• Title/Summary/Keyword: sanitary quality

Search Result 330, Processing Time 0.028 seconds

Bacteriological Quality of Sea Water at Swimming Beaches in Busan Area (부산시내 해수욕장해수의 세균학적 수질에 관한 연구)

  • KIM Yong-Kwan;CHANG Dong-Suck
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.14 no.3
    • /
    • pp.148-157
    • /
    • 1981
  • This experiment was carried out to evaluate the sanitary quality of sea water at popular swimming beaches such as Haeundae, Kwanganri and Songjeong which are located in the suburbs of Busan Korea. One hundred and seventy five sea water samples were collected from the 25 stations during the both summer seasons in 1979 and in 1980. The sampling stations were established in the above 3 swimming beaches and the estuary of Suyeong river (See Fig.1.). To evaluate the sanitary quality, coliform group, fecal coliform, viable cell count and Vibrio parahaemolyticus were observed. The median value of coliform group MPN of the samples ranged 2,300 to 6,500/100m1 in Kwanganri, 670 to 910/100m1 in Haeundae and 430 to 460/100m1 in Songjeong swimming beach. Geometric mean of fecal coliform MPN was 3,200/100m1 in Kwanganri, 500/100m1 in Haeundae and 360/100m1 in Songjeong swimming beach. Composition of coliform was $23\%$ Escheri-chia coli group, $20\%$ Citrobacter freundii group, $41\%$ Klebsiella aerogenes group and $16\%$others. The density of Vibrio parahaemolyticus in Kwanganri was much higher than those of in other beaches by 5 to 6 times. Plate count of the samples in the estuary of Suyeong river was varied from 300 to $8.5\times10^6/ml$ during the study period. No remarkable difference was observed in bacterial density by tide in swimming beaches but the bacterial density of sea water at ebb tide was obviously higher than those of the samples at flood tide in the estuary of Suyeong river.

  • PDF

The Occupant Perception and Investigation of Indoor Air Quality at Home in Seoul

  • Sohn, Jong-Ryeul;Kim, Young-Whan;Byeon, Sang-Hoon
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.1
    • /
    • pp.51-57
    • /
    • 2003
  • Indoor air quality(IAQ) in workplace and residential environments has been concern of people. Recently, Ministry of Environment in Korea has recognized the potential risk on the healthy effect related to indoor air pollution at home. Therefore, the purpose of this study was performed to measure the indoor air pollutants of IAQ at different homes and investigate to compare the perception of IAQ recognition at home from questionnaire survey in Seoul. We estimated the IAQ of selected 6 homes based on site region and housing type. The indoor air pollutants and parameters such as temperature, relative humidity, respirable suspended particulate matter($PM_{10}$), formaldehyde(HCHO), total bacteria counts, carbon monooxide(CO) and carbon dioxide($CO_2$) were monitored for summer and winter. In monitoring results, the respirable suspended particulate matter(($PM_{10}$) and indoor airborne bacteria level of home 5 and 6 were higher than the standard of the public $150{\;}{\mu}g/m^3$ and $500{\;}{\mu}g/m^3$, the level formaldehyde(HCHO) was exceed 0.1 ppm of the standard of Korea at all monitored homes. In statistics analysis, we could find a correlation between the building age and the concentration of CO, TBC were significant at 0.01 level and Relative Humidity was significant at 0.05 level for summer. Finally, the important air pollutants of IAQ in home were HCHO and total bacteria counts(TBC). And we performed a questionnaire survey of 500 people about their awareness for the importance of IAQ in our home during same period. In results, all most response of occupant has recognized the importance of IAQ at home. Therefore, it can be concluded that the IAQ of selected 6 home studied was perceived as acceptable, it is recommended that the government related IAQ was suggested the guideline and control of IAQ problems, and the occupants need to be effort to reduce the exposure of sources to undesirable pollutants.

