• Title/Summary/Keyword: sanitary standard

Search Result 179, Processing Time 0.039 seconds

Factors Related to Sanitary Management Performance Based on HACCP System in School Foodservice - Seoul, Gyeonggi, Kangwon and Choongchung Areas in Korea - (HACCP 시스템 적용 학교급식 위생관리 수행수준에 영향을 미치는 요인 - 서울, 경기, 강원, 충청지역을 중심으로 -)

  • Kim, Gyoung-Mi;Lee, Sim-Yeol
    • Korean Journal of Community Nutrition
    • /
    • v.14 no.6
    • /
    • pp.817-830
    • /
    • 2009
  • The purpose of this study was to analysis the sanitary management performance based on HACCP system for school foodservice. This study was carried out from September 2008 until December 2008 and is targeted towards schools' dietitians that work at schools with school foodservice. The regional distribution of this research is as follows; 377 schools in Seoul, 648 schools in Gyeonggido, 160 schools in Kangwondo, 438 schools in Choongchungdo equaling 1,623 schools in total. When school foodservices were put through sanitation management achievement level analysis applied by the HACCP system, results displayed that management of temperature (3.96 points), time (4.08 points), and cross-contamination (4.07 points) were all below the average achievement level. HACCP system's achievement level based on the TQM showed that areas for strategy development, leadership, information and analysis had low achievement levels. Achievement levels for CCP are quality check, delivery/distribution process, sterilization/cleansing of food's contact surface. As a result of multiple regression analysis of the factors that influenced sanitation management achievement level of school foodservice HACCP system; sanitary job standard showed 35.6% and CCP achievement levels showed 26.8% explanatory rate. In particular, Kangwondo's number of foodservice provided to per cook was small. Also, the better the processing management was assessed, the higher the sanitary job standard achievement level became resulting to a explanatory rate of 39.5%. Elementary schools showed a higher explanatory rate of 37.0% than middle and high schools. CCP achievement levels in middle and high schools with self-operated foodservice had a 28.0% variable explanatory rate, which was the highest. The better the drainage system, leadership and assessments turned out to be, the higher the CCP achievement levels became. In summary, to revitalize HACCP system that is based on the TQM, it is considered that proper database of HACCP system for school foodservice's sanitation management be constructed and more emphasis should be put on strategy development to improve customers' satisfactory level. In addition, improvements in achievement levels of time, temperature, and cross-contamination for sanitary job standard and CCP achievement level are essential.

A Study on the Indoor Environment of school classrooms in Seoul area (서울지역 학교 교실의 실내환경 조사연구)

  • 최한영
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.2
    • /
    • pp.67-74
    • /
    • 2003
  • In 15 schools where were chosen each location (East, West, South, North, Central) of Seoul area, 9 items were measured such as thermo circumstance(temperature, relative humidity, air current, intensity of illumination) particulate matter, carbon monoxide, sulfur dioxide, and nitrogen dioxide being based on the school indoor environment standard. It was showed that indoor temperature, relative humidity and air movement were suitable in comparison with school indoor environment standard. Intensity of illumination was suitable in comparison with all schools, only exception 2 schools. In all investigated schools were adequate for carbon monoxide, sulfur dioxide and nitrogen dioxide, in which each indoor environment standard (10ppw, 0.25ppm/hr, 0.15ppm/hr), but in 5 schools the carbon dioxide were exceeded for standard limit 1,000ppm of Korea. Indoor concentration of dust(PM-10) induced from respiration dust the standard of Korea ($150{\mu}g/m^3$) at all schools.

A Survey of Water Quality and Improvement Measure of Imjin-River (임진강수계의 수질조사 및 개선방안)

  • 김형진;백영석;이준석
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.1
    • /
    • pp.66-75
    • /
    • 1995
  • This survey is executed about the water quality and improvement measure of Imjin- river. The results are summarized as follows; 1 ) Ammonia nitrogen concentration in tap water was two times higher than drinking water standard. 2) The concentration of BOD in textile wastewater was 235ppm which is higher than wastewater distribution standard and leather wastewater showed high nitrogen concentration. 3) Water quality of the Imjin- river upstream was not in problem but that of Shin- stream showed somewhat high concentration in BOD, COD, and ammonia nitrogen. Especially the detected Cynide compound on the lower of Shin- stream implied seriously polluted condition. 4) The heavy metal in soil of the river bed was not detected but iron, zinc was detected to high concentration. 5) It Is urgently suggested to build more municipal sewage and sanitary treatment plants, and run dredging and river bed rearrangement project. 6) The Construction of the wastewater treatment complexes of relevant industries shall be propelled as soon as possible.

