• 제목/요약/키워드: sanitary standard

검색결과 179건 처리시간 0.018초

한강으로 유입된 저질중의 중금속오염도 조사 (Studies on the Heavy Metal Contamination in the Sediment of the Han River)

  • 신정식;박상현
    • 환경위생공학
    • /
    • 제6권1호
    • /
    • pp.83-93
    • /
    • 1991
  • For the survey of water pollution, several heavy metals were analyzed in the sediment of the Han River from March 20 to April 22, 1989. The results were as follows : 1. The respective ranges of heavy metal concentrations of Cadimium, Lead, Copper, Zinc and Manganese found in the sediments of the Han River were 0.32!2.41 $\mu g/g$, 15.80~129.64 $\mu g/g$, 13.82~372.36 $\mu g/g$, 58.40~925.40 $\mu g/g$, 271.50~668.30 $\mu g/g$. 2. In the sediment of inflow site Jung Rang Chon the contents of Lead, Copper, Zinc were the highest among other sampling points and An Yang Chon, the contents of Cadmium, was the highest among other sampling points and Wang Sook Chon, the contents of Manganese, was the highest among other sampling points. 3. Through all sampling points general trend of heavy metal contamination showed the highest in Zinc, the next Manganese, Copper, Lead and Cadmium respectively. 4. The higher amount of heavy metal was found in the finer particles of sediment. 5. The amount of Cadmium and Lead of the Han River water was below the standard of environment.

  • PDF

과실 채소중 잔류농약(유기인제)에 관한 연구 (Organophosphorus Insecticide Residues in Fruits and Vegetables)

  • 윤숙자
    • 환경위생공학
    • /
    • 제5권1호
    • /
    • pp.83-92
    • /
    • 1990
  • Adapting two step aeration system to a waste water treatment of W-paper manufactory as Full-Scale Plants, we drew a following conclusion from its practical working. 1. Because BOD removal efficiency was 20% in A-Stage, 90% in B-Stage and total removal efficiency was 97%. It worked treatment plant well and was suitable for effluent water standard as well. Because COD removal efficiency was 42% in A-stage, 71% in B-stage and the total removal efficiency was 94% COD control was possible in effluent water quality. 2. Treatment efficiency according to a load capacity was average 20% in 1.401 BOD kg/m3/d load of A-Stage and average 90% in 0.273 BOD kg/$\textrm {m}^3$ / d load of B-Stage. 3. Treatment efficiency according to a ratio of F/M was 2.657--5.024 kg BOD/kg MLSS/d in A-Stage and BOD removal efficiency was 16-261 in the same stage. The ratio of F/M was 0.068-0.094 kg BOD /kg MLSS/d and BOD removal efficiency ratio was 85-94%. Therefore treatment efficiency could be kept stably and volume of aeration tank could be reduced wholly. 4. Treatment efficiency according to MLSS appeared BOD 20%. COD 42%, in A-Stage and removal efficiency appeared BOD 90%, COD 71% in B-Stage. They were suitable for plan condition. 5. Because of working of complemented treatment plant by AB-Process. 20,000,000 Won a month was saved than the ordinary working cost. Therefore, it was assumed that invested cost could be recollected in 19 months or so consequently.

  • PDF

주암호 유역의 강우사상에 따른 오염물질의 유출특성 (A Study of Comparison of outflow characteristics of pollutants by rainfall event of forest area near Juam lake basin)

  • 김남종;신대윤
    • 환경위생공학
    • /
    • 제22권4호
    • /
    • pp.87-104
    • /
    • 2007
  • The objective of this study is to estimate the load of pollutants caused from the forest area among non-point pollutants within the Juam lake. The surveyed forest area was classified into broad-leaved, conifer, mixed and herbage area by forest tree type. Water quality and flux were investigated under rainfall and non-rainfall, respectively. Then, pollutant loading was evaluated by using the values of unit pollutant loading factor of each point and area of forest zone. Water quality analysis results of runoff by forest tree types were as follows. - Annual BOD, $COD_{Mn}\;and\;COD_{Cr}$ concentration of runoff in conifer area was high, and particle and biological recalcitrant compounds were flowed highly. - SS, T-N and T-P concentration was high in runoff from broad-leaved area, and biological degradable compounds was flowed. - Water quality of water from valley was maintained good under non-rainfall and could be utilized as fresh drinking water. Through water quality standard investigation, a countermeasure establishment was necessary to secure a good quality of drinking water - BOD, $COD_{Mn},\;and\;COD_{Cr}$ concentration of Bo-sung river was higher 1.5 times than other 2 streams, and because of high T-N, and T-P concentration in Songgwang stream, the management for this was necessary.