Microbiological Quality and Growth and Survival of Foodborne Pathogens in Ready-To-Eat Egg Products (즉석섭취 알 가공품의 미생물학적 품질 및 주요 식중독 균의 증식·생존 분석)

  • Jo, Hye Jin;Choi, Beom Geun;Wu, Yan;Moon, Jin San;Kim, Young Jo;Yoon, Ki Sun
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.2
    • /
    • pp.178-188
    • /
    • 2015
  • Microbial quality of baked egg products was evaluated by counting the levels of sanitary indicative bacteria (aerobic plate counts, coliforms, and E. coli), L. monocytogenes and Salmonella spp. at the critical control points (CCPs) of manufacturing process. In addition, the survival and growth of foodborne pathogens in various egg products (cheese, tuna, tteokgalbi, pizza omelets, baked egg, and steamed egg) were investigated at 4, 10, and $15^{\circ}C$. The contamination level of aerobic plate counts decreased from 4.67 log CFU/g at CCP 1 to 0.56 log CFU/g at CCP 3 in baked egg products. No coliforms and E. coli were detected at all CCPs. Although L. innocua and Salmonella spp. were identified at CCP 1, no L. monocytogenes and Salmonella spp. were detected in the final products. The contamination levels of aerobic plate counts and coliforms in egg strips and number of aerobic plate counts in Tteokgalbi omelet are higher than the microbiological standard of processed egg products. At $10^{\circ}C$, the growth of all pathogens was not prevented in omelet and baked egg, but the populations of S. Typhimurium and E. coli were reduced in steamed egg at $10^{\circ}C$, regardless of the presence of other pathogens. The growth of L. monocytogenes was faster than that of S. Typhimurium and E. coli in omelet. More rapid growth of S. Enteritidis than S. Typhimurium was observed in egg products, indicating the greater risk of S. Enteritidis than S. Typhimurium in egg products.

Assessment of Sanitary Management Practices of School Foodservice Operations in Seoul (서울지역 학교급식 위생관리 실태평가)

  • Kwak, Tong-Kyung;Hong, Wan-Soo;Moon, Hye-Kyung;Ryu, Kyung;Chang, Hye-Ja
    • Journal of Food Hygiene and Safety
    • /
    • v.16 no.3
    • /
    • pp.168-177
    • /
    • 2001
  • Sanitary management practices were assessed to insure the safety of school foodservice, to prevent the outbreak of foodborne illness, and to improve the quality of school foodservice. To accomplish these objectives, a survey was conducted and analyzed on elementary and high school foodservice operations located in Seoul area. A Questionnaire from based on HACCP standards was developed and used for self-reported evaluation of the school foodservice managers on their sanitary management practices. The results were analysed by examining their activities and identifying weaknesses in those activities. The questionnaire was composed of three sectors with all 53 questions; 33 questions for time-temperature management, 5 for personal hygiene and 15 for equipment/facility sanitation. Five-point-scale was used on the questionnaire answers. Among the schools responded,253 (98.4% of the total) were elementary schools and 19 (1.6%) were high schools. Among the three sectors, personal hygiene performance was mostly well conducted by marking average 4.06$\pm$0.57. Equipment/facility sanitation came next by marking average 3.84$\pm$0.53. Time-temperature marked average 3.45$\pm$0.46. “Storage after cooking (2.03$\pm$0.94)”was identified as the least managed activities because the school foodservice operations were not equipped well with hot holding and/or cold holding. “Separate use of sink per usage (3.03$\pm$1.10)” and “proper location of hand washing facility (3.07$\pm$1.13))” were identified as the least practiced activities in equipment/facility sanitation sector. To enhance these practices, proper number of sinks and hand washing facilities should be equipped first within the kitchen area.

  • PDF

Hygienic Quality of Drinking Water Served in Restaurants and Quality Characteristics of Drinking Water Boiled with Various Plant Materials (외식업소 음용수의 위생실태와 침출재료에 따른 기호성과 저장성)

  • Ahan, Yu-Bok;Jeong, Eun-Ju;Lee, Shin-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.3
    • /
    • pp.159-164
    • /
    • 2007
  • The viable cell of 60% drinking water among 25 drinking water served in restaurant of Daegu district showed above 100 CFU/mL which is sanitary standard of drinking water. The 50 CEO of restaurant considered drinking water served in their own restaurant as just safe and were very deficient in aware of sanitation about drinking water. Sensory quality of drinking water boiled with plant materials, such as barley, Cassia semen, corn, Buckwheat, Korean solomon's seal, Chamomile, Brown rice-green and peppermint was improved in color, taste, flavor and overall acceptability compare to marketed drinking water, respectively. Especially drinking water boiled with Korean solomon's seal was the best In overall acceptability. The number of total bacteria reached above $10^2 CFU/mL$ in marketed drinking water after 4 days storage at 10. But the growth of microorganism did not occur in boiled drinking water with Brown rice-green tea, Korean solomon's seal, barley, Cassia semen and com during storage for 10 days at $10^{\circ}C$, respectively. The number of total bacteria reached above $10^2 CFU/mL$ in marketed drinking water after storage for 1 days at $25^{\circ}C$. The growth of microorganism was accelerated in boiled drinking water with corn, Korean solomon's seal, barley, Cassia semen except Brown rice-green tea during storage far 10 days at $25^{\circ}C$, respectively.

