• Title/Summary/Keyword: scan rate

Search Result 732, Processing Time 0.025 seconds

Comparison of Activity Capacity Change and GFR Value Change According to Matrix Size during 99mTc-DTPA Renal Dynamic Scan (99mTc-DTPA 신장 동적 검사(Renal Dynamic Scan) 시 동위원소 용량 변화와 Matrix Size 변경에 따른 사구체 여과율(Glomerular Filtration Rate, GFR) 수치 변화 비교)

  • Kim, Hyeon;Do, Yong-Ho;Kim, Jae-Il;Choi, Hyeon-Jun;Woo, Jae-Ryong;Bak, Chan-Rok;Ha, Tae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.27-32
    • /
    • 2020
  • Purpose Glomerular Filtration Rate(GFR) is an important indicator for evaluating renal function and monitoring the progress of renal disease. Currently, the method of measuring GFR in clinical trials by using serum creatinine value and 99mTc-DTPA(diethylenetriamine pentaacetic acid) renal dynamic scan is still useful. After the Gates method of formula was announced, when 99mTc-DTPA Renal dynamic scan is taken, it is applied the GFR is measured using a gamma camera. The purpose of this paper is to measure the GFR by applying the Gates method of formula. It is according to effect activity and matrix size that is related in the GFR. Materials and Methods Data from 5 adult patients (patient age = 62 ± 5, 3 males, 2 females) who had been examined 99mTc-DTPA Renal dynamic scan were analyzed. A dynamic image was obtained for 21 minutes after instantaneous injection of 99mTc-DTPA 15 mCi into the patient's vein. To evaluate the glomerular filtration rate according to changes in activity and matrix size, total counts were measured after setting regions of interest in both kidneys and tissues in 2-3 minutes. The distance from detector to the table was maintained at 30cm, and the capacity of the pre-syringe (PR) was set to 15, 20, 25, 30 mCi, and each the capacity of post-syringe (PO) was 1, 5, 10, 15 mCi is set to evaluate the activity change. And then, each matrix size was changed to 32 × 32, 64 × 64, 128 × 128, 256 × 256, 512 × 512, and 1024 × 1024 to compare and to evaluate the values. Results As the activity increased in matrix size, the difference in GFR gradually decreased from 52.95% at the maximum to 16.67% at the minimum. The GFR value according to the change of matrix size was similar to 2.4%, 0.2%, 0.2% of difference when changing from 128 to 256, 256 to 512, and 512 to 1024, but 54.3% of difference when changing from 32 to 64 and 39.43% of difference when changing from 64 to 128. Finally, based on the presently used protocol, 256 × 256, PR 15 mCi and PO 1 mCi, the GFR value was the largest difference with 82% in PR 15 mCi and PO 1 mCi. conditions, and at the least difference is 0.2% in the conditions of PR 30 mCi and PO 15 mCi. Conclusion Through this paper, it was confirmed that when measuring the GFR using the gate method in the 99mTc-DTPA renal dynamic scan. The GFR was affected by activity and matrix size changes. Therefore, it is considered that when taking the 99mTc-DTPA renal dynamic scan, is should be careful by applying appropriate parameters when calculating GFR in the every hospital.

$^{99m}Tc$ MDP-Bone Scintigraphy for Preoperative and Follow up Assessment in Primary Breast Cancer (원발성 유방암에서 질병병기 분류 및 추적검사 $^{99m}Tc-MDP$ 골 신티그램의 의의)

  • Yi, Gang-Wook;Bang, Yung-Jue;Chung, June-Key;Lee, Myung-Chul;Cho, Bo-Youn;Kim, Noe-Kyoung;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.22 no.1
    • /
    • pp.59-64
    • /
    • 1988
  • Because carcinoma of breast is known to readily metastasize to the bone, early detection of metastasis spread is very important. Two hundred thirty four consecutive patients who had $^{99m}Tc-MDP$ bone scans prior to treatment and during the follow up period were studied retrospectively to determine the contribution of the scans to staging, treatment and follow up examination between Jan. 1980 and Apr. 1987 in Seoul National University Hospital. 1) Positive bone scan rates in initial clinical stage I, II, III and IV were 0%, 4%, 14% and 53%, respectively. 2) The higher clinical stage is, the more cumulative risk of conversion to positive bone scan is during the same follow up period. 3) Conversion rate to positive bone scan in patients with lymph node metastasis is higher (50%) than those without metastasis (18%) (P < 0.001). We concluded that the bone scan in primary breast cancer was very useful to evaluate initial clinical stage and to perform the follow up examination.

