• Title/Summary/Keyword: sanitization efficacy

Search Result 4, Processing Time 0.018 seconds

Efficacy of Disinfectants and Sanitizers of Chlorine Oxide Bubbling Tablets (기포 발생형 타정제의 살균세정 효과)

  • Ji, Won Dae;Kang, Sang Gu;Lee, Kyung Eun
    • Journal of Life Science
    • /
    • v.25 no.9
    • /
    • pp.1036-1042
    • /
    • 2015
  • By using effective sanitizers, early block for transmission of pathogens is the effective way to prevent epidermic outbreaks. Here we developed a chlorine oxide bubbling type of sanitizing tablets and evaluated the disinfectant and sanitization effects. The sanitizers showed 99.999% of sanitization effect for Escherichia coli ATCC 10536 and Staphylococcus aureus ATCC 6538 strains for 5 min±10 sec on 20±1℃ in clean condition by dilution-neutralization method. It reduced more than 5 log10 cfu/ml of a legal permission standard of colony reduction. When a few used socks and underwear soaked for one hour in the 0.1% of the sanitizing tablets, no microorganisms were grown on CHROMagar plates. However, on CHROMagar plates of the no sanitizing tablets treated control, about 6.5×104 cfu/ml of Staphylococcus sp., Klebsiella sp. and Enterococus sp. were grown. Furthermore, the sanitizing tablets killed approximately 1.5x108 cfu/ml of E. coli BL21 in 5 minutes. Therefore, we concluded that the chlorine based bubbling type of sanitizing tablets satisfied the legal standard for the regulation of food and drug safety for disinfectants and sanitizers to pathogens and daily supplies.

Efficacy of Sanitizers Due to the Changes of Contact Time and Temperature (사용시간 및 온도조건 변화에 따른 살균소독제의 유효성)

  • Kim, Hyung-Il;Park, Sung-Kwan;Kwak, In-Shin;Sung, Jun-Hyun;Lim, Ho-Soo;Kim, Hoo-Jung;Kim, So-Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.4
    • /
    • pp.325-332
    • /
    • 2010
  • The bactericidal efficacy of three common sanitizers (100 or 200 ppm of sodium hypochlorite, 100 or 200 ppm of n-alkyl($C_{12}-C_{18}$)benzyldimethyl ehloride, and 50 or 100 ppm of peroxyacetie acid) against Escherichia coli ATCC 10536 and Staphylococcus aureus ATCC 6538 was studied using the suspension test method at various exposure temperatures (4~$40^{\circ}C$) and times(1~60min) under both dirty and clean conditions, respectively. During the suspension tests, sodium hypochlorite (200 ppm) showed higher bactericidal activity than the other sanitizers under clean conditions, with 5 log reductions against E. coli as well as S. aureus in the first 1 min of treatments at $4^{\circ}C$, However, the efficacy of sodium hypochlorite decreased markedly under dirty conditions due to its susceptibility to interfering substances. The efficacy of the n-alkyl($C_{12}-C_{18}$)benzyldimethyl chloride increased considerable as the exposure temperature and time increased. The bactericidal efficacy of the n-alkyl($C_{12}-C_{18}$)benzyldimethyl chloride might be less effective on low temperature, however, the longer time the sanitizer is in contact, the more effective the sanitization effect. Treatment with peroxyacetic acid (100 ppm) showed at least 5 log reduction against E. coli and S. aureus for 5 min at $4^{\circ}C$ under both clean and dirty conditions. The efficacy of the peroxyacetic acid was not much altered by interfering substances and aflected by changes in temperature or time.

Comparison Study on Efficacies of Disinfectants and Sanitizers Among Methods for Quantitative Surface Test (살균소독제의 정량적 표면시험방법별 유효성 비교)

  • Kim, Ae-Young;Kim, Yong-Su;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.3
    • /
    • pp.238-244
    • /
    • 2010
  • Currently, in vitro suspension tests using tubes are used as a authorized test method for sanitizers and disinfectants. However, the methods could not accurately assess the efficacy of sanitizers and disinfectant on the food-contacted surfaces in the field. This study evaluated the effectiveness of 5 kinds of representative sanitizers and disinfectants against E. coli and S. aureus to compare three quantitative surface testing methods that have been internationally standardized. As a result, the ASTM E2111-05 (ASTM(1)) test method obtained 5.18 $\pm$ 0.03 and 5.27 $\pm$ 0.04 log cfu/carrier reduction in dealing with E. coli and S. aureus, respectively, the ASTM E2197-02 (ASTM(2)) test method obtained 4.63 $\pm$ 0.04 and 3.97 $\pm$ 0.03 log cfu/carrier reduction and the CEN EN 13697 test method should 6.14 $\pm$ 0.05 and 5.31 $\pm$ 0.10 log cfu/carrier reduction in clean condition (CEN(1)) but 4.37 $\pm$ 0.02 and 4.06 $\pm$ 0.01 log cfu/carrier reduction in dirty condition (CEN(2)). Among them, CEN(1) showed the highest bactericidal effects, whereas ASTM(2) and CEN(2) revealed low performance (p < 0.05). In conclusion, the bactericidal effects of the ASTM(2) method and the CEN EN 13697 method adopting stainless steel were lower than the ASTM(1) method, which uses glass. The effectiveness assessment results among nationally accredited test methods were different each other. This implies that they could not fit for in the accurate evaluation of sanitization and disinfection on food-contact surfaces in practical food-processing fields. These results could be used as a basic data for establishment of an official surface test methods applicable in the field.