• 제목/요약/키워드: scan rate

검색결과 724건 처리시간 0.027초

인체의 3차원 스캔 데이터를 이용한 밀착 바디 슈트 개발 (2D Pattern Development of Tight-fitting Bodysuit from 3D Body Scan Data for Comfortable Pressure Sensation)

  • 정연희
    • 한국생활과학회지
    • /
    • 제15권3호
    • /
    • pp.481-490
    • /
    • 2006
  • Adjusting pressure level in the construction of athletes' tight-fitting garments by reducing the elastic knit pattern is a challenging subject, which influences the performance of the wearer directly. Therefore, in this study, relationship between the reduction rates of the basic pattern obtained from 3D human scan data and resultant clothing pressure was explored to improve the fit and pressure exerted by clothing. 3D scan data were obtained using Cyberware and they were transformed into a flat pattern using software based on Runge-Kutta method. Reduction rate was examined by subjective wear test as well as objective pressure measurement. As a result, difference in the length between the original 3D body scan data and the 2D tight-fitting pattern was 0.02$\sim$0.50cm (0.05$\sim$1.06%), which was within the range of tolerable limits in making clothes. Among the five garments, the 3T-pattern was superior in terms of subjective sensation and fit. The pressure of the 3T pattern was 2$\sim$4 gf/cm2 at five locations on the body, which is almost the same or a bit higher than that of Z-pattern. In the case of tight-fitting overall garment, the reduction rate of the pattern in the wale direction is more critical to the subjective sensation than the course direction. It is recommended that the reduction grading rules of course direction should be larger than that of Ziegert for a better fit of tight-fitting garments. In the case of wale direction, however, reduction grading rule should be kept the same as suggested earlier by Ziegert (1988).

  • PDF

Utility of Spinal Injury Diagnosis Using C-Spine Lateral X-Ray and Chest, Abdomen and Pelvis Computed Tomography in Major Trauma Patients with Impaired Consciousness

  • Jang, Yoon Soo;So, Byung Hak;Jeong, Won Jung;Cha, Kyung Man;Kim, Hyung Min
    • Journal of Trauma and Injury
    • /
    • 제31권3호
    • /
    • pp.151-158
    • /
    • 2018
  • Purpose: The regional emergency medical centers manage the patients with major blunt trauma according to the process appropriate to each hospital rather than standardized protocol of the major trauma centers. The primary purpose of this study is to evaluate the effectiveness and influence on prognosis of additional cervical-thoracic-lumbar-spine computed tomography (CTL-spine CT) scan in diagnosis of spinal injury from the victim of major blunt trauma with impaired consciousness. Methods: The study included patients visited the urban emergency medical center with major blunt trauma who were over 18 years of age from January 2013 to December 2016. Data were collected from retrospective review of medical records. Sensitivity, specificity, positive predictive value, and negative predictive value were measured for evaluation of the performance of diagnostic methods. Results: One hundred patients with Glasgow coma scale ${\leq}13$ underwent additional CTL-spine CT scan. Mechanism of injury was in the following order: driver, pedestrian traffic accident, fall and passenger accident. Thirty-one patients were diagnosed of spinal injury, six of them underwent surgical management. The sensitivity of chest, abdomen and pelvis CT (CAP CT) was 72%, specificity 97%, false positive rate 3%, false negative rate 28% and diagnostic accuracy 87%. Eleven patients were not diagnosed of spinal injury with CAP CT and C-spine lateral view, but all of them were diagnosed of stable fractures. Conclusions: C-spine CT scan be actively considered in the initial examination process. When CAP CT scan is performed in major blunt trauma patients with impaired consciousness, CTL-spine CT scan or simple spinal radiography has no significant effect on the prognosis of the patient and can be performed if necessary.

동전위 분극저항 측정에서의 불확도 (Uncertainty in Potentiodynamic Polarization Resistance Measurement)

  • 김종집
    • Corrosion Science and Technology
    • /
    • 제8권5호
    • /
    • pp.193-196
    • /
    • 2009
  • For the estimation of uncertainty in potentiodynamic polarization resistance measurement, the type A uncertainty was measured using type 316 stainless steel in an acidified NaCl solution. Sensitivity coefficients were determined for measurand such as scan rate of potential, temperature of solution, concentration of NaCl, concentration of HCl, surface roughness of specimen and flow rate of purging gas. Sensitivity coefficients were large for the measurand such as the scan rate of potential, temperature of solution and roughness of specimen. However, the sensitivity coefficients were not the major factors influencing the combined standard uncertainty of polarization resistance due to the low values of uncertainty in measurements of the measurands. A major influencing factor was the concentration of NaCl. The value of type A uncertainty was 1.1 times the value of type B uncertainty, and the combined standard uncertainty was 10.5 % of the average value of polarization resistance.

