• 제목/요약/키워드: scaled down model

검색결과 127건 처리시간 0.024초

CANDU-6 감속재 탱크 모형의 유동장 전산해석 및 예비측정 (Computational Flow Analysis and Preliminary Measurement for the CANDU-6 Moderator Tank Model)

  • 차재은;최화림;이보욱;김형태
    • 한국가시화정보학회지
    • /
    • 제10권3호
    • /
    • pp.30-36
    • /
    • 2012
  • We are planning to construct a scaled-down moderator facility to simulate the CANDU-6 moderator circulation phenomena during steady state operating and accident conditions. In the present work a preliminary experiment using a 1/40 scaled-down moderator tank has been performed to investigate the anticipated problems of the flow visualization and measurement in the planning scaled-down moderator facility. We shortly describe CFD analysis result for the 1/40 scaled-down test model and the flow measurement techniques used for this test facility under isothermal flow conditions. The Particle Image Velocimetry (PIV) method is used to visualize and measure the velocity field of water in a transparent Plexiglas tank. Planar Laser Induced Fluorescence (PLIF) technique is used to evaluate the feasibility of temperature field measurement in the range of $20-40^{\circ}C$ of water temperature using an one-color method.

Design of A scale-down experimental model for SFR reactor vault cooling system performance analyses

  • Kim, Koung Moon;Hwang, Ji-Hwan;Wongwises, Somchai;Jerng, Dong-Wook;Ahn, Ho Seon
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1611-1625
    • /
    • 2020
  • We propose a scaled-down experimental model of vertical air-natural convection channels by applying the modified Ishii-Kataoka scaling method with the assistance of numerical analyses to the Reactor Vault Cooling System (RVCS) of the Proto-type Gen-IV Sodium-cooled fast reactor (PGSFR) being developed in Korea. Two major non-dimensional numbers (modified Richardson and Friction number) from the momentum equation and Stanton number from the energy balance equation were identified to design the scaled-down experimental model to assimilate thermal-hydraulic behaviors of the natural convective air-cooling channel of RVCS. The ratios of the design parameters in the PGSFR RVCS between the prototype and the scaled-down model were determined by setting Richardson and Stanton number to be unity. The friction number which cannot be determined by the Ishii-Kataoka method was estimated by numerical analyses using the MARS-KS system code. The numerical analyses showed that the friction number with the form loss coefficient of 2.0 in the scale-down model would result in an acceptable prediction of the thermal-hydraulic behavior in RVCS. We also performed experimental benchmarking using the scaled-down model with the MARS-KS simulations to verify the appropriateness of the scale-down model, which demonstrated that the temperature rises and the average air flow velocity measured in the scale-down model.

PSALI 연구를 위한 실물대 실험 장치와 축소 모형간의 유의성 검증 (Verification of Significancebetween Experiment Devices and Scaled-down Model for the Study of PSALI)

  • 이진숙;김소연;하태현;정용규
    • 조명전기설비학회논문지
    • /
    • 제25권12호
    • /
    • pp.11-20
    • /
    • 2011
  • PSALI is referred to the supplementary lighting for the interior lighting under the daily lighting situation, and pursuant to the pertinent regulations in energy savings design standard and others in recent architecture works, the importance thereof has been increasing gradually coupled with the energy performance index (EPI), energy savings plan and the like as well as expansion of submittal and implementation policies. However, this type of PSALI studies indeed have a number of limitations since it has surrounding environmental conditions in direction, season, region, climate, time, opening rate, window area ratio, actual index, reflection rate of finishing materials and others in the architecture work as well as frequent changes in interior lighting environment for variables in daily light volume flowing into the interior, and others. Therefore, this study has analyzed existing advance research cases to produce the actual-sized model and scaled-down model, and installed the artificial lighting of LED light source possible to reproduce with same capability on both models. As a result of comparison and analysis of the artificial lighting with the key light, it has certain level of error rate from the scaled down lighting device in certain rate and actual model butit was noticeably significant within specific scope.

