• Title/Summary/Keyword: scan design

Search Result 509, Processing Time 0.025 seconds

Percutaneous Polymethylmethacrylate Vertebroplasty in the Treatment of Osteoporotic Thoracic and Lumbar Vertebral Body Compression Fractures : Outcome of 159 Patients (159명의 골다공증성 흉추 및 요추부 골다공증성 추체 압박골절 환자에 대한 경피적 척추성형술 후 치료결과)

  • Lee, Jae-Un;Ryu, Kyeong-Sik;Park, Chun-Kun;Choi, Yeong-Kun;Park, Chun-Kun;Ji, Chul;Cho, Kyung-Suk;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.173-179
    • /
    • 2001
  • Purpose : To assess therapeutic effects of percutaneous polymethylmethacrylate(PMMA) vertebroplasty on the pain caused by osteoporotic thoracic and lumbar vertebral body compression fractures in a large scale of a prospective clinical design, and to determine clinical factors influencing its therapeutic effects. Methods : A prospective clinical study was carried out in 349 vertebral levels of 159 patients between April 1998 and July 1999. The compression fractures were confirmed with bone scan and spine CT, and bone marrow density was measured. Visual analogue scale(VAS) score was used for pre- and post-operative assessments of the pain. All 159 patients were assessed immediately after surgery, and 140 patients of them were followed-up for about 6 months in average. Results : Partial and complete pain relief was sustained immediately after operation in 73%, through follow-up period in 88% of the patients. Pain relief was not proportional to the amount of PMMA or the rate of increase in the height of the compressed vertebral body. It appears that 3 to 6cc of PMMA was proper enough to sustain pain relief. Better clinical improvement was achieved in the patients treated within 6 months after occurrence of vertebral body fracture. The most frequent surgical complication was epidural leakage of PMMA, and the most serious complication was extravertebral leakage into the paravertebral muscles, which appeared to exert the worst influence on the outcome. However, surgery was not required in these patients. Conclusion : Therapeutic effects of PMMA percutaneous vertebroplasty on osteoporotic vertebral body compression fractures were confirmed in a relatively large scale of prospective clinical study. It appears that good outcome can be achieved in patients treated within 6 months after fracture, treated each level with 3 to 6cc of PMMA in amount. without serious complications.

  • PDF

A Study on the Development Methodology of Intelligent Medical Devices Utilizing KANO-QFD Model (지능형 메디컬 기기 개발을 위한 KANO-QFD 모델 제안: AI 기반 탈모관리 기기 중심으로)

  • Kim, Yechan;Choi, Kwangeun;Chung, Doohee
    • Journal of Intelligence and Information Systems
    • /
    • v.28 no.1
    • /
    • pp.217-242
    • /
    • 2022
  • With the launch of Artificial Intelligence(AI)-based intelligent products on the market, innovative changes are taking place not only in business but also in consumers' daily lives. Intelligent products have the potential to realize technology differentiation and increase market competitiveness through advanced functions of artificial intelligence. However, there is no new product development methodology that can sufficiently reflect the characteristics of artificial intelligence for the purpose of developing intelligent products with high market acceptance. This study proposes a KANO-QFD integrated model as a methodology for intelligent product development. As a specific example of the empirical analysis, the types of consumer requirements for hair loss prediction and treatment device were classified, and the relative importance and priority of engineering characteristics were derived to suggest the direction of intelligent medical product development. As a result of a survey of 130 consumers, accurate prediction of future hair loss progress, future hair loss and improved future after treatment realized and viewed on a smartphone, sophisticated design, and treatment using laser and LED combined light energy were realized as attractive quality factors among the KANO categories. As a result of the analysis based on House of Quality of QFD, learning data for hair loss diagnosis and prediction, micro camera resolution for scalp scan, hair loss type classification model, customized personal account management, and hair loss progress diagnosis model were derived. This study is significant in that it presented directions for the development of artificial intelligence-based intelligent medical product that were not previously preceded.