  • PDF

The Prognostic Factors Influencing on the Therapeutic Effect of Percutaneous Vertebroplasty in Treating Osteoporotic Vertebral Compression Fractures

  • Ryu, Kyeong-Sik;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.1
    • /
    • pp.16-23
    • /
    • 2009
  • Objective : This retrospective study of 215 patients with 383 symptomatic osteoporotic vertebral compression fractures (VCFs) treated by percutaneous vertebroplasty (PVP), was performed to evaluate the clinical outcomes, and to analyze the various clinical factors affecting these results. Methods : The authors assessed the clinical outcome under the criteria such as the pain improvement, activity, requirement of analgesics, and the patient's satisfaction, and determined the relation to various peri- and intra-operative factors, and postoperative imaging findings. Results : The outcome was determined as 84.2% in relief of pain, 72.0% in change in activity, 65.7% in analgesics use, and 84.7% of satisfaction rate. More severe focal back pain, high uptake bone scan, and the lower mean T-score were related to the better pain relief following PVP. The longer the duration between fracture and PVP, the less severe focal back pain, low uptake bone scan, and leakage of PMMA into the paravertebral space were related to the less improvement in activity. Female and low uptake bone scan showed a correlation with more analgesic use. The longer the duration between fracture and PVP, low uptake bone scan, and the higher the mean T-score were correlated with the less the patients satisfaction. Conclusion : Our study suggests that PVP may be more effective in the acute phase of VCFs, more severe focal pain, and far advanced osteoporosis on BMD. Leakage of PMMA into the paravertebral spcae also could be affecting the surgical results.

A Bluetooth Scatternet Formation Algorithm based on Hardware Implementation (하드웨어 구현을 기반으로 한 블루투스 스캐터넷 형성 알고리즘)

  • 이한욱;고상근
    • Journal of KIISE:Information Networking
    • /
    • v.31 no.3
    • /
    • pp.314-326
    • /
    • 2004
  • Bluetooth has been reputed as a wireless ad-hoc networking technology supplying scalable and extensible networks between digital devices. For that kind of networks, scatternet is a most essential part in bluetooth. But past researches on bluetooth scatternet has proposed only possibilities of scatternet algorithm based on simulation results. And many of the researches failed in guaranteeing extensibility and flexibility and had many difficulties in real hardware implementation. In this paper, we proposed node ring scatternet(NRS) algorithm guaranteeing extensible and flexible networks. NRS algorithm is designed for hardware implementation using real commercial bluetooth module. That algorithm is divided into initial formation and reformation. For initial formation, we proposed limited SEEK/SCAN algorithm. For reformation, we proposed DIAC algorithm and Reserved Recovery Node algorithm. And we proposed SFMP(Scatternet Formation & Management Protocol) in protocol stack for real implementation. NRS algorithm is operated in SFMP. Finally, we performed real hardware experiments and evaluated the proposed algorithm. In that experiments, we succeeded in forming scatternet up to 20 nodes. In comparison with other similar algorithm, proposed algorithm have the improvement in scatternet formation delay and success rate.

Dynamically Collimated CT Scan and Image Reconstruction of Convex Region-of-Interest (동적 시준을 이용한 CT 촬영과 볼록한 관심영역의 영상재구성)

  • Jin, Seung Oh;Kwon, Oh-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.151-159
    • /
    • 2014
  • Computed tomography (CT) is one of the most widely used medical imaging modality. However, substantial x-ray dose exposed to the human subject during the CT scan is a great concern. Region-of-interest (ROI) CT is considered to be a possible solution for its potential to reduce the x-ray dose to the human subject. In most of ROI-CT scans, the ROI is set to a circular shape whose diameter is often considerably smaller than the full field-of-view (FOV). However, an arbitrarily shaped ROI is very desirable to reduce the x-ray dose more than the circularly shaped ROI can do. We propose a new method to make a non-circular convex-shaped ROI along with the image reconstruction method. To make a ROI with an arbitrary convex shape, dynamic collimations are necessary to minimize the x-ray dose at each angle of view. In addition to the dynamic collimation, we get the ROI projection data with slightly lower sampling rate in the view direction to further reduce the x-ray dose. We reconstruct images from the ROI projection data in the compressed sensing (CS) framework assisted by the exterior projection data acquired from the pilot scan to set the ROI. To validate the proposed method, we used the experimental micro-CT projection data after truncating them to simulate the dynamic collimation. The reconstructed ROI images showed little errors as compared to the images reconstructed from the full-FOV scan data as well as little artifacts inside the ROI. We expect the proposed method can significantly reduce the x-ray dose in CT scans if the dynamic collimation is realized in real CT machines.