  • PDF

Relationships between Actual Sanitary Management Practices during Production and Distribution, and Microbiological Quality of Dosirak Items Marketed in CVS (편의점 판매용 도시락 생산 및 유통과정시의 위생관리 실태와 시판제품에 대한 미생물적 품질간의 상관관계)

  • Kwak, Tong-Kyung;Kim, Sung-Hee
    • Journal of the Korean Society of Food Culture
    • /
    • v.11 no.2
    • /
    • pp.235-242
    • /
    • 1996
  • Sanitary management practices from 8 packaged meals (Dosirak) manufacturing establishments were surveyd during production and distribution and their microbiological quality of dosirak items marketed in CVS were analyzed. Correlation coefficients were calculated to deternine significant relationships between sanitary management practices and microbiological quality of packaged meals. The results of self evaluation on sanitary management practices indicated 'doing practice well' in personnel and equipment sanitation management but time-temperature control management were practiced satisfactorily only about 55% as compared with the managerial standard guidelines. Significant relationships between the status of actual sanitary management practices and microbiological quality of Dosirak items were not found, but general status of microbiological quality of Dosirak items revealed positive relationship with the size of operational structure and the status of time-temperature control management practices.

  • PDF

An Analysis of the Improvement of Food Labelling Standard based on Consumerism (소비자주의(消費者主義)에 입각(立脚)한 식품(食品)의 표시제도(表示制度) 개선(改善)에 관한 연구(硏究))

  • Nam, Sang-Duck
    • Journal of the Korean Society of Food Culture
    • /
    • v.3 no.2
    • /
    • pp.211-217
    • /
    • 1988
  • The Main objective of this study is to find consumer attitude toward the Sanitary Regulation of Foods. In view of consumerism, this result will be used in re-regulating the law. Among the Sanitary Regulation of Foods, this study focuses on the Standard of prepackaged Food Labelling, because it is related both with the advertising from the food manufacturer's point of view and with the perception about the food itself from the consumer's point of view. After reviewing the previous studies and related provisions about the Standard of Prepackaged food Labelling, and compare other sanitary regulation of foods in developed countries (U.S.A. and Japan), basic research framework was derived. The research framework focuses on the user perception about the validity of provisions about the Standard of Prepackaged Food Labelling, and on the existance of exaggeration in food advertising using prepackaged foods. Data were collected through questionaires from the sample covering 374 food customers. The data were analyzed by frequency test and the important findings of this study are as follows. Most food consumers consider such provisions as date of manufacturing, circulation time limit, cautions for food handling, price, and manufacturer as important factors in buying food products. Among these factors, the date of manufacturing and circulation time limit are most critical factors, and must be labelled correctly on the prepackaged food cover. But other provisions which do not affect on consumer's buying decision (e.g. business admission number, self standard number) need not be labelled. From this study, we can conclude that the provisions about the standard of prepackaged Food Labelling currently used must be devided into two parts. One is 'mandatory provisions' which must be obeyed by all food manufacturets, and the other is 'autonomous provisions' which need not be obeyed by all food manufacturers. And mandatory provisions need to be regylated more strongly than now.

  • PDF

A Study on the Sanitary Piping System Plan When an Aged Public Housing is Remodeled (노후 공동주택의 위생설비 리모델링 계획방안에 관한 연구)

  • Han, Soo-Gon;Lee, Sang-Youp;Lee, Seung-Yeon;Hong, Min-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.569-574
    • /
    • 2008
  • Recently, the domestic remodeling market is increased in scale. This study is to develop the sanitary piping system which improves quality of life and facility performance when the aged public housing is remodeled. Above all, we found out three standard floor plans in bathrooms of the public housing. And then, the plan and section types of the sanitary piping system were developed for the on-floor piping, a construction cost of each section types was estimated to review the economical fact. Also, the field mock-up test was performed in the type of the pipe shaft with on-floor pit. In result, the developed sanitary piping system was available for the remodeling public housing without a great facility cost. Additionally, the sanitary pipe was replaced easily through the shaft and on-floor fit. And a noise was reduced to a lower unit when the water flowed down.