Elevator Algorithm Design Using Time Table Data (시간표 데이터를 이용한 엘리베이터 알고리즘 설계)

  • Park, Jun-hyuk;Kyoung, Min-jun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.122-124
    • /
    • 2022
  • Handling Passenger Traffic is the main challenge for designing an elevator group-control algorithm. Advanced control systems such as Hyundai's Destination Selection System(DSS) lets passengers select the destination by pressing on a selecting screen, and the systems have shown great efficiency. However, the algorithm cannot be applied to the general elevator control system due to the expensive cost of the technology. Often many elevator systems use Nearest Car(NC) algorithms based on the SCAN algorithm, which results in time efficiency problems. In this paper, we designed an elevator group-control algorithm for specific buildings that have approximate timetable data for most of the passengers in the building. In that way, it is possible to predict the destination and the location of passenger calls. The algorithm consists of two parts; the waiting function and the assignment function. They evaluate elevators' actions with respect to the calls and the overall situation. 10 different timetables are created in reference to a real timetable following midday traffic and interfloor traffic. The specific coefficients in the function are set by going through the genetic algorithm process that represents the best algorithm. As result, the average waiting time has shortened by a noticeable amount and the efficiency was close to the known DSS result. Finally, we analyzed the algorithm by evaluating the meaning of each coefficient result from the genetic algorithm.

  • PDF

Prediction accuracy of incisal points in determining occlusal plane of digital complete dentures

  • Kenta Kashiwazaki;Yuriko Komagamine;Sahaprom Namano;Ji-Man Park;Maiko Iwaki;Shunsuke Minakuchi;Manabu, Kanazawa
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.6
    • /
    • pp.281-289
    • /
    • 2023
  • PURPOSE. This study aimed to predict the positional coordinates of incisor points from the scan data of conventional complete dentures and verify their accuracy. MATERIALS AND METHODS. The standard triangulated language (STL) data of the scanned 100 pairs of complete upper and lower dentures were imported into the computer-aided design software from which the position coordinates of the points corresponding to each landmark of the jaw were obtained. The x, y, and z coordinates of the incisor point (XP, YP, and ZP) were obtained from the maxillary and mandibular landmark coordinates using regression or calculation formulas, and the accuracy was verified to determine the deviation between the measured and predicted coordinate values. YP was obtained in two ways using the hamularincisive-papilla plane (HIP) and facial measurements. Multiple regression analysis was used to predict ZP. The root mean squared error (RMSE) values were used to verify the accuracy of the XP and YP. The RMSE value was obtained after crossvalidation using the remaining 30 cases of denture STL data to verify the accuracy of ZP. RESULTS. The RMSE was 2.22 for predicting XP. When predicting YP, the RMSE of the method using the HIP plane and facial measurements was 3.18 and 0.73, respectively. Cross-validation revealed the RMSE to be 1.53. CONCLUSION. YP and ZP could be predicted from anatomical landmarks of the maxillary and mandibular edentulous jaw, suggesting that YP could be predicted with better accuracy with the addition of the position of the lower border of the upper lip.

Dosimetric Analysis of a Phase I Study of PSMA-Targeting Radiopharmaceutical Therapy With [177Lu]Ludotadipep in Patients With Metastatic Castration-Resistant Prostate Cancer

