• Title/Summary/Keyword: saving rate

Search Result 724, Processing Time 0.025 seconds

A Study on the Performance Characteristics of an Absorption Chiller for Variable Cooling Water Flow Rate at Partial Load Conditions (흡수식 냉온수기의 부분부하에 따른 냉각수 변유량시 성능특성에 관한 연구)

  • 박찬우;조현철;강용태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.26-33
    • /
    • 2004
  • In general, an absorption chiller or heat pump is operated under the constant cooling water flow rate condition even though the system works with a partial load. The objective of this paper is to study the effect of the cooling water flow rates and the temperature of cooling water on the system performance to find the energy saving methode for the partial load operation of the double effect $H_2O$/LiBr absorption chiller. It is found that the performance of the system is sensitive to the temperature of cooling water than the cooling water flow rate, so the decrease of the performance due to reducing the cooling water flow rate can be overcome with the reduction of the cooling water temperature by 1$^{\circ}C$. The flow rate of the cooling water flow rate ranges from 50% to 100% of the flow rate at normal conditions with a partial load. It is also found that the operation cost of the cooling water pump and the cooling tower can be reduced by 23%.

A Study on the Control of Apartment House Design Factors considering Energy, Environment and Economical Efficiency (에너지, 환경 및 경제성을 통합 고려한 공동주택 설계요소 제어에 관한 연구)

  • Choi, Doo-Sung;Do, Jin-Seok
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.29-38
    • /
    • 2012
  • The current building energy efficiency rating certification regulation on apartment houses evaluates only the saving rate of energy consumed during operation, i.e. use, of a building, but doesn't consider the energy consumptions and environmental load($CO_2$) emissions occurring during the whole lifetime of a building. So this study calculated the energy consumptions and environmental load emissions occurring during the whole lifetime of a building, selected reference schemes and alternative items by design variables to present a design draft considering energy efficiency and environmental performance, and evaluated the total cost by combining and calculating its direct cost(material and heating cost) and indirect cost(environmental cost), for an existing apartment house as an evaluation object. As a result of analysis, the change of heating cost by alternative items of design variables showed a 4~8% change rate compared to the reference scheme, and the material cost of design variable 7 showed a maximum 4.4 times change rate in the alternative plan 6 compared to the reference scheme. The environmental cost showed a similar change rate to the material cost change rate in general, but showed a similar environmental cost change rate to the heating cost change rate in case of design variables 4-1, 4-2, 7.

A Research on the $CO_2$ Peak Point Control According to Ventilation Rate During Sleeping (취침 시 환기횟수에 따른 $CO_2$ 피크치 제어에 관한 연구)

  • Kim, Se-Hwan;Kim, Dong-Gyu;Park, Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.49-54
    • /
    • 2009
  • Ventilation requirement of apartment was mandated according to building equipment standards in 2006. When ventilation unit was considering for indoor air quality maintenance, we needed energy saving and efficiency ventilation control methods. This study carried out experiment of ventilation rate 0.7 adequacy. When we lived in apartment, we assumed that sleeping time was long stayed time in unconsciousness. Experiments carried out ventilation rate 0, 0.1, 0.4 and 0.7 in environment chamber from 22 o'clock to 06 o'clock, the concentration of $CO_2$, temperature and humidity rate measured. Analyzing the results, conclusions are as follows. 1) When we sleep in bedroom, ventilation rate 0.4 meet the requirements of domestic legal standards. Conform fan of similarity law, ventilation rate 0.4 reduced power cost about 80% than 0.7. 2) In generally sleeping time 8 hours, peak point control reduced running time of ventilation unit about 43% than normal control.

A Study on the Characteristics of Heat Source Temperature for Two-Well Geothermal System Using Numerical Simulation (수치 시뮬레이션을 이용한 복수정(Two-Well) 개방형 지열 시스템의 열원수 온도 변화 검토)

  • Cho, JeongHeum;Nam, YuJin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.4
    • /
    • pp.207-212
    • /
    • 2015
  • The use of groundwater and ground_heat is one of the ways to use natural and renewable energy, and it has been considered as a technology to reduce greenhouse gas emissions and increase energy-saving. There are a few researches on the optimum design for the open-loop geothermal system. In this study, to develop the optimal design method numerical simulation of the open-loop geothermal system with two-wells was performed by a groundwater and heat transfer model. In this paper, a study was performed to analyze the system performance according to well distance and pumping flow rate. In the result, average heat exchange rate and heat source temperature were calculated and it was found that they were dependent on the pumping rate.