Development of a Method to Quantify Lysine in Small Amount of Rice Grain

  • Kim, Joo-Shin;Kim, Kwang-Jin;Ma, Wing Chi Joyce;Chung, Hau-Yin
    • 환경위생공학
    • /
    • 제22권2호
    • /
    • pp.75-84
    • /
    • 2007
  • A lysine determination method for low quantity of rice was modified from the original Dye-Binding Lysine (DBL) method used in the national standard in China [GB 4801-84, 1984]. By making use of the property that lysine does not bind to the crocein orange G dye after treated with propionic anhydride, the amount of lysine in rice samples could be determined directly by calculating the difference between the absorbances of the treated and the untreated samples. Various commercial rice samples were purchased from market and evaluated. Several methods were tested by varying both the sizes of the samples and the concentrations of the dye solutions. Results showed that when using 1.284 mM of crocein orange G dye solution and 15.5 mg of sample, the results were most reproducible. The corresponding lysine content in sample were $3.36\;{\pm}\;0.09\;mg/g$ and $3.35\;{\pm}\;0.19\;mg/g$ by traditional method and modified method, respectively. Statistically, there was no significant difference between the results (p>0.05).

지하환경의 대기오염물질 규제에 관한 조사연구 (A Survey of the Air Quality in Underground Environment)

  • 이민희;한의정;신찬기;정해동;한자경
    • 환경위생공학
    • /
    • 제1권1호
    • /
    • pp.47-58
    • /
    • 1986
  • The underground living spaces have become one of the major environment of this decade in urban area. This study was carried out to examine contamination level for purpose of preservation of the pleasant underground environment. Three subway stations and three underground shopping centers in Seoul and two underground shopping centers in Busan were selected and surveyed by measuring gaseous pollutants $(SO_2,\; NO_2,\;CO,\;HC,\; HCHO,\;CO_2)$, dust, airborne microbes, and the other air condtions (temperature, humidity, air pressure, air flow, kata cooling power). These examined data were compared with four kinds of standard (building sanitation management, room air quality standards, occupational safety and health standards, ventilation equipment) as environmental hygiene.

  • PDF

자연수 및 먹는 물 중의 생물학적 분해가능한 용존유기탄소의 측정방법 개선에 관한 연구 (Upgrading the Measurement Method of Biodegradable Dissolved Organic Carbon in Natural Water or Drinking Water)

  • 이윤진;윤재섭;박준석;남상호
    • 환경위생공학
    • /
    • 제16권3호
    • /
    • pp.34-41
    • /
    • 2001
  • It is well known that bioassay on the low organic matters in water have developed from the two methods. One is assimilable organic carbon(AOC) that makes use of the maximum growth biomass of the pure strains for the standard substrates, the other is biodegradable dissolved organic carbon(BDOC) that determines the fraction of dissolved organic carbon(DOC) available for microbial utilization. The purpose of this study was to upgrade the measurement method of BDOC in natural water or drinking water. BBOC was determined by means of the bacterial growth and the DOC decrease at the same time. The origin inoculums were used to the suspended bacteria from Han River water, The initial optimum biomass and incubation time for initial DOC were induced by variation of nutrient repression and inoculums. The time reached to minimum DOC was selected as incubation time. The initial optimum biomass for Han river water was about 1000~5000 CFU/mL, respectively. In a sufficient biomass, suitable incubation time was about 3~5 day. It was indirectly calculated BDOC on maximum growth rate by measuring growth yield of indigenous bacteria. But it was difficult to adapt growth yield coefficient because of irregular bacterial growth. The measured 3 day BDOC was close to BDOC calculated with our proposed experimental equation between DOC and BDOC. It shows that the quantification of BDOC with this experimental equation can be used indirectly.

  • PDF

익산시의 부유먼지에 관한 연구 (Studies on the Total Suspended Particulates in Iksan City.)