  • Seunggyun Ha;Joo Hyun O;Chansoo Park;Sun Ha Boo;Ie Ryung Yoo;Hyong Woo Moon;Dae Yoon Chi;Ji Youl Lee
    • Korean Journal of Radiology
    • /
    • v.25 no.2
    • /
    • pp.179-188
    • /
    • 2024
  • Objective: 177Lutetium [Lu] Ludotadipep is a novel prostate-specific membrane antigen targeting therapeutic agent with an albumin motif added to increase uptake in the tumors. We assessed the biodistribution and dosimetry of [177Lu]Ludotadipep in patients with metastatic castration-resistant prostate cancer (mCRPC). Materials and Methods: Data from 25 patients (median age, 73 years; range, 60-90) with mCRPC from a phase I study with activity escalation design of single administration of [177Lu]Ludotadipep (1.85, 2.78, 3.70, 4.63, and 5.55 GBq) were assessed. Activity in the salivary glands, lungs, liver, kidneys, and spleen was estimated from whole-body scan and abdominal SPECT/CT images acquired at 2, 24, 48, 72, and 168 h after administration of [177Lu]Ludotadipep. Red marrow activity was calculated from blood samples obtained at 3, 10, 30, 60, and 180 min, and at 24, 48, and 72 h after administration. Organand tumor-based absorbed dose calculations were performed using IDAC-Dose 2.1. Results: Absorbed dose coefficient (mean ± standard deviation) of normal organs was 1.17 ± 0.81 Gy/GBq for salivary glands, 0.05 ± 0.02 Gy/GBq for lungs, 0.14 ± 0.06 Gy/GBq for liver, 0.77 ± 0.28 Gy/GBq for kidneys, 0.12 ± 0.06 Gy/GBq for spleen, and 0.07 ± 0.02 Gy/GBq for red marrow. The absorbed dose coefficient of the tumors was 10.43 ± 7.77 Gy/GBq. Conclusion: [177Lu]Ludotadipep is expected to be safe at the dose of 3.7 GBq times 6 cycles planned for a phase II clinical trial with kidneys and bone marrow being the critical organs, and shows a high tumor absorbed dose.

THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION AND DEFORMATION IN MANDIBLE ACCORDING TO THE POSITION OF PONTIC IN TWO IMPLANTS SUPPORTED THREE-UNIT FIXED PARTIAL DENTURE (두 개의 임플란트를 이용한 3본 고정성 국소의치에서 가공치 위치에 따른 하악골에서의 응력 분포 및 변형에 관한 삼차원 유한요소법적 연구)

  • Kim, Dong-Su;Kim, Il-Kyu;Jang, Keum-Soo;Park, Tae-Hwan;Kim, Kyu-Nam;Son, Choong-Yul
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.2
    • /
    • pp.166-179
    • /
    • 2008
  • Excessive concentration of stress which is occurred in occlusion around the implant in case of the implant supported fixed partial denture has been known to be the main cause of the crestal bone destruction. Therefore, it is essential to evaluate the stress analysis on supporting tissue to get higher success rates of implant. The purpose of this study was to evaluate the effects of stress distribution and deformation in 3 different types of three-unit fixed partial denture sup-ported by two implants, using a three dimensional finite element analysis in a three dimensional model of a whole mandible. A mechanical model of an edentulous mandible was generated from 3D scan, assuming two implants were placed in the left premolars area. According to the position of pontic, the experiments groups were divided into three types. Type I had a pontic in the middle position between two implants, type II in the anterior posi-tion, and type III in the posterior position. A 100-N axial load was applied to sites such as the central fossa of anterior and posterior implant abutment, central fossa of pontic, the connector of pontic or the connector between two implants, the mandibular boundary conditions were modeled considering the real geometry of its four-masticatory muscular supporting system. The results obtained from this study were as follows; 1. The mandible deformed in a way that the condyles converged medially in all types under muscular actions. In comparison with types, the deformations in the type II and type III were greater by 2-2.5 times than in the type I regardless of the loading location. 2. The values of von Mises stresses in cortical and cancellous bone were relatively stable in all types, but slightly increased as the loading position was changed more posteriorly. 3. In comparison with type I, the values of von Mises stress in the implant increased by 73% in Type II and by 77% in Type III when the load was applied anterior and posterior respectively, but when the load was applied to the middle, the values were similar in all types. 4. When the load was applied to the centric fossa of pontic, the values of von Mises stress were nearly $30{\sim}35%$ higher in the type III than type I or II in the cortical and cancellous bone. Also, in the implant, the values of von Mises stress of the type II or III were $160{\sim}170%$ higher than in the type I. 5. When the load was applied to the centric fossa of implant abutment, the values of von Mises stress in the cortical and cancellous bone were relatively $20{\sim}25%$ higher in the type III than in the other types, but in the implant they were 40-45% higher in the type I or II than in the type III. According to the results of this study, musculature modeling is important to the finite element analysis for stress distribution and deformation as the muscular action causes stress concentration. And the type I model is the most stable from a view of biomechanics. Type II is also a clinically accept-able design when the implant is stiff sufficiently and mandibular deformation is considered. Considering the high values of von Mises stress in the cortical bone, type III is not thought as an useful design.

