• Title/Summary/Keyword: sanitary quality

Search Result 330, Processing Time 0.026 seconds

Treatment of stock wastewater by flocculation with Calsium and Magnesium salts (칼슘과 마그네슘염을 이용한 축산폐수의 응집처리)

  • 김재용
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.4
    • /
    • pp.10-18
    • /
    • 2002
  • The changes of conventional clarification processe and an increase in treatment cost are required to meet increasingly stringent regulations related to the treated water quality. Although many enhanced coagulations have introduced to improve organic matter removal, the results to remove color, nitrogen and phosphorus as well as organic material have not been very efficient yet. In this context as new flocculation using calcium hydroxide and magnesum sulfate was carried out. The removal of waste matters such as SS, organic matter, COD, nitrogen and phosphorus contained in stock wastewater was carried out by using the combination of calcium hydroxide and magnesium sulfate. The flocculation was investigated as a function of coagulant dose, pH, mixing time, settling time and coagulant addition modes such as the sequential addition of the two coagulants and the simultaneous addition of them. The flocculation by the combination of calcium hydroxide and magnesium sulfate was compared with that by aluminum sulfate. The mechanism of flocculation was investigated as well. About 60% of COD in stock watewater was removed by flocculation with combination of calcium hydroxide and magnesium sulfate.

Nitrogen Removal in the Multi-stage Bed Attached Growth Process of $A^2/O$ System with Interanal Recycle Ratio (다단층 부착성장 공법($A^2/O$향)에서 순환비에 따른 질소제거)

  • 최규철;윤용수;정일현
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.95-102
    • /
    • 1997
  • The process which can stabilize water quality of treatment and improve nitrogen removal rate under the condition of high organic loading was developed by charging fibrous HBC media to single sludge nitrification-denitrification process. This process was operated easier, minimized the treatment cost, and shortened the retention time. To improve T-N removal rate, a part of nitrifing liquid at aerobic zone was recycled to anoxic zone by approximate internal recycle ratio. The experimental results are as follows ; T-N removal efficiency in the organic volumetric loading 0.14-0.19 kg/COD/m$^{3}$·d was obtained asmaxium of 85% at internal recycle ratio 2.5 and in more ratio than this it was decreased. Organic removal efficiency was about 91% under the overall experimental conditions and not influenced by recycle ratio.

  • PDF

Removal Characteristics of Iron, Manganese and Organics in Ground Water Using Ozonation (오존을 이용한 지하수의 철.망간 및 유기물 제거특성)

  • 선창욱;우달식;남상호
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.2
    • /
    • pp.43-49
    • /
    • 1997
  • Iron and manganese problems in ground water affect far more water systems than almost any other water quality concern. The purpose of this study is to find the optimum condition of ozonation for the removal of dissolved iron, manganese and other organics in the polluted ground water. We proposed 4mg/l, 8mg/l as optimum ozone dose for the removal of $Fe^{2+},{\;}Mn^{2+}$, respectively. The removal efficiencies of $COD_{Mn}$ and $COD_{Cr}$ in ozone dose of 2mg/l - 6mg/l were about 40-50%. The removal efficiency of $NH_{3}-N$ was about 30-40% at pH8.5. In conclusion, it needs further systematic study and research concerned to treatability of $Fe^{2+},{\;}Mn^{2+}$ and biodegradability of organic compounds using Ozonation followed by biological filtration process in ground water treatment train.

  • PDF

The Effect on HRT and Hydraulic Characteristics of Biological Activated Carbon Fluidized Bed. (생물활성탄 유동상의 수리학적 특성과 체류시간의 영향)

  • 우달식;김선일;남상호
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.103-109
    • /
    • 1997
  • As the quality of raw water deteriorates, a number of additional treatment techniques have been developed and adapted to water treatment for producing a safe and aesthetically satisfactory drinking water. So, BACFB process as pretreatment in water supply is to be effective to remove dissolved organics. This study performed to find out the effects of HRT and hydraulic characteristics on BACFB reactors in water supply. The flow type in reactor was a high dispersion with complete mixing. As superficial velocity was increased, bed expansion was closed to theoretical values. It was considered that below 30 min HRT could operated to ensure the removal of dissolved organics.

  • PDF

Investigation of Microbial Safety and Correlations Between the Level of Sanitary Indicator Bacteria and the Detection Ratio of Pathogens in Agricultural Water (농업용수의 미생물학적 안전성 조사 및 위생지표세균 농도와 병원성미생물 검출률과의 상관관계 분석)