IN718 초내열 합금의 고속 적층 제조 속도 확보를 위한 최적 VED 활용 공정 변수 제어 방안 연구 (Study for the Process Parameter Control to Achieve High Build Rate of Laser Powder Bed Fused IN718 Super Alloy Using Optimal VED)

  • 김상욱;김규식;손용호;이기안
    • 한국분말재료학회지
    • /
    • 제29권5호
    • /
    • pp.390-398
    • /
    • 2022
  • Recently, considerable attention has been given to nickel-based superalloys used in additive manufacturing. However, additive manufacturing is limited by a slow build rate in obtaining optimal densities. In this study, optimal volumetric energy density (VED) was calculated using optimal process parameters of IN718 provided by additive manufacturing of laser powder-bed fusion. The laser power and scan speed were controlled using the same ratio to maintain the optimal VED and achieve a fast build rate. Cube samples were manufactured using seven process parameters, including an optimal process parameter. Analysis was conducted based on changes in density and melt-pool morphology. At a low laser power and scan speed, the energy applied to the powder bed was proportional to ${\frac{P}{\sqrt{V}}}$ and not ${\frac{P}{V}}$. At a high laser power and scan speed, a curved track was formed due to Plateau-Rayleigh instability. However, a wide melt-pool shape and continuous track were formed, which did not significantly affect the density. We were able to verify the validity of the VED formula and succeeded in achieving a 75% higher build rate than that of the optimal parameter, with a slight decrease in density and hardness.

Assessment of the increased calcification of the jaw bone with CT-Scan after dental implant placement

  • Yunus, Barunawaty
    • Imaging Science in Dentistry
    • /
    • 제41권2호
    • /
    • pp.59-62
    • /
    • 2011
  • Purpose : This study was performed to evaluate the changes of jaw bone density around the dental implant after placement using computed tomography scan (CT-Scan). Materials and Methods : This retrospective study consisted of 30 patients who had lost 1 posterior tooth in maxilla or mandible and installed dental implant. The patients took CT-Scan before and after implant placement. Hounsfield Unit (HU) was measured around the implants and evaluated the difference of HU before and after implant installation. Results : The mean HU of jaw bone was 542.436 HU and 764.9 HU before and after implant placement, respectively (p<0.05). The means HUs for male were 632.3 HU and 932.2 HU and those for female 478.2 HU and 645.5 HU before and after implant placement, respectively (p<0.05). Also, the jaw bone with lower density needed longer period for implant procedure and the increased change of HU of jaw bone was less in the cases which needed longer period for osseointegration. Conclusion : CT-Scan could be used to assess the change of bone density around dental implants. Bone density around dental implant was increased after placement. The increased rate of bone density could be determined by the quality of jaw bone before implant placement.

흉곽부위 골절에 대한 골스캔의 유용성 고찰 (Availability of Bone Scan in Chest Trauma Patients)

    • Journal of Chest Surgery
    • /
    • 제31권11호
    • /
    • pp.1085-1088
    • /
    • 1998
  • 연구배경 : 많은 외상 환자에서 흉곽골이 손상에 노출되지만 흉곽골 외상 환자에서 단순 흉부 사진으로 흉곽부위 손상정도를 최종진단 하기는 어려운 경우가 많다. 특별히 흉곽골의 경미한 손상의 경우는 골주사 검사를 사용하여 명확한 진단을 할 수 있겠는데 감수성은 매우 높은 결과를 나타내었다. 재료 및 방법 : 680명의 흉곽 외상환자 중 골스캔을 환자를 대상으로 조사하였다. 결과 : 680례에서 감수성은 97.4%이고 위음성은 2.6%였다. 감수성에 있어서 검사 실시 시기가 가장 중요한 요소로 생각되며 손상 부위별로 늑골이나 흉골 골절의 경우는 1주 이후, 늑연골 접합부골절의 경우와 상기 부위골절들이 동반된 경우는 3일 이후면 언제나 우수한 결과를 보였다. 결론 : 흉부외상환자에서 골절에 대한 정확한 진단을 위하여는 적절한 시기의 골스캔이 필요하다.

  • PDF

Visual Precise Measurement of Pile Rebound and Penetration Movement Using a High-Speed Line-Scan Camera

  • Lim, Mee-Seub;You, Bum-Jae;Oh, Sang-Rok;Han, Song-Soo;Lee, Sang-Hun
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제4권4호
    • /
    • pp.341-346
    • /
    • 2002
  • When a construction company builds a high structure. many piles should be driven into the ground by a hammer whose weight is 7,000 kg in order to make the ground under the structure safe and strong. So. it is essential to determine whether a pile is penetrated into the ground enough to support the weight of the structure since ground characteristics at different locations are different each other. This paper proposes a visual measurement system for pile rebound and penetration movement including vibration using a high-speed line-scan camera and a specially designed mark to recognize two-dimensional motion parameters of the mark using only a line-scan camera. A mark stacking white and black right-angled triangles is used for the measurement, and movement information for vertical distance, horizontal distance and rotational angle is determined simultaneously. Especially- by adopting a line-scan CCD camera whose line rate is 20 ㎑. the measurement performance of dynamic characteristics of the pile at impact instant is improved dramatically.