A Study on Promotion and Improvement of YouTube Music Contents Through the User Evaluation of Card Live ('명함라이브' 사용자 평가를 통한 유튜브 음악 콘텐츠 홍보 및 개선방안 연구)

  • You, Jae-Sun
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.4
    • /
    • pp.105-120
    • /
    • 2020
  • This study explores the process of the actual content production and distribution, by creating a YouTube channel to promote the popular music contents produced by the researcher, which thus reflects the reality where the production of video contents rapidly increases. A YouTube channel titled "Alida Music", of which the focus was to promote indie musicians, was created on February 2019. The contents of 10 indie musicians were produced in one-take live format. The information of the indie musicians was displayed in the form of a screen business card, with their e-mail address and SNS account at the top. Therefore, this promotional design was named "Card Live". Promotional video contents marked with the QR code in the lower right on the screen were produced, along with the promotional phrase "Communicate directly with the artist through the QR code", which allows viewers to watch other contents of the indie musician when they scan the QR code. This research conducted a study on how to improve and promote "Card Live" contents of "Alida Music", which were produced through this process. A group interview targeting five indie musicians, among whom one participant deemed significant was selected to conduct a one-to-one in-depth interview. As a result of the study, the following three conclusions were drawn. First, YouTube was found to be the medium with the greatest influence and highest efficiency at the lowest cost. Second, the evaluation of the participants on "Card Live" were divided into the three categories: need for one-take live, the design elements of "Card Live", and scanning issues of the QR code. Third, there is a need for promotional methods that can effectively utilize the media aspects of YouTube: the channel management issues such as raising public awareness as well as the number of subscribers of "Alida Music" should be resolved and measures to effectively use various media including other SNS should be developed. In terms of its content, it is imperative to recruit diverse performers to make various contents, as well as to come up with ways to link "Card Live" contents with offline. Based on these results, "Card Live" contents should be further revised and complemented in order to provide interesting contents to consumers, which will further develop "Alida Music" as a platform where various musicians and companies meet, thereby inducing contracts with popular music agencies and generating advertising revenues. However, since this study was carried out only with the limited number of participants, future studies should include more participants to bring forth a variety of promotional plans and improvement measures. Also, in the era of consuming contents through smart devices, the fact that some features of "Card Live" were available only on PC, did not fully reflect the characteristics of the times. In the future research, various contents that smartphone users can access and view freely without PC should be produced.

Interstitial Vaginal Needle Implantation in Gynecological Tumors : Design and Construction of Applicator (부인과암에서 조직내 삽입 방사선치료 - Applicator의 고안 및 제작-)