  • Hwang, Injun;Lee, Tae Kwon;Park, Daesoo;Kim, Eunsun;Choi, Song-Yi;Hyun, Jeong-Eun;Rajalingam, Nagendran;Kim, Se-Ri;Cho, Min
    • Korean Journal of Environmental Agriculture
    • /
    • v.40 no.4
    • /
    • pp.248-259
    • /
    • 2021
  • BACKGROUND: Contaminated water was a major source of food-borne pathogens in various recent fresh produce-related outbreaks. This study was conducted to investigate the microbial contamination level and correlations between the level of sanitary indicator bacteria and the detection ratio of pathogens in agricultural water by logistic regression analysis. METHODS AND RESULTS: Agricultural water was collected from 457 sites including surface water (n=300 sites) and groundwater (n=157 sites) in South Korea from 2018 to 2020. Sanitary indicator bacteria (total coliform, fecal coliform, and Escherichia coli) and food-borne pathogens (pathogenic E. coli, E. coli O157:H7, Salmonella spp., and Listeria monocytogenes) were analyzed. In surface water, the coliform, fecal coliform, and E. coli were 3.27±0.89 log CFU/100 mL, 1.90±1.19 log CFU/100 mL, and 1.39±1.26 log CFU/100 mL, respectively. For groundwater, three kinds of sanitary indicators ranged in the level from 0.09 - 0.57 log CFU/100 mL. Pathogenic E. coli, Salmonella and Listeria monocytogenes were detected from 3%-site, 1.5%- site, and 0.6%-site water samples, respectively. According to the results of correlations between the level of sanitary indicator bacteria and the detection ratio of pathogens by logistic regression analysis, the probability of pathogen detection increased individually by 1.45 and 1.34 times as each total coliform and E. coli concentration increased by 1 log CFU/100mL. The accuracy of the model was 70.4%, and sensitivity and specificity were 81.5% and 51.7%, respectively. CONCLUSION(S): The results indicate the need to manage the microbial risk of agricultural water to enhance the safety of fresh produce. In addition, logistic regression analysis is useful to analyze the correlation between the level of sanitary indicator bacteria and the detection ratio of pathogens in agricultural water.

Scientific Consideration in Determining Shelf Life of Market Milk (시유의 유통기간 결정에 관한 학문적 고찰)

  • Choi, Suk-Ho
    • Journal of Dairy Science and Biotechnology
    • /
    • v.22 no.1
    • /
    • pp.27-35
    • /
    • 2004
  • The shelf lift of market milk should be determined based on the flavor which is influenced by environmental and sanitary conditions of dairy farm, milk processing plant, and storage and transportation facility as well as compositional quality, such as protein and fat, of the milk itself. The legal shelf life of market milk is often limited by microbiological quality, e.g. total bacterial count, coliform count, and food poisoning bacteria. The bacteria involved with milk spoilage and poisoning are originated from bacteria contaminating milk after pasteurization or spores surviving the heat treatment of pasteurization. The important factors which influence the shelf life of market milk are microbiological quality of raw milk, pasteurization condition, post-pasteurization contamination, and temperature during storage and transportation. The organoleptic quality and shelf life of market milk should be further improved by satisfying the consumer's taste, which depends on somatic cell count and bacterial count of milk, feed quality, foreign substance in milk, and physical treatment during processing and transportation.

  • PDF

A Study on Soil Pollution Quality of Chungbuk Province by Soil Network (토양측정망에 의한 충북지역 토양오염도)

  • 김재용;박선희
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.4
    • /
    • pp.77-89
    • /
    • 2001
  • The research is intended to evaluate the soil pollution quality of Chungbuk province with Soil Network which is executed every year. The survey executed with Soil Network in 1999 represented that the soil quality of Chungbuk province was relatively good as the average concentrations of contaminants in soil were Cd: 0.146 mg/17g, Cu: 3.143 mgHg, As: 0.636 mg/kg, Hg: 0.012 mg/kg, Pb): 4.505 mg/kg, $Cr^{+6}$ not detected, and the average pH was 6.1. The reckoned soil Pollution score (SPS) of Chungbuk province has been shown much low SPS distribution in the range from 1.6 to 141.7, average 31.0. However, it has been represented relatively high SPS distribution at Chungju, Tanyang, and Chinchon, respectively, It also huts represented high SPS distribution not only at agricultural area and waste area for the Pollution sources but at a paddy field and dry field for land use. The classification of soil pollution class(SPC) based on soil pollution score(SPS) was SPC 1 under 100 of SPS at 212 areas which were 98.6% of total 215 areas and SPC 2 over 100 of SPS at only three area left. There was no area exceeding soil pollution value among the whole Soil Network areas investigated, and the whole average for each items was much lower level th퍼n soil Pollution value was. When the average concentration of heavy metals and the average pH in soil of Chungbuk province are compared with the natural contents of that in Korea, the research is concluded that the average concentration of heavy met is relatively similar to the natural contents of that and the average pH in soil of Chungbuk province is a little higher than the natural contents of that. From this method, soil quality of most of the Soil Network area was estimated to be healthy.