간경변증(肝硬變症)에 있어서 교질형방사성금(膠質形放射性金)($^{198}Au$)을 사용(使用)한 간(肝)스켄과 간기능(肝機能)과의 관계(關係)에 관(關)한 임상연구(臨床硏究) (A Clinical Study on Liver Scanning using Colloidal Radiogold and Liver Function in Cirrhosis of the Liver)

  • 고창순;이종헌;장고창;이영;민영일;홍창기
    • 대한핵의학회지
    • /
    • 제3권1호
    • /
    • pp.59-67
    • /
    • 1969
  • Correlation between the blood clearance half time and findings of liver scan using the colloidal radiogold in patients of liver cirrhosis is observed through the scoring system, in which the more changes in size, shape and density in the liver scan, the more points are given (table 1). Results: 1) Within the increase in severity of hepatocellular dysfunction in liver cirrhosis, the degree and frequency of following changes in liver scan (done with colloidal radiogold) were increased in order. a) generalized hepatomegaly b) enlargement of the left lobe & reduction of the right lobe c) relatively increased radiodensity in the left lobe and 4) visualization of spleen. 2) Frequency of the normal scan in liver cirrhosis was $12{\pm}3.56%$, frequency of normal value in blood clearance half time of the radiogold was $5.0{\pm}2.34%$ and frequency of normal scan & normal blood clearance rate in liver cirrhosis was $3.6{\pm}2.06%$.

  • PDF

소아 99mTc-DMSA 검사에서 신장 섭취율의 평가 (Evaluation of Renal Uptake Rate in 99mTc-DMSA Scan on Pediatrics)

  • 백승주;이효영;길상형;조경남
    • 한국방사선학회논문지
    • /
    • 제9권4호
    • /
    • pp.235-238
    • /
    • 2015
  • 소아 $^{99m}Tc-DMSA$ 검사에서 방광의 포함 여부에 따른 신장 섭취율의 차이를 비교 하였다. 팬텀실험과 임상실험으로 진행되었으며 3개의 컵으로 좌, 우측신장 그리고 방광에 위치시키고 좌, 우측 신장의 방사능은 일정한 양( 1.0 )으로 고정하였고 방광에 해당되는 컵에는 0, 0.5, 1, 2배 방사능의 차이를 두어 영상을 획득하였다. 임상환자는 $^{99m}Tc-DMSA$ (300uCi, 11MBq)을 주사하여 2시간 뒤 동일하게 영상 획득하여 각각 정량 분석하였다. 통계분석은 SPSS(ver 22.0) 으로 대응표본 T검증(paired T-test)을 사용하여 분석하였고 p<0.05는 통계적으로 유의하다고 판단하였다. 방광의 방사능을 제외한 양측 신장 섭취율은 $29.83{\pm}8.8%$(좌측), $24.29{\pm}6.66%$(우측)이었고, 방광을 포함했을 때 신장 섭취율은 $26.65{\pm}8.03%$(좌측), $21.78{\pm}6.24%$(우측)이었다. 신장 섭취율은 방광의 소변(방사능)이 증가할수록 양측 신장의 섭취율은 감소하였다. 이는 $^{99m}Tc-DMSA$ 신장스캔 시 좌, 우측 신장에서 방사능을 계수할 때 방광의 소변에 포함된 방사능의 계수가 포함되어 신장 섭취율 공식에서 총 계수가 포함되므로 실제 양측 신장 섭취율의 값이 감소되었다.

Electrochemical Properties of Polyaniline Electrodes Prepared by Chemical Synthesis and Electrodeposition: Revisited with High-Scan-Rate Behaviors

  • Nam, Ji Hyun;Woo, Cho Hyeon;Kim, Kwang Man;Ryu, Kwang Sun;Ko, Jang Myoun
    • Journal of Electrochemical Science and Technology
    • /
    • 제3권2호
    • /
    • pp.80-84
    • /
    • 2012
  • The polyaniline (PANI) electrodes are prepared by chemical synthesis and electrodeposition methods and their supercapacitive properties are characterized and compared by morphology observation, cyclic voltammetry as a function of scan rate, and impedance spectra analysis. In particular, the supercapacitive properties obtained in the range of higher potential scan rates (e.g., over $200mV\;s^{-1}$) are emphasized to be capable of utilizing adequately the high power capability of supercapacitor. As a result, the PANI electrode by the electrodeposition shows superior specific capacitance (max. $474F\;g^{-1}$ at $10mV\;s^{-1}$ and about $390F\;g^{-1}$ at $500mV\;s^{-1}$) than those by the chemical synthesis method. This is mainly due to highly porous structure obtained by the electrodeposition to yield higher specific surface area.