  • Kang, Seung-Hee;Chun, Mi-Son;Kang, Hae-Jin;Jung, Chil;Son, Jeong-Hyae
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.167-175
    • /
    • 1998
  • Purpose : It is not a simple task to achieve the ideal isodose curve with a standard vaginal applicator or sing1e plane needle impant in the paravaginal tissue when primary or recurrent gynecological neoplasms(cervical cancers, vaginal cancers and vulvar cancers) are treated as a boost following external beam radiotherapy. The authors introduce the development and construction of a simple, inexpensive, customized applicator for volume implant to maximize the radiation dose to the tumor while minimizing the dose to the rectum and the bladder. Materials and Methods : Nine patients underwent Ir-192 transperineal interstitial implantation for either recurrent(5 cases) or primary(3 cases) cervical cancers or primary vaginal cancer(1 case) between August 1994 and February 1998 at Ajou university hospital. First 3 cases were performed with a sing1e plane implant guided by digital palpation. Because of inadequate isodose coverage in the tumor volume in first 3 cases, we designed and constructed interstitial vaginal applicator for volume implant to improve tumor dose distribution and homogeneity while sparing the surrounding normal tissue. Our applicators consist of vaginal obturator and perineal template that made of the clear acrylamide and dental mold material$(Provil^{(R)})$. The applicators were customized individually according to the tumor size and its location Both HDR and LDR irradiation were given with these applicators accomodating 6 Fr needles(Microselectron Nucletron). The pretreatment planning prior to actual implant was performed whenever possible. Results : Needles can be inserted easily and evenly into the tumor volume through the holes of templates, requiring less efforts and time for the implant procedure. Our applicators made of materials available from commercial vendors. These have an advantage that require easy procedure, and spend relatively short time to construct. Also it was possible to fabricate applicators to individualize according to the tumor size and its location and to achieve the ideal isodose coverage. We found an accurate needle arrangement and ideal dose distribution through the CT scan that was obtained in 3 cases after needle implant. Three patients with primary cervical and vaginal cancers were controlled locally at final follow up. But all recurrent cases failed to do so. Conclusion : The authors introduce inexpensive, simple interstitial vaginal templates which were self-designed and constructed using materials available from commercial vendors such as acrylanide and dental mold material $(Provil^{(R)})$.

  • PDF

A Study on Damage factor Analysis of Slope Anchor based on 3D Numerical Model Combining UAS Image and Terrestrial LiDAR (UAS 영상 및 지상 LiDAR 조합한 3D 수치모형 기반 비탈면 앵커의 손상인자 분석에 관한 연구)

  • Lee, Chul-Hee;Lee, Jong-Hyun;Kim, Dal-Joo;Kang, Joon-Oh;Kwon, Young-Hun
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.7
    • /
    • pp.5-24
    • /
    • 2022
  • The current performance evaluation of slope anchors qualitatively determines the physical bonding between the anchor head and ground as well as cracks or breakage of the anchor head. However, such performance evaluation does not measure these primary factors quantitatively. Therefore, the time-dependent management of the anchors is almost impossible. This study is an evaluation of the 3D numerical model by SfM which combines UAS images with terrestrial LiDAR to collect numerical data on the damage factors. It also utilizes the data for the quantitative maintenance of the anchor system once it is installed on slopes. The UAS 3D model, which often shows relatively low precision in the z-coordinate for vertical objects such as slopes, is combined with terrestrial LiDAR scan data to improve the accuracy of the z-coordinate measurement. After validating the system, a field test is conducted with ten anchors installed on a slope with arbitrarily damaged heads. The damages (such as cracks, breakages, and rotational displacements) are detected and numerically evaluated through the orthogonal projection of the measurement system. The results show that the introduced system at the resolution of 8K can detect cracks less than 0.3 mm in any aperture with an error range of 0.05 mm. Also, the system can successfully detect the volume of the damaged part, showing that the maximum damage area of the anchor head was within 3% of the original design guideline. Originally, the ground adhesion to the anchor head, where the z-coordinate is highly relevant, was almost impossible to measure with the UAS 3D numerical model alone because of its blind spots. However, by applying the combined system, elevation differences between the anchor bottom and the irregular ground surface was identified so that the average value at 20 various locations was calculated for the ground adhesion. Additionally, rotation angle and displacement of the anchor head less than 1" were detected. From the observations, the validity of the 3D numerical model can obtain quantitative data on anchor damage. Such data collection can potentially create a database that could be used as a fundamental resource for quantitative anchor damage evaluation in the future.