  • PDF

A Study for the Improvement of the Sanitary Condition as well as Quality of Foods Served in Various Types of Restaurants in Seoul City Area (서울 시내 요식 업소의 위생 상태 및 급식되는 음식의 미생물적 품질 개선을 위한 연구)

  • 곽동경;박경해
    • Journal of Food Hygiene and Safety
    • /
    • v.1 no.2
    • /
    • pp.121-131
    • /
    • 1986
  • Four types of restaurants in Seoul city area were aSsessed in terms of the sanitary conditions and practices, and the microbiological quality. Sanitary check-lists were developed to evaluate the sanitary condition of sampled restaurants. Subjective samples were randomly selected based on the distribution factors of areas, types, and sizes. Microbiological tests on foods, equipments, and utensils were done according to standard procedures and included total plate count and coli forms. Singnificant differences among types or sizes were determined by using one-way analysis of variance. Correlation coefficients were calculated to determine significant relationships between sanitary scores and microbiological counts. The results of the study are summarized as follows: 1) Sanitary condition of kitchen and dining areas as well as the sanitary practices of employees were evaluated as the unsatisfactory state with potentially hazardous practices observed. 2) The microbiological quality of food items with high cooking temperature was in good condition, but most food items showed high levels of microbiological counts mainly due to the improper food handling practices of employees. 3) The sanitary conditions of equipment and utensils which were used at preparation and cooking phases, and food containers which were used at the serving phase, were crucial. Serveal guidelines were suggested for the improvement of the working environment as well as the food Quality.

  • PDF

Application for Measuring the Glucose, Ammonia nitrogen, and Tylosin Concentration using Near Infrared Spectroscopy

  • Kim, Jong-Soo;Cho, Hoon
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.2
    • /
    • pp.19-25
    • /
    • 2008
  • For measurement of tylosin, ammonia nitrogen, and glucose concentration during the culture of Streptomyces fradiae using Near Infrared Spectroscopy, the calibration using various mathematical models was performed and then, based on the linear model, the validation was carried out. In the case of sucrose concentration using the MLR method, the Standard Error of Prediction and Multiple correlation coefficient were 1.97, and 0.991, respectively. In the case of ammonia nitrogen concentration using the PLSR method, the Standard Error of Prediction and Multiple correlation coefficient were 0.13, and 0.990, respectively. In the case of tylosin concentration using the PLSR method, the standard Error of Prediction and Multiple correlation coefficient were 0.54, and 0.984, respectively.

Food Sanitation Management at Foodservice of Correctional Institutions in Korea (교정시설 급식에서의 위생관리 실태조사)

  • Cho, In-Jae;Lee, Hye-Sang
    • Journal of the Korean Dietetic Association
    • /
    • v.17 no.3
    • /
    • pp.302-312
    • /
    • 2011
  • The purpose of this study was to investigate the equipment ratio of sanitary facility/equipment as well as the sanitary management performance level at foodservice of correctional institutions in Korea. For this purpose, a total of 47 questionnaires were distributed to dietitians working at correctional institutions during the period from March 20th to May 18th of 2008. A total of 38 questionnaires (response rate 81%) was analyzed using SPSS (windows ver. 14.0). The majority of the respondents were females (65.8%), 35 years or older (55.3%), with 7 years or longer experiences (65.8%), and with education level of university or higher (60.5%). Among the institutions, 39.5% had less than 500, 28.9% had 501 or more but less than 1,200, and 31.6% had 1,201 or more inmates. The equipment ratio of the sanitary facilities/equipment was 49.7%, which was relatively low. Most dietitians perceived 'limited availability of facilities and equipment' and 'the lack of support from financing department' as the major barriers in implementing a desirable sanitary system. On the other hand, perceived sanitary management performance was rated by the respondents as being between 2.55 to 4.50 (5-point Likert scale)-'Cleaning hands properly as specified' showed the lowest performance, whereas 'Sampling preserved meals by standard methodology' showed the highest. The results of this study suggest that a sanitary education program designed for inmate food handlers is needed for successful sanitary management.

Proposal of unification plan based on differences between food and livestock product HACCP (식품과 축산물 HACCP의 차이점 분석 및 일원화 방안 도출)

  • Jo, Ah-Hyeon;Kang, Ju-Yeong;Park, Eun-Ji;Lee, Han-Cheol;Lee, Cheol-Soo;Kim, Jung-Beom
    • Food Science and Industry
    • /
    • v.53 no.1
    • /
    • pp.101-115
    • /
    • 2020
  • Korea has been managed HACCP with food and livestock products separately, but it was incorporated into food and livestock product safety management certification standard in 2015. Currently, the notification is unified, but food sanitation act and the livestock products sanitary control act are not unified. These differences are leading to complaints from food and livestock corporation. In this review, the food sanitation act, enforcement regulations of the food sanitation act, the livestock products sanitary control act and enforcement regulations of the livestock products sanitary control act were compared and analyzed to identify the part which requires unification. As a result of the survey, the thirteen clauses were proposed to unify in the food sanitation act and the livestock products sanitary control act. The nineteen clauses were proposed to unify in enforcement regulations of the food sanitation act and enforcement regulations of the livestock products sanitary control act.