. In this paper, a fast simplified SCANL (Fast-SSCANL) algorithm that runs L independent Fast-SSCAN decoders is proposed. In Fast-SSCANL decoder, special nodes in each factor graph is identified, and corresponding low-latency decoding approaches for each special node is propose first. Then, syndrome check aided Fast-SSCANL (SC-Fast-SSCANL) algorithm is further put forward. The ordinary nodes satisfied the syndrome check will execute hard decision directly without traversing the factor graph, thereby reducing the decoding latency further. Simulation results show that Fast-SSCANL and SC-Fast-SSCANL algorithms can achieve the same BER performance as the SCANL algorithm with lower latency. Fast-SSCANL algorithm can reduce latency by more than 83% compared with SCANL, and SC-Fast-SSCANL algorithm can reduce more than 85% latency compared with SCANL regardless of code length and code rate.

Radiation Exposure Evaluation of Visual Organs using Bismuth Shielding Material on Head CT Scan (두부 CT촬영 시 비스무스 차폐체를 활용한 시각 기관의 방사선피폭평가)

  • Kang, Se-Sik;Kim, Changsoo;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.7
    • /
    • pp.451-456
    • /
    • 2016
  • To analyse the absorbed radiation dose of the visual organs (eyes, corneas, lenses) during a head CT scan, a with the purpose of radiation protection was designed. Afterwards, the reduction rate of radiation dose when using an eye-shielding was analyzed. The results showed that the higher the energy, the higher the absorbed dose of the eyes. Excluding the head, the organs with high dose were the eyes, corneas, and lenses, respectively. Furthermore, the dose reduction rate before and after shielding was between 38% and 55% for the eyes, and between 35% and 52% for the corneas. In the case of the lenses, when the front was shielded, the reduction rate was 51%, and when the front and the side were shielded simultaneously, the reduction rate was 67%.

A Study on the Reduction of Patient's Exposure Dose according to the Arrival Time of Contrast Media in Abdominal CT Scan using Bolus Tracking Technique (Bolus tracking 기법을 이용한 복부 CT 검사 시 조영제 도달시간에 따른 환자 피폭선량 감소에 관한 연구)

  • Lee, Seung yong;Han, Dong kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.93-100
    • /
    • 2021
  • The purpose of this study is to find out the factors that affect the patient's exposure dose during the abdominal CT scan using the bolus tracking technique, and reducing the radiation exposure to the patient during the abdominal CT scan using the bolus tracking technique by adjusting the delay time according to the corresponding factor. The experiment was divided into two parts, and the first experiment was conducted with 300 patients There were 188 males and 112 females, and their average age was 58±12.18(19~85). In the second experiment, 150 subjects (100 males and 50 females) who were undergoing their follow-up examination among the first experiment subjects, and the difference in dose before and after was compared by applying the delay time according to the influencing factor. As a result of the first experiment, there was a relationship between the arrival time of the contrast media and the heart rate, and it was found that the arrival time decreased as the heart rate increased for both men and women. As a result of the second experiment, the average dose of CTDIvol and DLP before/after applying the delay time according to the heart rate decreased 4.98 mGy and 5.33 mGy·cm in the male group, and 3.54 mGy and 3.88 mGy·cm in the female group. By applying proper delay time according to the patient's heart rate during abdominal CT scan with the bolus tracking technique, the radiation exposure dose of the patient can be reduced.