NREL 풍력터빈 블레이드 20% 축소모델 풍동시험 결과 (Wind tunnel test for the 20% scaled down NREL wind turbine blade)

  • 조태환;김철완;김양원;노주현
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.33.2-33.2
    • /
    • 2011
  • The 'NREL Phase VI' model with a 10.06m diameter was tested in the NASA Ames tunnel to make a reference data of the computational models. The test was conducted at the one rotational speed, blade tip speed 38m/s and the Reynolds number of the sectional airfoils in that test was around 1E6. The 1/5 scale down model of the 'NREL Phase VI' model was used in this paper to study the power characteristics in low Reynolds number region, 0.1E6 ~ 0.4E6 which is achievable range for the conventional wind tunnel facilities. The torque generated by the blade was directly measured by using the torque sensor installed in the rotating axis for a given wind speed and rotational speed. The power characteristics below the stall condition, lambda > 4, was presented in this paper. The power coefficient is very low in the condition below the Re. 0.2E6 and rapidly increases as the Re. increases. And it still increases but the variation is not so big in the condition above the Re. 0.3E6. This results shows that to study the performance of the wind turbine blade by using the scaled down model, the Re. should be larger than the 0.3E6.

  • PDF

Structural response relationship between scaled and prototype concrete load bearing systems using similarity requirements

  • Altunisik, Ahmet C.;Kalkan, Ebru;Basaga, Hasan B.
    • Computers and Concrete
    • /
    • 제21권4호
    • /
    • pp.385-397
    • /
    • 2018
  • This study is focused on the investigation for similitude the requirements between prototype and scaled models to determine the structural behavior of concrete load bearing systems. The scaling concept has been utilized in many engineering branches, has been assisted to engineers and scientists for obtain the behavior of the prototype by using scaled model. The scaling can be done for two purposes, either scaling up or scaling down depending upon the application. Because, scaled down models are the experimentation on scaled models is cheaper than huge structures. These models also provide facilities for experimental work. Similarity relationships between systems are created either by field equations of the system or by dimensional analysis. Within this study, similarity relationships were obtained by both methods. The similarity relations obtained are applied to different load bearing systems and it is determined that the similarity relation is a general expression. In this study, as an example, column, frame, cantilever beam and simple beam are chosen and 1/2, 1/5 and 1/10 scales are applied. The results are compared with the analytical results which are obtained by creating of the finite element models with SAP2000 software of different scaled load bearing systems. The analysis results of all systems are examined and it is determined that the scale factors are constant depending on the scale types for different load bearing systems.

정적 연소실에서의 열 손실 해석 모델 (Analysis of Heat Loss Effect of Combustion in Closed Vessel)

  • 이대훈;권세진
    • 한국연소학회지
    • /
    • 제6권1호
    • /
    • pp.14-19
    • /
    • 2001
  • Interests and importance of down-scale combustor is increasing with the emerging need for miniaturized power source which is now a bottleneck of micro system development. But in down scaled combustor increased heat loss compared to thermal energy generation inhibits the usability and application of the device, so as a preliminary work of down scaled combustor fabrication. Modeling tool for the device should be established, in this study modeling approach of closed vessel combustion phenomena that can express heat loss effect and resulting quenching is proposed and the result is compared with experiment data. From this model heat loss effect following combustor scale down can be further understood, and further more design parameter and analysis tool can be obtained.

  • PDF

형상 축소된 연소기의 열손실 및 소염해석 모델 (Thermodynamic Modeling of Heat Loss and Quenching in a Down Scaled Combustor)

  • 이대훈;권세진
    • 대한기계학회논문집B
    • /
    • 제26권7호
    • /
    • pp.919-926
    • /
    • 2002
  • Down scaled combustor undergoes increased heat loss that results in incomplete combustion or quenching of the flame as a consequence. Therefore, effect of enhanced heat loss should be understood to design a MEMS scale combustion devices. Existing combustion models are inadequate for micro combustors because they were developed for analysis of regular scale combustor where heat loss can be ignored during the flame propagation. In this research a combustion model is proposed in order to estimate the heat loss and predict quenching limit of flame in a down scaled combustor. Heat loss in the burned region is expressed in a convective form as a product of wall surface area, heat transfer coefficient and temperature difference. Comparison to the measurements showed satisfactory agreement of the pressure and temperature drop. Quenching is accounted for by introducing a correlation of quenching parameter and heat loss. The present model predicted burnt fraction of gases with reasonable accuracy and proved to be applicable in thermal design of a micro combustor.