  • 전병영
    • 환경위생공학
    • /
    • 제14권4호
    • /
    • pp.158-164
    • /
    • 1999
  • This study was carried out to investigate total suspended particulates (TSP) in Iksan area collected by nine stages Anderson air sampler and High volume air sampler from Jul. 1996 to Jul. 1998.The results are as follows1. The average of TSP concentration to be collected by Anderson air sampler and High volume air sampler in Iksan city are $59{\mu}g/m^3$, $67{\mu}g/m^3$. It was below the level of environmental standard. 2. The average of TSP concentration by measured method are HVAS > AS > Gov. 3. The average of TSP concentration on seasonal change are higher spring than winter. It were $65.5{\mu}g/m^3$ of Spring, $57{\mu}g/m^3$ of Summer, $52.5{\mu}g/m^3$ of Fall, $61{\mu}g/m^3$ of Winter. 4. Particle size 3istribution of atmospheric particulate was divided into two groups, coarse group was made by particles larger than $1.1-2.1{\mu}m$ in diameter and fine groups smaller than $1.1-2.1{\mu}m$ in diameter. about 50% of total suspended particle measured by Anderson air sampler during the sampling period was coarse particle.

  • PDF

이온크로마토그래프를 이용한 수중의 퍼클로레이트 농축 및 분석 (Analysis of Perchlorate in Water Using Ion Chromatograph with Preconcentration)

  • 김학철
    • 환경위생공학
    • /
    • 제21권4호
    • /
    • pp.29-38
    • /
    • 2006
  • This study included the development of analytical method for determining perchlorate in water sample. The analytical condition was referred in EPA 314.0 method which use ion chromatography and the concentrator column was replaced by the guard column. Concentrating 10mL raw or treated water sample on to AGl6 guard column made it possible to get the LOD(Limit of Detection) of $0.73\;{\mu}g/L$. The total run time was 11 minutes and during run time next sample could be concentrated on AGl6 guard column. Compared to the Concentration method which needed manual operation, the Direct Injection method could screen the many water samples. The LOD of the Direct Injection method was higher and the sensitivity was lower than that of the Concentration method. The RSDs(Relative Standard Deviations) were lower than 2.5 % for peak height and 0.7 % for retention time in pre-concentration methods. This method Showed good reproducibility and reliability and it was thought the deviations of recovery value could be reduced by considering column capacity and making water sample homogeneous. Matrix Elimination could be done using the pre-concentration method if perchlorate were in complex matrix of sample.

폐기물처리시설 입지선정에 따른 사례연구 (A Case Study for Site Selection of the Waste Treatment Facilities)

  • 이해승
    • 환경위생공학
    • /
    • 제19권1호
    • /
    • pp.24-36
    • /
    • 2004
  • This study is to investigate the present condition of waste disposal establishment and to analysis problems which could be produced at location selection formalities of waste disposal establishment. It proposed building methods of waste disposal establishment to lead spontaneous participation of local resident according to case analysis of waste disposal establishment. There are research results; i) Opposition of inhabitants was the majority of reason at the business abandonment or delay of waste disposal establishment. Therefore agreement formation course with local inhabitants is most important position. ii) Many estimate have been needed for waste disposal establishment, but support estimate of government was 30-50% that is really low compare with other environmental establishment. So that it need to increase of government estimate. iii) Location collection is carried out based on law and final collected location must be executed without delay of relation business as soon as possible. iv) Standard of location collection has to divide into small, middle and large size and to apply with same rule according to divided location. v) It must be change public subscription before and location selection after and maintain continuance of information offer to local inhabitants and offered information. vi) after building of waste disposal establishment for solving distrust of waste disposal establishment. It must be planed and carried on useful support countermeasure to local inhabitants in actuality.

하수슬러지 소각시설의 중금속 배출특성에 관한 연구 (Study on the Emission Characteristics of Heavy metals in sewage sludge Incinerator)

  • 박정민;이상보;김민정;김진필;김종춘;이석조;이상학
    • 환경위생공학
    • /
    • 제24권3호
    • /
    • pp.28-36
    • /
    • 2009
  • We have closely examined the concentration change characteristics, emission amounts, and the material balance of hazardous air pollutants at both early and later stages of the prevention facilities. These results will be uses as the basic data when preparing for the regulatory and management plans for hazardous air pollutants. The results of the study on heavy metals illustrated that the content of heavy metals in sludge across five facilities were as follows: copper> zinc> chrome> nickel> cadmium> mercury. In terms of heavy metal content in swage sludge, the sludge in incinerating facilities other than the sludge in the D incinerating facility containing industrial water waste, was examined in order to satisfy the ocean contamination standard and fertilizer specifications. Most of the items were shown to have satisfied the emission tolerance standards in the latter part of the prevention facilities(The average elimination rate was over 90%). Therefore, it is concluded that swage sludge containing high-concentrate heavy metals needs to be incinerated rather than recycled as fertilizer.