The Effects of Scale Growth Inhibition on Water Pipe using Frequency Driver (Frequency Driver를 이용한 냉온수관의 스케일 방지억제효과)

  • Jang, Mi-Jeong;Sung, Il-Wha
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.258-266
    • /
    • 2011
  • Scale induced by hardness materials in water must be controled because of it can be result in remarkable damages of pipeline as well as water quality deterioration. Especially hot water system is one of scale management required facility as scale formation can be accelerated by temperature. The scale control performance of frequency driver (FD) was tested instead of existing methods such as chemical, physical and electromagnetic methods which needs chemicals and electric power. Three kinds of pipe coupons were submerged in test water with 500 mg/L of hardness for 33 days and XRD and SEM were analysed for comparing scale formation characteristics of these coupons. Calcite ($CaCO_3$) which came from hardness of water was formed on only cast iron pipe coupon and this coupon showed higher corrosion rate than copper and stainless steel pipe coupon. Hot water circulating system connected cast iron pipe with and without FD was operated with 300 mg/L of hardness water at $50^{\circ}C$ for monitoring of scale formation and water quality with and without FD. XRD showed that FD leaded to magnetite ($Fe_3O_4$) scale which is good scale for preventing corrosion than calcite and SEM image also indicated the scale control effect of FD. Scales of 16% on pipe joint, 14% on pipe length, and 42% on heat exchanger decreased with FD comparing scales of those parts without FD. From the results of water quality, FD reduced crystallization of hardness material without chemical reaction in water and it can indicate that FD is safe and proenvironmental technology for scale reduction.

Impact of Pollution Sources on the Bacteriological Water Quality in the Yongnam-Gwangdo Shellfish Growing Area of Western Jinhae Bay, Korea (진해만 서부 용남·광도해역의 세균학적 수질에 미치는 육상 오염원의 영향)

  • Shim, Kil Bo;Ha, Kwang Soo;Yoo, Hyun Duk;Lee, Tae Seek;Kim, Ji Hoe
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.45 no.6
    • /
    • pp.561-569
    • /
    • 2012
  • To evaluate the bacteriological water quality in Yongnam-Gwangdo, located in western Jinhae Bay, seawater samples were analyzed using sanitary indicator bacteria at 57 sampling stations. According to survey results from January 2007 to December 2009, the range of the geometric mean and the estimated 90th percentile for coliforms and fecal coliforms in the samples were <1.8-16.5 and 1.8-246.8 MPN/100 mL and <1.8-7.1 and 1.8-74.8 MPN/100 mL, respectively. The samples, including those taken from stations located in Wonmunman, Gwangdo, and Dangdong, showed high levels of microbial contamination caused by the climate and weather patterns in the marine environment. The bacteriological water quality in the area met Korean criteria for a designated shellfish growing area for export and National Shellfish Sanitation Program criteria for an approved shellfish growing area, except at station #49. A total of 24 direct pollution sources were discharged into the shellfish growing area. The radius of impact was calculated for each pollution source to assess the effect on the shellfish growing area. The calculated radius of impact for most of the pollution sources was below 300 m. However, the radius of impact for the combined pollution sources in Kyeonnaeryang was 93-1973 m. There were significant differences between the calculated closed sea area and actual monitoring results. The closed sea area values calculated from the fecal coliform load in drainage water tended to be higher than the actual monitoring results. Tidal currents and environmental factors such as salinity, water temperature, sunlight, and microbiological factors affect the survival of fecal indicator bacteria in seawater.

Evaluation of the Influence of Inland Pollution Sources on Shellfish Growing Areas after Rainfall Events in Geoje Bay, Korea (강우에 따른 거제만해역 육상오염원의 영향평가)