축소모형실험 및 PFC2D해석에 따른 발파해체 거동분석 (A Study of Blasting Demolition by Scaled Model Test and PEC2D Analysis)

  • 채희문;전석원
    • 터널과지하공간
    • /
    • 제14권1호
    • /
    • pp.54-68
    • /
    • 2004
  • 본 연구에서는 경제성장기에 고층 구조물 시공에서 널리 사용된 철근콘크리트(RC, Reinforced Concrete) 구조물을 대상으로 발파해체 축소모형실험을 수행하고 전산실험결과와 이를 비교하였다. 발파해체 공법으로는 파괴거동을 비교적 쉽게 확인할 수 있는 점진붕괴공법을 적용하였으며, 축소모형실험은Hobbs(1969)에 의한 축소율의 개념에 따라 차원해석을 실시하여 축소된 강도특성을 계산하였다. 사용재료로는 석고, 모래, 물의 혼합액을 콘크리트 대용으로 사용하였다. 모래와 석고의 중량 비를 다양하게 변화시키면서 이에 따른 강도의 변화를 측정하고 최적의 강도 값을 갖는 배합 비를 결정하였다. 또한 연성을 가지고 있으며 축소강도로 비교할 때 철근과 유사한 특성을 지니는 땜용 납선을 철근대용 재료로 사용하였다. 수치해석 프로그램으로는 요소의 파괴거동을 육안으로 확인할 수 있는 개별 요소법(DEM Distinct Element Method)에 의해 수행되는 상용코드인 PFC2D(Particle Flow Code 2-Dimension)을 사용하였다. 모형의 제작은 실내에서 미리 양생된 부재들을 현장으로 옮겨 연결부만을 타설하여 일체화시키는 방법으로 이루어졌다. 먼저 3차원 무근 콘크리트 라멘 구조의 모형을 설계하고 그 축소 모형을 발파해체하여 그 거동을 촬영하였다. 이를 수치적인 해석과 비교하는 과정을 통해 2차원 해석이라는 한계성은 존재하지만 대체로 유사한 형태의 거동을 보임을 알 수 있었다. 사전해석의 경험과 RC 보의 실내 굴곡 실험결과를 근거로 하여 RC 구조모형의 발파해체 사전해석을 실시하였다. 시차는 200㎳로 하여 점진적으로 붕괴되도록 설계하였다. 모형실험과는 달리 2차원 해석이라는 한계에도 불구하고 900㎳까지 매우 유사한 거동을 보이며 붕괴되었다.

KUH 주로터 축소 블레이드 설계 (Design of KUH Main Rotor Small-scaled Blade)

  • 김도형;김승호;한정호
    • 항공우주기술
    • /
    • 제8권1호
    • /
    • pp.32-41
    • /
    • 2009
  • 본 연구에서는 한국형기동헬기(KUH) 주로터 블레이드의 축소 설계를 수행하였다. 축소 모델은 공력하중, 익단 와류 및 소음원 측정 시험을 위해 설계되었다. 실제 로터와 동일한 공력 하중을 모사하기 위하여 마하스케일링 기법이 적용되었다. 마하스케일 모델은 블레이드의 익단 마하수가 동일하며, 정규화된 진동수 또한 동일하다. 즉, 마하스케일된 모델은 공력하중 및 구조동역학적 과점에서 상사된 모델이다. 공기역학적 축소과정은 외형 치수의 축소와 회전수의 증가를 통해 완료된다. 구조동역학적 측면에서는 블레이드 단면 설계를 통해 생성된 강성 및 관성 분포가 실제 로터의 회전고유진동수 분포를 나타내는지 확인하는 과정을 통해 완료된다. 본 연구에서는 국내에서 수급 가능한 복합재 프리프레그를 이용한 블레이드 단면 설계를 수행하고, 설계된 모델의 동역학적 특성을 고찰하였다.

  • PDF

MODAL CHARACTERISTIC ANALYSIS OF THE APR1400 NUCLEAR REACTOR INTERNALS FOR SEISMIC ANALYSIS

  • Park, Jong-Beom;Choi, Youngin;Lee, Sang-Jeong;Park, No-Cheol;Park, Kyoung-Su;Park, Young-Pil;Park, Chan-Il
    • Nuclear Engineering and Technology
    • /
    • 제46권5호
    • /
    • pp.689-698
    • /
    • 2014
  • Reactor internals are sensitive to dynamic loads such as earthquakes and flow induced vibration. Thus, it is essential to identify the dynamic characteristics to evaluate the seismic integrity of the structures. However, a full-sized system is too large to perform modal experiments, making it difficult to extract data on its modal characteristics. In this research, we constructed a finite element model of the APR1400 reactor internals to identify their modal characteristics. The commercial reactor was selected to reflect the actual boundary conditions. Our FE model was constructed based on scale-similarity analysis and fluid-structure interaction investigations using a fabricated scaled-down model.