Cooling Characteristics of Fruits and Vegetables for Pressure Cooling (차압통풍 예냉 청과물의 냉각특성)

  • 윤홍선;박경규
    • Food Science and Preservation
    • /
    • v.4 no.3
    • /
    • pp.237-243
    • /
    • 1997
  • Numerous variables affect product cooling rate of pressure cooling system for fruits and vegetables. These include carton vent area, initial and desired final product temperature, flow rate and temperature of the cooling air, product size, shape and thermal properties and product configuration(whether in bulk or packed in shipping cartons). This study was carried out to determine the influence of each of these variables as they affect cooling time. The opening ratio and number of the vent hole were recomended as 4∼10% and 2∼4ea., respectively, for a minimum alt flow resistance and for a uniform air flow pattern. In the cooling experiment for tomatoes and mandarins, optimum air flow rate was 0.04 m3/min.kg in terms of energy saving. The cooling air temperature should be about 2$^{\circ}C$ less than the desired final product temperature for reducing cooling time.

  • PDF

Control Characteristics with Flow Rate Control Methods in Central Heating System (중앙난방시스템의 유량제어방식에 따른 제어특성 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.7 no.1
    • /
    • pp.32-37
    • /
    • 2011
  • In this study, control characteristics and energy performance with flow rate control methods were reviewed with the simulation. The heating system is classified such as fan coil unit and HVAC system currently used in buildings with valve control and pump inverter control. The simulation analysis program is made by TRNSYS ver. 15 with the actual data. As a result of this study, the central heating system with pump inverter control decreases electricity energy and reduces gas consumption. Inverter control method shows better performance in comparison with valve control one for energy saving.

The experimental study of the performance characteristics of a tumbler type laundry dryer (통기드럼형 의류용 건조기의 성능특성에 관한 실험적 연구)

  • Jang, Yong-Soo;Lee, Sang-Won;Kim, Soo-Yeon;Jung, Pyung-Suk
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.187-192
    • /
    • 2000
  • The textile which is rotated in the tumbler dryer is dried by the heated air. the energy consumption for drying textile depends on various parameters. The objective of this study is to save the energy and the drying time. One of the various methods for energy saving is EGR(exhaust gas recirculation). We set the drying equipment for this study and perform the experimental study with the changes of the recirculation rate, the input power, and the air mass flow rate. We found the optimal drying conditions.

  • PDF

Characteristic of mixing rate of mud flat on Mortar in W/C 70% (W/C 70%인 모르타르에서의 갯벌 혼입률에 따른 특성)

  • Lee, Heung-Yeol;An, So-hyun;Yang, Seong-Hwan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.30-31
    • /
    • 2016
  • Recently in the construction site is required various performance of mortar to deal with reliability, economy. Especially of environment-friendly, saving resources and high performance of mortar it began to require improvement of performance. Therefore, in this study, a series of tests was designed to develop a using mud flat mortar in view of the high absorption rate of tidal flats, to fix the water cement ratio to 70%. The mixing ratio were 10:0, 9:1, 8:2, 7:3, 6:4, 5:5, 4:6 of fine aggregate and mud flats. Compared the flow value, chloride content, compressive strength, tensile strength, and workability of fine aggregate the substituted mud flat mortar and basic cement mortar, present the basic data on the characteristics and effects of mud flat mortar.

  • PDF

A Study on the Water Consumption of the Spring Chinese Cabbage in Greenhouse (온실재배 봄배추의 소비수량에 대한 고찰)

  • 윤용철;이종창;서원명;이근후
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.411-417
    • /
    • 1999
  • This study was performed to figure out an optimum water environment and to obtain the fundamental data related with saving labor and water consumption for the chinese cabbage being grown in greenhouse . The productivity of cabbage cultivated in boty pots and floor were compared to each other in the aspects of height and weight depending on the soil saturation levels. Obtained results are as follows. ; In case of pot cultivation , the height as well as weight of cabbage in 80% soil saturation level(P80) were measured to be larger than those in the other 2 soil saturation leves (P100 and P60). The weight of floor cultivated cabbages were relatively larger than that of pot cultivated ones. In accordance with saturation ration, the general trend of water consumption rate was maximum in P80 and was decreased in the order of P80 , P100 and P60. And the average indoor temperature as well as the plant growth rate were found to be closely related with water consumption rate.

  • PDF

Adaptive mode decision based on R-D optimization in H.264 using sequence statistics (영상의 복잡도를 고려한 H.264 기반 비트 율-왜곡 최적화 매크로블록 모드 결정 기법)

  • Kim, Sung-Jei;Choe, Yoon-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.291-292
    • /
    • 2006
  • This paper presents rate-distortion optimization that is considered sequence statistics(complexity) to choose the best macroblock mode decision in H.264. In previous work, Lagrange multiplier is derived by the function of constant value 0.85 and QP so that is not the proper Lagrange multilplier for any image sequence. The proposed algorithm solves the problem by changing constant value 0.85 into adaptive value which is influenced by image complexity, and by reducing the encoder complexity to estimate the image statistics with the multiplication of transformed, quantized rate and distortion. Proposed algorithm is achieved the bit-rate saving up to 5% better than previous method.

  • PDF