  • PDF

Study on the Water Management to get High Quality of Drinking Water (이상적인 음료수 공급을 위한 수질관리에 관한 연구)

  • 김형석;신현덕;박경석
    • Journal of environmental and Sanitary engineering
    • /
    • v.6 no.1
    • /
    • pp.7-25
    • /
    • 1991
  • Until now, pure drinking water grnerally menas the water without taste, odor, general bacteria, coliform, and other exotic substance. Such a definition has been changing recently due to the finding of numerous other inorganic and organic substances unknown to us. 10 years ago, major causes of death were infectious agents and parasites contained in water, but recently, it has become apparent that some substances contained in drinking water cause cancer and heart diseases. We must drink about 2L of water everyday in order to maintain healthy condition. Waters used for drinking include tap water, well water, spring water, filtered water, etc., but the quality of drinking water has more polluted due to the industrial development and population increase. For example, industrial waste waters from industrial plants pollute the water supply sources ; toxic substances contained in the waste waters pollute the ground water sources by penetrating the geological strata, and municipal, livestock, public building waste waters also pollute the water supply sources. Sometimes, the polluted surface waters were announced to be polluted by various kinds of orgainc substance, and it is reported that the pollution of ground water by orga nic substances has few in number but high in its concectration comparing with those of surface water. As the water quality pollution level increases, so the amount of disinfectant also increase. For example, chlorine solution, one of widely used disinfectants, creates trihalomethane(THM), a carcinogen, and halogen compounds. According to Oliver, through chlorine disinfection process, humine substance and chlorine create bolatile organic halide and nonvolatile organic halide by chemical reaction. There are tens or hundreds filtering devices, but filtering principles and maintenance metjhods are different, so their efficiency tests are needed. According to Smith, the effeciency tests aginst over 30 Ameican filtering devices show that 10 devices can remove 85% of volatile organics and further studies on filtered waters are underway. In consideration of important impacts of polluted drinking water on national health, authors studied the state of water quality pollution against tap water used as drinking water, filtration device passed water, ground water, and conserved drinking water ; tested the efficiency of filtration devices for tap water ; tried to sep up the detection method by using ion chromatography based on negative ion and positive ion by using single column, and attemped the simple filtration method for general households.

  • PDF

A Study on the Mineral Water Quality in Asia Partial Area (아시아 일부지역의 광천수 수질특성에 관한 연구)

  • Hwang, Sang-Yong
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.3 s.61
    • /
    • pp.9-14
    • /
    • 2006
  • From March 1, 2005 to August 31, 2006 mineral water wells were selected for 13 areas in Southeast Asia (Indonesia, Philippines, Thailand, Singapore) and 20 areas in Northeast Asia (Korea, North Korea, China, Japan) and the study on their mineral water quality was analyzed. - Mineral water quality was the best in Korea. Mineral spring waters in some area of China and North Korea and in the whole area of the Southeast Asia were of poor quality. - The hardness of mineral water was the low in Korea $(10{\sim}47mg/L\;as\;CaCO_3)$, Japan $(4{\sim}66mg/L\;as\; CaCO_3)$, Geumgang-san North Korea Area $(4mg/L\;as\;CaCO_3)$. Mineral spring water in Thailand, Indonesia $(1{\sim}97.5mg/L\;as\;CaCO_3)$ and in the other area $(120{\sim}1205mg/L\;as\;CaCO_3)$ were high degree of hardness. - pH value in the mineral water of Southeast Asia $(pH\;6.7{\sim}8.2)$ and Northeast Asia $(pH\;5.9{\sim}7.9)$ was up to WHO standard $(pH\;6.5{\sim}8.5)$. Fluorine of negative ion was found in 10 mineral waters: Indonesian mineral water 'ATARTN'(0.02mg/L), Thailand mineral water 'SIAM' (0.6mg/L), 'MASAFI' (0.02mg/L). Korean mineral water 'SAEMMULNARA' (1.1mg/L), 'SANSU'(0.6mg/L), 'ICIS'(0.3mg/L), 'DONGWON SAEM-MUL'(0.03mg/L), 'PYEONGCHANG' (0.6mg/L), North Korean mineral water 'KUMGANGSAN'(0.1mg/L), Japanese mineral water 'CRYSTAL GEYSER'(0.55mg/L). However Fluorine in the other 23 mineral waters were not detectable.

Evaluation of the Bacteriological Safety of the Shellfish-growing Area in Gangjinman, Korea (강진만 패류생산해역의 위생학적 안전성 평가연구)

  • Park, Kun-Ba-Wui;Jo, Mi-Ra;Kwon, Ji-Young;Son, Kwang-Tea;Lee, Doo-Seog;Lee, Hee-Jung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.43 no.6
    • /
    • pp.614-622
    • /
    • 2010
  • The sanitary quality of a shellfish-growing area in Gangjinman, Korea, was assessed through a bacteriological examination of seawater form January 2007 to December 2009. The range of the geometric mean (GM) and the estimated 90th percentile for most-probable-number (MPN) values for fecal coliforms in samples collected in the designated area were 2.0-2.4 and 6.1-11.5 MPN/100 mL, respectively. Therefore, the bacteriological quality of seawater in the designated area in the Gangjinman area met the National Shellfish Sanitation Program (NSSP, USA) guidelines for approved areas. Also, the sanitary status of shellfish harvested from the designated area met the Korean Shellfish Sanitation Program (KSSP) fecal coliform criterion (<230 MPN/100 g). However, the degree of bacteriological contamination increased rapidly, and water quality exceeded the criteria for approved areas when large amounts of rain fell before the sampling date. Fortunately, fecal pollutants did not affect the bacteriological quality of a buffer zone established between the shoreline and the designated area. These results indicate that the current buffer zone established around the designated area protects the designated area properly.