Low velocity Impact Characteristics of Non-flamable Composite Laminates (난연성 복합적층재의 저속충격특성)

  • 김재훈;김후식;조정미;박병준
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.10a
    • /
    • pp.179-182
    • /
    • 2001
  • Impacter tester was build of to evaluate the characterization of non-flamable Glass/phenol laminate plates under the low velocity impact. The damage of composite laminates are matrix cracking, delamination, and fiber breakage for impact energy. In this study, this is to find impact properties of Glass/phenol in used in a forehead part of lighting subway. To determine impact damage characteristics which is made in a laminate, use the UT C-scan after- macrography. And then evaluated the reduction of strength in a rate of impact energy with CAI(Compression After Impact) test

  • PDF

Scan Manifestations and Blood Clearance Rates in Typhoid Liver (티프스 간(肝)의 주사(走査)소견과 간혈류 동태)

  • Bahk, Yong-Whee;Ahn, Jae-Sung;Kim, Soon-Hi
    • The Korean Journal of Nuclear Medicine
    • /
    • v.4 no.2
    • /
    • pp.67-71
    • /
    • 1970
  • Fourteen patients with typhoid fever were studied by scanning and clearance-rate measurements of subcritical dose colloidal radiogold($^{198}Au$). Mild to moderate enlargement of the liver and spleen was noted in 78.6 and 64.3 per cent of patients, respectively; and splenic and spinal bone-marrow uptake was seen in 78.6 and 57.1 per cent of cases, respectively. Typically, these scan changes occurred concomitantly (57.1%) and are considered to represent increased phagocytic activity of the RE cells which is characteristic of typhoid fever. The half clearance-time was significantly shortened during the first 10-day period of the illness indicating an increas in the hepatic blood in the early phase of typhoid infection. Hepatomegaly, splenomegaly and extrahepatic uptakes along with an accelerated (or later a normal) clearance time are characteristic of typhoid fever.

  • PDF

Salivary Scan Findings and Excretion Rate in $Sj\"{o}gren$ Syndrome ($Sj\"{o}gren$ Syndrome에서 타액선 스캔 소견과 타액 제거율에 관한 연구)

  • Lee, Myung-Hae;Chung, June-Key;Lee, Myung-Chul;Cho, Bo-Youn;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.22 no.1
    • /
    • pp.33-37
    • /
    • 1988
  • Salivary scan and stimulated salivary clearance of $^{99m}Tc-pertechnetate$ was performed in 11 pateients with $Sj\"{o}gren$ syndrome (group I), 4 patients with rheumatoid arthritis (group II), 8 patients with non-connective tissue diseases (group III) and 9 normal controls. Stimulated salivary clearances of pertechnetate of normal controls, group II and group III were in normal range (over 16.5 ml/min) and that of patients with $Sj\"{o}gren's$ syndrome was significantly reduced (11.1 ml/min).

  • PDF

Container Identifier Recognition System for GATE automation (GATE 자동화를 위한 컨테이너 식별자 인식 시스템)

  • 유영달;하성욱;강대성
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1998.10a
    • /
    • pp.137-141
    • /
    • 1998
  • Todays the efficient management of container has not been realized in container terminal, because of the excessive quantity of container transported and manual system. For the efficient and automated management of container in terminal, the automated container identifier recognition system in terminal is a significant problem. However, the identifier recognition rate is decreased owing to the difficulty of image preprocessing caused the refraction of container surface, the change of weather and the damaged identifier characters. Therefore, this paper proposes more accurate system for container identifier recognition as suggestion of Line-Scan Proper Region Detect for stronger preprocessing against external noisy element and Moment Back-Propagation Neural Network to recognize identifier.

  • PDF

Effect of Process Parameters on Surface Roughness and Porosity of Direct Laser Melted Bead (DLM 공정시 공정변수에 따른 내부공극률과 표면조도 변화)

  • Kim, T.H.;Jang, J.H.;Jeon, C.H.;Moon, Y.H.
    • Transactions of Materials Processing
    • /
    • v.20 no.8
    • /
    • pp.575-580
    • /
    • 2011
  • Direct laser melting(DLM) is promising as a joining method for producing parts for automobiles, aerospace, marine and medical applications. An advantageous characteristic of DLM is that it affects the parent metal very little. The mechanical properties of parts made by DLM are strongly affected by the porosity and surface roughness of the laser melted beads. This is a systematic study of the effects of the porosity and surface roughness of laser melted beads using various processing parameters, such as laser power, scan rate and overlapping ratio of the fill spacing. The specimens were fabricated with 316L and 304L austenitic stainless steel powder. Dense parts with low porosity were obtained at low laser scan speed, as it increased the aspect ratio of the parental material and the depth of penetration. The variations of surface roughness were examined at various processing parameters such as overlapping ratio and laser power.