  • Ha, Kwang-Soo;Yoo, Hyun-Duk;Shim, Kil-Bo;Kim, Ji-Hoe;Lee, Tae-Seek;Kim, Poong-Ho;Ju, Ja-Yeon;Lee, Hee-Jung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.44 no.6
    • /
    • pp.612-621
    • /
    • 2011
  • The influences of inland pollution sources because of rainfall events on the bacteriological water quality in Geoje Bay, a major shellfish production area in Korea, were investigated. The sanitary status of sea water and shellfish after rainfall events was also evaluated. The flow rates of 13 streams around Geoje Bay showed 6 to 7-fold increases after 15 to 21 mm of rainfall. Peak pollution was observed in the Naegan Stream, the Gandeok Stream and the Seojeong Stream. The calculated impact area of inland pollution sources was 3.1 $km^2$ immediately after 15 mm of rainfall and expanded to 3.5 $km^2$ after 24 hours. These calculations of impacted area matched results from fecal coliform analyses with sea water. The distance between the major pollution source in the bay (the Gandeok Stream) and the station with the worst bacteriological water quality immediately after 15 mm of rainfall, which was below the Korean standard, was 0.8 km in a straight line; this distance increased to 2.0 km after a period of 24 hours. The area impacted by inland pollution sources after a 15 mm rainfall event was wider than after a 21 mm rainfall. Although the flow rate from inland pollution sources was higher, the concentration of fecal coliform in the discharged water was lower after higher rainfall events. These observations corresponded with the results of fecal coliform analyses with sea water samples. According to the evaluation of the influences of inland pollution sources and fecal coliform analyses on sea water and shellfish samples in Geoje Bay, pollutants from inland sources did not reach the boundary line of the shellfish growing area after rainfall events of 15 or 22 mm. The bacteriological water quality of the shellfish growing area in Geoje Bay met the Korean standard and US NSSP requirements for approved shellfish growing areas.

A Study of Rural Residential Space for Child-rearing Households (농촌 자녀양육 가구의 주거공간 실태조사 연구)

  • Lee, Yeun-Sook;Kim, Jin-Goo;Heo, Hye-Young
    • Journal of the Korean housing association
    • /
    • v.27 no.2
    • /
    • pp.21-31
    • /
    • 2016
  • In recent rural areas, unlike the past, the young population is increasing with the growth of the agricultural industry and the quality of life-focused trend. Therefore, the rural areas need to more actively respond to the housing demands of the young generations. In this regard, this study aimed to research the housing conditions of the households with children and identify any problems. The study targeted 16 families with children in Deokpo-ri, Yeongwol-gun, Gangwon Province. The research was conducted based on the on-site case study, specifically face-to-face in-depth interview and on-site monitoring using the checklist by residential spaces. The research findings are as follows: The discovered issues include the storage size and safety issues in the movement space, failure to provide the space tailored to the characteristics of the children and the insufficient size and storage space in the living space and the size and safety issues in the sanitary space. Overall, it was identified that small and insufficient storage space in the house pointed out as the main issue in this research was getting the residents' life more uncomfortable and unreasonable, and the activities of the children made their parents do unnecessary behaviors and stressed out during the process of childrearing. Therefore, it is necessary to consider the space arrangement considering the organizing system, caring system and the behavioral characteristics of the children during the process of child-rearing.

A Study on Interferences of Monochloramine in the Measurement of Ammonia by Phenate Method (Phenate 법으로 암모니아 분석시 염화아민의 방해 작용에 관한 연구)

  • Yoon, Je-Yong;Lee, Sang-Duck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.1
    • /
    • pp.45-51
    • /
    • 1998
  • The determinations of ammonia in water for drinking purpose served as one basis of judging the sanitary quality of water for a great many years. However, presently ammonia regulation varies depending on countries. In USA and Canada, ammonia is added to water for chloramination process. However, for korea, there is ammonia regulation of treated water in Korea which should not exceed 0.5mg/l as $NH_3-N$. There was a report exceeding 0.5mg/l of ammonia in chlorinated water when the famous drinking water contamination episode happened in the downstream of Nadong River, 1994. With lack of sewer distribution system and treatment plants of domestic wastes, many water treatment plants have a difficulty of complying with ammonia regulation in treated water. Breakpoint chlorination is usually performed to get rid of ammonia. The method which is allowed to measure ammonia in Korea is Phenate method. However, it would be undesirable to use Phenate method for measuring ammonia in chlorinated water if Phenate method would not differentiate ammonia from chloramine. A good possibility of interferences in measurement of ammonia exists because Phenate method include the step of the formation of chlorine and would not differentiate chloramine which is formed as a result of reaction between chlorine and ammonia. This study was on inaccuracy of Phenate method for measuring ammonia of chlorinated water when chloramine and ammonia coexist. This study found that Phenate method measured all chlormaine as ammonia. Ammonia measurement by ion chromatography confirmed this results. Finally, the result from this study suggests that ammonia measurement by Phenate method in chlorinated water should be revised accordingly.

  • PDF